• 제목/요약/키워드: CUP1

검색결과 679건 처리시간 0.032초

컵드로잉에 의한 판재의 마찰특성 평가 (A Cup Drawing Test for Measuring the Coefficient of Friction in Sheet Metal Forming)

  • 김영석;최원집
    • 한국자동차공학회논문집
    • /
    • 제2권1호
    • /
    • pp.96-105
    • /
    • 1994
  • Cup drawing tests were performed to evaluate the friction characteristics of sheet metals. The linear relationship between drawing force and blank holding force obtained from the cup drawing test was used to calculate the coefficient of friction of the sheet metal. The friction coefficient was compared to that from conventional draw bead friction test. It was clarified that the cup drawing test can be used as a simple and convenient method for evaluating the friction characteristic of the sheet metal and also lubricity of the lubricant used.

  • PDF

Total Hip Arthroplasty with Cemented Dual Mobility Cup into a Fully Porous Multihole Cup with Variable Angle Locking Screws for Acetabular Fractures in the Frail Elderly

  • Mathias van den Broek;Kris Govaers
    • Hip & pelvis
    • /
    • 제35권1호
    • /
    • pp.54-61
    • /
    • 2023
  • Purpose: The purpose was to examine the clinical and radiological outcomes after surgical treatment of acetabular fractures with total hip arthroplasty with a dual mobility cup cemented into a porous multihole cup in the population of frail elderly patients. Materials and Methods: A retrospective review of 16 patients who underwent surgery (mean age, 76.7 years) with a mean follow-up period of 36.9 months was conducted. Following surgery, patients underwent postoperative follow-up at six weeks, three, six, and 12 months and clinical and radiological examinations were performed. Results: Classification of fractures was based on the Letournel classification. Following surgery, all patients were allowed weight-bearing as tolerated immediately postoperative. Fourteen patients showed maintenance of preoperative mobility status at one year. The mean Harris hip score was 64.8 (range, 34.7-82.8) and 80.0 (range, 60.8-93.8) at three months and one year, respectively. The mortality rate was 12.5% at one year (2/16). Complications included heterotopic ossification (2/16), deep venous thrombosis (1/16), heamatoma (1/16), and femoral revision due to a Vancouver B2 fracture (1/16). No case of deep infection, dislocation, or implant loosening was reported. Conclusion: Total hip arthroplasty using a dual mobility cup cemented into a porous multihole cup with locking screws resulted in a stable construct with a capacity for immediate weight-bearing as tolerated with rapid relief of pain. The findings of this study suggest that this procedure can be regarded as a safe method that has shown promising clinical and radiological outcomes for treatment of patients with medical frailty.

성인여성용 브래지어 원형 개발연구(제2보) -패턴그레이딩을 중심으로- (A Study on the Development of Basic Brassiere Pattern for Adult Women(Part II)-Focusing on Pattern Grading-)

  • 박은미;손희순
    • 한국의류학회지
    • /
    • 제26권6호
    • /
    • pp.821-832
    • /
    • 2002
  • The purpose of this study was to develop grading method of the basic brassiere patterns therewith, provide for 12 size's brassiere patterns and prove fitness of their's and shape. The collected data were statistically processed using the SAS 6.12 for Means, Standard Deviation, etc. The results of this study can be summarized as follows; 1. The basic sizes adopted at the first design stage (see fig.1-2) were 75AA, 75A and 75B each of which was designed as upper foundation basic pattern in reference to the cup size. At the second stage, each of the upper body foundation basic pattern was used to design lower cup, upper up, front panel and wing in their order(see fig.3-6). At the third stage, the other sizes were graded in reference to the three brassiere patterns (75AA, 75A and 75B) to produce 12 brassiere sizes(see Tab. 7-8). In order to develop the basic patterns of adult women's brassieres, 33 women were selected per 11 size combination(3 women per size combination), and then, their brassiere fitting was teated. As a result, the fronts of the basic patterns were found to have such problems as undone front center, poor levelling of upper cup's bottom line or lower cup's top line, poor shape of upper cup's outside top line and shoulder strip position. On the other hand, on the rear side of the basic patterns, the central part of the wing was slightly lifted, while the wing width and straps'interval did not befit the ful1-cup brassiere. The result of this first brassiere fitting test showed that the functionality and aesthetics of the basic pattern brassieres were more or less satisfactory, and thus, the problems were addressed for the second teat. In the second test, the aesthetics, breast-shaping effect and functionality of the basic pattern brassieres were much improved. 2. We were to present the final brassiere sizing system to extend the interior length of breast and the exterior length of breast on the basis of fitting test. Thereby, 75B$.$80A$.$80B$.$85A$.$85B's the interior lengths of breast were enlarged to 0.7cm, the rest size was enlarged to 0.5cm and the exterior length of breast was enlarged to 0.5cm regardless of sizes. 3. The upper foundation basic patterns of 75AA and 75B were presented and and the basic brassiere pattern and grading pattern were presented through to.

