Assessment of Code Requirments on Minimum Shear Reinforcement in High-Strength RC Beams (RC 보의 강도증진에 따른 최소전단철근 규준의 적합성 평가에 관한 연구)

  • 윤영수;원종필;장일영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.289-294
    • /
    • 1996
  • This paper persents the assessment of the minimum shear reinforcement requirements in normal, medium and high-strength reinforced concrete beams. Twelve shear tests were conducted on full-scale beam specimens having design concrete compressive strengths of 35, 70 and 100 MPa. Different amounts of minimum shear reinfrocement were investigated, including the amounts required by Korean Concrete Standard (KCI88), JCI86, ACI89 (revised 1992) and CSA94 standard. The performance of the different amounts of shear reinforcement are discussed in terms of the shear capacity, the ductility and the crack control at service load levels. An assessment of code provisions for minimum shear reinforcememt, and the prediction and comparison of the ultimate shear capacity are also presented.

  • PDF

Strategic Utilization of Fiber Reinforced UHSC in Slab-Column Connections

  • Yoon, Young-Soo;Lee, Joo-Ha;Lee, Seung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.79-82
    • /
    • 2005
  • This study reports on the structural characteristics of slab-column connections using an ultra-high-strength-fiber-reinforced concrete from new and retrospective data. The parameters investigated were the ' puddling ' of ultra-high-strength-fiber-reinforced concrete and the use of high-strength concrete in the slab. The effects of these parameters on the punching shear capacity, negative moment cracking, and stiffness of the two-way slab specimens are investigated. Furthermore, the ACI Code (2002), the CSA Standard (1994), the BS Standard (1985) and the CEB-FIP Code (1990) predictions are compared to the experimental results obtained from some slab-column connections tested in this experiment and those tested by other investigators. The beneficial effects of the ultra-high-strength-fiber-reinforced concrete puddling and of the use of high-strength concrete are demonstrated. It is also concluded that the punching shear strength of slab-column connections is a function of the flexural reinforcement ratio.

  • PDF

ASR Resistance of Ternary Blended Binder Adding Ultra Fine Mineral Admixture (고분말도 광물성 혼화재를 혼입한 삼성분계 결합재의 ASR 저항성 평가)

  • Jeon, Sung Il;Ahn, Sang Hyeok;An, Ji Hwan;Yun, Kyung Ku;Nam, Jeong-Hee
    • International Journal of Highway Engineering
    • /
    • v.15 no.5
    • /
    • pp.81-89
    • /
    • 2013
  • PURPOSES : This study is to evaluate ASR(alkali silica reactivity) resistance of ternary blended binder adding ultra fine mineral admixture. METHODS : This study analyzes ASR expansion using ASTM C 1260 and 1567. RESULTS : This study showed that the fineness of mineral admixture had no effect on ASR expansion. The expansion of ternary blended binder(UFFA 20%+FGGBS 10%) were below 0.1%, and this binder met the ASR standard. Also when adding the CSA expansion agent, ASR expansion slightly decreased. The expansion of latex modified mixture increased by 80% comparing plain mixture. CONCLUSIONS : Ternary blended binder met the ASR standard, and this binder is available in concrete bridge deck overlay.

Destructive and Non-destructive Tests of Bamboo Oriented Strand Board under Various Shelling Ratios and Resin Contents

  • Maulana, Sena;Gumelar, Yuarsa;Fatrawana, Adesna;Maulana, Muhammad Iqbal;Hidayat, Wahyu;Sumardi, Ihak;Wistara, Nyoman Jaya;Lee, Seung Hwan;Kim, Nam Hun;Febrianto, Fauzi
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.519-532
    • /
    • 2019
  • The objectives of this study were to evaluate the effects of shelling ratio and resin content on the properties of bamboo oriented strand board (BOSB) from betung (Dendrocalamus asper) and to determine the correlation between the results of dynamic and static bending tests. Strands were steam-treated at $126^{\circ}C$ for 1 h under 0.14 MPa pressure and followed by washing with 1% NaOH solution. Three-layer BOSB with the core layer perpendicular to the surface was formed with shelling ratios (face:core ratio) of 30:70; 40:60; 50:50; 60:40 and binded with 7% and 8% of phenol formaldehyde (PF) resin with the addition of 1% of wax. The evaluation of physical and mechanical properties of BOSB was conducted in accordance with the JIS A 5908:2003 standard and the results were compared with CSA 0437.0 standard for commercial OSB (Grade O-1). Non-destructive testing was conducted using Metriguard Model 239A Stress Wave Timer which has a wave propagation time from 1 to $9,999{\mu}s$ and a resolution of $1{\mu}s$. BOSB with 8% resin content showed better physical and mechanical properties than those with 7% resin content. The increase of the face layer ratio improved the strength of BOSB in parallel direction to the grain. The results suggested that shelling ratio of 50:50 could be used as a simple way to reduce PF resin requirements from 8% to 7% and to meet the requirements of CSA 0437.0 standard. The results of non-destructive and destructive tests showed a strong correlation, suggesting that non-destructive test can be used to estimate the bending properties of BOSB.

A study on the equivalent circuit test method using Std. IEEE 112 (IEEE 112 등가회로 시험법의 고찰)

  • Lee, I.W.;Ryu, D.W.;Byun, K.B.;Choi, U.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.63-65
    • /
    • 2003
  • In the case of the large motors which can't direct load tests, IEEE 112 equivalent circuit test was selected instead of the circle diagram method in the newly KEPIC's code. According to the change of code, Hyosung established an equivalent circuit test method based on Standard IEEE 112. In this paper, we compared the test results between IEEE 112 and other standards, CSA C-390, JEC2137 for the large motors.

  • PDF

Design of a Floating Point Multiplier for IEEE 754 Single-Precision Operations (IEEE 754 단정도 부동 소수점 연산용 곱셈기 설계)

  • Lee, Ju-Hun;Chung, Tae-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.778-780
    • /
    • 1999
  • Arithmetic unit speed depends strongly on the algorithms employed to realize the basic arithmetic operations.(add, subtract multiply, and divide) and on the logic design. Recent advances in VLSI have increased the feasibility of hardware implementation of floating point arithmetic units and microprocessors require a powerful floating-point processing unit as a standard option. This paper describes the design of floating-point multiplier for IEEE 754-1985 Single-Precision operation. Booth encoding algorithm method to reduce partial products and a Wallace tree of 4-2 CSA is adopted in fraction multiplication part to generate the $32{\times}32$ single-precision product. New scheme of rounding and sticky-bit generation is adopted to reduce area and timing. Also there is a true sign generator in this design. This multiplier have been implemented in a ALTERA FLEX EPF10K70RC240-4.

  • PDF

Tensile Properties of GFRP Rebars Based on Resin Mix Proportions (수지배합에 따른 GFRP 보강근의 인장 특성)

  • Park, Ji-Sun;You, Young-Chan;Park, Young-Hwan;You, Young-Jun;Kim, Hyeong-Yeol;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.561-564
    • /
    • 2006
  • The tensile characteristics of four types GFRP (glass fiber reinforced polymer) reinforcing bars with different resin mix proportions and fiber volume fraction were analyzed experimentally. Four types of GFRP reinforcing bars containing approximately 66 or 70% fiber volume fraction with A or B rein mix proportions were considered in this test. All testing procedures including specimens preparation, set-up of test equipments and measuring devices were made according to the recommendations of CSA Standard S806-02. From the test results, it was found that GFRP reinforcing bars containing approximately 70% fiber volume fraction with A rein mix proportion showed the higher tensile strength than that of the others due to the higher fiber volume fraction and proper resin mix proportion.

  • PDF

Bond Characteristics of Hybrid Fiber Polymer Reinforcing bars with Different Relative Rib Area (하이브리드 FRP 보강근의 상대 리브면적에 따른 부착 특성)

  • Park Ji Sun;You Young Chan;Park Young Hwan;You Young Jun;Kim Hyeong Yeol;Kim Keung Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.201-204
    • /
    • 2005
  • The bond characteristics of two types hybrid FRP (fiber reinforced polymer) reinforcing bars with different rib geometry were analyzed experimentally. Two types of hybrid FRP. reinforcing bars such as spiral and cross type with different relative rib area were considered in this test. All testing procedures including specimens preparation, set-up of test equipments and measuring devices were made according to the recommendations of CSA Standard S806-02. From the test results, it was found' that cross type hybrid FRP reinforcing bars showed the higher bond strength than that of spiral type's due to the higher relative rib area.

  • PDF

Bond Characteristics of Glass Fiber Reinforced Polymer Rebar according to the Bar Location (GFRP 보강근의 단면 위치에 따른 부착특성)

  • Park, Ji-Sun;Park, Young-Hwan;You, Young-Jun;Hwang, Geum-Sic;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.197-200
    • /
    • 2006
  • The bond characteristics of three different types of glass fiber reinforced polymer(GFRP) reinforcing bars with different surface deformations were studied experimentally. Each specimen consisted of a concrete prism, 150 by 150 mm on each edge, with the longer axis in the vertical direction. Two rebars were embedded in each specimen, perpendicular to the longer axis and parallel to and equidistant from the sides of the prism. In vertical direction, one rebar was located at 75 mm from the bottom of the prism, and the other 225 mm from the bottom. All testing procedures including specimens preparation, set-up of test equipments and measuring devices were made according to the recommendations of CSA Standard S806-02.It was found that the bottom reinforcements showed higher bond stress than that of the top rebars.

  • PDF

Development of Hybrid Fiber Reinforced Polymer Reinforcing Bars and Evaluation of the Bond Properties (하이브리드 FRP 보강근의 형상개발과 부착성능 평가)

  • Park, Ji-Sun;Park, Young-Hwan;You, Young-Jun;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.629-632
    • /
    • 2006
  • The various rib geometry of hybrid fiber reinforced polymer (FRP) reinforcing bars were analyzed by finite element method. From the analysis result, two types of hybrid FRP reinforcing bars such as spiral and cross type with the same dimension of rib geometry were fabricated in this study. To evaluate the bond properties of them, direct pull-out test was performed. All testing procedures including specimens preparation, set-up of test equipments and measuring devices were made in accordance with the recommendations of CSA Standard S806-02. From the test results, it was found that cross type hybrid FRP reinforcing bars showed the highest bond strength than that of the others due to the higher relative rib area.

  • PDF