• Title/Summary/Keyword: CVCF (constant voltage constant frequency)

Search Result 22, Processing Time 0.024 seconds

The secondary excited induction generator in random wave input system

  • Kim, Moon-Hwan
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.2
    • /
    • pp.209-214
    • /
    • 2009
  • The employment of the induction generator is preferable in the natural energy utilization by the minimum maintenance and the mechanical robustness, Another merit is also expected when it is connected to the power network system, because constant-voltage and constant frequency (CVCF) power generation is easily realized in spite of the variation of the rotor speed. However the induction generator needs much amount of the reactive power that reduces power factor in the primary side. The improvement of power factor in the primary side requires large VAR compensator, this point is solved, the merit of the induction machine as a main generator will become more established. This paper proposes a novel approach where the secondary is controlled by a PWM inverter not only to get CVCF power but also to improve the primary power factor. Basically the inverter is controlled so that the field current is supplied from the secondary side in this approach. The required capacity of the inverter is small, because only the slip power is controlled in the secondary side. In the experimental system where the sea wave torque simulator is used, the power factor is well improved by the microcomputer controlled PWM inverter.

Novel Soft Starting Algorithm of Single Phase Induction Motors by Using PWM Inverter

  • Kim, Hae-Jin;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1720-1728
    • /
    • 2018
  • This paper proposes a novel soft starting algorithm by using PWM inverter technique to control an amplitude of the motor starting current at a single-phase induction motor (SPIM). Traditional SPIM starting methods such as a Split-Phase, Capacitor-Start, Permanent-Split Capacitor (PSC), Capacitor-Start Capacitor-Run (CSCR), basically cannot control the magnitude of starting current due to the fixed system structures. Therefore, in this paper, a soft starting algorithm based on a proportional resonant (PR) control with a variable and constant frequency is proposed to reduce the inrush current and starting up time. In addition, a transition algorithm for operation modes is devised to generate a constant voltage and constant frequency (CVCF). The validity and effectiveness of the proposed soft starting method and transition algorithm are verified through experimental results.

A Precision Voltage Control of Single Phase PWM Inverters Using PLL Compensation Loop (PLL보상루프를 이용할 단상 PWM 인버터의 정밀 전압제어)

  • Chung Se-Kyo;Choi Seong-Rak;Choi Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.185-189
    • /
    • 2001
  • This paper presents a precision voltage control technique of a single phase PWM inverter for a constant voltage and constant frequency(CVCF) applications. The proposed control employes a PLL compensating loop which minimize the steady state error and phase delay. The computer simulation and experiment are carried out for the actual single phase PWM inverter and the results well demonstrate the effectiveness of the proposed control.

  • PDF

A Study on the Inverter-Excited Induction Generator (인버어터 여자에 의한 유도발전기의 연구)

  • 박민호;김진오;김경수;정승기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.8
    • /
    • pp.331-337
    • /
    • 1985
  • An inverter-excited induction generator is discussed in this paper. A brief review of the capacitor-excited induction generator is given and the steady state characteristics of the induction generator excited by an inverter are evaluated. It is shown that the output voltage of the system can be controlled by adjusting the slip, for given operating conditions. The introduction of feedback control makes it possible to control the output voltage stably over the wide range of speed and load. Experimental results are given. The output of the induction generator is then converted into a CVCF(Constant Voltage-Constant Frequency) power source using a PWM inverter with simple control circuit.

  • PDF

A Stable Operation Strategy in Micro-grid Systems without Diesel Generators

  • Choi, Sung-Sik;Kang, Min-Kwan;Lee, Hu-Dong;Nam, Yang-Hyun;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.114-123
    • /
    • 2018
  • Recently, as one of the countermeasures to reduce carbon dioxide($CO_2$) for global warming problems, operation methods in micro-grid systems replacing diesel generator with renewable energy sources including wind power(WP) and photovoltaic(PV) system have been studied and presented in energetic manners. However, it is reported that some operation problems in micro-grid systems without diesel generator for carbon-free island are being occurred when large scaled WP systems are at start-up. To overcome these problems, this paper proposes an operation strategy in micro-grid systems by adapting control devices such as CVCF(constant voltage constant frequency) ESS(energy storage system) for constant frequency and voltage regulation, load control ESS for balancing demand and supply and SVC(static-var compensator) for reactive power compensation. From the simulation results based on the various operation scenarios, it is confirmed that the proposed operation strategy in micro-grid systems without diesel generators is a useful tool to perform a stable operation in micro-grid systems without diesel generator and also make a contribution to reduce carbon dioxide in micro-grid systems.

