• Title/Summary/Keyword: CTS Test

Search Result 60, Processing Time 0.027 seconds

IMAGE FUSION ACCURACY FOR THE INTEGRATION OF DIGITAL DENTAL MODEL AND 3D CT IMAGES BY THE POINT-BASED SURFACE BEST FIT ALGORITHM (Point-based surface best fit 알고리즘을 이용한 디지털 치아 모형과 3차원 CT 영상의 중첩 정확도)

  • Kim, Bong-Chul;Lee, Chae-Eun;Park, Won-Se;Kang, Jeong-Wan;Yi, Choong-Kook;Lee, Sang-Hwy
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.5
    • /
    • pp.555-561
    • /
    • 2008
  • Purpose: The goal of this study was to develop a technique for creating a computerized composite maxillofacial-dental model, based on point-based surface best fit algorithm and to test its accuracy. The computerized composite maxillofacial-dental model was made by the three dimensional combination of a 3-dimensional (3D) computed tomography (CT) bone model with digital dental model. Materials and Methods: This integration procedure mainly consists of following steps : 1) a reconstruction of a virtual skull and digital dental model from CT and laser scanned dental model ; 2) an incorporation of dental model into virtual maxillofacial-dental model by point-based surface best fit algorithm; 3) an assessment of the accuracy of incorporation. To test this system, CTs and dental models from 3 volunteers with cranio-maxillofacial deformities were obtained. And the registration accuracy was determined by the root mean squared distance between the corresponding reference points in a set of 2 images. Results and Conclusions: Fusion error for the maxillofacial 3D CT model with the digital dental model ranged between 0.1 and 0.3 mm with mean of 0.2 mm. The range of errors were similar to those reported elsewhere with the fiducial markers. So this study confirmed the feasibility and accuracy of combining digital dental model and 3D CT maxillofacial model. And this technique seemed to be easier for us that its clinical applicability can good in the field of digital cranio-maxillofacial surgery.

APPLICATION OF A DUAL-ENERGY MONOCHROMATIC XRAY CT ALGORITHM TO POLYCHROMATIC X-RAY CT: A FEASIBILITY STUDY

  • Chang, S.;Lee, H.K.;Cho, G.
    • Nuclear Engineering and Technology
    • /
    • v.44 no.1
    • /
    • pp.61-70
    • /
    • 2012
  • In this study, a simple post-reconstruction dual-energy computed tomography (CT) method is proposed. A dual-energy CT algorithm for monochromatic x-rays was adopted and applied to the dual-energy CT of polychromatic x-rays by assigning a representative mono-energy. The accuracy of algorithm implementation was tested with mathematical phantoms. To test the sensitivity of this algorithm to the inaccuracy of representative energy value in energy values, a simulation study was performed with mathematical phantom. To represent a polychromatic x-ray energy spectrum with a single-energy, mean energy and equivalent energy were used, and the results were compared. The feasibility of the proposed method was experimentally tested with two different micro-CTs and a test phantom made of polymethyl methacrylate (PMMA), water, and graphite. The dual-energy calculations were carried out with CT images of all possible energy pairs among 40, 50, 60, 70, and 80 kVp. The effective atomic number and the electron density values obtained from the proposed method were compared with theoretical values. The results showed that, except the errors in the effective atomic number of graphite, most of the errors were less than 10 % for both CT scanners, and for the combination of 60 kVp and 70 kVp, errors less than 6.0 % could be achieved with a Polaris 90 CT. The proposed method shows simplicity of calibration, demonstrating its practicality and feasibility for use with a general polychromatic CT.

OpenGL ES 2.0 Emulation on Desktop PCs (데스크탑 상에서의 OpenGL ES 2.0 에뮬레이션)

  • Baek, Nakhoon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.4
    • /
    • pp.125-128
    • /
    • 2014
  • OpenGL ES(OpenGL for Embedded System) 2.0 is one of the most widely used 3D graphics API(application progrma interface) standard for smart phones and tablet PCs at this time. During programming with this API, they prefer desktop environment rather than the target mobile environment, which has relatively low computing power. Thus, we need to emulate the OpenGL ES 2.0 API on the desktop PCs, where only OpenGL API libraries are available. In this paper, we present technical difficulties and their solutions to emulate OpenGL ES 2.0 on desktop PCs. Our final implementation of OpenGL ES 2.0 emulation library works on desktop PCs and passed over more than 96% of the official CTS(conformance test suites) to prove the correctness of our implementation. Additionally, for the commercially available benchmark programs, our implementation shows equivalent execution speeds to the previous commercial OpenGL ES 2.0 implementations.

