• 제목/요약/키워드: CT simulation

검색결과 367건 처리시간 0.075초

열연 강판의 잔류 응력 해석 (Residual Stress Analysis of Hot Rolled Strip)

  • 구진모;김홍준;이재권;황상무
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 춘계학술대회논문집
    • /
    • pp.172-175
    • /
    • 2003
  • Run-Out-Table is the region between EDT and CT. Hot killed strip is cooled by air and water in ROT. In this procedure, phase transformation and shape deformation occur due to temperature drop. Because of un-ideal cooling condition, deformation of strip and non-uniform phase distribution come into existence. This phenomenon affects the strip property and lead th the existence of residual stress. And it exerts effects on the Coiling process, Coil Cooling process, and Un-coiling process. Through these process, the residual stresses of strip are more larger and unbalance of these stresses become more severe. Finite element (FE) based models for the analysises of non-steady state heat transfer and elastoplastic deformation are described in this investigation. The analysises of thermodynamics and phase transformation kinetics are suggested also. Using the ROT simulation result coiling process and coil cooling process simulations are carried out.

  • PDF

상호정보 최적화를 통한 다중 모달리티 영상정합 (Multimodality Image Registration by Optimization of Mutual Information)

  • 홍헬렌;김명희
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 2000년도 추계학술대회 논문집
    • /
    • pp.180-185
    • /
    • 2000
  • 방사선 치료계획이나 사전수술계획 등에 컴퓨터 사용이 늘어남에 따라 의료영상별 특성에 따른 복합적 처리를 필요로 한다. 본 논문에서는 다중 모달리티 영상으로부터 의미 있는 정보를 제공하기 위하여 상호정보 최적화를 통한 영상정합 방법을 제안한다. 본 방법은 두 영상에서 대응되는 위치의 명암도간 통계적 의존관계와 정보중복성을 계산하는 상호정보(mutual information)를 통해 영상간 변형관계를 추정함으로써 영상을 정합한다. 실험결과로는 뇌 자기공명영상(MRI)과 컴퓨터단층촬영영상(CT)의 상호정보를 최적화하여 정합 결과를 제시한다. 본 방법은 기존 정합방법에서 사용하는 영상분할이나 특징점 추출 등의 전처리 과정 없이 영상 자체 정보를 기반으로 계산함으로써 정합의 정확도를 높일 수 있다.

  • PDF

3D Overhead Modeling Using Depth Sensor

  • Song, Eungyeol;Lee, Sangyoun
    • Journal of International Society for Simulation Surgery
    • /
    • 제1권2호
    • /
    • pp.83-86
    • /
    • 2014
  • Purpose This paper was purposed to suggest the method to produce the supportive helmet (head correction) for the infants who are suffering from plagiocephaly and to evaluate the level of transformation through 3D model. Method Either of CT or X-ray restored images has been used in making the supportive helmet (Head correction) in general, but these methods of measuring have problems in cost and safety. 3D surface measurement technology was suggested to solve such matters. Results It was to design the transformed model of the head within 0.7cm in average by scanning the surface of head and performing 3D restoration with marching cube and the changing rate of the head was compared in numerical data with 3D model. Conclusion The suggested methods displayed the better performance than the conventional method in respect of the speed and cost.

정상 I급 교합과 Full-CUSP II급 교합의 두개골 구조거동 비교 해석연구 (Comparative Study on Structural Behaviors of Skull in Occlusions for Class I and Full-CUSP Class II)

  • 이여경;박재용;김희선
    • 한국전산구조공학회논문집
    • /
    • 제29권4호
    • /
    • pp.309-315
    • /
    • 2016
  • 최근 치의학 분야에서도 인체에 대한 구조적이고 역학적인 이해를 위하여 유한요소해석 기법이 널리 사용되고 있다. 따라서 본 연구에서는 CT 이미지를 기반으로 하는 유한요소모델링 기법을 제안하고, 실험결과와 비교하여 검증하였다. 또한 제안된 해석기법을 통해 교합 시뮬레이션을 구현하여 정상 I급 교합과 Full-CUSP II급 교합상태의 두개골 모델에 대하여 기하비선형구조해석을 수행하였다. 그 결과, 하악골이 같은 거리만큼 이동할 때 사람의 실제 교합력 범위에서는 두 모델의 교합력에 큰 차이가 없는 것으로 나타났다. 그러나 응력분포를 비교했을 때 정상 I급 교합모델은 치아 및 치조골 전반에 응력이 균등하게 발생하는 반면, Full-CUSP II급 교합모델의 경우 일부 구역에 응력집중 현상이 나타났다. 이는 치아의 부재 및 재배열로 인하여 교합면이 달라지면서 생긴 결과라고 분석된다.

