• 제목/요약/키워드: CT Room

검색결과 165건 처리시간 0.021초

종합병원 영상의학과 CT 검사실의 조도 측정에 의한 향상 방안 (The Method of Improvement by Illuminance Measurement of the CT Scan Room in a General Hospital Radiology)

  • 권대철;양성환;강영식
    • 대한설비관리학회지
    • /
    • 제23권4호
    • /
    • pp.51-56
    • /
    • 2018
  • Computed tomography (CT) scan room in the department of radiology is very necessary to maintain pleasant and proper illuminance to relieve fatigue and inconvenience because it affects the work environment to the radiologist. Accordingly, this paper describes the method for measurement of illuminance that exposed to an environmental elements in a CT scan room of the hospital. Therefore, the purpose of this paper is to propose an optimal environment of CT scan room based on the measurement of illuminance. In addition, the 5 point method by KS C7612 was applied to measure the illuminance with illuminometer (Unfors xi light probe) in the CT scan room. In result of this paper, minimum value and maximum value of illuminance in the CT scan room was measured 212.7 lux and 354.8 lux, respectively. The illuminance of CT scan room was lower than KS A 3011. Finally, the work environment in CT scan room should provide higher illuminance for the comfortable environment of radiologists and patients.

방사선 누설선량 조사를 통한 방어시설과 누설선량 평가방법에 대한 문제점 연구 : 부산, 경남 지역 CT실을 중심으로 (Indicating the Problem of Shielding Design and the Way of Estimating Radiation Leakage for CT Rooms located through Survey of Radiation Leakage : in the case of Busan and Gyung-nam Area)

  • 양원석;최준혁;신운재;민병인
    • 한국콘텐츠학회논문지
    • /
    • 제13권11호
    • /
    • pp.768-777
    • /
    • 2013
  • 이 연구는 CT(computed tomography)검사 중 발생하는 방사선 누설선량(radiation leakage)으로부터 종사자 및 일반인의 피폭을 최소화하기 위한 것이다. 부산, 경남에 위치한 대학병원 7곳과 종합전문요양병원 4곳의 CT실을 대상으로 하였다. 누설선량 측정 장소로는 1) 조정실 내 감시창 벽면의 지면으로부터 3m 높이 2) 조정실 내 특정 지점 3) 조정실 내 종사자 출입문 4) 환자 출입문을 선정하였다. 그 결과 M병원의 종사자 출입문에서 가장 높은 누설선량이 나타났다. 각각의 측정값은 고전적 방법에 의한 주당 최대 누설선량으로 환산하였다. 그 결과 1) $5.97{\pm}0.23$, 2) $0.50{\pm}0.02$, 3) $10.00{\pm}0.11$, 4) $2.37{\pm}0.47$ mR/week로 주당 최대 누설선량 허용치(<100 mR/week)이하였다. 하지만 측정 최대 누설선량을 기록한 M병원의 조정실 내 종사자 출입문을 실험적 방법으로 계산한 결과 $118.31{\pm}17.72$ mR/week(>100 mR/week)로 나타났다. 조정실 지면으로부터 3 m 이상의 높이에서의 누설선량은 조정실내부에 영향을 끼쳤다(p<0.05). 따라서, 누설선량의 피해를 줄이기 위해, 주당 최대 누설선량 산출 방법에 대한 개선과, 조정실 차폐벽의 차폐체를 3 m 이상으로 할 것을 제안 한다.

시스템 개선을 통한 핵의학 검사실의 공간 선량률 감소방안 (Solution to Decrease Spatial Dose Rate in Laboratory of Nuclear Medicine through System Improvement)

  • 문재승;신민용;안성철;유문곤;김수근
    • 한국의료질향상학회지
    • /
    • 제20권1호
    • /
    • pp.60-73
    • /
    • 2014
  • Objectives: This study aims at decreasing spatial dose rate through work improvement whilst spatial dose rate is the cause of increasing personal exposure dose which occurs in the process of handling radioisotope. Methods: From February 2013 until July 2013, divided into "before" and "after" the improvement, spatial dose rate in laboratory of nuclear medicine was measured in gamma image room, PET/CT-1 image room, and PET/CT-2 image room as its locations. The measurement time was 08:00, 12:00 and 17:00, and SPSS 21.0 USA was opted for its statistical analysis. Result: The spatial dose rate at distribution worktable, injection table, the entrance to the distribution room, and radioisotope storage box, which had showed high spatial dose rate, decreased by more than 43.7% a monthly average. The distribution worktable, that had showed the highest spatial dose rate in PET/CT-1 image room, dropped the rate to 42.3% as of July. The injection table and distribution worktable in the PET/CT-2 image room also showed the decline of spatial dose rate to 89% and 64.4%, respectively. Conclusion: By improving distribution process and introducing proper radiation shielding material, we were able to drop the spatial dose rate substantially at distribution worktable, injection table, and nuclide storage box. However, taking into account of steadily increasing amount of radioisotope used, strengthening radiation related regulations, and safe utilization of radioisotope, the process of system improvement needs to be maintained through continuous monitoring.

