• Title/Summary/Keyword: CTS Test

Search Result 59, Processing Time 0.044 seconds

Neuromodulation of the median nerve in carpal tunnel syndrome, a single-blind, randomized controlled study

  • Gevher Rabia Genc Perdecioglu;Mehlika Panpalli Ates;Damla Yuruk;Omer Taylan Akkaya
    • The Korean Journal of Pain
    • /
    • v.37 no.1
    • /
    • pp.34-40
    • /
    • 2024
  • Background: This study aimed to evaluate the efficacy of pulsed radiofrequency applied using transcutaneous electrodes in carpal tunnel syndrome (CTS). Methods: After randomization, the patients received two cycles of noninvasive pulsed radiofrequency (NiPRF), once weekly, or splinting (the control group) for three months. Clinical evaluations were recorded at baseline and weeks 4 and 8. The Boston Carpal Tunnel Syndrome Questionnaire (BCTQ) was used to determine the functional status and symptom severity. Results: Sixty-two patients were followed up for three months. There was no difference between the groups in the BCTQ scores before and after treatment. The NiPRF group found a significant difference between the BCTQ measurements at all time intervals (paired sample t-test; P < 0.001). In the splint group, there was a significant difference only between the basal-1st month and basal-3rd month (paired samples t-test; P < 0.001). The main effect of the time variable was statistically significant (ANOVA; P < 0.001), but the group variable was not. There was no correlation between the BCTQ results measured at any time and the electroneuromyelogragphy findings in either group. Conclusions: NiPRF effectively improves symptoms and functionality in patients with CTS for up to 3 months. Thus, NiPRF can be considered an easy, safe, and useful alternative treatment modality for CTS.

Current Range Extension of Current Transformers by Using Absolute Evaluation Technique and Two Different Current Transformers (전류변성기 절대 평가 기술과 전류변성기 두 대를 이용한 전류 범위 확장)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.69-71
    • /
    • 2008
  • We have developed a current range extension method to obtain the ratio error and phase displacement of a current transformer (CT) by using absolute evaluation method and two different CTs. The method was applied to CTs under test with the current ratios of the range of 5,000 A / 1 A - 20,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Germany using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

  • PDF

Designing an Electronic Course and Its Impact on Developing University Students' Computational Thinking Skills

  • Al-Zahrani, Majed bin Maili bin Mohammad
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.1
    • /
    • pp.15-20
    • /
    • 2022
  • The study investigated the effects of differences in some electronic course designs on university students' Computational Thinking Skills (CTS). Towards this end, the researcher adopted the experimental research design of a quasi-experimental of two experimental groups. The first group was taught an e-course designed in a sequential pattern, and the other group's course was designed according to the holistic model. A CTSs test was prepared to collect the relevant data, and the data were analyzed statistically using these tests- Pearson correlation Mann Whitney and Alpha Cronbach. Results revealed statistically-significant differences at the level α=0.05 between the mean scores of the first and second experimental groups in favor of the latter in the CTS test. The findings gave ground to put forward some salient recommendations, including the need to expand computational thinking in universities' educational process. It also recommends urging faculty members to enhance e-courses in the educational process and provide technical support to students and faculty members.

Study on the Validity of F wave for Diagnosis of Carpal Tunnel Syndrome (손목터널증후군 진단 시 F파의 유용성에 관한 연구)

  • Park, Jong-Kwon;Kang, Ji-Hyuk;Kim, Hye-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.290-298
    • /
    • 2017
  • This study compared the median nerve, ulnar never, and F waves of patients diagnosed with early Carpal Tunnel Syndrome to a control group to determine whether F waves could be a useful indicator in the diagnosis of early CTS. The terminal motor latency (TML), terminal motor amplitude and sensory nerve conduction velocity (SNCV) of the section from the palms to the wrists, which are the key indicators to use in a nerve conduction study, and F waves were compared with the control group using the t-test. A correlation analysis was performed to analyze the correlation between the main indicators. The comparison between the median nerve's TML of the early CTS patients and that of the control group shows that there are 2 sections which have high significance (p<0.001). In the comparison of the SNCV of the median nerve between the control group and early CTS patients, high significance was observed (p<0.001). In the analysis of the F waves, there was high significance (p<0.001) between the control group and early CTS patients for the median nerve, but not for the ulnar nerve. The correlation analysis revealed that both the SNCV-TML and F wave-TML had significance. These results suggested that, along with TML and SNCV, F waves can be a useful indicator to diagnose CTS.

