• Title/Summary/Keyword: CT image

Search Result 1,655, Processing Time 0.027 seconds

A NEW MEASUREMENT METHOD OF FEMORAL ANTEVERSION BASED ON THREE DIMENSIONAL MODELING (3차원 모델링을 이용한 대퇴 전염각의 측정)

  • Kim, June-S.;Park, Hee-J.;Choi, Kwang-S.;Choi, Kui-W.;Kim, Sun-I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.141-144
    • /
    • 1997
  • Femoral neck anteversion is the angle between the neck and the knee axis projected on a plane perpendicular to the longitudinal axis. Conventional methods that use cross-sectional Computed Tomography(CT) images to estimate femoral anteversion have several problems because of the complex 3D structure of the femur. These are the ambiguity of defining the longitudinal axis, the femoral neck axis and condylar line, and the dependence on patient positioning. Especially the femoral neck axis that is known as a major source of error is hard to determine from a single or multiple 2D transverse images. So we developed a new method for measuring femoral anteversion by 3D modeling method. In this method, femoral head is modeled as a sphere. The center of femoral neck is the mid-point of the 2D reconstructed oblique image in the femoral neck part. Then neck axis is a line connecting foregoing two centers. We model the longitude of femur as a cylinder, and the long axis is defined from the fitted cylinder. The knee axis which is tangent to the back of the femoral condyles is easily determined by table-top method. By the definition of femoral anteversion, the femoral anteversion is easily calculated from this model.

  • PDF

The solid angle estimation of acetabular coverage of the femoral head using 3D method (입체각 측정을 통한 대퇴골두에 대한 관골구 coverage 측정)

  • Choi, K.H.;Kim, M.C.;Lim, C.T.;Kim, S.I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.123-126
    • /
    • 1997
  • We present a method for the estimation of 3D solid angle assessment of the acetabular coverage of the femoral head in 3D space. At first, femoral head and acetabulum is segmented from the original CT scan images. The slice thickness is 1.5mm and the number of slices is usually 30-40 to cover the entire acetabulum. The superior half of the femoral head is modeled as part of a sphere. Thus, the axial cross sections of the upper half of the femoral head are also modeled as circles. A set of points from each outline image of femoral head is fitted recursively into a circle by minimizing root-mean-square (RMS) error. With these fitted circles, a center point of the femoral head model is evaluated. This is a reference point for calculating the solid angle of the acetabular inner surface. Next, the tangent lines connecting from a set of points of the acetabular edge to the center of the fitted sphere are obtained. The lines pass through the unit sphere whose center is the same as that of the femoral head. With the points on the unit sphere, we calculate area and estimate the solid angle. Based on this solid angle, the deformity of the acetabulum is analyzed. In case of normal subject, the solid angle is about 4.3 (rad) and acetabular coverage is 68%.

  • PDF

Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever

  • Park, Ji-Man;Kim, Hyun-Joo;Park, Eun-Jin;Kim, Myung-Rae;Kim, Sun-Jong
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.361-371
    • /
    • 2014
  • PURPOSE. In case of large horizontal discrepancy of alveolar ridge due to severe resorption, cantilevered crown is usually an unavoidable treatment modality. The purpose of this study was to evaluate the clinical criteria for the placement of the aforementioned implant crown. MATERIALS AND METHODS. The mandible model with 2 mm thick cortical bone and cancellous bone was fabricated from CT cross-section image. An external connection type implant was installed and cantilevered crowns with increasing offset of 3, 4, 5, 6, and 7 mm were connected. Vertical load and $30^{\circ}$ oblique load of 300 N was applied and stress around bone and implant component was analyzed. A total of 14 cases were modeled and finite element analysis was performed using COSMOS Works (Solid works Inc, USA). RESULTS. As for the location of the vertical load, the maximum stress generated on the lingual side of the implant became larger according to the increase of offset distance. When the oblique load was applied at $30^{\circ}$, the maximum stress was generated on the buccal side and its magnitude gradually decreased as the distance of the offset load increased to 5 mm. After that point, the magnitude of implant component's stress increased gradually. CONCLUSION. The results of this study suggest that for the patient with atrophied alveolar ridge following the loss of molar teeth, von-Mises stress on implant components was the lowest under the $30^{\circ}$ oblique load at the 5 mm offset point. Further studies for the various crown height and numbers of occusal points are needed to generalize the conclusion of present study.

