• Title/Summary/Keyword: CT scanning

Search Result 372, Processing Time 0.03 seconds

Mobile Computed Tomography : Three Year Clinical Experience in Korea

  • Jeon, Jin Sue;Lee, Sang Hyung;Son, Young-Je;Yang, Hee-Jin;Chung, Young Seob;Jung, Hee-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.1
    • /
    • pp.39-42
    • /
    • 2013
  • Objective : Obtaining real-time image is essential for neurosurgeons to minimize invasion of normal brain tissue and to prompt diagnosis of intracranial event. The aim of this study was to report our three-year experience with a mobile computed tomography (mCT) for intraoperative and bedside scanning. Methods : A total of 357 mCT (297 patients) scans from January 2009 to December 2011 in single institution were reviewed. After excluding postoperative routine follow-up, 202 mCT were included for analysis. Their medical records such as diagnosis, clinical application, impact on decision making, times, image quality and radiologic findings were assessed. Results : Two-hundred-two mCT scans were performed in the operation room (n=192, 95%) or intensive care unit (ICU) (n=10, 5%). Regarding intraoperative images, extent of resection of tumor (n=55, 27.2%), degree of hematoma removal (n=42, 20.8%), confirmation of catheter placement (n=91, 45.0%) and monitoring unexpected complications (n=4, 2.0%) were evaluated. A total of 14 additional procedures were introduced after confirmation of residual tumor (n=7, 50%), hematoma (n=2, 14.3%), malpositioned catheter (n=3, 21.4%) and newly developed intracranial events (n=2, 14.3%). Every image was obtained within 15 minutes and image quality was sufficient for interpretation. Conclusion : mCT is feasible for prompt intraoperative and ICU monitoring with enhanced diagnostic certainty, safety and efficiency.

Subcutaneous Injection Contrast Media Extravasation: 3D CT Appearance (전산화단층검사에서 조영제의 피하 정맥 혈관외유출 환자의 3D영상)

  • Kweon Dae Cheol;Kim Tae Hyung;Yang Sung Hwan;Yoo Beong Gyu;Kim Myeong Goo;Park Peom
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.47-51
    • /
    • 2005
  • We report a case of an accidental extravasation of contrast material. A large-volume extravasation occurred in an adult during spiral contrast-enhanced CT. The amount of contrast material extravasated was 47 ml. The patient had a swelling of the dorsum right hand. The extravasation injury site was determined by CT scanning. The extavasation case was examined using five separate display techniques: axial, multi planar reformation (MPR), maximum intensity projection (MIP), volume rendering, and shaded-surfaced display (SSD). This paper introduces extravasation with the CT and the three-dimensional appearance.

  • PDF

Three Cases of Fever Unknown Origin with Lymphoproliferative Features and a Unique Pattern of 18-FDG Uptake on the Fusion PET/CT

  • Yun, Dae-Young;Hong, Young-Hoon;Jung, Yong-Uk;Oh, Myung-Jin;Lee, Choong-Ki
    • Journal of Yeungnam Medical Science
    • /
    • v.25 no.1
    • /
    • pp.64-71
    • /
    • 2008
  • Evaluation of a fever of unknown origin (FUO) is complex. Recently, PET scanning has been approved for screening in FUO evaluation. We treated three cases of FUO associated with increased FDG uptake in the bone marrow of the femur and tibia on the fusion PET/CT; all three had the same pattern of uptake. Bone marrow biopsies revealed mature lymphocyte and histiocyte infiltration and myxoid changes in one case, and cortical bone involvement in another case. The cases were all young females who had fever with neutropenia and relative lymphocytosis that lasted for several weeks and then remitted spontaneously. Even though the results of the studies were not diagnostic, the unique uptake pattern on PET/CT and the histology might be related to the cause of the illness and should be studied further to assess the association with classic FUO.

  • PDF

Extravasation Injury of Contrast Media in the Neck and Thorax During MDCT Scanning with 3D Image Reformation Findings (CT검사에서 조영제의 혈관외유출에 의한 목 및 흉부 손상의 3차원 재구성 영상)

  • Kweon, Dae-Cheol;Jang, Keun-Jo;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.281-287
    • /
    • 2007
  • Contrast media may cause tissue injury by extravasation during intravenous automated injection during CT examination. Here, we present a study in which contrast media extravasation was detected and localized in the neck and thorax by three-dimensional(3D) CT data reformation. The CT studies of the extavasation site were performed using a 3D software program with four different display techniques axial, multi planar reformation(MPR), maximum intensity projection(MIP), and volume rendering displays are currently available for reconstructing MDCT data. 3D image reconstructions provide accurate views of high-resolution imaging. This paper introduces extravasation with the MDCT and 3D reformation findings of contrast media extravasation in neck ant thorax. The followed injection of the external jugular vein into an existing intravenous catheter and a large volume of extravasation was demonstrated on by 3D MDCT.