핵의학 검사실내 세균 분석 (Analysis of the Bacteria in Nuclear Medicine)

  • 신성규;이효영
    • 대한안전경영과학회지
    • /
    • 제19권2호
    • /
    • pp.95-100
    • /
    • 2017
  • In this study, the bacterial contamination level of equipments and devices in the nuclear medicine department of a university hospital was investigated. CNS was detected from the sample collected from the door opening button of the nuclear medicine department. Bacillus sp. was detected from the table and CNS with Bacillus sp. were detected from the control button at the PET-CT room no.1. Also, CNS was detected from the table and the control button at the PET-CT room no.2. In the distribution room no.1, CNS and Bacillus sp. were detected while CNS being detected from the distribution room no.2 and CNS with Bacillus sp. being detected from the distribution room no.3. In the injection room, Enterrococcus faecium and Pontoea sp. were detected. On the table of the ecsomatics room, Pontoea sp. was detected. Bacillus sp. was detected from the inside of the syringe Pb shield and CNS was detected from the outside. Enterrococcus faecium was detected from the Gamma camera table and Bacillus sp. was detected from the door grip. On the chair at the patient waiting room, Pseudomonas aeruginosa abd Bacillus sp. were detected. Therefore, it was understood that infection should be prevented by securely sterilizing examination devices after each examination, maintaining cleanliness by regular sterilization of waiting chairs and such objects with a number of direct contacts with patients, and infection education for the features of nuclear department.

Interference Issuses of Radio Frequency Identification Devices in Magnetic Resonance Imaging Systems and Computed Tomography Scan

  • Periyasamy, M.;Dhanasekaran, R.
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.295-301
    • /
    • 2015
  • We evaluated certain issues related to magnetic resonance imaging (MRI) coupled with the use of active 2.5 GHz radio frequency identification (RFID) tags for patient identification using low field (0.3 T) MRI and computed tomography (CT) scans. We also investigated the performance of the RFID reader located outside the MRI room by considering several factors. A total of ten active RFID tags were exposed to several MRI sequences and X-rays of CT scan. We found that only card type active RFID tags are suitable for patient identification purpose in MRI environment and both wristbands as well as card tags were suitable for the same in CT environment. Severe artifacts were found in the captured MRI and CT images when the area of the imaging was in proximity to the tags. No external factors affected the performance of active RFID reader stationed outside the MRI scan room.

전산화단층촬영실 방사선사의 VDT증후군 자각증상에 관한 연구 (A Study on the Subjective Symptoms of VDT Syndrom in Radiological Technologists at CT Room)

  • 임상묵;이병남;이강우
    • 대한방사선협회지
    • /
    • 제29권1호
    • /
    • pp.12-24
    • /
    • 2003
  • Purpose : The aim of this study was to investigate the variables affecting video display terminal (VDT) syndrom and prevent the harm of VDT syndrom Materials and Methods : A questionnarie study was performed with 170 radiotechnologists working at CT room

  • PDF

COVID-19 환자에서 음압격리들것을 이용한 흉부 CT 검사에 대한 전문가 의견 설문: 영상품질과 감염위험 (Expert Opinion Questionnaire About Chest CT Scan Using A Negative Pressure Isolation Strecher in COVID-19 Patients: Image Quality and Infection Risk)

