• 제목/요약/키워드: CT-guided surgery

검색결과 86건 처리시간 0.438초

Clinical problems of computer-guided implant surgery

  • Moon, Seong-Yong;Lee, Kyoung-Rok;Kim, Su-Gwan;Son, Mee-Kyoung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.15.1-15.6
    • /
    • 2016
  • Background: The utilization of a cone-beam computed tomography (CT)-assisted surgical template allows for predictable results because implant placement plans can be performed in the actual surgery. In order to assess the accuracy of the CT-guided surgery, angular errors and shoulder/apex distance errors were evaluated by data fusion from before and after the placement. Methods: Computer-guided implant surgery was performed in five patients with 19 implants. In order to analyze differences of the implant fixture body between preoperative planned implant and postoperative placed implant, angular error and distance errors were evaluated. Results: The mean angular errors between the preoperative planned and postoperative placed implant was $3.84^{\circ}{\pm}1.49^{\circ}$; the mean distance errors between the planned and placed implants were $0.45{\pm}0.48mm$ horizontally and $0.63{\pm}0.51mm$ vertically at the implant neck and $0.70{\pm}0.63mm$ horizontally and $0.64{\pm}0.57mm$ vertically at the implant apex for all 19 implants. Conclusions: It is important to be able to utilize these methods in actual clinical settings by improving the various problems, including the considerations of patient mouth opening limitations, surgical guide preparation, and fixation.

Computer-Assisted Mandibular Reconstruction with Monocortical DCIA Flap; A Case Report

  • Moon, Seong-Yong
    • Journal of International Society for Simulation Surgery
    • /
    • 제2권2호
    • /
    • pp.83-86
    • /
    • 2015
  • Recently, computer-assisted surgery is popular for performing well-planned operations. Computer-aided navigation system is helpful in maxillofacial surgery with real time instrument positioning and clear anatomic identification. Generally, segmental mandibulectomy and reconstruction flap surgery have done by extra-oral approach such as, submandibular approach. This case report describes performing intra-oral segmental mandibulectomy and reconstruction with monocortical deep circumflex iliac artery (DCIA) flap and CT guided implant surgery by using computer-aided surgical guide and navigation for managing ameloblastoma in a 31 years old female patient.

Registration of 3D CT Data to 2D Endoscopic Image using a Gradient Mutual Information based Viewpoint Matching for Image-Guided Medialization Laryngoplasty

  • Yim, Yeny;Wakid, Mike;Kirmizibayrak, Can;Bielamowicz, Steven;Hahn, James
    • Journal of Computing Science and Engineering
    • /
    • 제4권4호
    • /
    • pp.368-387
    • /
    • 2010
  • We propose a novel method for the registration of 3D CT scans to 2D endoscopic images during the image-guided medialization laryngoplasty. This study aims to allow the surgeon to find the precise configuration of the implant and place it into the desired location by employing accurate registration methods of the 3D CT data to intra-operative patient and interactive visualization tools for the registered images. In this study, the proposed registration methods enable the surgeon to compare the outcome of the procedure to the pre-planned shape by matching the vocal folds in the CT rendered images to the endoscopic images. The 3D image fusion provides an interactive and intuitive guidance for surgeon by visualizing a combined and correlated relationship of the multiple imaging modalities. The 3D Magic Lens helps to effectively visualize laryngeal anatomical structures by applying different transparencies and transfer functions to the region of interest. The preliminary results of the study demonstrated that the proposed method can be readily extended for image-guided surgery of real patients.

영상유도 뇌수술 장비의 임상적 적용 : Zeiss SMN System (Clinical Application of Image Guided Surgery : Zeiss SMN System)

  • 이채혁;이호연;황충진
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권1호
    • /
    • pp.72-77
    • /
    • 2000
  • The authors describe the experience with the interactive image-guided Zeiss SMN system, which has been applied to 20 patients with various intracranial lesions during one year. Preoperative radiologic evaluation was CT scan in 6 cases, MRI in 14 cases. In all except one case, average fiducial registration errors were less than 2mm. There was no statistical difference in registration error between CT and MR image. This system considered to be relatively stable with respect to soft and hardware. Also it was useful for the designing of the scalp incision and bone flap and assessing the extent of resection in tumors, especially in gliomas. Moreover, it was helpful to evaluate complex surgical anatomy in skull base surgery.

