• Title/Summary/Keyword: CS616

Search Result 8, Processing Time 0.024 seconds

A Study on Measuring and Calibration Method using Time Domain Reflectometry Sensor under Road Pavement (Time Domain Reflectometry 방식을 이용한 도로 하부의 함수비 계측 및 보정 방안에 관한 연구)

  • Cho, Myung-Hwan;Lee, Yoon-Han;Kim, Nak-Seok;Park, Joo-Young
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.2
    • /
    • pp.23-30
    • /
    • 2010
  • The research presents moisture content measuring and calibration method of road pavement, especially asphalt concrete pavement for performance evaluation or remaining life prediction using Time Domain Reflectometry(TDR) sensor, CS616 made by campbell INC. Before calibration test of CS616, accomplished a sensor verification tests. Verification test items were covering depth and interference effect of two CS616 sensors, temperature effects between $5^{\circ}C\sim25^{\circ}C$ and compaction ratio effects. Covering depth and interference effects between two CS616 sensors were just small and the effects of temperature and compaction ratio effected a Volumetric Moisture Contents at $\pm6%$ under disregard appeared with the fact that was possible. Also, obtained the calibration equation of the subgrade and subbase course, $R^2$ showed above of all 0.9.

A Study on the Calibrate Method of Volumetric Moisture Content Measuring Sensor(CS616) (TDR(Time Domain Reflectometry) 방식의 함수센서 (CS616) 보정방법에 관한 연구)

  • Cho, Myung-Hwan;Kim, Hong-Man;Jee, Kee-Hwan;Park, Joo-Young
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.89.1-89.1
    • /
    • 2010
  • 본 연구는 토양의 함수비를 측정하기 위하여 TDR(Time Domain Reflectometry, 시간영역 광전자파 분석기) 방식의 함수센서(CS616)에 대한 올바른 보정시험을 제안하기 위하여 피복두께, 센서간 간섭 영향, 온도의 영향 및 다짐율 변화에 대한 실내 시험을 수행하였다. 시험 결과 피복두께, 센서간 간섭 영향 및 온도의 영향은 체적함수비의 크기에 미치는 영향은 크지 않은 것으로 나타났으며, 오히려 보정시험시 정확한 체적함수비 조건을 유지하는 것이 중요할 것으로 사료된다. 또한 보정시험을 수행할 때 다짐율까지 고려한 시험을 수행하는 노력에 비하여 얻어지는 체적함수비의 정확도의 크기는 다짐율과 주기를 고려하여 얻어진 회귀식을 살펴보면 주기에 비하여 상대적으로 영향이 작은 것으로 사료된다.

  • PDF

Water Content Calibration of Time-Domain Reflectometry Probe Using Laboratory Model Test (실내모형실험을 통한 TDR 함수량계의 현장 함수비 보정)

  • Shin, Eun Chul;Ryu, Byung Hyun;Park, Jeong Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.2
    • /
    • pp.1-11
    • /
    • 2013
  • Water content of subgrade soil in water supply systems has a large effect on performance. Many researchers lately make use of time-domain reflectometry (TDR) probes to measure the soil water content of subgrade soil from monitoring. The laboratory calibration test of TDR probe should be performed with soil field, because TDR probe can cause an error by type, gradation, density, and temperature of soil. This study shows the laboratory calibration test using TDR CS616, TDR-P3, TDR-T3. The calibration equations of TDR were then proposed. It was confirmed from the study that the data of TDR probe monitored in field could be used to estimate the freezing, unfrozen water content, and matric suction of soil.

