• 제목/요약/키워드: CV cable

검색결과 63건 처리시간 0.037초

154kV XLPE 600㎟ 지중관로 수평배열 형태별 허용전류용량 산정에 관한 연구 (A Study on the Calculation of Transmission Current-Carrying Capacity by Horizontal Arrangement Type in the Installation Methods of 154kV XLPE 600㎟ Power Cable Buried Ducts in Ground)

  • 김세동;유상봉
    • 조명전기설비학회논문지
    • /
    • 제30권3호
    • /
    • pp.53-58
    • /
    • 2016
  • The underground transmission lines which have been built to expand the suppling facilities will be continuously accompanying with high growth of the increase of power demand in the metropolitan area in recent years. So, it is necessary to maximize the ability and reliability of power supply with the current-carrying capability of the underground transmission lines. Design criteria of KEPCO is to be presented and used frequently. But it has to be studied about the installation methods of power cable buried in ground. In this study, we used the program for calculating the current-carrying capability of underground transmission power cables. We estimated the maximum permissible current values by the horizontal arrangement in the installation methods of power cable(154kV XLPE $600mm^2$) buried ducts in ground. To see the general tendency of the analysis, we researched a statistical analysis with such parameters as the maximum permissible current values. Through the regression analysis, we analyze the most highly values of the maximum permissible current on the Ra type duct arrangement.

XLPE의 계면형태에 따른 트리성장에 관한 연구 (A Study on the Tree Growth by Interface Type of XLPE)

  • 김철운;김영민;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.111-115
    • /
    • 1997
  • There exists a interface among the different kinds of materials in the solid insulating ones, which effects on the insulating capability heavily. The insulating construction has been developed for each usages and take themselves into several sorts. The conjunction between CV cables have the electrical weakness of solidity and solid interface, so they were focused at the long distance-line. To this background, it is very important to get the information on the interface influencing on the insulating capability of cable and to observe its procedure. In this paper, the interface was made artificially to research the effect owing to the toughness of interface, which results in the aging and treeing proceeding was observed. The polyethylen, as is generally using for the cable, was taken in this research.

  • PDF

극 초고압 케이블 및 접속함 전기 시험 단말의 개발 (DEVELOPMENT OF ELECTRICAL TESTING FACISITY ABOUT U.H.V. CABLE AND ACCESSORY)

  • 김정훈;오응종;김화종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2014-2016
    • /
    • 2000
  • In order to meet recent increasing demand for electric power in large cities, plans are being made to introduce 345kV lines into large urban areas. Up to now, OF cables have been used for 345kV fines, but nowadays XLPE insulated cables are preferred as they are easier to maintain due to phenomenal advances in plastic insulation technology, therefore cable manufacturing companies are trying to improve the performance and reliability of UHV CV cables and their accessories. For the purpose, our company has developed facilities for testing UHV cables. In this paper, we describes the methodology adopted for the design and development of a test termination, conducted the electrical test of UHV cables. Based on detailed analytical studies for electrical field distribution, the internal electrical design for the testing end has been carried out.

  • PDF

전력케이블 진단을 위한 부분방전 검출장치의 설계 및 제작 (Design and Fabrication of a PD Detector for Power Cable Diagnosis)

  • 송재용;서황동;길경석;한문섭;장동욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.777-782
    • /
    • 2005
  • In this paper, we designed and fabricated a partial discharge (PD) detector to diagnose the soundness of CNCV cables by analyzing PD pulses and to predict discharge locations. The PD detector is consisted of a coupling network with a discharge free capacitor and a detection impedance, a voltage follower and a low noise amplifier. Lower cut-off frequency of the detector is adjusted at 175kHz to block AC voltage and to pass discharge pulse only. The discharge location could be obtained by the time of arrival method using travelling wave propagation theory. In a laboratory test on an eighty meter CV cable, we could position the discharge location within a two meter error.

  • PDF

전력케이블의 경년열화에 따른 난연성에 관한 연구 (A Study on the Flame Retardancy According to the Aging of Power Cables)

  • 이해평;김해림;박영주;송사금
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 추계학술발표회 자료집
    • /
    • pp.358-361
    • /
    • 2010
  • 본 연구에서는 공동지하구 내에서 고온다습하고 유해가스 등 밀폐된 환경에서 사용되었던 CV-Cable을 대상으로 예상되는 Cable sheath 열화기간을 사용기간별(G전선 29년, L전선 14년, L전선 10년)로 3단계로 구분하여 콘칼로리미터와 UL 94 분석장비 등을 활용하여 착화시간, 총발열량, 연소속도를 측정함으로써 전력케이블의 경년열화에 따른 난연성을 비교분석하였다.

  • PDF

전력 케이블 절연재 적용을 위한 HDPE/EVA 혼합수지의 열적, 기계적 특성 고찰 (Investigation on Thermal and Mechanical Characteristics of HDPE Mixed EVA Applied for Power Cable Insulation)

  • 이한주;정의환;윤재훈;임기조;이흥규
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.85-85
    • /
    • 2010
  • In this paper, each specimen blended at weight proportions of 80% HDPE to 20% EVA, 70% HDPE to 30% EVA, 60% HDPE to 40% EVA, and 50% HDPE to 50% EVA was manufactued respectively. FE-SEM, DSC and XRD analysis were carried out as the means of structural and chemical analysis. From the results of DSC and XRD analysis, the lower contents in blended specimens were, the higher melting temperature and crystallinity of main crystal were. It seems that the phenomena was attributes to themoplastic interpenetrating network effect(TPIPN) in which EVA having low melting point penetrated into HDPE. Also, from the decreasing tendeancy of melting point as a function of blend ration, it was confirmd that above resins have compatibility. The thermal and mechanical performance of proposed insulator were compared with conventional XLPE, main insulating material of CV cable. Also, validity was proved by superior and inferior factor respectively.

