• 제목/요약/키워드: CT voltage

검색결과 166건 처리시간 0.031초

뇌전산화단층검사에서 방사선량 저감을 위한 최적화 프로토콜 연구 (Optimization of Brain Computed Tomography Protocols to Radiation Dose Reduction)

  • 이재승;권대철
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권3호
    • /
    • pp.116-123
    • /
    • 2018
  • This study is a model experimental study using a phantom to propose an optimized brain CT scan protocol that can reduce the radiation dose of a patient and remain quality of image. We investigate the CT scan parameters of brain CT in clinical medical institutions and to measure the important parameters that determine the quality of CT images. We used 52 multislice spiral CT (SOMATOM Definition AS+, Siemens Healthcare, Germany). The scan parameters were tube voltage (kVp), tube current (mAs), scan time, slice thickness, pitch, and scan field of view (SFOV) directly related to the patient's exposure dose. The CT dose indicators were CTDIvol and DLP. The CT images were obtained while increasing the imaging conditions constantly from the phantom limit value (Q1) to the maximum value (Q4) for AAPM CT performance evaluation. And statistics analyzed with Pearson's correlation coefficients. The result of tube voltage that the increase in tube voltage proportionally increases the variation range of the CT number. And similar results were obtained in the qualitative evaluation of the CT image compared to the tube voltage of 120 kVp, which was applied clinically at 100 kVp. Also, the scan conditions were appropriate in the tube current range of 250 mAs to 350 mAs when the tube voltage was 100 kVp. Therefore, by applying the proposed brain CT scanning parameters can be reduced the radiation dose of the patient while maintaining quality of image.

CT 영상기반 방사선치료계획시스템을 위한 CT수 대 물리적 밀도 변환에 관한 CT 스캐닝 매개변수의 의존성 (The Dependence of CT Scanning Parameters on CT Number to Physical Density Conversion for CT Image Based Radiation Treatment Planning System)

  • 백민규;김종언
    • 한국방사선학회논문지
    • /
    • 제11권6호
    • /
    • pp.501-508
    • /
    • 2017
  • 방사선치료에 사용하는 CT 스캐너에 의해 획득된 CT 및 CBCT 전자밀도팬텀의 CT영상부터 CT수 대 물리적 밀도 변환에 관한 CT 스캐닝 매개변수의 의존성은 실험으로 분석하였다. CT수는 관전류량, 슬라이스 두께, 영상재구성 필터, 시야 그리고 팬텀 용적의 크기에 대해 의존하지 않았다. 그러나 CT수는 관전압과 팬텀 횡단면적 크기에 의존하였다. 결과로서, 물리적 밀도 1이상의 범위에 대하여, 90과 120 kVp 사이의 관전압에서 관측된 최대 CT수 차이는 27%이었고, 그리고 CT 몸통과 머리 전자밀도팬텀 사이에서 관측된 최대 CT수 차이는 15%이었다.

CT 촬영 조건에 따른 PET 영상의 변화 (Change of PET Image According to CT Exposure Conditions)

  • 박재윤;김정훈;이용기
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.473-479
    • /
    • 2019
  • 다양한 촬영 조건의 CT 감쇠 지도가 PET 영상에 영향을 미치는지 알아보기 위하여 다양한 kVp와 mA조건에서 Uniformity phantom 영상의 신호 강도(SI; Signal Intensity)와 표준 섭취율 계수(SUV; Standardized Uptake Value)를 측정하고, CTDI (Computed Tomography Dose Index)를 통해 각 조건에 따른 피폭선량을 측정하였다. 또한 동일한 조건에서 Resolution phantom의 반치폭(FWHM; Full Width at Half Maximum)을 측정하여 CT의 kVp와 mA에 따른 PET 영상의 화질 변화에 대하여 정량적으로 알아보고자 하였다. 연구 결과, CT의 촬영 조건은 PET 영상에는 영향을 주지 않는 것으로 나타났으나, CT의 촬영 조건이 감소하게 되면 방사선 피폭이 감소하게 되지만 영상에 영향을 미치게 되므로 향후 진단이 가능한 CT 화질을 유지하면서 방사선 피폭을 최소화할 수 있는 양전자 방출 단층 촬영(PET/CT; Positron Emission Tomography / Computed Tomography)의 촬영 조건에 대한 연구가 지속적으로 되어야 할 것이다.