  • PDF

Quantitative Analysis of Skarn Ore Using 3D Images of X-ray Computed Tomography (3차원 X-ray 단층 화상을 이용한 스카른 광석의 정량분석 연구)

  • Jeong, Mi-Hee;Cho, Sang-Ho;Jeong, Soo-Bok;Kim, Young-Hun;Park, Jai-Koo;Kaneko, Katsuhiko
    • Journal of the Mineralogical Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.211-217
    • /
    • 2010
  • A micro-focus X-ray computed tomography (CT) was employed to determine quantitative phase analysis of skarn Zn-Pb-Cu ore by nondestructive visualization of the internal mineral distribution of a skarn ore. The micro CT images of the ore were calibrated to remove beam hardening artifacts, and compared with its scanning electron microscope (SEM) images to set the threshold of CT number range covering sulfide ore minerals. The volume ratio of sulfide and gangue minerals was calculated 20.5% and 79.5%, respectively. The quantitative 3D X-ray CT could be applied to analyse the distribution of economic minerals and their recovery.

Comparison of Intraperitoneal and Retroperitoneal/Pelvic Contrast Extravasation: The Characteristics and Prognosis of the Each Patient Group with Arterial Embolization according to the Abdominal Computed Tomography Scanning after Blunt Trauma (둔상 후 복부 전산화단층촬영에서 조영제 유출로 동맥색전술을 시행받은 환자의 복강내와 후복막강/골반강내 출혈 비교)

  • Yoon, Ji Young;Kim, Sun Hyu;Ahn, Ryeok;Hwang, Jae Cheol;Hong, Eun Seog
    • Journal of Trauma and Injury
    • /
    • v.22 no.2
    • /
    • pp.199-205
    • /
    • 2009
  • Purpose: This study compared the characteristics of and the prognosis for intraperitoneal and retroperitoneal/pelvic contrast extravasation, which had been confirmed by enhanced abdominal CT scan, after blunt trauma in patients who had undergone angiographic embolization. Methods: From January 2001 to March 2009, data were retrospectively collected regarding patients who had undergone contrast extravasation (CE) on CT scanning and arterial embolization after blunt trauma. The study patient group was divided into the intraperitoneal and the retroperitoneal/pelvic groups according to the area of contrast extravasation. We reviewed the initial demographic data, the location of injury, the solid organ injury, the embolized vessel, and the clinical outcome. Results: The mean age of the study subjects was $40.2{\pm}2.6$ years old, and there were 24 male patients. The intraperitoneal group included 10 patients, and retroperitoneal/pelvic group was comprised of 17 patients. The amount of transfusion from presentation to intervention and during the first 24 hours was greater in the retroperitoneal/pelvic group than in the intraperitoneal group. The intraperitoneal group showed a higher frequency and severity of liver injury than the retroperitoneal/pelvic group. Angiography revealed that the hepatic artery (n=4) was the most frequently embolized vessel in the intraperitoneal group, while the internal iliac artery (n=6), followed by the renal artery (n=4), internal pudendal artery (n=3), and the gluteal artery (n=2), were the most frequently injured vessels in the retroperitoneal/pelvic group. Conclusion: In patients with intra-abdominal contrast extravasation found on CT scanning and arterial embolization after blunt trauma, the need for transfusion was less in the intra-abdominal group than in the retroperitoneal/pelvic group. Liver injury was also more frequent and severe in the intraperitoneal group than in the retroperitoneal/pelvic group.

Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy (토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교)

  • Lee, Byungkoo;Kang, Suman
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.145-149
    • /
    • 2013
  • Helical Tomotherapy is an innovative means of delivering intensity modulated radiation therapy (IMRT) using a device that merges features of a linear accelerator and helical computed tomography (CT) scanner. Hereat, during helical tomotherapy process, megavoltage computed tomography (MVCT) image are usually used for guiding the precise set-up of patient before/after treatment delivery. But which would certainly increase the total dose for patients, this study was to investigate the imaging dose of MVCT using the cylindrical "Cheese" phantom on a tomotherapy machine. A set of cylindrical "Cheese" phantom was adopted for scanning with respectively pitch value (1, 2, 3 mm) with same number slice (10 slice), same length (approximately 9 cm) and phantom set-ups on the couch of tomotherapy system. The average MVCT imaging dose were measured using A1SL ion chamber inserted in the phantom with preset geometry. The MVCT scanning average dose for the cylindrical "Cheese" phantom was 2.24 cGy, 1.02 cGy, 0.81 cGy during respectively pitch value (pitch 1, 2, 3 mm) with same number slice (10 slice), and same length's average dose was 2.47 cGy, 1.28 cGy, 0.88 cGy respectively (pitch 1, 2, 3 mm). Two major parameters, the assigned pitch numbers and scanning length, where the most important impacts to the dose variation. The MVCT dose was inversely proportional to the CT pitch value. The results may provide a reliable guidance for proper planning design of the scanning region, which is valuable to help minimize the extra dose to patient. Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines.