  • PDF

고전력 활선 XLPE 케이블의 열화를 측정하기 위한 판정기준의 적용 및 절연상태 판정 (Application of Judgement Criteria to Measure Deterioration and to Judge Insulation Resistance in High-Power Live XLPE Cables)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권2호
    • /
    • pp.239-244
    • /
    • 2017
  • 전력 수요는 매년 증가추세에 있으며, 이에 따라 발전소에서 동작하는 모든 장비들과 대용량의 장거리 전력수송을 위한 장비들은 신뢰할 수 있는 수준에서 완전한 상태로 동작하여야 한다. 발전소에서 생산한 고전압 전력을 전달하기 위해 사용하는 케이블은 주로 6.6 kV XLPE 케이블(또는 CV케이블)이다. 제작 기술, 설치환경 및 사용조건에 다르겠지만, 케이블은 동작함과 동시에 열화과정이 진행된다. 접속재의 경우, 제조 결함이나 공사 결함이 있는 경우 대체로 동작 후 약 3 년 내에 고장을 일으키며, 그렇지 않는 경우 수명이 20-30 년을 지속하는 경우가 많다. 우리는 케이블의 열화 상태를 감시하기 위한 장비를 개발하여 충남 태안의 한국서부발전주식회사(Korea Western Power Co. Ltd.)에 설치하였다. 우리는 이 논문에서 케이블의 열화 판정의 기준을 설정하고, 기준에 따른 열화정도를 판정하고, 케이블의 대체여부를 결정함으로써 발전소에서 설치된 활선 케이블의 동작 상태를 감시한 결과와 케이블을 구성하고 있는 절연체와 방식층이 절연저항 특성에 미치는 영향 및 케이블의 동작에 미치는 영향을 연구한 결과를 제시한다.

터빈 발전기 부하용 XLPE 6.6kV 케이블의 절연층 절연상태와 습도의 상관관계 (Relationship Between Humidity and Insulation Status of XLPE 6.6kV Cables for the Load of Electric Turbine Generator)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권5호
    • /
    • pp.185-190
    • /
    • 2016
  • 국내 발전소에서 운전 중인 XLPE 케이블(또는 CV케이블)은 많은 경우 포설된 지 40년에 이르고 있다. 설치 후 운전 상태에 있는 대부분의 CV 케이블은 6~8년의 기간이 경과하면 열화가 발생하기 시작하고, 근래에 포설한 케이블이라 할지라도 사고가 발생할 수가 있으며, 사고 발생으로 인하여 막대한 손실을 초래하게 된다. 사고를 미연에 방지하기 위하여 케이블의 동작상태를 정기적으로 감시 확인하여야 한다. 우리는 케이블의 사고를 체계적으로 감시 및 예방하기 위한 목적으로 측정 시스템을 개발하였다. 이 장비는 수 년 동안 충남 태안에 소재한 한국서부발전주식회사(Korean Western Power Co. Ltd.)에서 케이블의 동작 상태를 감시하고 있다. 이 논문에서 시스템의 기능 및 동작 원리를 소개하고, 터빈 발전기 부하용 XLPE 고압케이블의 절연층 절연상태와 습도의 상간관계를 제시한다.

HDPF/EVA혼합수지의 혼합 비율에 따른 전기트리특성 연구 (Investigation on Electrical Tree Characteristics blended at weight of HDPE Mixed with EVA)

  • 정의환;윤재훈;이승수;임기조;이흥규
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.264-265
    • /
    • 2009
  • In this study, each specimen blended at weight proportions of 80% HDPE to 20% EVA, 70% HDPE to 30% EVA, 60% HDPE to 40% EVA, and 50% HDPE to 50% EVA was manufactured respectively. FE-SEM analysis were carried out as auxiliary analysis means. The insulation performances of the proposed insulator were compared with conventional XLPE, main insulating material of CV cable on the basis of the investigation results of AC insulation performances.

  • PDF

HDPE/EVA혼합수지의 전기적 분포 특성에 관한 연구 (A study on Electrical Potential Characteristics of HDPE Mixed with EVA)

  • 정의환;허준;이승수;임기조;이흥규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1447_1448
    • /
    • 2009
  • In this paper, each specimen blended at weight proportions of 80% HDPE to 20% EVA, 70% HDPE to 30% EVA, 60% HDPE to 40% EVA, and 50% HDPE to 50% EVA was manufactured respectively. The insulation performances of the proposed insulator were compared with conventional XLPE, main insulating material of CV cable on the basis of the investigation results of DC insulation performances. From the space charge density, electric field and potential profiles with raising DC voltage and time variation in HE82, distortion of electric field distribution was improved. As EVA mixed into the bulks acts as nucleation in crystallization process of HDPE, the size of spherulites became decreased and finally formed continuous network structure. Ultimately it resulted from extinction of space charge in the interfacial region of spherulites.

  • PDF