Evaluation of Masseter Muscle Volume after Contouring of Prominent Mandible Angle by Measurement of CT Scan Image

  • Kim, Yong Oock;Choi, Jong Woo
    • Journal of International Society for Simulation Surgery
    • /
    • 제1권2호
    • /
    • pp.71-74
    • /
    • 2014
  • Purpose The prominent mandible angle, otherwise known as "square face", has been recognized as an aesthetic problem that needs correction by many in the Asian community. Many surgeons considered that mandible angle ostectomy alone, brings about hypotrophy of the masseter muscle. However, it was only proven indirectly (by clinical experience and histological animal experiments) and not objectively. In this study, we evaluated the volume of masseter muscle to prove the effect, objectively. Materials and method Computed tomography (CT) images were used to measure the masseter muscle volume of normal female group (n=6), and of female patient group n=8, preoperative and early & late postoperative volumes) presenting the symptom of prominent mandible angle. The data was analyzed statistically by two-sample t-test and paired t-test using SAS (version 8.2). Results In normal female group, volume average was $16,142{\pm}2,829.8mm^3$. In patient group, preoperative volume averaged $24,447{\pm}4,544.5mm^3$ (p<0.0001), early postoperative volume measured average of $31,966{\pm}50,421mm^3$ which is a 30% increase from the preoperative volume (p<0.0001). Late postoperative measurement was $20,202{\pm}4,092.3mm^3$, which is a 20% decrease from the preoperative volume (p<0.0006). Conclusion The bone reduction of prominent mandible angle induce the hypotrophic effect of masseter muscle after long term follow up (5 more months). This result mean that the result of mandible angle contouring surgery can be considered as combined effect of bony angle reduction and subsequent masseter muscle hypotrophy.

Predictive model of fatigue crack detection in thick bridge steel structures with piezoelectric wafer active sensors

  • Gresil, M.;Yu, L.;Shen, Y.;Giurgiutiu, V.
    • Smart Structures and Systems
    • /
    • 제12권2호
    • /
    • pp.97-119
    • /
    • 2013
  • This paper presents numerical and experimental results on the use of guided waves for structural health monitoring (SHM) of crack growth during a fatigue test in a thick steel plate used for civil engineering application. Numerical simulation, analytical modeling, and experimental tests are used to prove that piezoelectric wafer active sensor (PWAS) can perform active SHM using guided wave pitch-catch method and passive SHM using acoustic emission (AE). AE simulation was performed with the multi-physic FEM (MP-FEM) approach. The MP-FEM approach permits that the output variables to be expressed directly in electric terms while the two-ways electromechanical conversion is done internally in the MP-FEM formulation. The AE event was simulated as a pulse of defined duration and amplitude. The electrical signal measured at a PWAS receiver was simulated. Experimental tests were performed with PWAS transducers acting as passive receivers of AE signals. An AE source was simulated using 0.5-mm pencil lead breaks. The PWAS transducers were able to pick up AE signal with good strength. Subsequently, PWAS transducers and traditional AE transducer were applied to a 12.7-mm CT specimen subjected to accelerated fatigue testing. Active sensing in pitch catch mode on the CT specimen was applied between the PWAS transducers pairs. Damage indexes were calculated and correlated with actual crack growth. The paper finishes with conclusions and suggestions for further work.

치과 진료 시뮬레이션을 위한 3차원 치아의 재구성 시스템 (3D Reconstruction System of Teeth for Dental Simulation)

  • 허훈;최원준;채옥삼
    • 정보처리학회논문지B
    • /
    • 제11B권2호
    • /
    • pp.133-140
    • /
    • 2004
  • 최근 치과 분야의 정보화는 환자자료와 진단영상의 취득과 관리 등을 포함하는 통합 정보화시스템으로써 급속히 발전되었다. 이러한 시스템이 성공하기 위해선 의사가 정확하게 질환을 진단하고 치료하도록 양질의 정보를 제공하며 환자들에게 필요한 고가의 치료를 효과적으로 설득할 수 있는 기능이 확보되어야 한다. 이러한 측면에서 치과분야 시뮬레이션이 가능한 3차원 재구성된 치아모델이 필요하다 치과분야의 치아조작은 대부분 개별 치아 단위로 이루어진다. 따라서 3차원 치아 재구성 시스템은 개변치아의 영역분할과 치아에 맞는 재구성기술이 요구된다. 본 논문에서 적응 최적 임계화를 사용한 치아단위 영역분할 방안과 분할된 경계를 사용한 윤곽선 기반방식의 치아 재구성방안을 제안한다. 즉, 연속된 CT영상에서 개별치아 영역을 정확히 분할하기 위해 슬라이스마다 적응적으로 결정된 최적의 임계치를 사용하여 각 치아를 인접한 이웃 치아와 치조골로부터 분리한다. 분할결과는 3차원 재구성되어 개별 치아를 조작하는 사용자의 입력에 따라 3차원 공간상에서 치아의 이동, 발거 동작을 바탕으로 치과 진료의 시뮬레이션을 가능하게 한다.

