• 제목/요약/키워드: CVCF control

검색결과 25건 처리시간 0.022초

권선형 유도발전기의 CVCF 발전을 위한 2차 여자제어법에 관한 연구(III) (A Study on the CVCF Contorl of Wound Rotor Induction Gernerator by 2nd Exitation(III))

  • 안진우;이일천;황영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.55-59
    • /
    • 1991
  • This paper deals with the control stratege for the constant voltage, constant frequency(CVCF) generation of doubly-fed induction generator. As an induction machine is a nonlinear and multivariable machine, so, the control system is needed a very sophiticated control processes to meet a CVCF condition. In this paper, control system is constructed and tested using the suggested exitation equation. The test results show that the suggested equation and control system are very useful strategy for the CVCF control of induction generator.

  • PDF

권선형 유도발전기 CVCF를 위한 2차 여자제어법에 관한 연구 (II) (A Study on the 2nd Excitation Method for CVCF Generation of Doubly-fed Induction Generator (II))

  • 안진우;황영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.45-48
    • /
    • 1990
  • This paper deals with the control strategy for constant voltage, constant frequency (CVCF) generation of doubly-fed Induction generator. As induction machine is a nonlinear and multivariable machine, so, the influential factors for CVCF generation of induction generator are the magnitude of output voltage, load current and its power factor, slip of the machine, etc. To get appropriate control scheme and to research the effect of its parameters, the control equation of induction machine is derived and tested. The derived condition is very useful for the CVCF control of the machine and for determing the characteristics of the system. The simulation results show that magnetizing reactance and rotor resistance is a very important parameter in this control system.

  • PDF

권선형 유도발전기의 CVCF 발전을 위한 2자여자제어법에 관한 연구 (A Study on the 2nd Exitation for CVCF Generation of Doubly-fed Induction Generator)

  • 안진우;황영문
    • 대한전기학회논문지
    • /
    • 제40권7호
    • /
    • pp.656-663
    • /
    • 1991
  • This paper deals with the control strategy for the constant voltage, constant frequency (CVCF) generation of doubly -fed induction generator. Since induction machine is a nonlinear and multivariable one, the influential factors for CVCF generation of induction generator are the magnitude of output voltage, load current and its power factor, slip of the machine, etc. To get appropriate control scheme and study the effect of its parameters, the control equation of induction machine is derived and tested. The simulation and test results show that suggested equation and control system are very useful strategy for the CVCF control of induction generator.

  • PDF

BESS-디젤발전기 연계 CVCF 제어 안정도 향상기법 설계 및 해석 (Design and Analysis of CVCF Control for Stability Improvement of BESS and Diesel Generator Operation)

  • 박종화;조종민;권성철;차한주
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.194-195
    • /
    • 2017
  • 본 논문은 독립형 마이크로그리드에서 BESS-디젤발전기 연계운전 시, 동기 인덕턴스와 LCL 필터의 상호간섭을 고려한 CVCF 제어기를 설계하고 해석하였다. CVCF 제어의 외부루프는 비례-공진(PR)을 이용한 기본파 전압제어이고, 내부루프는 제어 안정도 향상을 위한 커패시터 전류제어로 구성된 이중 루프 구조이다. 인버터 $1.5T_s$ 시지연을 고려하여 모델링을 설계하고, 이산시간 영역에서의 근궤적 기법을 통해 CVCF 제어의 안정도를 해석하였다. 50kW BESS-디젤발전기로 구성된 시뮬레이션을 통해 안정도 해석과 동일한 결과를 도출함으로써 설계된 CVCF 제어기를 검증하였다.

  • PDF

CVCF용 VSI의 출력필터 설계 (Output Filter Design of Voltage Source Inverter for CVCF System)

  • 김재식;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.287-290
    • /
    • 1999
  • This paper describes an optimal design method of VSI output filter for CVCF system. The cost function is used for design, and all parameters are described in p.u(per unit) so that can be adapted to the change of CVCF rating. The capacitor current feedback scheme is proposed to control the damping ratio of the filter plant to meet the system more stable. This means that the LC resonance can be suppressed well in transient condition and can use the same control gains under the change of system capacity. The validity of the proposed method is well verified with the theoretical analysis and simulation results.

