• Title/Summary/Keyword: CT Contents

Search Result 219, Processing Time 0.025 seconds

Efficient CT Image Segmentation Algorithm Using both Spatial and Temporal Information

  • Lee, Sang-Bock;Lee, Jun-Haeng;Lee, Samyol
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2004.11a
    • /
    • pp.505-510
    • /
    • 2004
  • This paper suggests a new CT-image segmentation algorithm. This algorithm uses morphological filters and the watershed algorithms. The proposed CT-image segmentation algorithm consists of six parts: preprocessing, image simplification, feature extraction, decision making, region merging, and postprocessing. By combining spatial and temporal information, we can get more accurate segmentation results. The simulation results illustrate not only the segmentation results of the conventional scheme but also the results of the proposed scheme; this comparison illustrates the efficacy of the proposed technique. Furthermore, we compare the various medical images of the structuring elements. Indeed, to illustrate the improvement of coding efficiency in postprocessing, we use differential chain coding for the shape coding of results.

  • PDF

The methods of distinguishing between HCC and HH in Liver CT scan (Liver CT 영상에서 간세포암과 간혈관종 구별에 대한 연구)

  • Hwang, In-gil;Ko, Seong-Jin;Choi, Seok-Yoon
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.173-174
    • /
    • 2015
  • 간에서 발생하는 악성종양과 양성종양의 대표적 질환 으로는 간세포암(Hepatocelluar carci- noma, HCC)과 간혈관종(Hepatic hemangioma, HH)이다. CT검사를 이용한 진단에 있어서 두 질환은 시간변화에 따른 조영증강양상 차이가 나타난다. Liver 3-phase computed tomography검사를 시행하여 시간별 조영증강 양상을 알아보았다. 본 연구는 조영제 주입전, 동맥기(35sec), 문맥기(70sec), 지연기(180sec)에 대한 Enhan -cement Pattern 변화와 HU(Hounsfield unit)값 변화, pixel값 변화의 관찰로서 검증하였다. 실험결과 HU를 사용한 방법에서 의미있게 구분되었고 임상적용 시 판독에 도움을 줄 것으로 생각한다.

  • PDF

Computed Tomography and Quality Management (컴퓨터단층촬영장치와 품질관리)

  • Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.221-233
    • /
    • 2020
  • CT(computed tomography, CT) examinations is one of the most useful diagnostic equipment for identifying information in the human body in diagnostic radiology. Recently, the number of CT scans is increasing every year due to the high reliability of CT scans. Increasing the number of tests will accelerate the aging of CT devices, which is why the importance of quality management for CT devices is on the rise. Particularly in CT, quality management refers to a behavior of figuring out and correcting all sorts of hindrance factors that can cause all the problems related to the equipment associated with the diminishment of diagnosed area due to the reduction of image quality in clinical imaging in advance and maintaining a consistent level of image quality and obtaining a proper image. Here, these researchers aim to summarize and report the general contents of quality management in CT.

Medical Radiation Exposure in Children CT and Dose Reduction (소아 CT 촬영시 방사선 피폭과 저감화 방법)

  • Lee, Jeong-Keun;Jang, Seong-Joo;Jang, Young-Ill
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.1
    • /
    • pp.356-363
    • /
    • 2014
  • Recently pediatric CT has been performed by reduced dose according to tube current modulation이라고, this fact has a possibility more reduce a dose because of strong affect depend on tube current modulation. Almost all MDCT snow show and allow storage of the volume CT dose index (CTDIvol), dose length product (DLP), and effective dose estimations on dose reports, which are essential to assess patient radiation exposure and risks. To decrease these radiation exposure risks, the principles of justification and optimization should be followed. justification means that the examination must be medically indicated and useful. Results is using tube current modulation이라고 tend to the lower kV, the lower effective dose. In case of use a low dose CT protocol, we found a relatively lower effective dose than using tube current modulation. Average effective dose of our studies(brain, chest, abdomen-pelvis) less than 47%, 13.8%, 25.7% of germany reference dose, and 55.7%, 10.2%, 43.6% of UK(United Kingdom) reference dose respectively. when performed examination for reduced dose, we must use tube current modulation and low dose CT protocol including body-weight based tube current adaption.