방사선치료계획을 위한 PET 종양용적 결정 연구: 컴퓨터 모의실험 (Determination of Tumor Volume in PET for the Radiation Treatment Planning: Computer Simulation)

  • 윤석남;조철우;이재성
    • 한국의학물리학회지:의학물리
    • /
    • 제16권4호
    • /
    • pp.183-191
    • /
    • 2005
  • PET 기기의 보급이 급속도로 증가하고 있으며 여러 임상 및 연구 분야에서 그 유용성이 입증되어 널리 이용되고 있다. 이 가운데서도 종양 진단 분야에서 PET의 활용도는 매우 높아 대부분의 PET검사를 종양 검사가 차지하고 있으며 특히 양성과 악성종양의 감별, 종양의 치료효과 판정 및 종양의 재발진단 등에 널리 이용되고 있다. 최근에는 PET과 CT를 결합한 PET-CT의 사용이 증가됨에 따라 방사선치료분야에서 PET의 활용에 대한 관심이 커지고 있다. 방사선치료를 위한 종양의 경계를 결정하기 위하여 해부학적인 영상인 CT를 이용하는 것이 보편적이나 이 경우 실제 암조직에 상관없이 모양만을 기준으로 삼으므로 암조직에 대한 방사선 치료 용량이 많거나 적을 수 있어 적절한 치료가 되지 않을 수 있다. 따라서 PET을 이용한 기능적이고 살아 있는 암조직의 정확한 용적 측정은 적절한 치료 지표를 줄 수 있어 매우 중요한 일이나 상대적으로 낮은 공간해상도에 의해 정확한 경계를 결정하기 어려운 문제가 있다. 이 연구에서는 실제 종양의 용적을 구할 수 있는 영상화소 값의 역치가 변변의 크기, PET 기기의 공간해상도, 병변 대 주변 섭취비에 어떠한 영향을 받는지를 평가하기 위한 컴퓨터 모의실험을 수행하였다.

  • PDF

Geant4 전산모사를 이용한 두개골 팬텀의 물질 두께 변동에 따른 양성자 브래그 피크의 위치 변화 (Change of Proton Bragg Peak by Variation of Material Thickness in Head Phantom using Geant4)

  • 김유미;천권수
    • 한국방사선학회논문지
    • /
    • 제15권4호
    • /
    • pp.401-408
    • /
    • 2021
  • 양성자 치료는 방사선치료 중 하나로 브래그 피크로 알려진 물리적 특성을 활용한 방법이다. 양성자 치료계획 수립 시 주로 전산화단층촬영(CT)의 인체 횡단면 영상이 사용되고 있다. CT는 사용되는 관전압에 따라 HU가 변하게 되며 이는 구조물의 경계, 두께 변화로 이어진다. 본 연구는 Geant4를 이용하여 복합 물질로 구성된 두개골 팬텀에서 두께 변화에 따른 뇌 영역의 브래그 곡선의 변화를 살펴보았다. 먼저, 단일 물질로 구성된 팬텀에서 매질의 종류와 양성자의 입사에너지에 따른 브래그 곡선을 측정하여 Geant4 계산결과의 신뢰성을 확보하였다. 두개골 팬텀의 각 두께를 변동하였을 때 뇌 영역에서 발생하는 피크의 위치변화를 측정하였다. 연부조직의 두께를 변화하였을 때 피크의 위치 변화는 나타나지 않았으며, 피부의 두께를 변화하였을 때 피크의 변화는 적었으며, 주로 뼈의 두께를 변화할 때 피크의 위치 변화가 나타났다. 또한 뼈를 단독으로 변화하였을 때와 뼈를 다른 조직과 함께 변화하였을 때 피크의 위치 변화량은 동일하였다. 뼈의 정확한 두께 측정이 방사선치료계획의 선량-깊이 분포 예측에 주요 인자 중 하나임을 확인하였다.

조영제를 사용한 복부CT영상에서 명암값 비율을 이용한 간의 자동 추출 (Automatic Liver Segmentation by using Gray Value Portion in Enhanced Abdominal CT Image)

  • 유승화;조준식;노승무;신경숙;박종원
    • 대한전자공학회논문지SP
    • /
    • 제38권2호
    • /
    • pp.179-190
    • /
    • 2001
  • 제안된 연구에서는 조영제를 사용한 복부 CT 영상에 대한 특성을 분석함으로써 간에 대한 자동추출을 시행하였다. 영상에 나타난 명암값을 지형적 고도정보로 해석하는 침수실험에 근거하여 영역을 분리하였고 임계값에 의하여 장기 내부의 국부최대점들을 제거함으로써 장기에 해당하는 부분들을 합병하였다. 임계값은 장기를 구성하는 각 명암값의 비율에 의하여 생성된 메쉬영상으로부터 결정되었고 간과 노이즈 영역의 분리에 사용되었다. 장기의 외곽선추출을 위해서는 장기의 전반적인 형태를 나타내는 템플리트를 생성한 후 이진 영상에서 서브트랙션하는 방법을 사용하였다. 템플리트의 생성과정에서는 처리시간이 긴 기존의 오프닝 방법을 사용하지 않고 8-연결성에 의한 방법을 사용함으로써 처리속도를 단축하였다. 추출된 장기의 면적을 토대로 체적계산을 시행하였고 동물실험을 통하여 임상 실험치를 제시하였다.

  • PDF