• 제목/요약/키워드: CT Scans

검색결과 576건 처리시간 0.024초

A comparison of preplan MRI and preplan CT-based prostate volume with intraoperative ultrasound-based prostate volume in real-time permanent brachytherapy

  • Park, Hye-Li;Kim, Ja-Young;Lee, Bo-Mi;Chang, Sei-Kyung;Ko, Seung-Young;Kim, Sung-Jun;Park, Dong-Soo;Shin, Hyun-Soo
    • Radiation Oncology Journal
    • /
    • 제29권3호
    • /
    • pp.199-205
    • /
    • 2011
  • Purpose: The present study compared the difference between intraoperative transrectal ultrasound (iTRUS)-based prostate volume and preplan computed tomography (CT), preplan magnetic resonance imaging (MRI)-based prostate volume to estimate the number of seeds needed for appropriate dose coverage in permanent brachytherapy for prostate cancer. Materials and Methods: Between March 2007 and March 2011, among 112 patients who underwent permanent brachytherapy with $^{125}I$, 60 image scans of 56 patients who underwent preplan CT (pCT) or preplan MRI (pMRI) within 2 months before brachytherapy were retrospectively reviewed. Twenty-four cases among 30 cases with pCT and 26 cases among 30 cases with pMRI received neoadjuvant hormone therapy (NHT). In 34 cases, NHT started after acquisition of preplan image. The median duration of NHT after preplan image acquisition was 17 and 21 days for cases with pCT and pMRI, respectively. The prostate volume calculated by different modalities was compared. And retrospective planning with iTRUS image was performed to estimate the number of $^{125}I$ seed required to obtain recommended dose distribution according to prostate volume. Results: The mean difference in prostate volume was 9.05 mL between the pCT and iTRUS and 6.84 mL between the pMRI and iTRUS. The prostate volume was roughly overestimated by 1.36 times with pCT and by 1.33 times with pMRI. For 34 cases which received NHT after image acquisition, the prostate volume was roughly overestimated by 1.45 times with pCT and by 1.37 times with pMRI. A statistically significant difference was found between preplan image-based volume and iTRUS-based volume (p<0.001). The median number of wasted seeds is approximately 13, when the pCT or pMRI volume was accepted without modification to assess the required number of seeds for brachytherapy. Conclusion: pCT-based volume and pMRI-based volume tended to overestimate prostate volume in comparison to iTRUS-based volume. To reduce wasted seeds and cost of the brachytherapy, we should take the volume discrepancy into account when we estimate the number of $^{125}I$ seeds for permanent brachytherapy.

두개골-선조체 팬텀을 이용한 선량 저감화 방안 연구 (The Study of Radiation Exposure Reduction by Developing Corpus Striatum Phantom)

  • 김정수;박찬록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.595-603
    • /
    • 2017
  • 본 연구는 파킨슨질환의 진행 정도를 평가할 수 있는 선조체를 모사한 brain 팬텀을 직접 제작하여, PET-CT검사 시 최적의 영상의 질을 유지하면서 CT 스캔에 의한 brain 선량 저감을 위한 가능성을 평가하였다. 팬텀의 hot sphere와 background (radi oacti vi ty rati o 3:1)에 $^{18}F$ FP-CIT를 주입하고, 관전압(100, 120 kVp)과 관전류(80, 140, 200 mAs)의 조건을 변화시키며 CT 스캔을 실험하였다(기준조건; 120 kVp, 140 mAs). 각 조건에 따라 예상유효선량을 conversion factor를 적용해 계산하였고, SNR과 CRChot의 영상평가 인자를 설정하여 영상의 질을 평가하였다. 실험결과 CT 촬영 기준조건 이하에서의 예상유효선량은 최소 10%에서 최고 60% 정도 감소하였고, 기준조건 이상에서의 예상유효선량은 40% 증가하였다. 또한 PET 영상의 SNR과 CRChot의 유의한 차이는 없었으므로, 관전압과 관전류의 감소에 따라 brain 선량이 감소함을 확인하였다. 이와 동시에 스캔 조건의 변화에도 불구하고 SNR과 CRChot 측면에서의 영상의 질에는 유의한 변화가 없었다. 이러한 사실은 낮은 선량 조건으로도 기존의 선량 조건으로 획득한 영상의 질 수준을 얻을 수 있었으므로, 추후 brain PET-CT 스캔의 선량감소와 동시에 영상의 질 향상에 관한 연구의 기초자료로 활용이 가능할 것으로 사료된다.

