A Study on Absorbed Dose in the Breast Tissue using Geant4 simulation for Mammography (유방촬영에서 Geant4 시뮬레이션를 이용한 유방조직내 흡수선량에 관한 연구)

  • Lee, Sang-Ho;Lee, Jong-Seok;Han, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.345-352
    • /
    • 2012
  • As the breast cancer rate is increasing fast in Korean women, people pay more attention to mammography and number of mammography have been increasing dramatically over the last few years. Mammography is the only means to diagnose breast cancer early, but harms caused by radiation exposure shouldn't be overlooked. Therefore, it is important to calculate the radiation dose being absorbed into the breast tissue during the process of mammography for a protective measure against radiation exposure. Because it is impossible to directly measure the radiation dose being absorbed into the human body, statistical calculation methods are commonly used, and most of them are supposed to simulate the interaction between radiation and matter by describing the human body internal structure with anthropomorphic phantoms. However, a simulation using Geant4 Code of Monte Carlo Method, which is well-known as most accurate in calculating the absorbed dose inside the human body, helps calculate exact dose by recreating the anatomical human body structure as it is through the DICOM file of CT. To calculate the absorbed dose in the breast tissue, therefore, this study carried out a simulation using Geant4 Code, and by using the DICOM converted file provided by Geant4, this study changed the human body structure expressed on the CT image data into geometry needed for this simulation. Besides, this study attempted to verify if the dose calculation of Geant4 interlocking with the DICOM file is useful, by comparing the calculated dose provided by this simulation and the measured dose provided by the PTW ion chamber. As a result, under the condition of 28kVp/190mAs, the Difference(%) between the measured dose and the calculated dose was found to be 0.08 %~0.33 %, and at 28 kVp/70 mAs, the Difference(%) of dose was 0.01 %~0.16 %, both of which showed results within 2%, the effective difference range. Therefore, this study found out that calculation of the absorbed dose using Geant4 Simulation is useful in measuring the absorbed dose in the breast tissue for mammography.

Comparative Studies on Absorbed Dose by Geant4-based Simulation Using DICOM File and Gafchromic EBT2 Film (DICOM 파일을 사용한 Geant4 시뮬레이션과 Gafchromic EBT2 필름에 의한 인체 내 흡수선량 비교 연구)

  • Mo, Eun-Hui;Lee, Sang-Ho;Ahn, Sung-Hwan;Kim, Chong-Yeal
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.48-53
    • /
    • 2013
  • Monte Carlo method has been known as the most accurate method for calculating absorbed dose in the human body, and an anthropomorphic phantom has been mainly used as a method of simulating internal organs for using such a calculation method. However, various efforts are made to extract data on several internal organs in the human body directly from CT DICOM files in recent Monte Carlo calculation using Geant4 code and to use by converting them into the geometry necessary for simulation. Such a function makes it possible to calculate the internal absorbed dose accurately while duplicating the actual human anatomical structure. Thus, this study calculated the absorbed dose in the human body by using Geant4 associating with DICOM files, and aimed to confirm the usefulness by compare the result with the measured dose using a Gafchromic EBT2 film. This study compared the dose calculated using simulation and the measured dose in beam central axis using the EBT2 film. The results showed that the range of difference was an average of 3.75% except for a build-up region, in which the dose rapidly changed from skin surface to the depth of maximum dose. In addition, this study made it easy to confirm the target absorbed dose by internal organ and organ through the output of the calculated value of dose by CT slice and the dose value of each voxel in each slice. Thus, the method that outputs dose value by slice and voxel through the use of CT DICOM, which is actual image data of human body, instead of the anthropomorphic phantom enables accurate dose calculations of various regions. Therefore, it is considered that it will be useful for dose calculation of radiotherapy planning system in the future. Moreover, it is applicable for currently-used several energy ranges in current use, so it is considered that it will be effectively used in order to check the radiation absorbed dose in the human body.

Comparison Radiation Dose of Z-Axis Automatic Tube Current Modulation Technique with Fixed Tube Current Multi-Detector Row CT Scanning of Lower Extremity Venography (하지 정맥조영술 MDCT에서 고정 관전류 기법과 Z-축 자동 관전류 변동 제어에 의한 선량 비교)

  • Yoo, Beong-Gyu;Lee, Jong-Seok;Jang, Keun-Jo;Jeon, Sang-Hwan;Kim, Yong-Soo;Kweon, Dae-Cheol
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.123-133
    • /
    • 2007
  • Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of multi-detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, $70{\sim}450\;mA$). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, 2-axis modulation resulted in reduction of CTDIvol (range, $-6.5%{\sim}-35.6%$) and DLP (range, $-0.2%{\sim}-20.2%$). Compared with manually selected fixed tube current, 2-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography.