Avionics Software Data Modeling Method and Test For FACE Conformance (FACE 적합성을 위한 항공전자 소프트웨어 데이터 모델링 방안 및 검증)

  • Kyeong-Yeon, Cho;Doo-Hwan, Lee;Sang-Cheol, Cha;Jeong-Yeol, Kim
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.6
    • /
    • pp.45-53
    • /
    • 2022
  • The avionics industry has recently adopted an open architecture to increase software portability and reduce the development schedule and cost associated with changing hardware equipment. This paper presents a data modeling method compliant with FACE, a widely used open avionics architecture. A FACE data model is designed and implemented to output data from VOR/ILS avionics equipment. A FACE Conformance Test Suite (CTS) program is utilised to verify that the data model meets FACE standards. The proposed data modeling method is expected to improve the development schedule and cost associated with modifying communication methods and ICDs (Interface Control Documents).

Distance relay using the current transformer compensating algorithm (변류기 보상 알고리즘을 적용한 거리계전기)

  • Kang, Yong-Cheol;Lee, Hyun-Woong;Jang, Sung-Il;Kim, Yong-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.501-502
    • /
    • 2007
  • This paper describes a distance relay that operates in conjunction with a current transformer (CT) compensation algorithm. A distance relay detects a fault based on the ratio of the voltage to the current. If a CT saturates, the calculated impedance becomes larger. This causes maloperation or operating time delay of the distance relay. A compensating algorithm estimates the correct secondary current from the severely distorted currents even when the measurement CTs are used. The correct current is estimated by adding the calculated magnetizing current to the measured secondary current. Test results show that the proposed distance relay can detect a fault without the operating time delay even when the secondary currents are extremely distorted because of use of measurement CTs.

  • PDF

Establishment of National Standard System for 20.000 A Current Transformer (20,000 A 전류변성기 국가표준 시스템 구축)

  • Jung, Jae-Kap;Lee, Sang-Hwa;Kang, Jean-Hong;Kim, Myung-Soo;Kim, Yoon-Hyoung;Han, Sang-Gil;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.6-13
    • /
    • 2008
  • National standard system for calibrating current transformer(CT) up to primary current of 20,000A have been established. The system consists of 20,000 A AC high current source, CT comparator, standard CT, CT under test and CT burden. An AC high current is applied tn the primary windings of both the standard CT and the CT under test, and then the CT comparator measures the ratio error and the phase displacement by comparing the secondary currents of the two transformers. As a validity check for 20,000 A CT calibration system, the comparison with the two national standard institutes(NMIs) has been performed using same CTs. The comparison results of the CTs are consistent with those measured at two NMIs within 0.004 % for ratio error and 0.1 min for phase displacement in the primary current ranges of Ip = 10 - 20,000 A with a secondary current of Is = 5 A.

Predictive Value of Sensory Nerve Conduction in Carpal Tunnel Syndrome

  • Park, Sa-Kyuk;Lee, Jung-Ho;Lee, Hyuk-Gee;Ryu, Kee-Young;Kang, Dong-Gee;Kim, Sang-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.6
    • /
    • pp.401-405
    • /
    • 2006
  • Objective : Electrodiagnostic test has shown diagnostic sensitivity and specificity in carpal tunnel syndrome[CTS]. This study was to evaluate the correlation between clinical outcome of endoscopic carpal tunnel ligament release[ECTR] and the predictive value of sensory nerve conduction. Methods : From January 1998 to December 2004, 87 patients [44 right hand, 37 left hand, 6 bilateral hands] with CTS who underwent ECTR were followed up in our hospital for an average of 24 months. We retrospectively analyzed the results with previous medical records. All patients underwent electrodiagnostic test and ECTR. The patients were divided into three groups according to the electrodiagnostic test results. Group [A] was normal sensory nerve response, Group [B] was slowing sensory response and Group [C] was no sensory response. Improvement of the symptom after ECTR was assessed using a visual analogue scale[VAS] score. Results : Differences between the three groups on the correlation of severity of sensory potential and duration of preoperative symptoms were significant. The mean value of improved VAS scores for the three groups were $6.0{\pm}0.96$ in the Group A, $6.11{\pm}0.48$ in the Group B and $6.14{\pm}0.53$ in the Group C. There was no statistically significant difference between the severity of sensory nerve response and improvement in VAS score after ECTR. Complications included a wound infection, a case of skin necrosis, and two patients with persistent symptoms without any improvement. Conclusion : Although electrodiagnostic test has been known to be useful, sensory nerve response is considered not to be a good prognostic value for carpal tunnel syndrome after ECTR.