흉부악성종양(胸部惡性腫瘍)의 방사선치료계획(放射線治療計劃)에 있어서 전산화단층촬영(電算花斷層撮影)의 이용(利用)에 관한 연구(硏究) (Radiotherapy Treatment Planning with Computed Tomography in Malignant Tumors of the Chest-Comparison of various techniques)

  • 이주혁;고경환;하성환;한만청
    • Radiation Oncology Journal
    • /
    • 제1권1호
    • /
    • pp.55-60
    • /
    • 1983
  • To evaluate the usefulness of computed tomography (CT) in radiotherapy treatment planning in malignant tumors of thoracic cage, the computer generated dose distributions were compared between plans based on conventional studies and those based on CT scan. 22 cases of thoracic malignancies, 15 lung cancers and 7 esophageal cancers, diagnosed and treated in Department of Therapeutic Radiology of Seoul National University Hospital from September, 1982 to April, 1983, were analyzed. In lung cancers, dose distribution in plans using AP, PA parallel opposing ports with posterior spinal cord block and in plans using box technique both based on conventional studies were compared with dose distribution using AP, PA and two oblique ports based on CT scan. In esophageal cancers, dose distribution in plans based on conventional studies and those based on CT scans, both using 3 port technique were compared. The results are as follows: 1. Parallel opposing field technique were inadequate in all cases of lung cancers, as portion of primary tumor in 13 of 15 cases and portion of mediastinum in all were out of high dose volume. 2. Box technique was inadequate in 5 of 15 lung cancers as portion of primary tumor was not covered and in every case the irradiated normal lung volume was quite large. 3. Plans based on CT scan were superior to those based on conventional studies as tumor was demarcated better with CT and so complete coverage of tumor and preservation of more normal lung volume could be made. 4. In 1 case of lung cancer, tumor localization was nearly impossible with conventional studies, but after CT scan tumor was more clearly defined and localized. 5. In 1 of 7 esophageal cancers, the radiation volume should be increased for marginal coverage after CT scan. 6. Depth dose correction for tissue inhomogeneity is possible with CT, and exact tumor dose can be calculated. As a result radiotherapy treatment planning based on CT scan has a pteat advantage over that based on conventional studies.

  • PDF

Interobserver variation in target volume for salvage radiotherapy in recurrent prostate cancer patients after radical prostatectomy using CT versus combined CT and MRI: a multicenter study (KROG 13-11)

  • Lee, Eonju;Park, Won;Ahn, Sung Hwan;Cho, Jae Ho;Kim, Jin Hee;Cho, Kwan Ho;Choi, Young Min;Kim, Jae-Sung;Kim, Jin Ho;Jang, Hong-Seok;Kim, Young-Seok;Nam, Taek-Keun
    • Radiation Oncology Journal
    • /
    • 제36권1호
    • /
    • pp.11-16
    • /
    • 2018
  • Purpose: To investigate interobserver variation in target volume delineations for prostate cancer salvage radiotherapy using planning computed tomography (CT) versus combined planning CT and magnetic resonance imaging (MRI). Materials and Methods: Ten radiation oncologists independently delineated a target volume on the planning CT scans of five cases with different pathological status after radical prostatectomy. Two weeks later, this was repeated with the addition of planning MRI. The volumes obtained with CT only and combined CT and MRI were compared, and the effect of the addition of planning MRI on interobserver variability was assessed. Results: There were large differences in clinical target volume (CTV) delineated by each observer, regardless of the addition of planning MRI ($9.44-139.27cm^3$ in CT only and $7.77-122.83cm^3$ in CT plus MRI) and no significant differences in the mean and standard deviation of CTV. However, there were decreases in mean volume and standard deviation as a result of using the planning MRI. Conclusion: This study showed substantial interobserver variation in target volume delineation for salvage radiotherapy. The combination of planning MRI with CT tended to decrease the target volume and the variation.