  • PDF

Comparative Analysis of Surgical Outcomes of C1-2 Fusion Spine Surgery between Intraoperative Computed Tomography Image Based Navigation-Guided Operation and Fluoroscopy-Guided Operation

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Ki, Sung Soon;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권2호
    • /
    • pp.237-247
    • /
    • 2020
  • Objective : Fixation of the C1-2 segment is challenging because of the complex anatomy in the region and the need for a high degree of accuracy to avoid complications. Preoperative 3D-computed tomography (CT) scans can help reduce the risk of complications in the vertebral artery, spinal cord, and nerve roots. However, the patient may be susceptible to injury if the patient's anatomy does not match the preoperative CT scans. The intraoperative 3D image-based navigation systems have reduced complications in instrument-assisted techniques due to greater accuracy. This study aimed to compare the radiologic outcomes of C1-2 fusion surgery between intraoperative CT image-guided operation and fluoroscopy-guided operation. Methods : We retrospectively reviewed the radiologic images of 34 patients who underwent C1-2 fusion spine surgery from January 2009 to November 2018 at our hospital. We assessed 17 cases each of degenerative cervical disease and trauma in a study population of 18 males and 16 females. The mean age was 54.8 years. A total of 139 screws were used and the surgical procedures included 68 screws in the C1 lateral mass, 58 screws in C2 pedicle, nine screws in C2 lamina and C2 pars screws, four lateral mass screws in sub-axial level. Of the 34 patients, 19 patients underwent screw insertion using intraoperative mobile CT. Other patients underwent atlantoaxial fusion with a standard fluoroscopy-guided device. Results : A total of 139 screws were correctly positioned. We analyzed the positions of 135 screws except for the four screws that performed the lateral mass screws in C3 vertebra. Minor screw penetration was observed in seven cases (5.2%), and major pedicle screw penetration was observed in three cases (2.2%). In one case, the malposition of a C2 pedicle screw was confirmed, which was subsequently corrected. There were no complications regarding vertebral artery injury or onset of new neurologic deficits. The screw malposition rate was lower (5.3%) in patients who underwent intraoperative CT-based navigation than that for fluoroscopy-guided cases (10.2%). And we confirmed that the operation time can be significantly reduced by surgery using intraoperative O-arm device. Conclusion : Spinal navigation using intraoperative cone-beam CT scans is reliable for posterior fixation in unstable C1-2 pathologies and can be reduced the operative time.

임플란트 가이드 수술시 고려사항 (Consideration of computer-guided implant surgery)

  • 김현동
    • 대한심미치과학회지
    • /
    • 제28권1호
    • /
    • pp.4-17
    • /
    • 2019
  • 우리나라 치과의 CBCT 보급률은 세계적으로 높은 편으로, 최근 1만대 보급을 돌파하고 있는 것으로 파악된다. 또한 최근 각 치과 제조업체마다 DLP방식의 In-House방식의 3D 프린터 보급률 또한 가파르게 상승하고 있다. 이에 맞춰 최근 개원가에서 CBCT와 구강 스캔 정보를 이용한 컴퓨터 가이드 임플란트 수술의 활용도가 증가하고 있는 상황이다. 현재 컴퓨터 가이드를 이용한 임플란트 수술 방법에 대해 문헌상 고찰을 통해 리뷰해보고, 또한 정확성 및 신뢰성이 보장되는 가이드 수술을 위한 고려사항에 대해 정리해보고자 한다.

마그네틱 센서를 이용한 영상유도 뇌정위 시스템 개발 (The development of Frameless Image-Guided Surgery system based on magnetic field digitizers)

  • 우지환;장동표;김영수;김선일
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.269-270
    • /
    • 1998
  • Image-guided surgery (IGS) system has become well known in the field of neurosurgery and spine surgery. A patient's anatomy is first registered to preoperatively acquired CT/ MRI data using the point matching algorithm. A magnetic field digitizer was used to measure the physical space data and the system was based on Workstation of Unix system. To evaluate the spatial accuracy of interactive IGS system, the phantom consisting of rods varied height and known location was used. The RMS error value between CT/MR images and real location was 3-4mm. For the more convenience of the surgery, we provide various image display modules.