CT 모의치료장치에서 발생된 X-선 빔의 유효에너지 계산식 유도 (Derivation of the Effective Energy Calculation Formula of the X-ray Beam Generated by the CT Simulator)

  • 김종언;이상훈
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.869-875
    • /
    • 2021
  • 이 연구의 목적은 CT 모의치료장치에서 발생된 X-선 빔의 유효에너지 계산식을 유도하는데 있다. 90, 120, 140 kVp X-선 빔 하에서, AAPM CT 성능 팬텀의 CT수 교정 삽입부는 CT 모의치료장치로 5번 스캔하였다. 폴리에틸렌, 폴리스틸렌, 물, 나일론, 폴리카보네이트, 그리고 아크릴의 CT수는 각각의 CT 슬라이스 영상에 대하여 측정하였다. 단일 관전압 하에서 측정된 CT수 평균값과 미국표준기술연구소의 자료로부터 계산된 각각의 광자에너지에 대응하는 선감쇠계수들을 선형정합하였다. 얻어진 상관계수들 중 최대값을 갖는 광자에너지를 유효에너지를 결정하였다. 이와 같은 방법으로, 각각의 관전압에서 생성된 X-선 빔의 유효에너지를 결정하였다. 결정된 유효에너지(y)들와 관전압(x)들을 선형정합하여 유효에너지 계산식으로서 y=0.33026x+30.80263을 유도하였다.

두부 CT의 노출 파라메타에 따른 화질과 선량의 변화 (Changes in Image Quality and Dose according to Exposure Parameters of Brain CT)

  • 최석윤;임인철
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.705-711
    • /
    • 2019
  • 현재 최신 장비의 두부 CT검사에서 파라메타의 변화와 선량변화에 대한 연구가 부족하고 특히 노이즈, 균일도 해석 및 선량변화에 대한 연구가 부족하다고 생각된다. 따라서 높은 사양 두부 CT 사용 시 노출 파라메타 중 관전압, 슬라이스 두께, 피치변화에 대해 분석하여 이때 발생하는 현상에 대해서 연구하고자 하였다. 실험을 통해서 균일도는 고관전압과 두꺼운 슬라이스 선택 및 최저 피치를 사용할 때 균일도가 좋음을 알 수 있었다. 모두 조합한 결과 균일도가 가장 조건은 140 kVp, 10 mm, pitch 0.5로 나타났다. 노이즈는 관전압과 슬라이스 두께를 높이면 피치에 관계없이 개선되는 것을 알 수 있었고, 선량은 관전압과 피치의 증가에 따라 선형적으로 증가하는 것으로 나타났다. 따라서 본 연구결과는 고 사양의 두부 CT 사용에서 참고자료가 될 것이다.

CT와 CCVT의 오차를 고려한 거리 계전기의 응동 분석 (Analysis of the response of a distance relay considering the errors of CT and CCVT)

  • 강용철;정태영;최재선;강해권;김광무;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.12-15
    • /
    • 2008
  • A distance relay has been widely used for transmission line protection. The distance relay detects a fault based on the calculated impedance i.e. the ratio of the voltage to the current measured from a current transformer (CT) and a coupling capacitor voltage transformer (CCVT), respectively. When a fault occurs and a CT saturates due to the magnitude of fault current, dc component, primary time constant, and the remanent flux of the iron core, the secondary current of a CT is distorted On the other hand, non-fundamental components generated during a fault can increase the error of a CCVT, particularly when a fault distance is short. The distortion of the current and voltage can cause mal-operation or the operating time delay of a distance relay. This paper describes the response of a distance relay considering the errors of a CT and a CCVT. The results indicate that the severe distortion of a CT and a CCVT have noticeable effect to a distance relay.