구강 및 구인두 편평상피암종의 림프절 전이에 대한 PET-CT 영상의 유용성 (Utility of FDG PET-CT Scans on Nodal Staging of Squamous Cell Carcinoma in the Oral Cavity and Oropharynx)

  • 주영훈;선동일;박준욱;유이령;김민식
    • 대한두경부종양학회지
    • /
    • 제26권1호
    • /
    • pp.14-18
    • /
    • 2010
  • Objectives : We evaluated the use of FDG PET/CT for the identification of cervical nodal metastases of SCC of the oral cavity and oropharynx with histological correlation. Material and Methods : We reviewed 46 medical records, from January 2004 to July 2007, of patients who underwent FDG PET/CT and CT/MRI for SCC of the oral cavity and oropharynx before surgery. We recorded the lymph node metastases according to the neck level affected and the system used for the imaging-based nodal classification. Results : The FDG PET/CT had a sensitivity of 75.6% and a specificity of 96.7% ; it had a higher sensitivity than the CT/MRI for identification of cervical metastases on the side of the neck(26/28 vs. 20/28, p=0.031) and at each of the cervical levels(34/45 vs. 26/45, p=0.008). There was a significant difference in the $SUV_{max}$ between the benign and malignant cervical lymph nodes($3.31{\pm}3.23$ vs. $4.22{\pm}2.57$, p=0.028). The receiver-operating-characteristic (ROC) curve analysis for differentiating the benign from the malignant cervical lymph nodes, showed that the area under the curve(AUC) of the FDG PET/CT was 0.775. The cut-off value for the $SUV_{max}$ was 2.23 based on the ROC curve. There was a significant correlation between the $SUV_{max}$ and the size of the cervical lymph nodes(Spearman r=0.353, p=0.048). Conclusion : FDG PET/CT images were more accurate than the CT/MRI images. In addition, the $SUV_{max}$ cut-off values were important for evaluating cervical the cervical nodes in the patients with SCC of the oral cavity and oropharynx.

CT 검사 시 관전압과 BMI 변화에 따른 화질 및 피폭평가 (Evaluation of Image Quality and dose with the Change of kVp and BMI in the Liver CT)

  • 김동현;고성진;강세식;김정훈;최석윤;김창수
    • 한국콘텐츠학회논문지
    • /
    • 제13권6호
    • /
    • pp.331-338
    • /
    • 2013
  • 간질환을 주소로 추적검사를 위해 내원한 CT(Computer Tomography, 이하 CT) 검사자를 대상으로 체질량 지수와 관전압 변화에 따른 영상의 화질 및 방사선 피폭선량변화에 대하여 알아보고자 하였다. 2010년 3월부터 2011년 6월까지 부산 P대학병원에 복부 CT 를 검사한 환자 중 체질량지수(Body Mass Index, 이하 BMI)가 25이하인 환자를 대상으로 하였고 대상자는 48명이었다. 영상의 질의 객관적 평가로 신호대 잡음비와 유효선량을 비교하였다. 복부 영상의 화질평가는 영상의학과 의사2명이 한국의료영상품질관리원에서 선정한 임상영상 평가의 기준을 근거로 해 1점에서 20점까지 점수를 매겨 평가하였다. 피폭선량분석에서 CTDIvol값은 관전압이 100kVp일 때 120kVp보다 약44.1%가 감소하였다. 그리고 유효선량은 관전압 100kVp일 때 120kVp보다 약43%가 감소하였다. 영상의 화질 평가는 반복적으로 CT검사를 위해 내원한 총48명의 검사자 영상 중 Good 1명, Excellent 47명으로 평가되었다. 추적검사를 시행하는 환자 중 BMI지수가 25이하인 환자들을 대상으로 저관전압을 적용한 복부 CT검사 시 영상의 질적 저하없이 진단 가치가 있는 영상의 획득과 피폭선량 감소효과를 얻을 수 있다고 사료된다.

고해상도 전산화 단층촬영에서 확인된 골절 유형에 따른 측두골 골절의 진단에서 뇌전산화 단층촬영의 유용성 (Utility of Brain Computed Tomography in Detecting Fractures of the Temporal Bones Correlated with Patterns of Fracture on High-Resolution Computed Tomography)