  • PDF

초음파 유도하 침 생검을 이용한 연부조직 종양의 진단에 있어 양전자방출 컴퓨터 단층촬영술의 유용성 (Availability of Positron Emission Tomography-Computed Tomography for the Diagnosis of the Soft Tissue Tumor through Ultrasound-Guided Biopsy)

  • 전세빈;김정일;이인숙;송유선;최경운
    • 대한정형외과학회지
    • /
    • 제56권5호
    • /
    • pp.398-403
    • /
    • 2021
  • 목적: 연부조직 종양의 진단을 위해서는 생검이 필요하지만, 육종 등 이질성을 가진 종양들의 특징상 정확한 부위의 채취가 어려워 수술적 개방 생검으로도 진단이 어려운 경우가 많다. 이 경우 초음파 유도하 침생검이 진단율을 올릴 수 있는 방법으로 사용되고 있다. 본 연구는 자기공명 관류영상(magnetic resonance perfusion)에서 발견된 연부조직 종양을 진단하는 데 있어 초음파 유도하 침 생검의 정확도를 평가하고, 양전자방출 컴퓨터 단층촬영술(positron emission tomography-computed tomography, PET-CT)의 유용성에 대해 알고자 하였다. 대상 및 방법: 2014년 1월부터 2018년 12월까지 자기공명 관류영상에서 발견된 연부조직의 종양에 대해 초음파 유도하 침 생검을 시행한 총 152예의 환자들 중 최종 진단을 얻어 초음파 유도하 침 생검의 결과와 비교할 수 있었던 86예에 대해 그 정확도를 후향적으로 평가하였다. 총 86예의 환자를 자기공명 관류영상만을 시행한 50예와 자기공명 관류영상과 PET-CT를 함께 시행한 36예로 나누어 그 정확도를 비교, 분석하여 PET-CT가 초음파 유도하 침 생검의 정확도를 향상시킬 수 있는지 알고자 하였다. 결과: 총 86예의 환자들 중 자기공명 관류영상만을 시행한 50예 중에서는 34예에서 최종 진단과 초음파 유도하 침 생검의 결과가 일치하였으며, 자기공명 관류영상과 PET-CT를 함께 시행한 36예 중에서는 32예에서 최종 진단과 초음파 유도하 침 생검의 결과가 일치하여 초음파 유도하 침 생검의 정확도에 있어 유의한 차이를 보였다. 이 중 연부 조직 육종만 따로 분류한다면 자기공명 관류영상만을 시행한 12예 중에서 6예에서 최종 진단과 초음파 유도하 침 생검의 결과가 일치하였고 자기공명 관류영상과 PET-CT를 함께 시행한 18예 중에서는 17예에서 최종 진단과 초음파 유도하 침 생검의 결과가 일치하여 마찬가지로 초음파 유도하 침 생검의 정확도에 있어 유의한 차이를 보였다. 결론: 연부조직 종양을 진단함에 있어 초음파 유도하 침 생검은 정확도가 높은 유용한 검사로 알려져 있지만 육종의 경우 이질성이 있어 자기공명 관류영상만으로는 정확한 생검 부위를 설정하는 데 어려움이 있다. PET-CT 영상은 이러한 연부조직 종양에서 침 생검 부위를 특정하고 정확도를 유의하게 향상시킬 수 있을 것으로 생각된다.

단일구조 수복용 지르코니아와 Dental CAD/CAM System을 이용한 전악 임플란트 고정성 보철 수복 증례 (Full mouth rehabilitation of a patient using monolithic zirconia and dental CAD/CAM system: a case report)

  • 이상훈;윤형인;여인성;한중석;김성훈
    • 구강회복응용과학지
    • /
    • 제34권3호
    • /
    • pp.196-207
    • /
    • 2018
  • 임플란트의 장기적인 안정을 위해서는 이상적인 위치와 각도로 임플란트를 식립하는 것이 중요하며, 이를 위해서는 정확한 계획에 따른 정확한 수술과 보철이 중요하다. 본 증례에서는 치조골 흡수가 심하게 진행된 환자에서 CT data 및 진단왁스업을 스캔한 data를 이용하여 CT guided surgery를 시행하고, 단일구조 수복용 지르코니아와 CAD/CAM technique을 이용하여 전악 임플란트 고정성 보철로 수복하여 기능 및 심미적으로 만족할만한 결과를 얻었기에 이를 보고하고자 한다.