  • 진광남;남보다;신재민;황성호
    • 대한영상의학회지
    • /
    • 제84권4호
    • /
    • pp.891-899
    • /
    • 2023
  • 목적 급성호흡기질환인 코로나바이러스감염증-19 (coronavirus disease 2019; 이하 COVID-19) 환자를 대상으로 한 음압격리들것(negative presurre isolation stretcher; 이하 NPIS)을 이용한 흉부 전산화단층촬영(이하 CT) 방식에 대해 전문의들의 경험과 의견을 확인하고자 하였다. 대상과 방법 격리입원 중인 COVID-19 환자에게 NPIS를 이용한 흉부 CT 검사를 시행했던 9개 의료기관 소속 27명의 전문의들을 대상으로 1) 조영증강 흉부 CT가 필요한 경우, 2) NPIS를 이용한 흉부 CT의 영상품질, 그리고 3) CT 조영제주사를 위한 NPIS 개방과 CT 검사실의 오염을 주제로 설문조사를 진행하였다 결과 조사대상인 9개의 의료기관들은 기관당 한 해 평균 116건의 COVID-19관련 흉부 CT 검사를 NPIS와 함께 진행했으며. 전체 검사 건수 중 평균 24건(21%)이 조영증강 흉부 CT였다. 설문에 참여한 호흡기내과 전문의 9명 중 5명(56%)은 환자의 혈중 D-dimer 이상이 확인되면 조영증강 CT가 필요하다고 의견을 밝혔다. 한편 영상의학과 전문의 9명 모두는 NPIS로 인한 흉부 CT 영상의 품질은 폐렴 또는 폐혈전 진단이 가능한 수준이라 답하였다. 또한 감염내과 전문의 9명 중 5명(56%)은 NPIS의 개방으로 인한 CT 검사실의 이차감염은 소독을 통해 예방할 수 있는 수준으로 생각하고 있었다. 결론 격리입원 중인 COVID-19 환자에서 NPIS와 함께 흉부 CT를 진행하더라도 CT의 품질은 진단이 가능한 수준이며 NPIS가 CT 검사실 내에서 잠시 개방되더라도 CT 검사실의 감염확산 위험은 높지 않은 것으로 전문의들은 인식하고 있었다.

외국의 컴퓨터 단층촬영 장치의 방어시설 문헌 조사 (Reviews of Radiation Protection and Shielding for Computed Tomography in Foreign Countries)

  • 장건호;양달모;성동욱;이광용;김혁주
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.276-284
    • /
    • 2008
  • 전 세계적으로 컴퓨터 단층 촬영 장치(Computed Tomography, CT)의 임상 적용이 환자의 질병의 조기 진단에 매우 중요하게 사용되고 있으며 사용 빈도 또한 매년 급증하고 있다. 새로운 종류의 CT 장치들이 병변을 조기 진단하기 위하여 개발되고 있다. 이 방사선 발생 장치에 의한 환자나 작업 종사자들의 방사선 피폭이 불가피 할 수도 있다. 국내에서는 CT 장치에 대한 구체적인 방사선 방어나 방사선 시설에 대한 구체적인 규정이 확립되어 있지 않다. 본 논문에서는 국내에서의 CT 사용시설에 대한 방사선 방어 시설과 사용 기준에 대한 규정 마련에 토대를 이루기 위하여 외국에서의 CT 장비에 대한 방사선 방어 및 방사선 차폐에 대한 규정을 조사하였다. 조사방법으로는 구글 검색을 이용한 특정 키워드 검색과 방사선 관련 업무를 수행하는 특정 웹사이트를 직접 검색하는 방법을 사용하였다. 검색결과 캐나다, 미국, 영국 등의 국가에서 국가의 실정에 맞는 가이드라인을 사용하고 있었으나, 아직 이중 에너지 CT에 대한 가이드라인은 없는 것으로 나타났다. 한국에서도 국내 실정에 적합한 CT 장비에서의 방사선 방어, 차폐, 환자나 작업종사자 및 일반인에 대한 방사선 피폭에 대한 가이드라인의 설정이 필요하다고 생각된다.

  • PDF

PET검사 작업환경에 있어서 APRON의 방어에 대한 고찰 (A Consideration of Apron's Shielding in Nuclear Medicine Working Environment)