  • 권봉석;신동혁;최필조;한상국;이정훈;송형곤
    • Journal of Trauma and Injury
    • /
    • 제23권1호
    • /
    • pp.38-42
    • /
    • 2010
  • Purpose: The clinical utility of brain computed tomography (CT) in detecting temporal bone fracture is not well established. We performed this study to determine the utility of brain computed tomography (CT) in detecting fractures of the temporal bones in correlation with fracture patterns. We used high resolution computed tomography (HRCT) as the gold standard for diagnosing temporal bone fracture and its pattern. Methods: From January 2007 to December 2009, patients who underwent both brain CT and HRCT within 10 days of head trauma were investigated. Among them, 58 cases of temporal bone fracture confirmed by HRCT were finally included. Fracture patterns (transverse or non-transverse, otic capsule sparing or otic capsule violating) were determined by HRCT. Brain CT findings in correlation with fracture patterns were analyzed. Results: Among 58 confirmed cases of temporal bone fracture by HRCT, 14 cases (24.1%) were not detected by brain CT. Brain CT showed a significantly lower ability to detect temporal bone fracture with transverse component than without transverse component (p=0.020). Moreover, brain CT showed lower ability to detect otic capsule violating pattern than otic capsule sparing pattern (p=0.015). Among the 14 cases of temporal bone fracture that were not detected by brain CT, 4 cases lacked any objective physical findings (facial palsy, hemotympanum, external auditory canal bleeding) suggesting fractures of the temporal bones. Conclusion: Brain CT showed poor ability to detect temporal bone fracture with transverse component and otic capsule violating pattern, which is associated with a poorer clinical outcome than otic capsule sparing pattern. Routine use of HRCT to identify temporal bone fracture is warranted, even in cases without evidence of temporal bone fracture on brain CT scans or any objective physical findings suggestive of temporal bone fracture.

$^{18}F$-FDG PET/CT 검사에서 신장 방사능의 효과적인 배설 방법에 관한 연구 (Evaluation of the Effective Methods for Renal Washout on $^{18}F$-FDG PET/CT)

  • 김성수;김종철;신용철;이선도;이남주;김승수;이춘호
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.55-59
    • /
    • 2010
  • FDG PET/CT 검사에서 FDG는 신장 및 요료계를 통하여 배설된다. 이 방사능의 배설을 촉진 시키는 방법을 비교 및 분석하여 각 의료기관의 실정에 맞는 방법을 선택하는데 도움을 주고자 한다. 8개월간 본원에서 PET/CT 검사를 시행한 환자 중 신장에 병적 병변이 없고 기능이 정상인 환자 총 30명을 대상으로 하였다. FDG-PET/CT 기본검사를 마친 환자들을 무작위로 10명씩 다음 세 집단으로 나눠 지연검사를 촬영하였다. (1) 1시간 대기한 집단(Delay group), (2) 수분을 약 700 mL 섭취한 후 1시간 대기한 집단(Hydration group), (3) 이뇨제를 정맥주사하고 30분 대기한 집단(Lasix group). 평가는 육안평가와 정량분석을 하였다. 육안평가는 기본검사와 비교하여 각 집단별 지연검사 영상에서 신장의 방사능 배설을 네 단계로 나누어 비교 및 분석하였다. 정량분석은 기본검사의 표준화섭취계수에서 지연검사의 표준화섭취계수의 감소율을 측정하여 신장 방사능의 배설률로 활용하였다. 육안평가상 Lasix group이 가장 배설이 잘 되었고 그 다음은 Hydration group이었다. Delay group은 효과적인 배설이 이루어지지 않았다. 정량분석 결과 신장방사능 배설률은 Delay group $9.2{\pm}20.7%$, Hydration group $28.1{\pm}22.8%$, Lasix group $29.5{\pm}23.1%$이었다. Delay group과 Hydration group간, Delay group과 Lasix group간의 배설률은 통계적으로 유의한 차이를 보였다. Hydration group과 Lasix group간은 유의한 차이가 없었다. 본 연구에서 이뇨제를 사용하는 것이 신장의 방사능 배설을 촉진시키는데 가장 효과적임을 확인할 수 있었다. 또한 수분을 섭취하는 방법도 비슷한 효과를 보였으며 수분 섭취 없이 지연영상을 얻는 것은 효과가 없음을 확인 하였다. 이상의 방법들을 각 의료기관 실정에 맞게 적용함으로써 영상의 질 향상에 도움을 줄 수 있을 것이다.

  • PDF

저선량 흉부전산화단층촬영의 흡기 영상과 폐기능이 정상인 성인에서 호기 말 폐 감쇄도 증가 정도와 연령 및 흡연과의 연관성 (Correlation between Expiratory Increase of Lung Attenuation and Age and Smoking in the Subjects with Normal Inspiratory Low Dose CT and Pulmonary Function Test)

