• 제목/요약/키워드: CT26 cell

검색결과 97건 처리시간 0.028초

Evaluation of 99mTc-MAG3-2-nitroimidazole for hypoxic tumor imaging

  • Lee, Yun-Sang;Kim, Young Joo;Jeong, Jae Min
    • 대한방사성의약품학회지
    • /
    • 제5권1호
    • /
    • pp.18-25
    • /
    • 2019
  • 2-Nitroimidazole derivatives have been reported to accumulate in hypoxic tissue. We prepared a novel $^{99m}Tc-MAG_3$-2-nitroimidazole and evaluated the feasibility for hypoxia imaging agent. $Bz-MAG_3$-2-nitroimidazole was synthesized by direct coupling of $Bz-MAG_3$ and 2-nitroimidazole using dicyclohexylcarbodiimide. $Bz-MAG_3$-2-nitroimidazole was labeled with $^{99m}Tc$ in the presence of tartaric acid and $SnCl_2-2H_2O$ at $100^{\circ}C$ for 30 min. And the reaction mixture was purified by $C_{18}$ Sep-pak cartridge. The labeling efficiency and the radiochemical purity were checked by ITLC-SG/acetonitrile. The tumor was grown in balb/c mice for 8~13 days after the subcutaneous injection of tumor cells, CT-26 (murine colon adenocarcinoma cell). Biodistribution study and tumor autoradiography were performed in the xenografted mice after i.v injection of 74 kBq/0.1 mL and 19 MBq/0.1 mL of $^{99m}Tc-MAG_3$-2-nitroimidazole, respectively. In vivo images of $^{99m}Tc-MAG_3$-2-nitroimidazole in tumor bearing mice were obtained 1.5 hr post injection. The labeling efficiency was $45{\pm}20%$ and the radiochemical purity after purification was over 95%. Paper electrophoresis confirmed negative charge of $^{99m}Tc-MAG_3$-2-nitroimidazole. $^{99m}Tc-MAG_3$-2-nitroimidazole was very stable at room temperature and its protein binding was 53%. The $^{99m}Tc-MAG_3$-2-nitroimidazole exhibited high uptake in the liver, stomach and intestine. In biodistribution study using tumor bearing mice, the uptakes (% ID/g) of the tumor were $0.5{\pm}0.1$, $0.4{\pm}0.0$, $0.2{\pm}0.1$ and $0.1{\pm}0.1$ at 5, 15, 30 min and 4 hrs. Tumor/muscle ratio were $1.4{\pm}0.1$, $2.2{\pm}0.83$, $3.0{\pm}0.9$, and 3.7 (n=2) for 5, 15, 30 min and 4 hrs. The uptake in hypoxic area was found higher than in non-hypoxic area of tumor tissue by autoradiography. In vivo images showed the relatively faint uptake to the hypoxic tumor region. $^{99m}Tc-MAG_3$-2-nitroimidazole was successfully synthesized and found feasible for imaging hypoxia.

한국, 미국, 일본의 식도암 방사선 치료에 대한 PCS($1998{\sim}1999$) 결과의 비교 분석 (Comparative Analysis of Patterns of Care Study of Radiotherapy for Esophageal Cancer among Three Countries: South Korea, Japan and the United States)