여성에서 남성 성전환자의 유방크기에 따른 유방절제방법 (Mastectomy Method according to the Breast Size in the Female to Male Transgenders)

  • 양진일;박수성;이근철;김석권
    • Archives of Plastic Surgery
    • /
    • 제38권1호
    • /
    • pp.63-68
    • /
    • 2011
  • Purpose: Mastectomy is one of the operative procedures of female to male transsexuals. It is aimed to excise all of breast tissues and to reconstruct male chest wall, areola, and nipple. Breast sizes are varied by developmental status and their hormonal therapy. There are several approaches for mastectomy. This study is aimed to suggest appropriate mastectomy methods according to breast size in the female to male transgenders. Methods: We retrospectively analysed 46 patients of female to male transgenders. Breast size was categorized by their inner wear size. In A cup size, mastectomy was done with periareolar approach. In C cup size, inframammary fold approach subcutaneous mastectomy was performed. In B cup size, periareolar approach was used for grade A or B ptosis patient, and inframammary fold approach was choosen for the patient with grade C ptosis. Results: Subcutaneous mastectomy was done through semicircular periareolar approach for 26 patients. There were 2 cases of major complications that should be corrected by hematoma evacuation. Circumareolar approach was used for 5 patients, and a case of nipple-areolar complex necrosis was observed. Two cases of another complications which were irregularity of breast and wound disruption could be corrected. Inframammary fold approach was selected for 15 patients. There was a case of wound disruption, so revision surgery whould be done. Four cases of breast irregularity was corrected spontaneously, and 2 cases of partial necrosis of nipple-areolar complex were corrected with secondary healing. Patient satisfaction score for periareolar, cicumareolar, and inframmammary fold approach were 4.5, 4.2 and 4.1, respectively. Some major and minor complications were observed, but satisfactory results could be secured. Conclusion: Semicircular periareolar incision looked adequate for A cup size patient, circumareolar incision was suitable for B cup size with grade A or B ptosis. In B cup size with grade C ptosis patient and C cup patients, inframammary fold incision looked suitable for optimal results.

브래지어 디자인에 대한 시각적 감성연구(제2보) (A study on the visual sensibility of brassiere design(Part II))

  • 하수진;이경희
    • 한국의류학회지
    • /
    • 제23권6호
    • /
    • pp.767-775
    • /
    • 1999
  • The purpose of this study is to investigate the visual sensibilities of brassiere design. Brassieres were divided into three types according to connection of a cup and a strp. In each type Lace was used where the part of the cup divided by Lines which were constructed such as a mold a horizontal a vertical a mixed and an oblique design. As a result 39 brassieres were obtained. The experiment has been done for seven groups which were divided by the type line and lace with 5 semantic differential bi-polar scales and 10 specialists. The data was analyzed using the statistical SPSS package. The major findings of this research were as follows. An oblique design line in the brassiere were effective in making the breast look bigger more buxom and more voluminous. To make the breast look small and unvoluminous the use of a mold in the 1/2 cup brassiere was effective. Also a mold using lace ion the 1/2 cup brassiere had an effect in making the breast look flatter and broader.

  • PDF

반구형 극소 드로인 제품의 두께분포 비교 (Thickness Distribution of Hemispherical Cup in Meso-Scale Deep Drawing Process)

  • 이기성;정효기;김종봉;김종호
    • 소성∙가공
    • /
    • 제20권1호
    • /
    • pp.36-41
    • /
    • 2011
  • Meso-scale or micro-scale forming of sheet metal parts has been recently considered as one of the important forming technologies with growing demand on meso/micro products for electric or medical devices. Experimental investigation on the cylindrical meso-cup drawing with hemispherical punch is carried out to examine the limit drawing ratio and thickness distribution of drawn cups. The working parameters chosen in this study are blank diameter, die-corner radius and blankholding force. It is found from the experiments that the limit drawing ratio of 2.4 can be achieved in the case of hemispherical cup drawing and uniform thickness distribution in wider region can be obtained compared with the results of conventional cup drawing.