Quantitative Evaluation of Median Nerve Motor Function in Carpal Tunnel Syndrome Using Load Cell : Correlation with Clinical, Electrodiagnostic, and Ultrasonographic Findings

  • Kim, Dong Hwan;Park, Sung Bae;Lee, Sang Hyung;Son, Young-Je;Chung, Gih Sung;Yang, Hee-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.3
    • /
    • pp.232-235
    • /
    • 2013
  • Objective : Major complaints of carpal tunnel syndrome (CTS) are sensory components. However, motor deficit also impedes functional status of hand. Contrary to evaluation of sensory function, the objective, quantitative evaluation of median nerve motor function is not easy. The motor function of median was evaluated quantitatively using load cell and its correlation with findings of electrodiagnostic study (EDS) was evaluated. Methods : Objective motor function of median nerve was evaluated by load cell and personal computer-based measurement system. All of the measurement was done in patients diagnosed as having idiopathic CTS by clinical features and EDS findings. The strength of thumb abduction and index finger flexion was measured in each hand three times, and the average value was used to calculate thumb index ratio (TIR). The correlation of TIR with clinical, EDS, and ultrasonographic findings were evaluated. Results : The TIR was evaluated in 67 patients (119 hands). There were 14 males and 53 females, mean age were 57.6 years (range 28 to 81). The higher preoperative nerve conductive studies grade of the patients, the lower TIR was observed [p<0.001, analysis of variance (ANOVA)]. TIR of cases with thenar atrophy were significantly lower than those without (p<0.001, t-test). TIR were significantly lower in patients with severe median nerve swelling in ultrasonography (p=0.042, ANOVA). Conclusion : Measurements of median nerve motor function using load cell is a valuable evaluation tool in CTS. It might be helpful in detecting subclinical motor dysfunction before muscle atrophy develops.

Gold/Copper Bi-Metallic Catalysts by Carbothermal Method for CO2 Reduction

  • Yoon, Hee-chan;Jung, Woo-bin;Jung, Hee-Tae
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2019.10a
    • /
    • pp.83-83
    • /
    • 2019
  • Increasing the CO2 concentration in the atmosphere induce high temperature and rising sea levels. So the technology that capture and reuse of the CO2 have been recently become popular. Among other methods, CRR(CO22 reduction reaction) is typical method of CO2 reusing. Electrocatalyst can show more higher efficiencies in CRR than photocatalyst because it doesn't use nature source. Nowadays, finding high efficient electrocatalyst by controlling electronic (affected by stoichiometry) and geometric (affected by atomic arrangement) factors are very important issues. Mono-atomic electro-catalyst has limitations on controlling binding energy because each intermediate has own binding energy range. So the Multi-metallic electro-catalyst is important to stabilize intermediate at the same time. Carbon monoxide(CO) which is our target product and important feedstock of useful products. Au is known for the most high CO production metal. With copper, Not only gold/copper has advantages which is they have FCC packing for easily forming solid solution regardless of stoichiometry but also presence of adsorbed CO on Cu promotes the desorption of CO on Au because of strong repulsion. And gold/copper bi-metal catalyst can show high catalytic activity(mass activity) although it has low selectivity relatively Gold. Actually, multi-metallic catalyst structure control method is limited in the solution method which is takes a lot of time. In here, we introduce CTS(carbo thermal shock) method which is using heat to make MMNP in a few seconds for making gold-copper system. This method is very simple and efficient in terms of time(very short reaction time and using carbon substrate as a direct working electrode) and increasing reaction sites(highly dispersed and mixing alloy structures). Last one is easy to control degree of mixing and it can induce 5 or more metals in one alloy system. Gold/copper by CTS can show higher catalytic activity depending on metal ratio which is altered easily by changing simple variables. The ultimate goals are making CO2 test system by CTS which can check the selectivity depending on metal types in a very short time.

  • PDF