  • 허원주;최영민;김정기;이형식;최석렬;김일한
    • Radiation Oncology Journal
    • /
    • 제26권2호
    • /
    • pp.83-90
    • /
    • 2008
  • 목적: 식도암의 방사선 치료에 대해 최초로 시행한 한국의 PCS의 결과를 토대로 미국, 일본에서 시행한 결과와 비교 분석하여 식도암 환자들의 특징, 진단 및 치료방침의 차이를 파악해 향후 범 국가적으로 활용할 시스템의 구축에 응용하고자 하였다. 대상 및 방법: 국내의 21개 병원의 방사선 종양학과에서 1998-1999년 동안 식도암으로 확진 된 후 방사선 치료를 받은 총 246명을 대상으로 하였다. 이 결과를 미국 59개 병원에서 식도암 환자 414명을 연구한 PCS 결과(Suntharalingam)와 비교 하였다. 또 일본의 76개 병원에서 수술과 방사선치료를 받았거나 수술, 방사선 치료, 항암제치료를 함께 받은 수술 군 환자 220명(Gomi), 수술을 받지 않고 방사선 치료만 시행하였거나 방사선 치료와 항암제치료를 함께 시행한 비 수술 군 환자 385명(Murakami)을 대상으로 시행한 PCS 결과와 비교 분석하였다. 결과: 환자들의 평균 연령은 일본의 비 수술 군이 가장 높았다(71세). 한국과 일본은 남성의 발생 빈도가 월등히 높았지만(9:1) 미국은 여성의 발생률이 23.1%였다. 한국과 일본은 편평상피세포암이 압도적으로 많았지만(한국 96.3%, 일본 98%) 미국은 선암이 더 많은 양상을 보였다(49.6%). 병기결정을 위한 검사는 식도 내시경, 흉부 컴퓨터 단층촬영, 식도조영술을 가장 많이 사용하였고 미국과 일본은 복부 컴퓨터단층촬영을 복부 초음파보다 더 자주 시행하였다. 치료방침을 분석한 결과 방사선 단독치료의 비율은 한국이 23.2%, 일본이 39%인데 반해 미국은 9.5%에 불과하였다. 수술과 방사선 및 항암치료를 병용한 빈도는 미국(32.8%)과 일본(49.5%)이 한국(11.8%)보다 높았다. 식도암 치료에 있어서 항암제 치료는 미국이 가장 높은 빈도로 사용되어졌고(89%) 동시항암방사선 치료도의 빈도도 미국이 가장 높았다(97%). 항암치료제는 3개국 모두에서 cisplatin과 5-FU를 가장 선호하였다. 방사선 조사량은 한국 55.8 Gy, 미국 50.4 Gy였고 일본은 수술 군(48 Gy)과 비 수술 군(60 Gy)이 현격한 차이를 보였다. 결론: 한국, 미국, 일본에서 시행된 식도암 환자의 PCS 결과를 분석하여 환자 및 종양의 특징, 진단 및 치료 방침에 다소간의 상이점을 발견하였다. 그러나 방사선 조사량과 조사야 수, 방사선치료 에너지의 종류 등 방사선 기술적인 부분은 3개국 모두에서 큰 차이를 보이지 않았다.

만성폐쇄성폐질환에서 우심실 기능 부전에 따른 혈액응고 및 섬유소용해계 변화 (Alteration of Coagulation and Fibrinolysis System According to Right Ventricular Dysfunction in Chronic Obstructive Pulmonary Disease)

  • 김영;장윤수;김형중;김세규;장준;안철민;김성규;곽진영;최진화
    • Tuberculosis and Respiratory Diseases
    • /
    • 제60권6호
    • /
    • pp.625-630
    • /
    • 2006
  • 배 경: COPD 환자에서 흡연은 폐혈관에 직접 작용하여 혈관 수축, 확장 및 혈관세포 증식을 조절하는 매개물질을 분비하여 혈관의 부적절한 개형 및 생리 현상을 초래하여 폐성고혈압을 유발한다. COPD 환자에서는 종종 급성 및 만성 폐혈전증이 일어나고 혈장내 응고전구물질 및 섬유소용해계의 표지자들이 증가되어 있다. 그러나 COPD 환자에서 혈액 응고계 및 섬유소용해계가 우심실 기능 장애에 어떤 기여를 하는지는 잘 알려져 있지 않다. 본 연구에서는 진행된 COPD 환자에서 multidetector CT scan (MDCT)을 이용하여 측정한 우심실 기능에 따른 혈액내 응고계 및 섬유소용해 계의 변화를 알아보고자 하였다. 방 법: GOLD 지침에 따라 COPD로 진단한 26명에서 심장 MDCT scan을 이용하여 우심실 박출계수를 구하였다. 혈액내 thrombin antithrombin (TAT) 및 plasminogen activator inhibitor (PAI)-1은 enzyme linked immunoassay 방법으로 측정하였다. 결 과: COPD 환자의 혈중 TAT는 $10.5{\pm}19.8{\mu}g/L$으로 정상인의 혈중 TAT $3.4{\pm}2.5{\mu}g/L$보다 의미 있게 증가되었으나 (p<0.01) COPD 환자의 혈중 PAI-1는 $29.6{\pm}20.7ng/mL$으로 정상인의 혈중 PAI-1 $25.9{\pm}17.9ng/mL$와 비교하여 의미 있는 변화가 없었다. COPD 환자에서 혈중 TAT는 MDCT scan으로 측정한 우심실 박출계수와 의미 있는 역 상관관계를 보였으나 (r=-0.645, p<0.01) 혈중 PAI-1은 우심실 박출계수와 상관관계를 보이지 않았다 (r=0.022, p=0.92). 결 론: COPD 환자에서 혈중내 응고계는 활성화되어 있으며 혈중 TAT는 우심실 기능 장애의 의미있는 표지자로 사료된다.