Simulation of Energy Absorption Distribution using of Lead Shielding in the PET/CT (PET/CT 검사에서 납 차폐체 사용에 따른 에너지 흡수 분포에 관한 모의실험)

  • Jang, Dong-Gun;Kim, Changsoo;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.459-465
    • /
    • 2015
  • Energy absorption distribution according to lead shielding for 511 keV ${\gamma}$ ray was evaluated using a Monte Carlo simulation in PET/CT. Experimental method was performed about the depth of skin surface(0.07), lens(3) and the depth(10) was conducted by using ICRU Slab phantom. Difference of energy absorption distribution according to lead thickness and effect of air gap according to distance of lead and phantom. As a result, study showed that using a lead shielding makes high energy distribution by backscatter electron. As a distance between lead and phantom increased, energy absorption distribution gradually decreased. 9 cm or more air gap should exist to prevent effect of backscatter electron which reaches skin surface, when 0.25 mmPb shielding is used. Also 1 cm or more air gap was needed to prevent the effect in 0.5 mmPb. If air gap was not concerned, 0.75 mm or more lead thickness was necessary to prevent effect of backscatter electron.

Hip Range of Motion Estimation using CT-derived 3D Models (CT기반 3차원 모델을 이용한 고관절 운동범위 예측)

  • Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.115-122
    • /
    • 2018
  • The success of the total hip arthroplasty is revealed as initial stability, range of motion, and long term pain, etc. Depending upon choice of implantation options such as femoral neck offset, diameter of the femoral head, the lateral opening tilt. Especially the impingement between femoral head component and acetabular cup limits the range of motion of the hip. In this sense, estimation or evaluation of the range of motion before and after the total hip arthroplasty is important. This study provides the details of a computer simulation technique for the hip range of motion of intact hip as well as arthroplasty. The suggested method defines the hip rotation center and rotation axes for flexion and abduction, respectively. The simulation uses CT-based reconstructed 3D models and an STL treating software. The abduction angle of the hip is defined as the superolateral rotation angle from sagittal plane. The flexion angle of the hip is defined as the superoanterior angle from the coronal plane. The maximum abduction angle is found as the maximum rotation angle by which the femoral head can rotate superolaterally about the anterior-posterior axis without impingement. The maximum flexion angle is found as the maximum rotation angle by which the femoral head can rotate superoanteriorly about the medial-lateral axis without impingement. Compared to the normal hip, the total hip replacement hip showed decreased abduction by 60 degrees and decreased flexion by 4 degrees. This measured value implies that the proposed measurement technique can make surgeons find a modification of increase in the femoral neck offset or femoral head, to secure larger range of motion.

Evaluation of Scatter Reduction Effect of the Aft-Multiple-Slit (AMS) System Using MC Simulation (MC 시뮬레이션을 이용한 Aft-Multiple-Silt 시스템의 산란선 제거 효과 평가)

  • Chang, Jin-A;Suh, Tae-Suk;Jang, Doh-Yun;Jang, Hong-Seok;Kim, Si-Yong
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.224-230
    • /
    • 2010
  • Purpose: We designed the aft-multiple-slit (AMS) system to reduce scatter in cone-beam computed tomography (CBCT). As a preliminary study, we performed a Monte Carlo N-Particle Transport Code (MCNP) simulation to verify the effectiveness of this system. Materials and Methods: The MCNPX code was used to build the AMS geometry. An AMS is an equi-angled arc to consider beam divergence. The scatter-reduced projection images were compared with the primary images only and the primary plus scatter radiation images with and without AMS to evaluate the effectiveness of scatter reduction. To obtain the full 2 dimensional (2D) projection image, the whole AMS system was moved to obtain closed septa of the AMS after the first image acquisition. Results: The primary radiation with and without AMS is identical to all the slit widths, but the profiles of the primary plus scattered radiation varied according to the slit widths in the 2D projection image. The average scatter reduction factors were 29%, 15%, 9%, and 8% when the slit widths were 5 mm, 10 mm, 15 mm, and 20 mm, respectively. Conclusion: We have evaluated the scatter reduction effect of the AMS in CBCT imaging using the Monte Carlo (MC) simulations. A preliminary study based on the MCNP simulations showed a mount of scatter reduction with the proposed system.

CdZnTe Detector for Computed Tomography based on Weighting Potential (가중 퍼텐셜에 기초한 CT용 CdZnTe 소자 설계)

  • Lim, Hyunjong;Park, Chansun;Kim, Jungsu;Kim, Jungmin;Choi, Jonghak;Kim, KiHyun
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.35-42
    • /
    • 2016
  • Room-temperature operating CdZnTe(CZT) material is an innovative radiation detector which could reduce the patient dose to one-tenth level of conventional CT (Computed Tomography) and mammography system. The pixel and pixel pitch in the imaging device determine the conversion efficiency of incident X-or gamma-ray and the cross-talk of signal, that is, image quality of detector system. The weighting potential is the virtual potential determined by the position and geometry of electrode. The weighting potential obtained by computer-based simulation in solving Poisson equation with proper boundaries condition. The pixel was optimized by considering the CIE (charge induced efficiency) and the signal cross-talk in CT detector system. The pixel pitch was 1-mm and the detector thickness was 2-mm in the simulation. The optimized pixel size and inter-pixel distance for maximizing the CIE and minimizing the signal cross-talk is about $750{\mu}m$ and $125{\mu}m$, respectively.