  • 권성연;황용일;윤호일;이재호;이춘택;이경원
    • Tuberculosis and Respiratory Diseases
    • /
    • 제65권6호
    • /
    • pp.457-463
    • /
    • 2008
  • 연구배경: 호기말에 흉부 촬영을 시행하면 폐 내의 공기의 부피가 감소되어 폐 감쇄도가 증가한다. 이런 폐 감쇄도의 변화가 국소적으로 저하되는 공기 가둠 현상에 대해서는 일부 연구들이 있었으나 전체 폐의 전반적인 감쇄도 변화에 대한 연구는 거의 없고, 특히 정상인을 대상으로 한 연구는 거의 없다. 저자들은 호흡기 질환이 없으며 폐기능 및 흡기 전산화단층촬영이 정상 소견이고 호기 영상에서 국소적인 공기 가둠 현상이 없는 100명을 대상으로 연구를 수행하였다. 방 법: 흉부 전산화단층촬영 영상에서 24개의 지점을 정하고, 흡기 및 호기 시 각 지점에서 폐 음영도를 측정한 후 호기말 폐 감쇄도 증가와 흡연량, 연령 사이의 상관 관계를 알아보았다. 결 과: 연구 대상 100명의 연령은 중앙값 49.0세(범위 25~71세)였고, 평균 흡연량은 $22.5{\pm}17.0$갑년이었다. 연령과 폐 감쇄도의 증가 사이에는 유의한 음의 상관관계가 있었으며 이는 흡연의 효과를 보정하였을 때에도 유지되었고, 연령을 기준으로 세 군으로 나누어 폐 감쇄도의 증가 정도를 비교하였을 때에도 유의한 차이가 있었다. 흡연량과 호기말 폐 감쇄도의 증가 사이에는 유의한 음의 상관관계가 관찰되었으나 연령을 보정하였을 때에는 유의성이 감소하였다. 결 론: 흡기-호기 시의 폐의 전반적인 감쇄도 변화 정도는 연령과 상관관계가 있으며, 노화를 반영할 가능성이 있다.

멀티 모달리티 데이터 활용을 통한 골다공증 단계 다중 분류 시스템 개발: 합성곱 신경망 기반의 딥러닝 적용 (Multi-classification of Osteoporosis Grading Stages Using Abdominal Computed Tomography with Clinical Variables : Application of Deep Learning with a Convolutional Neural Network)

  • 하태준;김희상;강성욱;이두희;김우진;문기원;최현수;김정현;김윤;박소현;박상원
    • 한국방사선학회논문지
    • /
    • 제18권3호
    • /
    • pp.187-201
    • /
    • 2024
  • 골다공증은 전 세계적으로 주요한 건강 문제임에도 불구하고, 골절 발생 전까지 쉽게 발견되지 않는 단점을 가지고 있습니다. 본 연구에서는 골다공증 조기 발견 능력 향상을 위해, 복부 컴퓨터 단층 촬영(Computed Tomography, CT) 영상을 활용하여 정상-골감소증-골다공증으로 구분되는 골다공증 단계를 체계적으로 분류할 수 있는 딥러닝(Deep learning, DL) 시스템을 개발하였습니다. 총 3,012개의 조영제 향상 복부 CT 영상과 개별 환자의 이중 에너지 X선 흡수 계측법(Dual-Energy X-ray Absorptiometry, DXA)으로 얻은 T-점수를 활용하여 딥러닝 모델 개발을 수행하였습니다. 모든 딥러닝 모델은 비정형 이미지 데이터, 정형 인구 통계 정보 및 비정형 영상 데이터와 정형 데이터를 동시에 활용하는 다중 모달 방법에 각각 모델 구현을 실현하였으며, 모든 환자들은 T-점수를 통해 정상, 골감소증 및 골다공증 그룹으로 분류되었습니다. 가장 높은 정확도를 갖는 모델 우수성은 비정형-정형 결합 데이터 모델이 가장 우수하였으며, 수신자 조작 특성 곡선 아래 면적이 0.94와 정확도가 0.80를 제시하였습니다. 구현된 딥러닝 모델은 그라디언트 가중치 클래스 활성화 매핑(Gradient-weighted Class Activation Mapping, Grad-CAM)을 통해 해석되어 이미지 내에서 임상적으로 관련된 특징을 강조했고, 대퇴 경부가 골다공증을 통해 골절 발생이 높은 위험 부위임을 밝혔습니다. 이 연구는 DL이 임상 데이터에서 골다공증 단계를 정확하게 식별할 수 있음을 보여주며, 조기에 골다공증을 탐지하고 적절한 치료로 골절 위험을 줄일 수 있는 복부 컴퓨터 단층 촬영 영상의 잠재력을 제시할 수 있습니다.