Design and Implementation of Web-based Problem Management System for CT Radiological Technologist Education (CT 전문방사선사 교육을 위한 웹기반 문항관리 시스템의 설계 및 구현)

  • Shin Yong-Won;Koo Bong-Oh;Shim Choon-Bo
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.1
    • /
    • pp.27-35
    • /
    • 2005
  • Recently, despite of the rapid progress of information technology in the medical and health fields, the development and management of problem sets about medical and education contents related with radiological technologist has been still achieved by manual and offline method using document editor. In this study, the unique web-based problem management system is designed and implemented. That system can efficiently manage and present various kind of problem set about integrated education and personal license without time and space limitations in order to improve the efficiency of supplementary training and to obtain the professional license for CT radiological technologist. The proposed system is composed of administration module and user module. The former supports several functions such as problem creation, problem categorization, user management, and adjustment of leveled assessment. On the other hand, the latter functions examination applying , problem retrieval, personal score retrieval, and interpretation viewing, and so on. In addition, our system is expected as a useful and practical system which provides problem interpretation and analysis of score results after applying for the examination. It can elevate ability of learning and information interchange among them preparing for CT professional radiological technologist licensing examination

  • PDF

Comparison of the Breast Dose based on the Existence of the Bismuth Breast Protection Shield for Automatic Exposure Control and Manual Exposure Control with the Coronary Artery CT Angiography

  • Kim, Sang-Tae;Kang, Sang-Koo;Kim, Chong-Yeal
    • International Journal of Contents
    • /
    • v.7 no.4
    • /
    • pp.103-107
    • /
    • 2011
  • The effective dose and the organ absorbed dose, which are given to a breast in the cases of using and not using the bismuth breast protection shield for the protection of a breast with the coronary artery CT angiography, have been measured and compared for the manual exposure control (MEC)and the automatic exposure control (AEC). In the cases of using and not using the bismuth breast protection shield, it has been found that the measured dose shows the reduction of about 23 to 26% for the MEC and about 22 to 25% for the AEC when the shield is used compared to the case of not using it. By comparing the shield and non-shield cases for the AEC and the MEC, it can be said that the value measured by carrying out the scanning process with the AEC mode has decreased by about 24 to 30% compared to the case of applying the MEC mode. Such a result shows that it is recommended to use the AEC mode for the reduction of the patient's exposure dose during the CT examination.

Study of Optimum Contrast Medium Quantity during Abdominal CT using Dual Energy Technique (복부 CT 검사 시 이중에너지 기법을 통한 적정한 조영제 양에 관한 연구)

  • Kang, Min;Choi, Nam-Gil;Han, Jae-Bok;Song, Jong-Nam
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.211-212
    • /
    • 2014
  • 단일에너지 복부 검사에서 사용했던 조영제 양 대비 30%, 40%, 50%, 60%, 70%로 각각 설정하여 영상을 획득한 후 대동맥, 하대정맥, 간문맥, 간실질에 관심영역을 설정하여 조영증강정도(houns -field unit; HU)를 구하여 단일에너지에서 측정된 부위와의 값을 비교 분석하였다. 그 결과 기존대비 60%로 조영제를 설정한 군에서는 대동맥 HU : $210.80{\pm}13.609$, 하대정맥 HU : $190.40{\pm}25.215$, 간문맥 $198.40{\pm}21.232$, 간실질 HU : $119.20{\pm}7.98$로 각각 측정되었으며. 단일에너지 복부 CT 검사는 대동맥 HU : $205.40{\pm}16.426$, 하대정맥 HU : $188.20{\pm}21.476$, 간문맥 HU : $195.40{\pm}22.744$, 간실질 HU : $121.00{\pm}6.595$ 이었다. 따라서 이중에너지를 이용하여 복부 조영 CT검사를 시행할 때 조영제의 양을 60%로 설정한 후 검사하는 것이 각 장기에서의 단일에너지 조영검사시와 비슷한 조영증강정도를 획득할 수 있다.

  • PDF

CT Scan Findings of Rabbit Brain Infection Model and Changes in Hounsfield Unit of Arterial Blood after Injecting Contrast Medium (토끼 뇌감염 모델의 CT 소견과 조영제 주입 후 동맥혈의 Hounsfield Unit의 변화)