The Effects of a MR Torso Coil on CT Attenuation Correction for PET (PET/CT 검사에 있어서 MR Torso Coil의 CT 감쇄보정에 대한 영향 평가)

  • Lee, Seung Jae;Bahn, Young Kag;Oh, Shin Hyun;Gang, Cheon-Gu;Lim, Han Sang;Kim, Jae Sam;Lee, Chang Ho;Seo, Soo-Hyun;Park, Yong Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.81-86
    • /
    • 2012
  • Purpose : Combined MR/PET scanners that use the MRI for PET AC face the challenge of absent surface coils in MR images and thus cannot directly account for attenuation in the coils. To make up for the weak point of MR attenuation correction, Three Modality System (PET/CT +MR) were used in Severance hospital. The goal of this work was to investigate the effects of MR Torso Coil on CT attenuation correction for PET. Materials and Methods : PET artifacts were evaluated when the MR Torso Coil was present of CTAC data with changing various kV and mA in uniformity water phantom and 1994 NEMA cylinderical phantom. They evaluated and compared the following two scenarios: (1) The uniform cylinder phantom and the MR Torso Coil scanned and reconstructed using CT-AC; (2) 1994 NEMA cylinderical phantom and the MR Torso Coil scanned and reconstructed using CT-AC. Results : Streak artifacts were present in CT images containing the MR Torso Coil due to metal components. These artifacts persisted after the CT images were converted for PET-AC. CT scans tended to over-estimate the linear attenuation coefficient when the kV and mA is increasing of the metal components when using conventional methods for converting from CT number. Conclusion : The presence of MR coils during PET/CT scanning can cause subtle artifacts and potentially important quantification errors. Alternative CT techniques that mitigate artifacts should be used to improve AC accuracy. When possible, removing segments of an MR coil prior to the PET/CT exam is recommended. Further, MR coils could be redesigned to reduce artifacts by rearranging placement of the most attenuating materials.

  • PDF

Analysis of Respiratory Motion Artifacts in PET Imaging Using Respiratory Gated PET Combined with 4D-CT (4D-CT와 결합한 호흡게이트 PET을 이용한 PET영상의 호흡 인공산물 분석)

  • Cho, Byung-Chul;Park, Sung-Ho;Park, Hee-Chul;Bae, Hoon-Sik;Hwang, Hee-Sung;Shin, Hee-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.174-181
    • /
    • 2005
  • Purpose: Reduction of respiratory motion artifacts in PET images was studied using respiratory-gated PET (RGPET) with moving phantom. Especially a method of generating simulated helical CT images from 4D-CT datasets was developed and applied to a respiratory specific RGPET images for more accurate attenuation correction. Materials and Methods: Using a motion phantom with periodicity of 6 seconds and linear motion amplitude of 26 mm, PET/CT (Discovery ST: GEMS) scans with and without respiratory gating were obtained for one syringe and two vials with each volume of 3, 10, and 30 ml respectively. RPM (Real-Time Position Management, Varian) was used for tracking motion during PET/CT scanning. Ten datasets of RGPET and 4D-CT corresponding to every 10% phase intervals were acquired. from the positions, sizes, and uptake values of each subject on the resultant phase specific PET and CT datasets, the correlations between motion artifacts in PET and CT images and the size of motion relative to the size of subject were analyzed. Results: The center positions of three vials in RGPET and 4D-CT agree well with the actual position within the estimated error. However, volumes of subjects in non-gated PET images increase proportional to relative motion size and were overestimated as much as 250% when the motion amplitude was increased two times larger than the size of the subject. On the contrary, the corresponding maximal uptake value was reduced to about 50%. Conclusion: RGPET is demonstrated to remove respiratory motion artifacts in PET imaging, and moreover, more precise image fusion and more accurate attenuation correction is possible by combining with 4D-CT.

Basic principle of cone beam computed tomography (Cone beam형 전산화단층영상의 원리)

  • Choi Yong-Suk;Kim Gyu-Tae;Hwang Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.36 no.3
    • /
    • pp.123-129
    • /
    • 2006
  • The use of computed tomography for dental procedures has increased recently. Cone beam computed tomography (CBCT) systems have been designed for imaging hard tissues of the dentomaxillofacial region. CBCT is capable of providing high resolution in images of high diagnostic quality. This technology allows for 3-dimensional representation of the dentomaxillofacial skeleton with minimal distortion, but at lower equipment cost, simpler image acquisition and lower patient dose. Because this technology produces images with isotropic sub-millimeter spatial resolution, it is ideally suited for dedicated dentomaxillofacial imaging. In this paper, we provide a brief overview of cone beam scanning technology and compare it with the fan beam scanning used in conventional CT and the basic principles of currently available CBCT systems.

  • PDF