폐실질 내에 위치한 소결질 및 간유리 병변에서 흉부컴퓨터단층촬영 유도하에 Hook Wire를 이용한 위치 선정 후 시행한 흉강경 폐절제술의 유용성 (Computed Tomography-guided Localization with a Hook-wire Followed by Video-assisted Thoracic Surgery for Small Intrapulmonary and Ground Glass Opacity Lesions)

  • 강필제;김용희;박승일;김동관;송재우;도경현
    • Journal of Chest Surgery
    • /
    • 제42권5호
    • /
    • pp.624-629
    • /
    • 2009
  • 배경: 패실질 내에 위치한 소결절 및 간유리 병변은 깊이나 크기에 따라서 조직학적 진단이 기존의 방법으로는 어려운 경우가 있다. 이에 연구자는 흉부 전산화 단층 촬영 소견에서 흉강경을 통한 육안 확인이 어려울 것으로 예상되거나 경피 세침 흡인생검술이 부적절하였던 폐실질 내에 위치한 소결절 및 간유리 병변에서 수슬 전에 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정(CT-guided localization with hook wire)을 시행한 후 흉강경 폐절제술을 시행하였고, 그 결과를 보고 하고자 한다. 대상 및 방법: 2005년 8월부터 2008년 3월까지 흉부 전산화 단층 촬영 소견에서 폐실질내에 위치한 소결절 및 간유리 병변을 보인 18명 환자(남자 13명, 나이 중앙값 56세)를 대상으로 수술 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정을 시행한 후 흉강경 폐절제술을 시행하였다. Hook wire 위치의 정확도, 개흉술 전환 정도, 수술 시간, 수술 후 합병증, 폐병변의 조직학적 진단의 정확성 등을 분석하였다. 결과: 18명의 환자가 18개의 폐실질 내에 위치한 소결절 및 간유리 병변에 대해 흉강경 폐절제술을 받았다. 수술 전 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정은 전례에서 성공적으로 시행되었으나, 흉강경 소견에서 wire가 이탈된 경우가 1예 있었다. 수술 전 CT에서 폐 병변 크기의 중앙값은 8 mm ($3{\sim}15\;mm$)였고, 내장 흉막에서 폐병변까지 깊이의 중앙값은 5.5 mm ($1{\sim}30\;mm$)였다. 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정 후 마취 시작까지 걸린 대기 시간의 중앙값은 34.5분($10{\sim}226$분)이었다. 폐병변에 대한 흉강경 폐절제술의 수술 시간은 43.5분($26{\sim}83$분)이었다. 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정과 관련된 합병증으로 2예에서 기흉이 발생하였으나, 임상적으로 유의한 증상은 없었다. 폐병변의 절제 단면은 모든 경우에서 이상 소견이 없었으며, 조직학적 진단은 원발성 폐암 8예, 전이성 폐암 3예, 비특이적 염증성 소견 3예, 폐내 림프절 2예, 기타 2예 등이었으며 조직학적 진단을 하지 못한 경우는 얼었다. 결론: 폐실질 내에 위치한 소결절 및 간유리 병변의 조직학적 진단을 위하여 시행한 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정 후 시행한 흉강경 폐절제술은, 낮은 합병증 발생률, 짧은 수술 시간 및 정확한 조직학적 진단율을 보였다. 따라서 경피 세침 흡인생검술로 정확한 진단이 어렵거나 흉강경을 통한 육안 확인이 불가능한 폐실질 내의 소결절 및 간유리 병변을 조직학적으로 진단하기 위하여 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용하여 위치를 선정한 후 흉강경 폐절제술을 시행하는 것은 매우 효과적이라고 생각한다.