Development of Respiratory Signal Analysis Program for Accurate Phase Reassignment in 4D CT Reconstruction (4D CT 영상 재구성 시 정확한 위상 변환을 위한 호흡 신호 분석 프로그램 개발)

  • Park, Hae-Jin;Jung, Won-Gyun;Yoon, Jai-Woong;Song, Ju-Young;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.241-246
    • /
    • 2008
  • Patient's respiration can have an effect on movement of tumor range and peripheral organs. Therefore, the respiratory signal was acquired by relation between external markers and movement of patient's abdomen during radiational therapy in order to minimize the effect of respiration. Based on this technique, many studies of rational therapy to irradiate at particular part of stable respiratory signals have executed and they have been clinically applied. Nevertheless, the phase-based method is preferred to the amplitude-based method for the rational therapy related to respiration. Because stabilization of the respiratory signal are limited. In this study, a in-house respiratory signal analysis program was developed for the phase reassignment and the analysis of the irregular respiratory signals. Various irregular respiratory patterns was obtained from clinical experimental volunteers. After then, the in-house program analyzed the factors affecting to phase assignment which is directly related to irradiated sector. Subsequently, accuracy of phase assignment was improved with removement of irregular signals by self-developed algorithm. This study is considered to be useful for not only image reconstruction and elevation of irradiating accuracy through phase assignment of RPM system but also analysis of respiratory signals. Moreover, development of 4D CT image is planed with phantom researches or clinical experiments based on this program.

  • PDF

Evaluation of the Positional Accuracy of the Delivered Beams from the Target: A Phantom Study (방사선 치료에서 치료 표적과 조사 빔의 일치 정도 평가: 팬텀 연구)

  • Kang, Sei-Kwon;Cho, Byung-Chul;Cheong, Kwang-Ho;Ju, Ra-Hyeong;Kim, Su-Ssan;Kim, Kyoung-Ju;Choi, Sang-Gyu;Bae, Hoon-Sik;Lee, Re-Na;Oh, Do-Hoon
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.192-200
    • /
    • 2006
  • We evaluated the positional accuracy of the delivered beams to the target in a phantom by simulating the whole process of the radiation treatments Including CT scanning, planning and beam exposures with MLCs. For this purpose, a phantom was made to calibrate the alignment between the CT and the attached laser system. A new, convenient method was also devised to align the setup lasers in the treatment room. Film was used for the Identification of the delivered beam and analyzed with a homemade computer program. The positional differences between the target and the beam centers varied with the couch rotations. The accelerator we used showed a maximum discrepancy of 2.0 mm at the table angle of $295^{\circ}$. The same measurements based on the new isocenter from the Winston-Lutz test resulted in the maximum of 1.35 mm for all rotation angles. The evaluation of the differences between the target and the beam centers is useful for the treatment planning.

  • PDF

Comparison of Monitor Units Obtained from Measurements and ADAC Planning System for High Energy Electrons (측정과 ADAC 치료계획 시스템에서 계산된 고에너지 전자선의 Monitor Unit Value 비교)

  • Lee, Re-Na;Choi, Jin-Ho;Suh, Hyun-Suk
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.202-208
    • /
    • 2002
  • The purpose of this study is to evaluate the monitor unit obtained from various methods for the treatment of superficial cancers using electron beams. Thirty-three breast cancer patients who were treated in our institution with 6, 9, and 12 MeV electron beams, were selected for this study. For each patient, irregularly shaped treatment blocks were drawn on simulation film and constructed. Using the irregular blocks, monitor units to deliver 100 cGy to the dose maximum (dmax) were calculated from measurement and three-dimensional radiation treatment planning (3D RTP) system (PINNACLE 6.0, ADAC Laboratories, Milpitas CA) Measurements were made in solid water phantom with plane parallel (PP) chamber (Roos, OTW Germany) at 100 cm source-to surface distances. CT data was used to investigate the effect of heterogeneity. Monitor units were calculated by overriding CT values with 1 g/㎤ and in the presence of heterogeneity. The monitor unit values obtained by the above methods were compared. The dose, obtained from measurement in solid water phantom was higher than that of RTP values for irregularly shaped blocks. The maximum differences between monitor unit calculated in flat water phantom at gantry zero position were 4% for 6 MeV and 2% for 9 and 12 MeV electrons. When CT data was used at a various gantry angle the agreement between the TPS data with and without density correction was within 3% for all energies. These results indicate that there are no significant difference in terms of monitor unit when density is corrected for the treatment of breast cancer patients with electrons.

  • PDF