Xanthogranulomatous Pancreatitis Mimicking a Pancreatic Cancer on CT and MRI: a Case Report and Literature Review

  • Park, Jong Min;Cho, Seung Hyun;Bae, Han-Ik;Seo, An Na;Kim, Hye Jung;Lee, So Mi;Yi, Jae Hyuck;Lim, Jae-Kwang;Cho, Chang Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.3
    • /
    • pp.185-190
    • /
    • 2016
  • Xanthogranulomatous inflammation is a rare benign condition involving various organs. However, its pancreas involvement is very rare. To the best of our knowledge, only 17 cases have been described in the literature. Interestingly, all reported 17 cases due to various causes underwent surgical resection. Here, we present a case of xanthogranulomatous pancreatitis in a 63-year-old man. He presented with epigastric pain and solid mass mimicking ductal adenocarcinoma in the body and tail of pancreas on magnetic resonance imaging. The patient was diagnosed as xanthogranulomatous pancreatitis via endoscopic ultrasound-guided fine needle aspiration. After that, he was followed up and monitored without any surgical treatment. Here, we show imaging findings and serial image changes of xanthogranulomatous pancreatitis for this case.

Correlation between Abdominal Fat Distribution and Abdominal Temperature in Korean Premenopausal Obese Women

  • Song, Eun-Mo;Kim, Eun-Joo;Kim, Koh-Woon;Cho, Jae-Heung;Song, Mi-Yeon
    • The Journal of Korean Medicine
    • /
    • v.34 no.2
    • /
    • pp.1-9
    • /
    • 2013
  • Objectives: Considering that homeothermy is a major component of metabolic rate, body temperature might play a role in the pathophysiology of obesity. This study aimed to determine the relationship between abdominal fat distribution and abdominal temperature in Korean, premenopausal, obese women. Methods: Weight and height were measured in 26 premenopausal, obese women to calculate body mass index (BMI). Obesity was defined as a $BMI{\geq}25kg/m^2$. Waist circumference (WC) was also measured as well as abdominal fat by computed tomography (CT) and abdominal temperature by digital infrared thermographic imaging (DITI). Results: Visceral abdominal fat area was found to have a significant negative correlation with the temperature of Guanyuan (CV4, lower abdomen acupoint). We also found the visceral-subcutaneous fat ratio had a significant negative correlation with the temperature of CV4 and Right Tianshu (RST25, lateral navel acupoint). Only visceral fat and its ratio to subcutaneous fat had a significant correlation with abdominal temperature. Subcutaneous fat area and total fat area were not correlated with abdominal temperature. Conclusions: This study suggests that abdominal visceral fat has a significant negative correlation with abdominal temperature. Further study is needed to uncover the relationship between abdominal fat distribution and temperature regulation in obese individuals and to define the role of body temperature in the pathogenesis of obesity.

The Usability Evaluation Half Beam Radiation Treatment Technique on the Esophageal Cancer (식도암 환자에서의 Half Beam 치료법의 유용성 평가)

  • Park, Hochoon;Kim, Youngjae;Jang, Seongjoo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.287-293
    • /
    • 2015
  • Because of esophageal cancer has the long length of the lesion and also inhomogeneous in depth. So, the radiation dose distribution was inhomogeneous in radiation therapy. To overcomes the dose distribution uniformity using half beam method. Patient's CT image was used radiation treatment planning. We used two planning methods that one is the using normal beam and another is using half beam. Than comparing the two radiotherapy planning using target coverage, dose volume histogram, conformity index, homogeneity index and normal tissues - heart, spinal cord, lung -. In results, Treatment planning using half beam is little more than normal beam in target coverage, dose volume histogram, conformity index, homogeneity index and normal tissues covering. However, If the patient is not correct position patients may arise a side effect. Thus, the using in Half beam involving the geometrically exact under lung cancer is considered to advantage.

The Effect of Anteromedial Tibial Cortex Angle on Change of Posterior Tibial Slope Angle in PTO(Proximal Tibial Osteotomy) using Computer Assisted Surgery(CAS) (Computer Assisted Surgery(CAS)를 이용한 개방형 쐐기 근위경골 절골술에서 전내측 경골피질경사각이 후방경골경사각의 변화에 미치는 영향)

  • Lee, Ho-Sang;Kim, Cheol-Woong;Bae, Ji-Hoon;Wang, Joon-Ho;Park, Jong-Woong;Oh, Dong-Joon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1467-1470
    • /
    • 2008
  • An upper tibial opening wedge osteotomy is an operation to cure a malalignment and a degenerate arthritis. To prevent the postoperative malalignment caused by the upper tibial opening wedge osteotomy, the research to define the relationship between a Hinge Axis Angle and a Posterior Slope Angle is needed. The effect of the relationship between the hinge axis angle and the gap angle on the posterior slope angle is studied. After 3-D Compute Tomography (CT) scanning image is reconstructed, the virtual surgery is performed by the reconstructed 3-D tibia model. It was proved that the relationship between the hinge axis angle and the gap angle were constant and the simple mathematical model could be derived. To verify the suggested mathematical model, it compared with the measured data from the virtual surgery. In conclusion, while the deviation between the data from the virtual surgery and ones of the mathematical model under the gap angle<$10^{\circ}$ was less than 1%.