중국 성인여성의 유방유형에 따른 브래지어 패턴 비교 (Comparison of Brassiere Pattern according to breast shape on China Adult Females)

  • 차수정;손희순
    • 패션비즈니스
    • /
    • 제15권1호
    • /
    • pp.63-79
    • /
    • 2011
  • This study examines the relationship between breast shape and brassiere construction through the comparative analysis of brassiere pattern on the breast shape. This researcher drew the brassiere pattern of developing a pre-study for Chinese female adults according to average size based on the four breast shapes. And then we measures brassiere pattern size and comparatively analyzes breast between size and shape. Comparative analysis results of brassiere patterns are verified differences of size and shape on the breast shape. Above all an angle of cup dart showed remarkable differences on the breast shape. An angle of cup dart isn't proportioned to breast size. An angle of cup dart for cone shape is bigger than dome shape. Because cone shape breast is protruded center part but dome shape breast have a shape of smooth curve like a half globe. So an angle of a cone shape breast cup dart is determined bigger than dome shape breast. For increasing the uplift effect of brassiere, brassiere pattern is different on the breast shape. And a brassiere pattern need different drawing methods about the angle of cup dart, breast inner side diameter, slope and so on. This study has an important significance that it established a mechanical relationship of breast shape and brassiere pattern.

방향족탄화수소의 인화점과 연소점 측정 및 예측 (Prediction and Measurement of Flash Point and Fire Point of Aromatic Hydrocarbons)

  • 하동명;한종근
    • 한국가스학회지
    • /
    • 제9권3호
    • /
    • pp.21-26
    • /
    • 2005
  • 인화점과 연소점은 가연성 물질의 화재 및 폭발 위험성을 결정하는데 가장 중요한 연소 특성치 가운데 하나이다. 본 연구에서는 방향족탄화수소에 대해 Pensky-Martens 밀폐식 장치(ASTM-D93) Tag 개방식장치(ASTM D1310-86)를 이용하여 인화점을 측정하였고, Tag 개방식 장치를 이용하여 연소점을 측정하였다. 측정된 인화점은 문헌값들과 일치하였으며, 연소점은 화학양론계수의 1.23배를 근거로 예측 값과 비교한 결과, 제시된 식은 실험값과 잘 일치하였다.

  • PDF

TFT-LCD 백라이트 유닛(BLU) 램프용 전극 미세 접합부의 강도 및 미세조직 (Microstructure and Strength of the Microjoined Electrode for the Lamp of the LCD Backlight Unit)

  • 김광수;김상덕
    • 한국재료학회지
    • /
    • 제19권1호
    • /
    • pp.7-12
    • /
    • 2009
  • TFT-LCD is the most popular type of flat display panel in the information technology field. The back light unit is a main part of the structure of a TFT-LCD panel. Occasionally, studies have shown that failures of the CCFL of the BLU occur due to the poor weld characteristics of these materials. The aim of this study was to prepare some technical data and to characterize a microjoined electrode for the CCFL. Microstructure examinations, microhardness measurements, resistance measurements and microtensile tests of the microjoined electrode were carried out. The result indicates that a large amount of grain coarsening exists in the heat-affected zone (HAZ) of the weld between the cup and the pin. This grain coarsening of the HAZ between the cup and pin is caused by the welding cycle, which may have an influence on the lowest microhardness values. Fracturing of the microjoined electrode also occurred at the HAZ close to the cup between the weld holding the cup and the pin. Additionally, no specific changes of the electrical resistance among the cup, pin, and lead wire themselves or in the microjoined electrode were observed.

Pressure Changes During Layer Cupping in a Skin Model

  • Shim, Dong Wook;An, Soo Kwang;Lee, Ha Lim;Lee, Jae Yong;Lee, Byung Ryul;Yang, Gi Young
    • Journal of Acupuncture Research
    • /
    • 제38권2호
    • /
    • pp.159-164
    • /
    • 2021
  • Background: Cupping is widely used in Korean medicine, but there is a risk of bacterial infection if the suction pump (used for inducing negative pressure) and the patients' skin are not separated. This study aimed to investigate the effect of layer cupping by comparing the pressure changes between layer cupping and conventional cupping. Methods: To evaluate pressure changes the study was designed with 3 types of conditions applied to a skin model: (1) a Dongbang cup with a manual or motor suction pump (conventional cupping); (2) layer cupping with 2 Dongbang cups; and (3) layer cupping with a cup made by 3D printing and a Dongbang cup. Results: When a manual suction pump was used (conventional cupping), the pressure did not decrease steadily, and in 1 section there was an increase in pressure. When layer cupping was used, the pressure in the lower cup (which would be directly applied to the patient's skin), decreased steadily. Conclusion: In the pressure change graph for layer cupping in this skin model, the pressure in the lower cup (which would be placed on the patient's skin) steadily decreased, and reached equilibrium. Therefore, the layer cupping model may help to reduce the risks of bacterial infection.