  • Ha, Bon-Chul;Kwak, Byung-Kook;Jung, Ji-Sung
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.9
    • /
    • pp.270-279
    • /
    • 2012
  • This paper explores CT findings of a rabbit brain infection model injected with Escherichia coli and investigates the changes in Hounsfield unit (HU) of arterial blood over time. The brain infection model was produced by injecting E. coli $1{\times}10^7$ CFU/ml, 0.1 ml through the burr hole in the calvarium; 2~3 mm in depth from the dura mater, and contrast-enhanced CT, dynamic CT and arterial blood CT images were gained. It was found that various brain infections such as brain abscess, ventriculitis and meningitis. The CT image of brain abscess showed a typical pattern which the peripheral area was strongly contrast-enhanced while the center was weakly contrast-enhanced. The CT image of ventriculitis showed a strong contrast-enhancement along the lateral ventricle wall, and the CT image of meningitis showed a strong contrast-enhancement in the area between the telencephalon and the diencephalon. In dynamic CT images, the HU value of the infection core before injecting contrast medium was $31.01{\pm}3.55$. By 10 minutes after the injection, the value increased gradually to $40.36{\pm}3.76$. The HU value in the areas of the marginal rim where was hyper-enhanced showed $47.23{\pm}3.12$ before contrast injection, and it increased to $63.59{\pm}3.31$ about 45 seconds after the injection. In addition, the HU value of the normal brain tissue opposite to the E. coli. injected brain was $39.01{\pm}3.24$ before the injection, but after the contrast injection, the value increased to $49.01{\pm}4.29$ in about 30 seconds, and then it showed a gradual decline. In the arterial blood CT, the HU value before the contrast injection was $87.78{\pm}6.88$, and it increased dramatically between 10 to 30 seconds until it reached a maximum value of $749.13{\pm}98.48$. Then it fell sharply to $467.85{\pm}62.98$ between 30 seconds to 45 seconds and reached a plateau by 60 seconds. Later, the value showed a steady decrease and indicated $188.28{\pm}25.03$ at 20 minutes. Through this experiment, it was demonstrated that the brain infection model can be produced by injecting E. coli., and the characteristic of the infection model can be well observed with contrast-enhanced CT scan. The dynamic CT scan showed that the center of the infection was gradually contrast-enhanced, whereases the peripheral area was rapidly contrast-enhanced and then slowly decreased. As for arterial blood, it increased significantly between 10 seconds to 30 seconds after the contrast medium injection and decreased gradually after reaching a plateau.

Anti-Oxidative and Anti-Inflammatory Effects of Cheongajihwang-Tang Extract on RAW264.7 Cells (청아지황탕(靑蛾地黃湯)의 RAW264.7 Cell에서 항산화 및 항염증 효능 연구)

  • Yoon, Jeong-won;Kim, Soon-Joong;Park, Dong-Su
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.26 no.3
    • /
    • pp.51-58
    • /
    • 2016
  • Objectives This study was designed to investigate whether the Cheongajihwang-Tang (CT) has an inhibitory effect association with oxidation or inflammation in RAW264.7 cells. Methods Cytotoxic activity of CT extract on RAW264.7 cells was evaluated by using 3-[4, 5-dimethylthiazol-2-yl]-2, 5-diphenyltetrazolium bromide (MTT) solution. Nitric oxide production was measured using Griess reagent system. The total phenolic contents and 1,1-Diphenyl-2-picrylhydrazyl (DPPH) radical scavenging activity was measured to evaluate the anti-oxidative effects of CT. Dichlorofluorescin diacetate (DCFH-DA) has been used as a substrate for measuring intracellular oxidant production. Results Cheongajihwang-Tang does not impair the cell viability in tested concentration. CT showed anti-oxidative effects in vitro by decreasing electron donating ability, and also showed anti-inflammatory effects suppressing NO and ROS expression in LPS induced RAW264.7 activation. CT inhibited the generation of intracellular ROS production as dose dependant manner. Conclusions CT has anti-oxidative effects and anti-inflammatory activities. These results indicate that CT extract has an anti-inflammatory activities via anti-oxidative effects.

Design of Computational Thinking Instruction Based on ARCS Model in Liberal Arts Education (교양교육에서 ARCS 모형 기반의 컴퓨팅 사고력 수업 설계)

  • Jun, Soo-jin;Shin, Chwa-Cheol
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.90-93
    • /
    • 2019
  • Recently, as SW education has been emphasized in college, interest in Computing Thinking (CT) class at the liberal level has increased. In order to effectively educate students, various methods of teaching and learning are required to reduce the burden on CT education and motivation of students. The purpose of this study is to design teaching and learning using ARCS model to improve learners' learning motivation and learning achievement in CT course as liberal arts education. In this study, the learning elements of CT were selected based on previous research on the characteristics of education in the liberal arts education of the university and analysis of the CT content. In addition, Keller 's ARCS learning motive model was selected to match the instructional tactics according to the motivational factors of Attention, Relevance, Confidence, and Satisfaction. In order to effectively teach these CT contents, detailed strategies based on the ARCS model were designed and presented weekly.

  • PDF