• Title/Summary/Keyword: CVCF (constant voltage constant frequency)

Search Result 22, Processing Time 0.045 seconds

A Study on the Transient Operation Algorithm in Micro-grid based on CVCF Inverter (CVCF 인버터 기반의 Micro-grid에 있어서 과도상태 운용알고리즘에 관한 연구)

  • Lee, Hu-Dong;Choi, Sung-Sik;Nam, Yang-Hyun;Son, Joon-Ho;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.526-535
    • /
    • 2018
  • Recently, in order to reduce the $CO_2$ emission in the island area, countermeasures to operate power system in a stable manner are being researched due to decrease of the operation rate in diesel generators and the increase of renewable energy sources. The phenomenon of energy sinking can be occurred if the output of renewable energy sources is larger than customer loads. Voltage of CVCF(constant voltage & constant frequency) battery could be increased rapidly according to the condition of SOC(state of charge) and blackout could be occurred due to shut-down of CVCF inverter, at carbon free island micro-grid based on the CVCF inverter. In order to overcome these problems, this paper proposes a transient operation algorithm in CVCF based micro-grid which in advance prevents shut-down of CVCF inverter during the energy sinking. And also this paper proposes the modeling of micro-grid including CVCF inverter, PV system, customer load using PSCAD/EMTDC S/W. From the results of micro-grid modeling based on the proposed algorithm, it is confirmed that CVCF based micro-grid can properly prevent shut-down of CVCF inverter according to SOC and battery voltage of CVCF inverter when energy sinking is occurred.

A Study on the 2nd Excitation Method for CVCF Generation of Doubly-fed Induction Generator (II) (권선형 유도발전기 CVCF를 위한 2차 여자제어법에 관한 연구 (II))

  • Ahn, Jin-Woo;Hwang, Young-Moon
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.45-48
    • /
    • 1990
  • This paper deals with the control strategy for constant voltage, constant frequency (CVCF) generation of doubly-fed Induction generator. As induction machine is a nonlinear and multivariable machine, so, the influential factors for CVCF generation of induction generator are the magnitude of output voltage, load current and its power factor, slip of the machine, etc. To get appropriate control scheme and to research the effect of its parameters, the control equation of induction machine is derived and tested. The derived condition is very useful for the CVCF control of the machine and for determing the characteristics of the system. The simulation results show that magnetizing reactance and rotor resistance is a very important parameter in this control system.

  • PDF

A Study on the 2nd Exitation for CVCF Generation of Doubly-fed Induction Generator (권선형 유도발전기의 CVCF 발전을 위한 2자여자제어법에 관한 연구)

  • 안진우;황영문
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.7
    • /
    • pp.656-663
    • /
    • 1991
  • This paper deals with the control strategy for the constant voltage, constant frequency (CVCF) generation of doubly -fed induction generator. Since induction machine is a nonlinear and multivariable one, the influential factors for CVCF generation of induction generator are the magnitude of output voltage, load current and its power factor, slip of the machine, etc. To get appropriate control scheme and study the effect of its parameters, the control equation of induction machine is derived and tested. The simulation and test results show that suggested equation and control system are very useful strategy for the CVCF control of induction generator.

  • PDF

A Study on the 2nd exitation method for CVCF Generation of doubly-fed induction Generator (권선형 유도 발전기 CVCF 발전을 위한 2차 여자 제어법에 관한 연구)

  • Ahn, Jin-Woo;Kim, Chul-Woo;Hwang, Young-Moon
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.341-344
    • /
    • 1988
  • This paper derives a condition foe constant voltage i constant frequency generation of doubly-fed induction generator. The condition is varied by the magnitude of output voltage, load current and its power factor, slip of the machine. Magnitude of output voltage is controlled by exiting voltage which is caculated by derived equation from operating condition. frequency of output voltage is controlled by injecting slip frequency to the rotor which is the difference between wanted output frequency and rotor frequency.

  • PDF

Normal Operation Characteristics of 30kW Scale CVCF Inverter-Based Micro-grid System (30kW급 CVCF 인버터 기반의 Micro-grid의 정상상태 운용특성에 관한 연구)

  • Ferreira, Marito;Lee, Hu-Dong;Tae, Dong-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.662-671
    • /
    • 2020
  • Recently, for the purposes of reducing carbon dioxide(CO2) emissions in the island area, countermeasures to decrease the operation rate of diesel generator(DG) and to increase one of renewable energy sources(RES) is being studied. In particular, the demonstration and installation of stand-alone micro-grid(MG) system which is composed of DG, RES and energy storage system(ESS) has been implemented in some island areas such as Gapa-do, Gasa-do and Ulleung-do island. However, many power quality(PQ) problems may be occurred due to an intermittent output of RES including photovoltaic(PV) system and wind power(WP) system in a normal operating of constant voltage & constant frequency(CVCF) inverter-based MG system. Therefore, this paper presents a modeling of the 30kW scale MG system using PSCAD/EMTDC, and also implements a 30kW scale CVCF inverter-based MG system as test devices to analyze normal operating characteristics of MG system. From the simulation and test results, it is confirmed that the proposed methods are useful and practical tools to improve PQ problems such as under-voltage, over-voltage and unbalanced load in CVCF inverter-based MG system.