Voltage Control of Stand-Alone Inverter for Power Quality Improvement Under Unbalanced and Non-linear Load (불평형 및 비선형부하 시 전력품질 향상을 위한 독립형 인버터의 전압제어 기법)

  • Lee, Wujong;Jo, Jongmin;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.567-575
    • /
    • 2016
  • This paper proposed the voltage control of stand-alone inverter for power quality improvement under unbalanced and non-linear load. The 3-phase DC-AC inverter controls CVCF(Constant Voltage Constant Frequency) and selective harmonic eliminate method in stand-alone mode by PR controller, and the stand-lone inverter supplies stable sinusoidal voltage to balanced, unbalanced and non-linear loads. The total harmonic distortion(THD) of line-to-line load voltage($V_{LL}$) is 1.2% in the balanced load. THD of $V_{LL}$ is reduced from 5.2% to 1.4% and 6.7% to 3.5%, respectively unbalanced and non-linear load. The stand-alone inverter can be supplies sinusoidal balanced voltage to unbalanced load because the voltage unbalanced factor(VUF) of $V_{LL}$ is reduced from 5.2% to 1.4% in the unbalanced load. Feasibility of control method for a stand-alone inverter will be verified through 30kW stand-alone inverter system.

Development of the 7kW Power Conversion Unit for Generator Special Vehicle (발전 특장차를 위한 7kW급 전력변환장치 개발)

  • Han, Keun-Woo;Choi, Myoung-Hyun;Kim, Seong-Gon;Lee, Chung-Hoon;Han, Man-Seung;Seon, Han-Geol;Hong, Sung-Ryeul
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.419-420
    • /
    • 2016
  • 종전의 이동형 발전시스템은 부피와 소음이 크고, 응답속도와 발전이 효율 낮은 등의 단점이 있다. 때문에 CVCF(Constant Voltage Constant Frequency)의 안정적인 상용전원(220V,60Hz)을 공급 가능한 전력변환장치가 요구된다. 본 논문에서는 이러한 단점을 개선하고자 정전압 및 정주파수의 정현파 출력이 가능한 7kW급 전력 변환장치를 제안하였다.

  • PDF

A Study on the PWM Generation using Time Average Model (시평균화방법을 이용한 PWM 신호발생에 관한 연구)

  • Hong, Soon-Wook;Cha, Jae-Deok;Cho, Kyu-Bock
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1088-1091
    • /
    • 1992
  • Programmed PWM(Pulse Width Modulated) generation techniques eliminating several low order harmonics have been widely used in the inverter circuit which produces minimum current ripple, reduced torque pulsation and thereby improves overall system performance. However, the applications of the programmed PWM technique are limited to CVCF(Constant Voltage Constant Frequency) applications and various motor drives. Although the programmed PWM produces a lower harmonic distorted waveform than the carrier modulated PWM, real-time programming is not possible because of the complicated calculation required for the gating signal. In this paper, a new programmed PWM technique named TAM (time averaging model) is developed to compensate for the demerits of the conventional programmed PWM technique with moderate harmonic distortion. Computer simulations are performed to verify the performance of the proposed algorithm.

  • PDF

A Study of Smart Uninterruptible Power Supply Capable High Efficiency Drive (고효율 운전이 가능한 지능형 무정전 전원장치에 관한 연구)

  • Eom, Tae-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.61-66
    • /
    • 2013
  • In this paper, a control scheme with the capability of high efficiency, which is realized by predicting the conditions of a load power and an input power, is proposed for the uninterruptible power supply (UPS). Generally, on-line UPS system supplies a constant voltage and a constant frequency (CVCF). However, the efficiency of the On-line UPS system can be reduced due to the switching losses of semiconductor devices during the power conversion. The these losses are improved by the proposed smart UPS with the high efficiency drive system, which is realized by analysing and predicting the conditions of a load power and an input power.

Design of Multiloop Control of Stand-alone Inverter for Power Quality Improvement under Unbalanced Load (불평형부하 시 전력품질 향상을 위한 독립형 인버터의 다중루프 제어기 설계)

  • Jo, Jongmin;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.327-328
    • /
    • 2015
  • 본 논문은 불평형부하 조건에서 전력품질 향상을 위한 독립형 인버터의 다중루프 제어기를 설계하고 실험적으로 검증하였다. CVCF(Constant Voltage Constant Frequency) 제어를 수행하는 독립형 인버터에 정지좌표계 상에서 다중루프 특성을 갖는 전압-전류 제어기를 설계하여 불평형 부하에 안정적인 전력공급을 수행하도록 구현하였다. 전압 제어기는 기본파 및 선택적 고조파 제어특성을 갖는 PR(Proportional-Resonant, 비례-공진)제어기를, 전류제어기는 P제어기를 적용하였다. 50kW 독립형 인버터 프로토타입을 구현하였으며, 불평형부하 조건에서 기존 동기좌표계 PI 제어와 비교할 때, 선간전압 THD는 4.3%에서 0.9%, 불평형률은 4.3%에서 0.35%로 개선됨으로써 제안된 기법의 타당성을 검증하였다.

  • PDF