Effects of dentin surface preparations on bonding of self-etching adhesives under simulated pulpal pressure

  • Chantima Siriporananon;Pisol Senawongse;Vanthana Sattabanasuk;Natchalee Srimaneekarn;Hidehiko Sano;Pipop Saikaew
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.1
    • /
    • pp.4.1-4.13
    • /
    • 2022
  • Objectives: This study evaluated the effects of different smear layer preparations on the dentin permeability and microtensile bond strength (µTBS) of 2 self-etching adhesives (Clearfil SE Bond [CSE] and Clearfil Tri-S Bond Universal [CTS]) under dynamic pulpal pressure. Materials and Methods: Human third molars were cut into crown segments. The dentin surfaces were prepared using 4 armamentaria: 600-grit SiC paper, coarse diamond burs, superfine diamond burs, and carbide burs. The pulp chamber of each crown segment was connected to a dynamic intra-pulpal pressure simulation apparatus, and the permeability test was done under a pressure of 15 cmH2O. The relative permeability (%P) was evaluated on the smear layer-covered and bonded dentin surfaces. The teeth were bonded to either of the adhesives under pulpal pressure simulation, and cut into sticks after 24 hours water storage for the µTBS test. The resin-dentin interface and nanoleakage observations were performed using a scanning electron microscope. Statistical comparisons were done using analysis of variance and post hoc tests. Results: Only the method of surface preparation had a significant effect on permeability (p < 0.05). The smear layers created by the carbide and superfine diamond burs yielded the lowest permeability. CSE demonstrated a higher µTBS, with these values in the superfine diamond and carbide bur groups being the highest. Microscopic evaluation of the resin-dentin interface revealed nanoleakage in the coarse diamond bur and SiC paper groups for both adhesives. Conclusions: Superfine diamond and carbide burs can be recommended for dentin preparation with the use of 2-step CSE.

The Effect of Doctor's Payment Method on Practice Behavior (지불보상체계가 의사의 진료행태에 미치는 영향 : 미국사례 분석)

  • Lim Jae-Young
    • Health Policy and Management
    • /
    • v.14 no.4
    • /
    • pp.48-74
    • /
    • 2004
  • Considering the existence of asymmetric information between doctor and patient, the doctor's reimbursement method has been considered as a desirable policy device of improving efficiency of patient's use of medical care in terms of its affecting doctor's practice pattern by determining doctor's practice revenue. By using the Community Tracking Study (CTS) physician data set, which includes not only various information on doctors practice arrangements and sources of practice revenue, but also vignettes of various clinical presentations, this paper investigates doctor's reaction to the financial incentive under the control of patient's specific medical situation. Under the econometric model for exploring the effect of doctor's reimbursement method on his/her practice patterns; referring patients, recommend doctor-visit or medical tests, the Hausman's specification test was used for checking out the possibility of the doctor's reimbursement method being endogeneized explanatory variable. In the case where the endogeneity problem of doctor's reimbursement method exists, the 2SLS method was used for correcting that problem, and the multiple regression method was used in the case where the problem is found to be nonexistent. Based on the empirical results, this paper finds that doctors do appear to respond to financial incentive. The empirical results show that the doctor's reimbursement method statistically significantly affects doctor's practice pattern and are coincident with the theoretical result proposed by previous researches, This results suggest, as doctor's practice revenues are mainly determined by prospective method, such as capitation, doctors would more refer their patients to specialists, and hesitate in recommending doctor-visit or medical exam.

Assessment of a Deep Learning Algorithm for the Detection of Rib Fractures on Whole-Body Trauma Computed Tomography

  • Thomas Weikert;Luca Andre Noordtzij;Jens Bremerich;Bram Stieltjes;Victor Parmar;Joshy Cyriac;Gregor Sommer;Alexander Walter Sauter
    • Korean Journal of Radiology
    • /
    • v.21 no.7
    • /
    • pp.891-899
    • /
    • 2020
  • Objective: To assess the diagnostic performance of a deep learning-based algorithm for automated detection of acute and chronic rib fractures on whole-body trauma CT. Materials and Methods: We retrospectively identified all whole-body trauma CT scans referred from the emergency department of our hospital from January to December 2018 (n = 511). Scans were categorized as positive (n = 159) or negative (n = 352) for rib fractures according to the clinically approved written CT reports, which served as the index test. The bone kernel series (1.5-mm slice thickness) served as an input for a detection prototype algorithm trained to detect both acute and chronic rib fractures based on a deep convolutional neural network. It had previously been trained on an independent sample from eight other institutions (n = 11455). Results: All CTs except one were successfully processed (510/511). The algorithm achieved a sensitivity of 87.4% and specificity of 91.5% on a per-examination level [per CT scan: rib fracture(s): yes/no]. There were 0.16 false-positives per examination (= 81/510). On a per-finding level, there were 587 true-positive findings (sensitivity: 65.7%) and 307 false-negatives. Furthermore, 97 true rib fractures were detected that were not mentioned in the written CT reports. A major factor associated with correct detection was displacement. Conclusion: We found good performance of a deep learning-based prototype algorithm detecting rib fractures on trauma CT on a per-examination level at a low rate of false-positives per case. A potential area for clinical application is its use as a screening tool to avoid false-negative radiology reports.

