• 제목/요약/키워드: CVCF inverter

검색결과 23건 처리시간 0.03초

인버어터 여자에 의한 유도발전기의 연구 (A Study on the Inverter-Excited Induction Generator)

  • 박민호;김진오;김경수;정승기
    • 대한전기학회논문지
    • /
    • 제34권8호
    • /
    • pp.331-337
    • /
    • 1985
  • An inverter-excited induction generator is discussed in this paper. A brief review of the capacitor-excited induction generator is given and the steady state characteristics of the induction generator excited by an inverter are evaluated. It is shown that the output voltage of the system can be controlled by adjusting the slip, for given operating conditions. The introduction of feedback control makes it possible to control the output voltage stably over the wide range of speed and load. Experimental results are given. The output of the induction generator is then converted into a CVCF(Constant Voltage-Constant Frequency) power source using a PWM inverter with simple control circuit.

  • PDF

디젤발전기가 포함된 독립형 마이크로그리드에서의 BESS 제어기법 및 운전모드 연구 (Control and Operating Modes of Battery Energy Storage System for a Stand-Alone Microgrid with Diesel Generator)

  • 조종민;안현성;김지찬;차한주
    • 전력전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.86-93
    • /
    • 2018
  • In this work, control methods and operating modes are proposed to manage standalone microgrid. A standalone microgrid generally consists of two sources, namely, battery energy storage system (BESS) and diesel generator (DG). BESS is the main source that supplies active and reactive power regardless of load conditions, whereas DG functions as an auxiliary power source. BESS operates in a constant voltage constant frequency (CVCF) control, which includes proportional-integral + resonant controller in a parallel structure. In CVCF control, the concept of fundamental positive and negative transformation is utilized to generate a three-phase sinusoidal voltage under imbalanced load condition. Operation modes of a standalone microgrid are divided into three modes, namely, normal, charge, and manual modes. To verify the standalone microgrid along with the proposed control methods, a demonstration site is constructed, which contains 115 kWh lead-acid battery bank, 50 kVA three-phase DC - AC inverter, and 50 kVA DG and controllable loads. In the CVCF control, the total harmonic distortion of output voltage is improved to 1.1% under imbalanced load. This work verifies that the standalone microgrid provides high-quality voltage, and three operation modes are performed from the experimental results.

불평형 및 비선형부하 시 전력품질 향상을 위한 독립형 인버터의 전압제어 기법 (Voltage Control of Stand-Alone Inverter for Power Quality Improvement Under Unbalanced and Non-linear Load)

  • 이우종;조종민;차한주
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.567-575
    • /
    • 2016
  • This paper proposed the voltage control of stand-alone inverter for power quality improvement under unbalanced and non-linear load. The 3-phase DC-AC inverter controls CVCF(Constant Voltage Constant Frequency) and selective harmonic eliminate method in stand-alone mode by PR controller, and the stand-lone inverter supplies stable sinusoidal voltage to balanced, unbalanced and non-linear loads. The total harmonic distortion(THD) of line-to-line load voltage($V_{LL}$) is 1.2% in the balanced load. THD of $V_{LL}$ is reduced from 5.2% to 1.4% and 6.7% to 3.5%, respectively unbalanced and non-linear load. The stand-alone inverter can be supplies sinusoidal balanced voltage to unbalanced load because the voltage unbalanced factor(VUF) of $V_{LL}$ is reduced from 5.2% to 1.4% in the unbalanced load. Feasibility of control method for a stand-alone inverter will be verified through 30kW stand-alone inverter system.

순시 전류 phaser 제어방식의 전압형 고주파 공진 인버터 (Voltage-fed high frequency resonent inverter of instantaneous current phaser control method)

  • 이경호;노채균;김동희;이봉섭;박종국;정도영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.348-351
    • /
    • 2001
  • In this paper, voltage-fed high frequency resonant inverter of instantaneous current phaser control method used to DC voltage source separated is proposed. In the output control method, a novel circuit type of phase shift driving signal method with CVCF illustrated, also the operation principle of the proposed circuit is described in detail and its characteristics are presented as to normalized parameters. According to the each mode, in order to the circuit analysis and characteristic evaluation of the state equation are derives and present used to normalized parameter. In the future, this proposed inverter show that it can be practically used as power source system for the lighting equipment of discharge lamp, DC-DC converter etc.