유육종증 전국실태조사 (National Survey of Sarcoidosis in Korea)

  • 대한결핵 및 호흡기학회 학술위원회
    • Tuberculosis and Respiratory Diseases
    • /
    • 제39권6호
    • /
    • pp.453-473
    • /
    • 1992
  • 연구배경 : 전국 실태조사를 통하여 현재까지 확진된 전국의 유육종증 발생현황을 파악하고 이를 분석하고 외국의 보고와 비교하여 일반 개업의 및 내과 전문개업의 진료활동에 도움이 되도록 하고자 하였다. 방법 : 조사와 분석기간은 1991년 1월부터 1992년 12월까지 2년간으로 정하였으며 자료수집방법은 후향적 방법으로 입원실이 100병상 이상인 213개 종합병원의 내과, 안과, 피부과, 신경내과에 서신을 통한 경험증례를 수집 하였으며 확진예나 의심예가 있었던 경우에 유육종증 증례 기록지를 보내어 정확한 임상 및 검사정보를 수집하여 분석하였다. 결과 : 1) 제 1 차 설문엽서 발송은 입원실이 100병상 이상인 213개 종합병원의 내과, 안과, 피부과, 신경내과의 523개과 과장 및 호흡기 내과를 담당하는 전문의에게 발송하였다. 내과가 213개과로 41%, 피부과가 1087개과로 20%, 안과가 104개과로 20%, 신경과가 100개과로 19%를 차지하였다. 2) 제 1 차 설문조사에 대한 답신은 241개과에서 연락이 있었다(48% 회신율). 3) 확진예 및 의심예는 총 50개과 113예 및 10예가 있다고 보고되었으며 내과가 92예로 81%, 피부과 15예로 13%, 안과, 신경과가 각 3예로 3%를 차지하였다. 자료분석은 총 78예에서 시행되었고 내과 72예로 92%, 피부과 4예로 5%, 신경과 2예로 3%를 차지하였다. 4) 1980년 1에보고 이후 증례가 많은 수로 증가하여 1989년 13예, 19901건 17예, 1991년 18예가 보고되었다. 5) 진단 당시의 연령은 20대, 30대, 40대가 84.4%로 대부분을 차지하고 있었다. 6) 남녀비는 1 : 1.5의 비율로 여자 환자가 많았다. 7) 진단을 받게된 동기로 주소의 빈도로는 호흡기 증상이 48%로 가장 많았고, 피부의 병변, 전신증상, 시각장애, 관절통, 복통, 연하곤란의 순서이었고 무증상이 12예(16%)이었다. 8) 초증상에서 확진을 받을때까지 중앙치는 2개월이었다. 9) 증상의 반도로는 호흡기 증상, 전신증상, 피부증상, 눈 증상, 말초림프구 종창, 신경계증상, 심장증상의 순이었다. 10) 말초혈액검사 소견상 혈색소, 혈구용적치 및 혈소판수는 대부분 정상범위를 나타냈다. 58%의 증례에서 30%미만의 림프구 감소증을 나타냈으며, 임파구 아형으로 T4/T8비는 1.73{\pm}1.16$(0.43~4.62)였다. 43%에서 혈침속도가 상승하였다. 11) 혈청 생화학검사는 대부분 정상범위를 이었다. 혈청 ACE 농도의 평균치는 $66.8{\pm}58.6$(8.8~265) U/L로서 46.2%에서 증가되었다. 