  • PDF

보호계전기용 CT의 여자특성 자동측정 시스템 개발 (Development of an Automatic Excitation Characteristics Measurement System of the Protective Relaying CT)

  • 권성원;김문석;김재영;이성하;정재갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.868-869
    • /
    • 2008
  • An automatic excitation characteristics measurement system for the protective relaying current transformer(CT) with accuracy of about 1 % has been developed. The system can be used up to 2 kV and 10 A at power frequency. The developed system can calculate the voltage and current at knee points of $30^{\circ}$ and $45^{\circ}$ tangents in accordance with IEEE standard by the interpolation in log scale. The excitation curve of the CT is plotted in auto-scale simultaneously with measuring rms voltage and current at the secondary of the CT.

  • PDF

반복적인 복부 컴퓨터단층촬영 시행 시 환자선량 감소를 위한 관전압 변화 적용의 유용성 (Usefulness of Application of Tube Voltage Changes to Reduce Patient Dose during Abdominal CT Follow up)

  • 윤준;김현주
    • 한국방사선학회논문지
    • /
    • 제15권3호
    • /
    • pp.293-299
    • /
    • 2021
  • CT 장치를 이용하여 주기적인 검사를 시행하는 환자의 불가항력적 방사선 피폭을 줄이기 위해 다양한 스캔 파라미터 중 X선의 투과력과 밀접한 관전압의 변화를 통해 환자 선량을 감소시킬 수 있는 스캔 방법을 알아보았다. 실험결과 일반적으로 임상에서 많이 적용하는 120 kVp 대신 100 kVp를 적용하여 스캔 시 CTDI가 약 41 % 감소하였다. 또한 화질 변화정도는 CT value는 1046.1±3.7 HU, Pixel value는 71.4±7.9로 측정되었으며 통계분석결과 큰 차이가 없는 것으로 분석되었다(0.05

자속-자화 전류 곡선과 전압-철손 전류 곡선을 이용한 측정용 철심 변류기의 보상 알고리즘 개발 (Development of a Compensating Algorithm for an Iron-cored Measurement CT using Flux-magnetizing Current Curves and Voltage-core Loss Current Curves)

  • 강용철;정태영;강해권;이병은;김용균
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1849-1854
    • /
    • 2009
  • This paper describes the design, evaluation and implementation of a compensating algorithm for an iron-cored measurement current transformer (CT) that removes the effects of the hysteresis characteristics of the iron-core. The exciting current resulting from the hysteresis characteristics of the core causes an error of the CT. The proposed algorithm decomposes the exciting current into the core loss current and the magnetizing current and each of them is estimated. The core loss current is calculated from the secondary voltage and the voltage-core loss current curve. The core flux linkage is calculated and then inserted into the flux-magnetizing current curve to estimate the magnetizing current. The exciting current at every sampling interval is obtained by summing the core loss and magnetizing currents and then added to the measured current to obtain the correct secondary current. The voltage-core loss current curve and flux-magnetizing current curves, which are different from the conventional curves, are derived in this paper. The performance of the proposed algorithm is validated under various conditions using EMTP generated data. The experimental test results of an iron-core type electronic CT, which consists of the iron-core and the compensation board, are also included. The results indicate that the proposed algorithm can improve the accuracy of the measurement CT significantly, and thus reduce the size and the cost of the CT.

2차 전압-철손 전류 곡선과 자속-자화 전류 곡선을 고려한 측정용 변류기 2차 전류 보상 알고리즘 (Compensating algorithm for the secondary current of a measurement type CT considering the secondary voltage-core loss current curve and the flux linkage-magnetizing current curve)

  • 강용철;정태영;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.65-66
    • /
    • 2008
  • This paper proposes a compensating algorithm for the secondary current of the measurement current transformer (CT) that removes the effects of the hysteresis characteristics of the iron-core. The exciting current resulting from the hysteresis characteristics of the core causes an error between the primary current and the secondary current of the CT. The proposed algorithm decomposes the exciting current into the magnetizing current and the core loss current and each of them is estimated. The core loss current is calculated from the secondary voltage and the secondary voltage-core loss current curve. The core flux linkage is calculated and then inserted into the flux-current curve to estimate the magnetizing current. The exciting current at every sampling interval is obtained by summing the core-loss and magnetizing currents and then added to the measured current to compensate the secondary current. The performance of the proposed algorithm is validated under various conditions using EMTP generated data. The test results of the real CT were also included. The results indicate that the proposed algorithm can improve the accuracy of the measurement CT significantly, and thus reduce the size and the cost of the CT.

  • PDF