  • PDF

Web based 3-D Medical Image Visualization System on the PC (웹 기반 3차원 의료모델 시각화 시스템)

  • Kim, Nam-Kug;Lee, Dong-Hyuk;Kim, Jong-Hyo;Kang, Heung-Sik;Min, Byung-Goo;Kim, Young-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.201-205
    • /
    • 1997
  • With the recent advance of Web and its associated technologies, information sharing on distribute computing environments has gained a great amount of attention from many researchers in many application areas, such as medicine, engineering, and business. One basic requirement of distributed medical consultation systems is that geographically dispersed, disparate participants are allowed to exchange information readily with each other. Such software also needs to be supported on a broad range of computer platforms to increase the software's accessibility. In this paper, the development of world-wide-web based medical consultation system or radiology imaging is addressed to provide the platform independence and great accessibility. The system supports sharing of 3-dimensional objects. We use VRML (Virtual Reality Modeling Language), which is the de-facto standard in 3-D modeling on the Web. 3-D objects are reconstructed from CT or MRI volume data using a VRML format, which can be viewed and manipulated easily in Web-browsers with a VRML plug-in. A Marching cubes method is used in the transformation of scanned volume data set to polygonal surfaces of VRML. A decimation algorithm is adopted to reduce the number of meshes in the resulting VRML file. 3-D volume data are often very large-sized, and hence loading the data on PC level computers requires a significant reduction of the size of the data, while minimizing the loss of the original shape information. This is also important to decrease network delays. A prototype system has been implemented (http://netopia.snu.ac.kr/-cyber/). and several sessions of experiments are carried out.

  • PDF

Rotational Characteristics of Target Registration Error for Contour-based Registration in Neuronavigation System: A Phantom Study (뉴로내비게이션 시스템 표면정합에 대한 병변 정합 오차의 회전적 특성 분석: 팬텀 연구)

  • Park, Hyun-Joon;Mun, Joung Hwan;Yoo, Hakje;Shin, Ki-Young;Sim, Taeyong
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.68-74
    • /
    • 2016
  • In this study, we investigated the rotational characteristics which were comprised of directionality and linearity of target registration error (TRE) as a study in advance to enhance the accuracy of contour-based registration in neuronavigation. For the experiment, two rigid head phantoms that have different faces with specially designed target frame fixed inside of the phantoms were used. Three-dimensional coordinates of facial surface point cloud and target point of the phantoms were acquired using computed tomography (CT) and 3D scanner. Iterative closest point (ICP) method was used for registration of two different point cloud and the directionality and linearity of TRE in overall head were calculated by using 3D position of targets after registration. As a result, it was represented that TRE had consistent direction in overall head region and was increased in linear fashion as distance from facial surface, but did not show high linearity. These results indicated that it is possible for decrease TRE by controlling orientation of facial surface point cloud acquired from scanner, and the prediction of TRE from surface registration error can decrease the registration accuracy in lesion. In the further studies, we have to develop the contour-based registration method for improvement of accuracy by considering rotational characteristics of TRE.

Effect of Vibration on Trabecualr Bone of OVX Rats (기계적 자극이 난소 제거한 쥐 해면골에 미치는 영향 분석)

  • Ko C.Y.;Lee T.W.;Woo D.G.;Kim H.S.;Kim C.H.;Lee B.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.183-184
    • /
    • 2006
  • Some researchers proposed positive effects of whole body vibration (WBV) on osteoporotic trabecular bones of animals. In the present study, the correlation between the improvement of morphological characteristics and the effect of WBV was investigated and analyzed in OVX rats. The rats were randomly assigned to 5 groups: control, sham, WBV 17Hz, WBV 30Hz and WBV 45Hz. The WBV groups were exercised on a vibration platform (magnitude : $1mm_{peak-peak}$, frequency : 17Hz, 30Hz and 45Hz, 30 minutes/day for 5 days/week). The 4th lumbar on rats was scanned by In-vivo Micro-CT at the week 0(just before WBV) and the week 8(after WBV). Structural parameters of the 4th lumbar, based on two dimensional (2D) scan image data, were investigated and analyzed. The quantitative decrement rate of trabecular bone on WBV groups with 30Hz and 45Hz were lower than control and sham groups. The results showed the positive effect of WBV on osteoporotic bones of OVX rats.

  • PDF