  • PDF

디젤발전기가 포함된 독립형 마이크로그리드에서의 BESS 제어기법 및 운전모드 연구 (Control and Operating Modes of Battery Energy Storage System for a Stand-Alone Microgrid with Diesel Generator)

  • 조종민;안현성;김지찬;차한주
    • 전력전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.86-93
    • /
    • 2018
  • In this work, control methods and operating modes are proposed to manage standalone microgrid. A standalone microgrid generally consists of two sources, namely, battery energy storage system (BESS) and diesel generator (DG). BESS is the main source that supplies active and reactive power regardless of load conditions, whereas DG functions as an auxiliary power source. BESS operates in a constant voltage constant frequency (CVCF) control, which includes proportional-integral + resonant controller in a parallel structure. In CVCF control, the concept of fundamental positive and negative transformation is utilized to generate a three-phase sinusoidal voltage under imbalanced load condition. Operation modes of a standalone microgrid are divided into three modes, namely, normal, charge, and manual modes. To verify the standalone microgrid along with the proposed control methods, a demonstration site is constructed, which contains 115 kWh lead-acid battery bank, 50 kVA three-phase DC - AC inverter, and 50 kVA DG and controllable loads. In the CVCF control, the total harmonic distortion of output voltage is improved to 1.1% under imbalanced load. This work verifies that the standalone microgrid provides high-quality voltage, and three operation modes are performed from the experimental results.

독립형 풍력발전 시스템의 CVCF 제어 (CVCF Control of Stand-Alone Wind Power System)

  • 김형균;;이동춘;석줄기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.379-382
    • /
    • 2003
  • In this paper, a novel nonlinear control method of the CVCF(constant voltage and constant frequency output voltage for the three-phase PWM inverter is proposed, which gives high dynamic responses at load variation as well as zero steady-state error. The experimental results are shown th verify the validity of the proposed scheme.

  • PDF

밧데리 방전 및 제어 전원 수전불가시 자생기동 가능한 전동차용 보조전원장치 (AuxiliaryPower Device of Spontaneous starting for Railway Vehicle when electric overdischarge or an impossibility of being supplied with control power)

  • 정순영;김상균;이현석;이경복
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.548-553
    • /
    • 2003
  • Battery supplies Each Electric device in Railway vehicles with Control Power. When Battery is overchargedjustly, the battery voltage is not satisfied with the minimum operating voltage, CVCF Inverter(SIV) is supplied with external Power supply or the other railway vehicles and start up CVCF Inverter. In this paper to improve this problem, Dead battery Starter system is proposed. When the battery voltage is not satisfied with the minimum value.turn on the Dead Battery Starter switch, and the Dead Battery Starter supplies the control power to the SIV controller from the line voltage. With this Dead Battery Starter system, the train can be operated when the battery is not proper status. Dead Battery Starter is designed by ROTEM and will be delivered to Attiko Metro Series 2.

  • PDF

Ni-Cd전지용 충전 알고리즘을 이용한 고속전철용 ZVZCS형 충전장치개발 (The Development of ZVZCS type Battery Charger for High Speed Trail Car with Ni-Cd Battery Charging Algorithm)

  • 최욱돈;이종필;이재문;김연준
    • 전력전자학회논문지
    • /
    • 제5권5호
    • /
    • pp.493-500
    • /
    • 2000
  • 고속전철용 충전기는 VVVF, CVCF, DC/DC 컨버터에 전원을 공급하고 안정성과 시스템의 신뢰성을 목적으로 하는 중요한 에너지원이다. 본 논문에서는 밧데리 충전 알고리즘과 고속전철용 ZVZCS형 밧데리 충전기의 전력회로를 포함한다. 또한 고속전철용 50kW 충전기의 최적 병렬운전과 Ni-Cd 밧데리의 충전 방법을 설명하고 실험을 통해 타당성을 입증한다.

  • PDF

철도차량용 보조전원장치의 전향제어를 이용한 Flicker 제어 (The Flicker Control by Feed-forward for Stabilization of CVCF Inverter)

  • 박채운;신형진;조국춘;원충연
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.267-272
    • /
    • 1999
  • The auxiliary power supply system fur passenger service of railway car has been developed from MA(Motor-Alternator) to CVCF Inverter (Static Inverter). Generally, a customer wants to apply tile new control method and device for auxiliary power supply of railcar However, if the auxiliary power supply is supplied to extended existing line, the maintenance cost of the old system is less expensive than new developed system, so, the customer specifies that the auxiliary power supply has compatibility with existing one completely. At that time, the hardware is nearly same as existing system except small changes of accessories for better performance. This paper describes the flicker control using feed-forward method of auxiliary power supply system for new 50 electric railcars, which are delivered to Korean National Railroad (KNR) Kwa-chon Line. The existing power supply system has damping resistor box to stabilize the DC input (1.5 ㎸). At this time, for better system efficiency the new system has not include resistor box but new control method including feed-forward control is applied. This control algorithm realizes the better stabilization of input power compared to the result of the existing system, which includes resistor box

  • PDF