  • 이성욱;김승현;지봉근;이동욱;김정수;김경목;장영도;방찬석;백종훈;이인수
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.110-114
    • /
    • 2014
  • PET/CT기기의 발달로 인한 검사시간의 단축과 대중화로 인해 검사건수도 꾸준히 증가하고 있다. 이는 방사선 작업종사자의 피폭선량도 함께 증가시키는 결과를 초래한다. 본 연구는 PET/CT 검사에 있어서 에너지가 강한 $^{18}F-FDG$를 apron을 착용 시 방사선 차폐율을 측정하고 차폐효과를 알아보고자 하였다. 또한 $^{99m}TC$과의 차폐율을 비교하여 방사선 작업종사자의 피폭선량을 최소화하는 것에 목적을 두고 진행하였다. 실험방법은 2013년 5월 2일부터 5월 10일까지 8일간 PET/CT 검사를 위해 본원을 방문한 10명의 환자를 대상으로 하였고 PET/CT 주요 작업공간인 $^{18}F-FDG$ 분배실, 환자 안정실($^{18F}$주사 후 환자 대기장소), PET/CT 검사실 모두 3곳을 선정하여 Apron장착 전과 apron장착 후로 나누어 선량율 변화를 측정하였다. 정확한 측정을 위해서 환자 또는 Source부터의 거리는 1 m로 고정하였다. 또한 Apron의 선량감소율을 비교하고자 $^{99m}TC$의 source에도 같은 방법을 적용하여 측정하였다. 측정결과 $^{18F}FDG$ 분배실에서 L-BLOCK만 있는 경우 평균 $0.32{\mu}Sv$였고 L-block+apron의 경우 $0.23{\mu}Sv$이였으며 두 경우의 선량과 선량율의 차이는 각각 $0.09{\mu}Sv$, 26%로 나타났다. 안정실에서 apron이 없는 경우 평균 $33.1{\mu}Sv$였고 apron이 있는 경우 평균 $22.3{\mu}Sv$였다. 두 경우의 선량과 선량율의 차이는 각각 $10.8{\mu}Sv$, 33%로 나타났다. PET/CT실에서의 apron이 없는 경우 평균 $6.9{\mu}Sv$였고 apron이 있는 경우 평균 $5.5{\mu}Sv$였다. 두 경우의 선량과 선량율의 차이는 각각 $1.4{\mu}Sv$, 25%로 나타났다. $^{99m}TC$은 apron이 없는 경우 평균 $23.7{\mu}Sv$였고 apron이 있는 경우 평균 $5.5{\mu}Sv$였다. 두 경우의 선량과 선량율의 차이는 각각 $18.2{\mu}Sv$, 77%나타났다. 실험결과 환자에게 투여한 후의 $^{99m}TC$의 경우 평균 77%의 차폐율을 나타내었고 $^{18}F-FDG$의 경우 평균 27%의 비교적 낮은 차폐율을 보였다. source 자체만을 비교하였을 때에 $^{18}F-FDG$는 17%의 차폐율을 보였고 $^{99m}TC$은 77%의 차폐율을 보였다. $^{99m}TC$에 비해 낮은 차폐효과이지만 $^{18}F-FDG$ 역시 apron에 대한 차폐효과가 있음을 알 수 있었다. 그러므로 PET/CT 검사에 있어서 $^{18}F-FDG$과 같은 고에너지에 맞는 apron을 착용한다면 방사선 작업종사자의 피폭선량을 최소화 할 수 있을 것으로 사료된다.

  • PDF

영남대학교병원의 환자안전을 위한 정도관리의 기초자료 분석 (Basic Data Analysis of the Quality Control for Patient Safety in Department of Radiation Oncologyat Yeungnam University Hospital)

  • 오세안;김성규;예지원;강민규;이준하;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제26권2호
    • /
    • pp.112-117
    • /
    • 2015
  • 미국의학물리학회(AAPM) TG-100 위원회에서 제시하고 있는 가이드 라인에 준하여 환자 안전에 대한 정도관리를 수립하기 위하여 영남대학교병원 방사선종양학과에서 환자를 치료하는 중에 발생한 오류들을 중심으로 오류 유형을 분석하여, 환자중심의 방사선치료를 시행할 때 환자 안전을 위한 정도관리의 가이드 라인을 정립하고자 한다. 방사선종양학과에서 방사선 치료를 하는데 있어서 일으킬 수 있는 오류들을 분석하여 오류를 일으키는 빈도와 오류가 일어날 때 환자 에게 미치는 심각성과 오류가 일어났을 때 감지하지 못하고 지나치는 확률을 점수로 평가하고자 한다. 오류를 일으킬 수 있는 곳으로는 CT 모의치료실, 치료계획실, 치료실로 나누어 조사하였다. CT 모의치료실에서는 고정기구 사용의 오류가 위험중요지수의 값이 60으로 가장 높았고, 모의치료 정보입력의 오류가 6으로 가장 낮게 나타났다. 치료계획실에서는 선량계산 모델 선택의 오류가 위험중요지수의 값이 168로 가장 높았고, 환자의 치료 시작일 오류가 36으로 가장 낮게 나타났다. 치료실에서는 테이블 Bar 오류가 위험중요지수의 값이 252으로 가장 높았고, 체중변화 오류가 190을 나타내었으며, 배게 오류가 24로 가장 낮게 나타났다.