Carpal Tunnel Syndrome among workers in a condom industry (한 콘돔공장근로자들의 수근관증후군에 관한 연구)

  • Kang, Joong-Koo;Paek, Do-Myung;Lee, Young-Jung;Ma, Hyeo-Il;Son, Mi-A;Lee, Hong-Ki;Choi, Jung-Keun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.507-519
    • /
    • 1996
  • The objectives of this study are to investigate the prevalence of occupation related carpal tunnel syndrome(CTS) among workers in a condom industry : to analyse the sensitivity and specificity of clinical signs or symptoms such as hand diagram, Tinel's sign and Phalen's sign in carpal tunnel syndrome : and to test vibration threshold test using audiometry as a technically easy and noninvasive method in the diagnosis of carpal tunnel syndrome in stead of nerve conduction velocity (NCV). The study group was divided into exposed group(39 cases) and non-exposed group(48 cases) based on whether or not excessive use of wrist movements exsist. 1. There are stastically significant differences in symptoms and signs of carpal tunnel syndrome such as hand diagram, Tinel's sign and Phalen's sign between exposed and non-exposed group(p<0.05). 2. Six cases(9 hands) were comfirmed as carpal tunnel syndrome by NCV. Five cases(7 hands) belonged to exposed group, 1 case(2 hands) to nonexposed group. As there are significant differences in prevalence of carpal tunnel syndrome between two groups(p<0.05), excessive use of wrist in occupation is a risk factor of carpal tunnel syndrome. 3. When we use NCV as a gold standard in the diagnosis of carpal tunnel syndrome, sensitivity and specificity of hand diagram, Tinel's sign and Phalen's sign is as followed; hand diagram , sensitivity 88.9%, specificity 84.2% Tinel's sign ; sensitivity 55.6%, specificity 72.8% Phalen's sign ; sensitivity 14.3%, specificity 88.4%. Among above clinical signs and symptoms, hand diagram is the best clinical screening test. 4. The differences of vibration threshold between median and ulnar nerve at the same time are useful in the diagnosis of carpal tunnel syndrome but the time change of vibration threshold of median nerve over time are not sensitive enough. It is concluded that vibration threshold between median and ulnar nerve at the same time can be used as a supplementary or alternative criterion to indicate that the nerve dysfunction is located in the carpal tunnel.

  • PDF

The Evaluation of Usefulness of Pixelated Breast-Specific Gamma Imaging in Thyroid scan (Pixelated Breast-Specific Gamma Imaging(BSGI) 감마 카메라를 이용한 갑상선 검사의 유용성 평가)

  • Jung, Eun-Mi;Seong, Ji-Hye;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.90-93
    • /
    • 2011
  • Purpose: A Pixelated BSGI gamma camera has features to enhance resolution and sensitivity and minimize the distance between detector and organs by narrow FOV. Therefore, it is known as useful device to examine small organs such as thyroid, parathyroid and gall bladder. In general, when we would like to enlarge the size of images and obtain high resolution images by gamma camera in nuclear medicine study, we use pinhole collimator. The purpose of this study is to evaluate the usefulness of Pixelated BSGI gamma camera and to compare to it using pinhole collimator in thyroid scan which is a study of typical small organs. Materials and methods: (1) The evaluation of sensitivity and spatial resolution: We measured sensitivity and spatial resolution of Pixelated BSGI with LEHR collimator and Infinia gamma camera with pinhole collimator. The sensitivity was measured by point source sensitivity test recommended by IAEA. We acquired images considering dead time in BSGI gamma camera for 100 seconds and used $^{99m}TcO4-\;400{\mu}Ci$ line source. (2) The evaluation of thyroid phantom: The thyroid phantom was filled with $^{99m}TcO4-$. After set 300 sec or 100 kcts stop conditions, we acquired images from both pixelated BSGI gamma camera and Infinia gamma camera with LEHR collimator. And we performed all thyroid studies in the same way as current AMC's procedure. Results: (1) the result of sensitivity: As a result, the sensitivity and spatial resolution of pixelated BSGI gamma camera were better than Infinia's. The sensitivities of pixelated BSGI and Infinia gamma camera were $290cps/{\mu}Ci$ and $350cps/{\mu}Ci$ respectively. So, the sensitivity of pixelated BSGI was 1.2 times higher than Infinia's (2) the result of thyroid phantom: Consequently, we confirmed that images of Pixelated BSGI gamma camera were more distinguishable between hot and cold spot compared with Infinia gamma camera. Conclusion: A pixelated BSGI gamma camera is able to shorten the acquisition time. Furthermore, the patients are exposed to radiation less than before by reducing amount of radiopharmaceutical doses. Shortening scan time makes images better by minimizing patient's breath and motion. And also, the distance between organ and detector is minimized because detector of pixelated BSGI gamma camera is small and possible to rotate. When patient cannot move at all, it is useful since device is feasible to move itself. However, although a pixelated BSGI gamma camera has these advantages, the effect of dead time occurs over 2000 cts/s since it was produced only for breast scan. So, there were low concentrations in organ. Therefore, we should consider that it needs to take tests to adjust acquisition time and amount of radiopharmaceutical doses in thyroid scan case with a pixelated BSGI gamma camera.

  • PDF

Effects of Exercise-Based Intervention Before and After Lung Cancer Surgery: A systematic review in pubmed database (허파암 수술 전과 후에 적용한 운동의 효과: PubMed 내 연구에 대한 체계적 문헌고찰)

  • Boram Oh;Heesu Kim;Sookyoung Park
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.2
    • /
    • pp.23-35
    • /
    • 2023
  • Purpose : Lung cancer induces a decrease in physical activity and a deterioration of respiratory ability. Exercise is an effective treatment to reduce side effects of anti-cancer treatments, also influence the survival and successful rehabilitation in lung cancer patients. However, there is insufficient evidence to show which period is the most effective to apply exercise for lung cancer patients. Therefore, this study was conducted to evaluate the efficacy of exercise-based interventions before and after surgery. Methods : Clinical trials (CTs) and randomized controlled trials (RCTs) reported in PubMed database were investigated. The trials investigated in this study were published for 10 years before August 20, 2022. The risk of bias was judged according to the Cochrane guideline. The materials included in this meta-analysis were 6-minute walk test (6MWT), pulmonary function, and quality of life (QOL). Results : 1 CT and 9 RCTs were selected in current study. In the meta-analysis, exercise increased 6MWT in preoperation (mean difference [MD] 29.49; 95 % confidence interval [CI] .99 to 57.99; p=.04; I2=0 %), 3 months postoperation (MD 54.97; 95 % CI 31.85 to 78.09; p<.001; I2=45 %) and 6 months postoperation (MD 85.59; 95 % CI 45.06 to 126.12; p<.001; I2=47 %). Exercise, also enhanced the lung function such as FEV1/FVC (%) in postoperation (MD 7.64; 95 % CI 6.26 to 9.02; p<.001; I2=19 %). Additionally, exercise improved QOL, such as preoperative EORTC-QLQ-C30-LC13 in mental function (MD 3.21; 95 % CI .64 to 5.79; p=.01; I2=0 %) and postoperative SF-36 in mental component summary (MD 9.24; 95 % CI 4.94 to 13.54; p<.001; I2=0%). Conclusion : These results indicate that exercise-based intervention can elevate the ability to exercise and the mental componentof QOL within 3 months.

Motivation for Alcohol Use, Problem Drinking, Family Alcohol Use and Dating Violence among College Students (음주 동기, 문제음주 및 음주 가족력과 대학생의 데이트 폭력)

  • Kyung Hyun Suh
    • Korean Journal of Culture and Social Issue
    • /
    • v.9 no.2
    • /
    • pp.61-78
    • /
    • 2003
  • The researcher examined the relationship between dating violence and drinking behaviors. Study participants included 440 Korean College students(184 males and 256 females) currently involved in heterosexual dating relationships. Participants' ages ranged from 17 to 30(M=20.08, SD=1.89). Questionnaires and psychological tests used included: Straus' Conflict Tactics Scale, Alcohol Use Disorder Identification Test(AUDIT), Cooper's Revised Drinking Motives Questionnaire(DMQ), and Index of Family Alcohol Use. Research designs were 2(gender) × 2(experience of inflicting dating violence), i.e. 2-way MANOVAs. Results suggest students who drink one or more times a week are more likely to commit acts of violence toward their dating partners than students drinking less often. The study revealed males tend to drink with higher social, enhancement, conformity and coping motives than females. The study also showed that students inflicting dating violence drank with higher coping motives than students who did not. Males showed more hazardous, dependent and harmful drinking patterns than females. Also, students who had inflicted dating violence showed a higher degree of these characteristics (hazardous, dependent and harmful drinking patterns) along with a greater family history of alcohol use than participants who had not inflicted dating violence. The findings showed significant 2-way interactions in dependent and harmful drinking patterns. Simple main effect analysis revealed that differences in dependent and harmful drinking patterns in males are more significant than the same differences in females.

  • PDF