42.9%에서 하루 150 mg 이상의 단백뇨 소견을 나타냈고, 36.8%가 하루 300 mg이상의 단백뇨 소견을 나타냈다. 12) 면역학적 검사상 혈청 IgG는 43.5%, IgA는 45.5%, lgM은 59.1%, IgE는 46.7%에서 상승되었고, C3 및 C4는 대부분 정상범위 였으며, ANA는 11%에서 양성을 보였다. Kveim test는 시행된 3예에서 모두 양성을 나타냈다. 13) 폐기능검사중 FVC는 80% 미만인 경우가 17.3%, FEV1은 70% 미만인 경우가 11.5% FEV1/FVC는 70% 미만인 경우가 10%, TLC는 80% 미만인 경우가 15.2%, DLCO는 100% 미만인 경우가 64.7%이었다. 14) 동맥혈가스 분석소견은 PaO2가 90mmHg 미만인 경우가 48.6%, PaCO2는 평균 45mmHg보다 증가된 경우보다 5.7%이었다. 15) 기관지 폐포세척액 검사상 대식세포의 평균 백분율은 $51.4{\pm}19.2%$였고, 임파구의 평균 백분율은 $44.4{\pm}21.1$이였다. 임파구아형은 T4/T8 ratio는 $3.41{\pm}2.07$이였다. 16) 전 검사항목에 대한 남녀 성별간의 유의한 차이는 없었다. 17) 흉부방사선의 분석에서 폐문 임파절 비대를 보인례는 87.9%였고, 78.8%에서는 양측성병변을 9.1%에 일측성 병변을 보였다. 18) Siltzbach의 분류에 의한 병기 구분시 stage 0 : 5%, stage 1 : 58.3%, stage 2 : 28.3%, stage 3 : 8.3%의 분포를 보였다. 19) 흉부 CT를 시행한 54예에서 폐문임파절비대는 50예(92.6%)에서 보였고 이들 중 47예는 양측성 비대였다. 20) 고해상도 CT는 16예에서 시행하였는데, 2예에서는 병변이 없었으며, 폐실질의 병변은 결정성 병변, 소엽간 중격비후, 반점상 국소 폐음영의 순으로 나타났다. 21) 부수적으로 시행한 방사선학적 검사에서 골병변은 1예에서 수근골의 병변을 보였고, 초음파검사에서 2에에서 비장비대의 소견을 보였다. 22) 갈륨스캔은 12에에서 시행하여 폐문 및 종격동 임파절의 흡수증가 소견이 8예에서 보였고, 폐장의 흡수증가는 2예에서 보였다. 23) 조직검사상 가장 많이 시행한 진단방법은 경기관지 폐생검 47.3%이었고, 피부와 종격동 임파절 생검은 각각 34.5%, 말초임파절생검 23.6%, 개흉 폐생검 18.2%, 기관지생검이 16.2%이었다. 2가지 이상의 부위에서 조직검사를 시행한 경우는 52.7%이었다. 한 부위에서만 조직검사를 시행한 26예중 종격동 임파절 생검은 10예, 피부생검 6예, 말초임파절 생검 5예, 개흉폐생검 3예 그리고 경기관지 폐생검 2예이었다. 24) 병리소견상 비건락성 육아종은 100% 모두에서 관찰되었며, 다핵거대 세포는 47.3%, 봉입체는 10.9%, 초자질 섬유화는 34.5%, 괴사 9.1%, reticulin fibrils network 20%, lymphangitic distribution of granuloma 1.8%에서 관찰되었다. 결론 : 유육종 전국 실태조사에 따른 영상소견, 검사실소견, 방사선소견, 병리소견을 분석해 본 결과, 우리나라 유육종 환자들도 다소 차이는 있었지만 외국의 보고들과 유사한 소견들을 나타냈으며, 향후로는 이들에 대한 결과들을 추가분석하여, 유육종 진단에 도움을 줄 수 있고, 임상적 지표로 이용될 수 있는 검사항목을 찾아내는 것이 과제라 할 수 있겠다. 유육종증에 대한 자료는 대한 결핵 맺 호흡기학회에 보관이 되어 있음을 알려드립니다.