Steady-State Performance Improvement of Single-Phase PWM Inverters Using PLL Technique (PLL 기법을 이용한 단상 PWM 인버터의 정상상태 성능개선)

  • 정세교;이대식
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.356-363
    • /
    • 2004
  • This paper presents a precision voltage control technique of a single phase PWM inverter for a constant voltage and constant frequency(CVCF) applications. The proposed control scheme employs an additional phase-locked loop(PLL) compensator which is constructed using the output capacitor voltage and current. The computer simulation and experiment are carried out for the actual single-phase PWM inverter and it is well demonstrated from these results that the steady-state performance and total harmonic distortion(THD) are remarkably improved by employing the proposed technique.

A Study on the CVCF Contorl of Wound Rotor Induction Gernerator by 2nd Exitation(III) (권선형 유도발전기의 CVCF 발전을 위한 2차 여자제어법에 관한 연구(III))

  • Ahn, Jin-Woo;Lee, Il-Chun;Hwang, Young-Moon
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.55-59
    • /
    • 1991
  • This paper deals with the control stratege for the constant voltage, constant frequency(CVCF) generation of doubly-fed induction generator. As an induction machine is a nonlinear and multivariable machine, so, the control system is needed a very sophiticated control processes to meet a CVCF condition. In this paper, control system is constructed and tested using the suggested exitation equation. The test results show that the suggested equation and control system are very useful strategy for the CVCF control of induction generator.

  • PDF

CVCF Control of Stand-Alone Wind Power System (독립형 풍력발전 시스템의 CVCF 제어)

  • Kim H.K.;Abo-Khalil Ahmed;Lee D.C.;Seok J.K.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.379-382
    • /
    • 2003
  • In this paper, a novel nonlinear control method of the CVCF(constant voltage and constant frequency output voltage for the three-phase PWM inverter is proposed, which gives high dynamic responses at load variation as well as zero steady-state error. The experimental results are shown th verify the validity of the proposed scheme.

  • PDF

A Study on the Modeling and Operation Algorithm of Independent Power System for Carbon Free (Carbon Free를 위한 도서지역용 독립전원계통의 모델링 및 운용알고리즘에 관한 연구)

  • Wang, Jong-Yong;Kim, Byung-Ki;Park, Jea-Bum;Kim, Byung-Mok;Kim, Eung-Sang;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.760-768
    • /
    • 2016
  • Recently, as one of the policies for carbon free operation method of independent power system replacing diesel generator with renewable energy such as wind power and photovoltaic(PV) system has been presented. Therefore, this paper proposes an operation algorithm and modeling of independent power system by considering CVCF(constant voltage constant frequency) ESS(energy storage system) for constant frequency and voltage, LC(load control) ESS for demand and supply balancing and SVC(static var compensator) for reactive power compensation. From the simulation results based on the various operation scenario, it is confirmed that proposed operation algorithm and modeling may contribute stable operation and carbon free in independent power system.

Control and Operating Modes of Battery Energy Storage System for a Stand-Alone Microgrid with Diesel Generator (디젤발전기가 포함된 독립형 마이크로그리드에서의 BESS 제어기법 및 운전모드 연구)

  • Jo, Jongmin;An, Hyunsung;Kim, Jichan;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.2
    • /
    • pp.86-93
    • /
    • 2018
  • In this work, control methods and operating modes are proposed to manage standalone microgrid. A standalone microgrid generally consists of two sources, namely, battery energy storage system (BESS) and diesel generator (DG). BESS is the main source that supplies active and reactive power regardless of load conditions, whereas DG functions as an auxiliary power source. BESS operates in a constant voltage constant frequency (CVCF) control, which includes proportional-integral + resonant controller in a parallel structure. In CVCF control, the concept of fundamental positive and negative transformation is utilized to generate a three-phase sinusoidal voltage under imbalanced load condition. Operation modes of a standalone microgrid are divided into three modes, namely, normal, charge, and manual modes. To verify the standalone microgrid along with the proposed control methods, a demonstration site is constructed, which contains 115 kWh lead-acid battery bank, 50 kVA three-phase DC - AC inverter, and 50 kVA DG and controllable loads. In the CVCF control, the total harmonic distortion of output voltage is improved to 1.1% under imbalanced load. This work verifies that the standalone microgrid provides high-quality voltage, and three operation modes are performed from the experimental results.