  • PDF

Ni-Cd전지용 충전 알고리즘을 이용한 고속전철용 ZVZCS형 충전장치개발 (The Development of ZVZCS type Battery Charger for High Speed Trail Car with Ni-Cd Battery Charging Algorithm)

  • 김연준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.548-551
    • /
    • 2000
  • The battery charger for high speed trail car is very important power source for the purpose of safty and system stability. it provides control power of VVVF, CVCF, DC/DC converter and inverter for traction motor. This paper included power circuit of the ZVZCS type battery charger for high speed trail car and battery included power circuit of the ZVZCS type battery charger for high speed trail car and inverter for traction motor. This paper included power circuit of the ZVZCS type battery charger for high speed trail car an battery charging algorithm. Also the optimum parallel operation of 50Kw battery charger for high speed trail car and charging control method of Ni-Cd battery illustrates validity and effectiveness through the experiments.

  • PDF

PLL보상루프를 이용할 단상 PWM 인버터의 정밀 전압제어 (A Precision Voltage Control of Single Phase PWM Inverters Using PLL Compensation Loop)

  • 정세교;최성락;최진우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.185-189
    • /
    • 2001
  • This paper presents a precision voltage control technique of a single phase PWM inverter for a constant voltage and constant frequency(CVCF) applications. The proposed control employes a PLL compensating loop which minimize the steady state error and phase delay. The computer simulation and experiment are carried out for the actual single phase PWM inverter and the results well demonstrate the effectiveness of the proposed control.

  • PDF

커패시터 분할형을 갖는 직렬공진 고주파 인버터의 특성해석 (Characteristic Analysis of Series Resonant High Frequency Inverter with Separated Capacitor)

  • 이봉섭;오승훈;정도영;이상호;고서영;오홍석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1224-1226
    • /
    • 2000
  • In this paper, load paralleled type FB series resonant inverter of a new novel type is proposed. In the output control method, phase-shift driving signal control method with CVCF introduces. Also by driving signal patterns, the operation principle of the proposed circuit in detail is described and its characteristics are compared on separated ratio(n). According to each the mode in order to the analysis and characteristic evaluation of the circuit state equations are derived and presented using normalized parameter. To verify the theoretical analysis result, experimental results are provided.

  • PDF

Novel Soft Starting Algorithm of Single Phase Induction Motors by Using PWM Inverter

  • Kim, Hae-Jin;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1720-1728
    • /
    • 2018
  • This paper proposes a novel soft starting algorithm by using PWM inverter technique to control an amplitude of the motor starting current at a single-phase induction motor (SPIM). Traditional SPIM starting methods such as a Split-Phase, Capacitor-Start, Permanent-Split Capacitor (PSC), Capacitor-Start Capacitor-Run (CSCR), basically cannot control the magnitude of starting current due to the fixed system structures. Therefore, in this paper, a soft starting algorithm based on a proportional resonant (PR) control with a variable and constant frequency is proposed to reduce the inrush current and starting up time. In addition, a transition algorithm for operation modes is devised to generate a constant voltage and constant frequency (CVCF). The validity and effectiveness of the proposed soft starting method and transition algorithm are verified through experimental results.

독립형 풍력발전용 PWM 인버터의 출력전압의 비선형 제어 (Nonlinear Control of Output Voltages of PWM Inverters for Stand-Alone Wind Power Generation)

  • 장정익;구성영;이동춘
    • 전력전자학회논문지
    • /
    • 제12권2호
    • /
    • pp.131-138
    • /
    • 2007
  • 본 논문은 출력단에 LC필터를 갖는 3상 PWM 인버터의 출력전압을 일정전압/일정주파수로 제어하기 위한 새로운 비선형 제어기법을 제안한다. 출력 LC필터를 포함한 비선형 모델을 궤환선형화(feedback linearization) 이론을 통하여 선형화하고 선형 제어이론에 기초하여 제어기를 설계한다. 이 제어기는 LC 출력필터를 갖는 PWM 인버터를 사용하는 독립형 풍력발전 시스템에 적용된다. 제안한 제어기법은 정상상태와 부하변동의 과도상태에 대한 실험을 통하여 검증된다.

시평균화방법을 이용한 PWM 신호발생에 관한 연구 (A Study on the PWM Generation using Time Average Model)

  • 홍순욱;차재덕;조규복
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1088-1091
    • /
    • 1992
  • Programmed PWM(Pulse Width Modulated) generation techniques eliminating several low order harmonics have been widely used in the inverter circuit which produces minimum current ripple, reduced torque pulsation and thereby improves overall system performance. However, the applications of the programmed PWM technique are limited to CVCF(Constant Voltage Constant Frequency) applications and various motor drives. Although the programmed PWM produces a lower harmonic distorted waveform than the carrier modulated PWM, real-time programming is not possible because of the complicated calculation required for the gating signal. In this paper, a new programmed PWM technique named TAM (time averaging model) is developed to compensate for the demerits of the conventional programmed PWM technique with moderate harmonic distortion. Computer simulations are performed to verify the performance of the proposed algorithm.

  • PDF