  • PDF

절제 불가능한 제 3기 비소세포성 페암의 다분할 방사선 치료와 MVP 복합 항암요법의 동시 치료에 대한 예비적 결과 (Hyperfractionated Radiotherapy and Concurrent Chemotherapy for Stage III Unresectable Non Small Cell Lung Cancer : Preliminary Report for Response and Toxicity)

  • 최은경;김종훈;장혜술;김상위;서철원;이규형;이정신;김상희;고윤석;김우성;김동순;김원동;송군식
    • Radiation Oncology Journal
    • /
    • 제13권2호
    • /
    • pp.157-162
    • /
    • 1995
  • 목적 : 절제 불가능한 제 3기 비소세포성 폐암에서 다분할 방사선 치료와 MVP 복합 항암요법의 동시 치료에 의한 종양관해율, 급성부작용, 생존기간에 미치는 효과를 알아보기 위하여 1993년 8월부터 전향성 연구(Prospective study)를 시작하였다. 방법: 본 연구는 제 III기의 비소세포성 폐암중 절제가 불가능한 환자를 대상으로 하여 다분할 방사선치료(120 cGy/fx, BID)를 6,480 cGy 시행하며 동시에 방사선치료 제1일과 28일에 2회의 MVP (Mitomycin C $6mg/m^2,$ Vinblastine $6mg/m^2,$ Cisplatin $60mg/m^2$) 복합 항암 요법을 시행하였다. 1994년 11월까지 등록된 62명의 환자에 대한 분석을 시행하였다. 병기는 IIIa 환자가 6명이고 나머지 56명은 IIIb 환자였으며 이중 흉막액이 있었던 환자는 11명, 쇄골상 임파선 전이가 있었던 환자는 10명으로 대부분의 환자가 IIIb 중에서도 진행된 환자였다. 조직학적 유형은 편평 상피암이 41명으로 $66\%$ 선암도 11명으로 $18\%$를 차지하였다. 결과: 52명의 환자중 끝까지 치료를 마친 환자는 48명으로 이 study의 compliance는 $77\%$이었다. 48명의 환자중 2명은 치료중 치료와 관계된 백혈구 감소로 인한 폐렴으로 사망하였다. 치료의 효과를 판정할 수 있었던 46명의 환자중 완전 관해(CR)는 10명으로 $22\%$의 높은 완전 관해율을 보였다. 부분 관해(PR)는 24명 $(52\%)$ 으로 다분할 방사선 치료와 동시 병행 MVP 항암요법에 의한 부분관해 이상의 관해율은 $74\%$ 이었다. 급성부작용 판정이 가능했던 46명중 가장 빈도가 높은 금성 부작용은 백혈구 감소로 1차 항암요법후 10명이 Grade 3, 4명이 Grade 4의 백혈구 감소를 보였으며 2차 항암요법에는 11명이 Grade 3, 9명이 Grade 4의 백혈구 감소를 보여 치료기간이 3일에서 5일 정도 지연되는 결과를 나타냈고 이중 2명은 폐렴으로 인한 패혈증으로 사망하였다. 치료중 체중감소를 보인 환자는 26명 $(54\%)$ 이었으며 이중 9명에서는 치료전에 비해 $10\%$ 이상의 체중감소를 보였다. 치료 1개월후 찍은 CT상 6명에서는 Grade 1의 방사선 폐렴이 관찰되었고 3명에서는 Grade 2로 Steroid 치료후 호전되었다. 결론: 이상의 결과 다분할 방사선 치료와 MVP 항암요법의 동시 치료가 이전의 항암요법후 다분할 방사선 치료하는 Sequential 방법에 비하여 높은 관해율을 보이고 특히 $22\%$의 높은 완전 관해율이 관찰되어 이 연구를 계속 진행함으로써 더 좋은 결과를 얻을 것으로 생각되며 급성 부작용에 대하여는 입원을 통한 Nutrition support와 G-CSF 등을 이용하여 백혈구 감소를 막을 수 있을 것으로 생각된다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF