• Title/Summary/Keyword: CT(computed tomography)

Search Result 2,603, Processing Time 0.034 seconds

Usefulness of modified ambu® in patients who need artificial ventilation (인공 환기가 필요한 환자에서 변형된 수동식 인공호흡기(Ambu®)의 유용성)

  • Ha, Kee Soo;Moon, Il Hong;Lee, Hee Sun;Shin, Dong Han;Eun, So Hee;Eun, Baik-Lin;Hong, Young Sook;Lee, Joo Won
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.11
    • /
    • pp.1194-1201
    • /
    • 2006
  • Purpose : The comatose mentality can be catastrophic, especially if the condition is severe or the duration is prolonged. Therefore, delayed diagnosis can result in a poor outcome or death. The best radiologic modality to differentiate from cerebral lesions in patients suffering from cerebral diseases is magnetic resonance imaging (MRI) rather than computed tomography (CT). Special apparatuses with metal materials such as ventilators, and cardiac pacemakers belonging to patients cannot be located in the magnetic field. We aimed to exhibit the possibility of examining MRI, maintaining ventilation at a relative long distance by means of modified $Ambu^{(R)}$. Methods : Self-inflating bags as a sort of a manual ventilator, connected with relatively long extension tubes instead of mechanical ventilators, were adopted to obtain MRI. PVC (polyvinyl chloride) extension tubes had different lengths and diameters. Lengths were 1, 2, and 3 cm and diameters were 15, and 25 mm. The work of breathing and expiratory changes of expiratory tidal volume (TVe), minute volume of expiration (MVe), peak inspiratory pressure (PIP) were measured by use of the mechanical ventilator, $Servoi^{(R)}$, as the alteration of TVi (inspiratory tidal volume), extension tube lengths and diameters with other values fixed. Results : Measured TVe and MVe by ventilator were the same values with control at every TVi, regardless of extension tube lengths and diameters, but PIP were increased with the rise of TVi, tube lengths, with decline of tube diameters, these were statistically significant. Conclusion : MRI examination can be carried out with a self-inflating bag connected with an extension tube at a long distance in patients who need artificial ventilation.

Usefulness of Chest High-Resolution CT in Patients with Chronic Cough Below 2 Years of Age (2세 미만의 만성 기침 환아에서 흉부 고해상 전산화 단층 촬영의 유용성)

  • Kim, Myung Hyun;Kim, Jung Hee;Lim, Dae Hyun;Son, Byong Kwan;Lee, Kyung-Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.3
    • /
    • pp.339-345
    • /
    • 2002
  • Purpose : The purpose of this study was to evaluate the clinical usefulness of chest high-resolution computed tomography(HRCT) in patients with chronic coughs or persistent wheezing with normal chest X-ray finding. Methods : We reviewed the charts, chest X-rays, and HRCT findings of patients with chronic coughs or persistent wheezing of less than 2 years of age. The records were sourced from the Department of Pediatrics, Inha University Hospital covering the period from July, 1999 to June, 2000. Chronic cough was defined as a cough which was prolonged for more than 3 weeks. Results : The sample consisted of 24 patients(male 15 and female 9, mean age $4.7{\pm}3.8$ months old). Among them, 16 patients showed normal findings(66.7%) and 8 patients showed abnormal (33.3%) in simple chest X-rays. Among 16 patients who had the normal chest X-rays, 13 patients showed abnormal chest HRCT findings(81.3%) such as air space consolidation of the dependent portion(62.5%), bronchiolitis obliterans(12.5%), and bronchopulmonary dysplasia(6.3%). Conclusion : We suggest that the chest HRCT is a useful diagnostic tool in the evaluation of patients with chronic cough or persistent wheezing with normal chest X-ray, especially below 2 years of age.

A Study on Prospective Plan Comparison using DVH-index in Tomotherapy Planning (토모 테라피 치료 시 선량 체적 히스토그램 표지자를 이용한 치료계획 비교에 관한 연구)

  • Kim, Joo-Ho;Cho, Jeong-Hee;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Yoon, Jong-Won;Kim, Dong-Wook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.113-122
    • /
    • 2007
  • Purpose: We proposed the method using dose-volume Histogram index to compare prospective plan trials in tomotherapy planning optimization. Materials and Methods: For 3 patients in cranial region, thorax and abdominal region, we acquired computed tomography images with PQ 5000 in each case. Then we delineated target structure and normal organ contour with pinnacle Ver 7.6c, after transferred each data to tomotherapy planning system (hi-art system Ver 2.0), we optimized 3 plan trials in each case that used differ from beam width, pitch, importance. We analyzed 3 plan trials in each region with isodose distribution, dose-volume histogram and dose statistics. Also we verified 3 plan trials with specialized DVH-indexes that is dose homogeneity index in target organ, conformity index around target structure and dose gradient index in non-target structures. Results: We compared with the similarity of results that the one is decide the best plan trial using isodose distribution, dose volume histogram and dose statistics, and the another is using DVH-indexes. They all decided the same plan trial to better result in each case. Conclusion: In some of case, it was appeared a little difference of results that used to DVH-index for comparison of plan trial in tomotherapy by special goal in it. But because DVH-index represented both dose distribution in target structure and high dose risk about normal tissue, it will be reasonable method for comparison of many plan trials before the tomotherapy treatments.

  • PDF

Stress Patterns in the Reconstructed Double Bundles of the Anterior Cruciate Ligament in Response to an Anterior Tibial Load and Rotatory Load: an Analysis using a 3-Dimensional Finite Element Model (삼차원 유한 요소 모델을 이용한 전방십자인대 이중다발 재건술 후 전방 전위 및 회전 부하에 따른 이식건 응력 양상 분석)

  • Seo, Young-Jin;Song, Si Young;Ahn, Jung Tae;Kim, Yoon-Sang;Ko, Jun Ho;Jang, Seong-Wook;Yoo, Yon-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.160-166
    • /
    • 2012
  • Purpose: The aim of this study was to determine the patterns of the stress distribution within the reconstructed anterior cruciate ligament (ACL) double bundles in response to an anterior tibial load and rotatory load at $45^{\circ}$ flexed knee model by use of a 3-dimensional finite element analysis (FEM). Materials and Methods: The $0^{\circ}$ and $45^{\circ}$ flexed 3-D knee model were reconstructed based on the high resolution computed tomography (CT) images from the right knee of a healthy male subject. To simulate double bundle ACL reconstruction, in $0^{\circ}$ analytic model, four 7 mm diameter tunnels were created at the center of each anteromedial (AM) and posterolateral (PL) footprints on the femur and tibia. The grafts were inserted into the corresponding bone tunnels and then reconstructed knee model was flexed to $45^{\circ}$. As a next step, the 5 mm anterior tibial load and internal rotational load of $10^{\circ}$ were applied on the final Computer aided design (CAD) model. And then stress patterns of each bundle were assessed using a finite element analysis. Results: In response to the 5 mm of anterior tibial load, the AM bundle showed increased stresses around the tibial and femoral attachment sites; especially in the anterior aspect of the bundle. In the PL bundle, the highest stress concentration was also noticed on the anterior aspect of the bundle. Under $10^{\circ}$ internal rotational load, the stress concentration was predominant around the anterior aspect of the tibial attachment site within the AM bundle. The PL bundle also showed highest stress concentration on the anterior aspect of the bundle. Conclusion: Although the stress patterns were not identical among the AM and PL bundle, there were common trends in the stress distribution. The stress concentration was predominant on the anterior aspect of both bundles in response to the anterior tibial load and rotatory load.

  • PDF

Calculation of Renal Depth by Conjugate-View Method Using Dual-head Gamma Camera (이중 헤드 감마 카메라를 이용한 Conjugate-View 계수법에 의한 신장 깊이 도출)

  • Kim, Hyun-Mi;Suh, Tae-Suk;Choe, Bo-Young;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.378-388
    • /
    • 2001
  • Purpose: In this study, we developed a new method for the determination of renal depth with anterior and posterior renal scintigrams in a dual-head gamma camera, considering the attenuation factor $e^{-{\mu}x}$ of the conjugate-view method. Material and Method: We developed abdomen and kidney phantoms to perform experiments using Technetium-99m dimercaptosuccinic acid ($^{99m}Tc$-DMSA). The phantom images were obtained by dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators (ICONf, Siemens). The equation was derived from the linear integration of omission ${\gamma}$-ray considering attenuation from the posterior abdomen to the anterior abdomen phantom surface. The program for measurement was developed by Microsoft Visual C++ 6.0. Results : Renal depths of the phantoms were derived from the derived equations and compared with the exact geometrical values. Differences between the measured and the calculated values were the range of 0.1 to 0.7 cm ($0.029{\pm}0.15cm,\;mean{\pm}S.D.$). Conclusion: The present study showed that the use of the derived equations for renal depth measurements, combined with quantitative planar imaging using dual-head gamma camera, could provide more accurate results for individual variation than the conventional method.

  • PDF

Diagnosis of Interstitial Lung Disease -Comparison of HRCT, Transbronchial Lung Biopsy and Open Lung Biopsy- (간질성 폐질환의 진단 -HRCT, 경기관지폐생검, 개흉폐생검의 비교-)

  • Park, Jae-Seuk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.1
    • /
    • pp.65-74
    • /
    • 1999
  • Background : Open lung biopsy(OLB) has conventionally been regarded as the gold standard for the diagnosis in interstitial lung disease. With recent advances in diagnostic technique such as high resolution computed tomography(HRCT), and transbronchial lung biopsy(TBLB) which provide relatively accurate diagnosis of ILD, it is necessary to reevaluate the role of these methods in the diagnosis of ILD. Methods: We carried out a retrospective analysis of nineteen patients who underwent OLB at Dankook University Hospital for the diagnosis of acute and chronic ILD, between May 1995 and June 1998. By reviewing the medical records, the demographic findings, underlying conditions, HRCT and TBLB findings, OLB diagnosis, therapy after OLB, and complication of OLB were evaluated. Results: Thirteen patients(68.4%) had chronic ILD(symptom duration over 2 weeks prior to OLB), and six patients(31.6%) had acute ILD(symptom duration less than 2 weeks). Specific diagnosis were reached in 92%(12/13) of chronic ILD(5 bronchiolitis obliterans organizing pneumonia(BOOP), 2 constrictive bronchiolitis, 3 usual interstitial pneumonia, 1 hypersensitivity pneumonitis, 1 eosinophilic pneumonia), and in all patients of acute ILD(5 acute interstitial pneumonia, 1 pneumocystis carinii pneumonia). HRCT were performed in all patients and a correct first choice diagnosis rate of HRCT was 42%(5/12) in chronic ILD. In chronic ILD patients, 62%(8/13) received specific therapy(steroid therapy in 7 patients and moving in one patient), after OLB, but in acute ILD, all patients received specific therapy(steroid therapy in 5 patients and steroid and antibiotic therapy in one patient) after OLB. The in-hospital mortality after OLB was 5.3%(1/19). Conclusion: OLB is an excellent diagnostic technique with relatively low complications in patients with ILD. Therefore OLB should be considered in patients with ILD when the specific diagnosis is important for the treatment, especially in patients with acute ILD.

  • PDF

Evaluation of the accuracy of two different surgical guides in dental implantology: stereolithography fabricated vs. positioning device fabricated surgical guides (제작방법에 따른 임플란트 수술 가이드의 정확성비교: stereolithography와 positioning device로 제작한 수술 가이드)

  • Kwon, Chang-Ryeol;Choi, Byung-Ho;Jeong, Seung-Mi;Joo, Sang-Dong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.271-278
    • /
    • 2012
  • Purpose: Recently implant surgical guides were used for accurate and atraumatic operation. In this study, the accuracy of two different types of surgical guides, positioning device fabricated and stereolithography fabricated surgical guides, were evaluated in four different types of tooth loss models. Materials and methods: Surgical guides were fabricated with stereolithography and positioning device respectively. Implants were placed on 40 models using the two different types of surgical guides. The fitness of the surgical guides was evaluated by measuring the gap between the surgical guide and the model. The accuracy of surgical guide was evaluated on a pre- and post-surgical CT image fusion. Results: The gap between the surgical guide and the model was $1.4{\pm}0.3mm$ and $0.4{\pm}0.3mm$ for the stereolithography and positioning device surgical guide, respectively. The stereolithography showed mesiodistal angular deviation of $3.9{\pm}1.6^{\circ}$, buccolingual angular deviation of $2.7{\pm}1.5^{\circ}$ and vertical deviation of $1.9{\pm}0.9mm$, whereas the positioning device showed mesiodistal angular deviation of $0.7{\pm}0.3^{\circ}$, buccolingual angular deviation of $0.3{\pm}0.2^{\circ}$ and vertical deviation of $0.4{\pm}0.2mm$. The differences were statistically significant between the two groups (P<.05). Conclusion: The laboratory fabricated surgical guides using a positioning device allow implant placement more accurately than the stereolithography surgical guides in dental clinic.

Alteration of Coagulation and Fibrinolysis System According to Right Ventricular Dysfunction in Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환에서 우심실 기능 부전에 따른 혈액응고 및 섬유소용해계 변화)

  • Kim, Young;Jang, Yoon Soo;Kim, Hyung Jung;Kim, Se Kyu;Chang, Joon;Ahn, Chul Min;Kim, Sung Kyu;Kwak, Jin Young;Choi, Jin Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.6
    • /
    • pp.625-630
    • /
    • 2006
  • Background: Pulmonary hypertension in COPD patients is the result of a direct effect of tobacco smoke on the intrapulmonary vessels with the abnormal production of the mediators that control vasoconstriction, vasodilatation, and vascular cell proliferation, which ultimately lead to aberrant vascular remodeling and physiology. COPD patients are prone to the developmint of an acute and chronic thromboembolism with an elevation of the plasma procoagulant and fibrinolytic markers However, the roles of the coagulation and fibrinolysis system on the right ventricular dysfunction in COPD patients are not well defined. We examined the alteration of the coagulation and fibrinolysis system in COPD patients according to the right ventricular function measured using cardiac multidetector computed tomography (MDCT). Methods: The right ventricular ejection fraction (RVEF) was measured using cardiac MDCT in 26 patients who were diagnosed with COPD according to the definition of the GOLD guideline. The plasma level of thrombin antithrombin (TAT) and plasminogen activator inhibitor (PAI)-1 were measured using an enzyme linked immunoassay. Results: The plasma TAT was markedly elevated in COPD patients ($10.5{\pm}19.8{\mu}g/L$) compared with those of the control ($3.4{\pm}2.5{\mu}g/L$) (p<0.01). However, the plasma PAI-1 in COPD patients ($29.6{\pm}20.7ng/mL$) was similar to that in the controls. The plasma TAT showed a significant inverse relationship with the RVEF measured by the cardiac MDCT in COPD patients (r=-0.645, p<0.01). However, the plasma PAI-1 did not show a relationship with the RVEF (r=0.022, p=0.92). Conclusion: These results suggest that the coagulation system in COPD patients is markedly activated, and that the plasma level of TAT might be a marker of a right ventricular dysfunction in COPD patients.

Diagnosis and Treatment of Endobronchial Actinomycosis (기관지 방선균증의 임상적 고찰)

  • Choi, Jae Chol;Koh, Won-Jung;Kwon, Yong Soo;Ryu, Yon Ju;Yu, Chang-Min;Jeon, Kyeongman;Kang, Eun Hae;Suh, Gee Young;Chung, Man Pyo;Kim, Hojoong;Kwon, O Jung;Kim, Tae Sung;Lee, Kyung Soo;Han, Joungho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.6
    • /
    • pp.576-581
    • /
    • 2005
  • Background : Thoracic actinomycosis is a relatively uncommon anaerobic infection caused by Actinomyces israelii. There have been only a few case reports of endobronchial actinomycosis. The aim of this study was to evaluate the clinical manifestation and treatment of endobronchial actinomycosis. Material and Methods : Seven patients with endobronchial actinomycosis, who were diagnosed in the past 10 years, were retrospectively reviewed. Results : Cough and sputum were the most common symptoms. The chest radiograph and computed tomography showed necrotic consolidation (n=3), atelectasis (n=2), mass (n=1) and an endobronchial nodule (n=1). Proximal broncholithiasis was observed in five patients. All cases were initially suspected to have either lung cancer or tuberculosis. In these patients, the median duration of intravenous antibiotics was 3 days (range 0-12 days) and the median duration of oral antibiotics was 147 days (range 20-412 days). Two patients received oral antibiotic therapy only. There was no clinical evidence of a recurrence. Conclusion : Endobronchial actinomycosis frequently manifests as a proximal obstructive calcified endobronchial nodule that is associated with distal post-obstructive pneumonia. The possibility of endobronchial actinomycosis is suggested when findings of broncholithiasis are present at chest CT. The traditional recommendation of 2-6 weeks of intravenous antibiotics and 6-12 months of oral antibiotic therapy are not necessarily essential in all cases of endobronchial actinomycosis.

Usefulness of Customized Cervical Spine Immobilizer in Head & Neck Image-Guided Radiation Therapy with Tomotherapy® (토모테라피를 이용한 두경부암 영상유도 방사선 치료 시 개인별 경추고정용구의 유용성 평가)

  • Jin, Sung Eun;Chang, Se Wuk;Choi, Jung Hoan;Kim, Min Joo;Ahn, Seung Kwon;Lee, Sang Kyu;Cho, Jung Heui
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.65-71
    • /
    • 2018
  • Purpose : Standardized pillow may not support patient's individual cervical spine thoroughly when head and neck radiation therapy with $Tomotherapy^{(R)}$. Therefore, the purpose of this study was to make a comparative analysis for the difference of using standardized pillow only and using customized cervical spine immobilizer with standardized pillow. Materials and Methos : The head and neck cancer patients who are treated image-guided radiation therapy(IGRT) with $Tomotherapy^{(R)}$ were divided into two groups, 20 patients using standardized pillow only, and 20 patients using customized cervical spine immobilizer with standardized pillow. We achieved 20 mega-voltage computed tomography(MVCT) image per patient, compared curvature of the cervical spine in MVCT with curvature of the cervical spine in CT-simulation. Results : Results of comparative analysis were curvature consistency 95.9 %, maximum error of distance 41.9 mm, average distance error per fractionation 19.4 mm, average standard deviation 1.34 mm in case of using standardized pillow only, curvature consistency 98.9 %, maximum error of distance 12.9 mm, average distance error per fractionation 5.8 mm, average standard deviation 0.59 mm in case of using customized cervical spine immobilizer with standardized pillow. Conclusion : Using customized cervical spine immobilizer shows higher reproducibility and low distance error, therefore customized cervical spine immobilizer could be useful for head and neck cancer patients who need radiation therapy.

  • PDF