Measurement of the Nonlinear Optical Properties by use of the Far-Field Phase Modulation Method (Far-field 위상 변조량 측정법을 이용한 광학매질의 비선형 특성 측정)

  • 김성훈;양준목;김용평;이영우;신동주;정영붕
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.3
    • /
    • pp.168-174
    • /
    • 1998
  • We have measured nonlinear refractive index and nonlinear absorption coefficient of optical materials by using a far-field phase modulation technique. The phase variation of the probe beam in the nonlinear material is transformed into the spatial phase modulation in the far-field so that the spatial distribution of the optical intensity in conjunction with the computer simulation analysis can give the nonlinear optical constants. We have obtained the nonlinear refractive indices and nonlinear absorption coefficient of $CS_2$ and $BaF_2$ by fitting the experimental values and numerical simulation analysis of far-field measurements. The nonlinear refractive indices of $CS_2$ and $BaF_2$were obtained as $1.2{\times}10^{-11}$ esu and $1.0{\times}10^{-13}$ esu, respectively at 616 nm, and the nonlinear absorption coefficient of BaF$_2$as $5.0{\times}10^{-11}$cm/W at 308nm. These measured values were in good agreement with previous reports.

  • PDF

Development of Calibration Model and Analysis of Soil Water Content using Time-Domain Refelctometry Probe in LTPP Sections (LTPP 구간에서 TDR 방식 함수량계를 이용한 현장함수비 보정모델 개발과 함수비 분석 연구)

  • Kim, Boo-Il;Jeon, Sung-Il
    • International Journal of Highway Engineering
    • /
    • v.7 no.4 s.26
    • /
    • pp.103-112
    • /
    • 2005
  • Water content of sub-layer in pavement systems has a large effect on pavement performance. Many researchers lately make use of time-domain reflectometry(TDR) probes to measure the soil water content of sub-layer from field monitoring. The laboratory calibration test of TDR probe should be performed with soil field, because TDR probe can cause an error by type, gradation, density, and temperature of soil. This study performed the laboratory calibration test of TDR probe(CS616) with subgrade and subbase material in long term pavement performance(LTPP) sections. And the calibration equations of TDR probe(CS616) were then proposed. It was confirmed from the study that the data of TDR probe monitored in field could be used to estimate the freezing, unfrozen water content, and matric suction of soil.

  • PDF

An NMR Study on Complexation of Cesium Ion by p-tert-Butylcalix[6]arene Ethyl Ester

  • Chung, Kee-Choo;Namgoong, Hyun;Lee, Jo-Woong
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.609-616
    • /
    • 2004
  • Complexation of cesium ion by p-tert-butylcalix[6]arene ethyl ester was studied by NMR spectroscopy in nonpolar $CDCl_3$ and polar acetone-$d_6$ and the results were compared with each other. Analysis of temperature dependent $^1H$ spectra and titration curves reveals that both solvents result in a 1 : 1 cone-form complex with nonpolar $CDCl_3$yielding a more tightly bound one than acetone-$d_6$. Unexpectedly, at very low temperature, we have found that two phenyl ring proton peaks of equal intensity appear both in $CDCl_3$and in acetone-$d_6$ solution which gradually collapse and eventually coalesce into a single line as temperature is raised. This observation could be interpreted in terms of the chemical exchange through direct and/or indirect interconversion between two equivalent conformations possible the complex in both solvents over the temperature range observed. And broadening of $^{133}Cs$ (I = 7/2) nmr line with increasing temperature has also been observed, indicating the exchange of $^{133}Cs$ ion between the complex and the solvent. From numerical fitting of lineshape changes for one-dimensional $^1H$ and $^{133}Cs$ spectra, the exchange rate constants and other relevant parameters for this conformational interconversion and the complex-solvent exchange were deduced.

Change of Contrast Sensitivity in Peripheral Vision Following Eccentric Viewing Training (중심외주시 훈련 후 주변시야에서의 대비감도 변화)

  • Seo, Jae-Myoung;Lee, Ki-Young;Lim, Yong-Moo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.99-104
    • /
    • 2014
  • Purpose: This study was to investigate the functional improvement in peripheral vision following eccentric viewing training. Methods: 14 subjects with normal vision took a part with their right eye, peripheral retinal which is $20^{\circ}$ lateral area from the fovea was examined for contrast sensitivity(CS). Eccentric viewing training was performed for 21days with an hour image viewing and examination was repeated. Results: The critical durations for 0.7 cpd were increased 2.67(467 ms) for pre-eccentric viewing training to 2.79(616 ms) for post-eccentric viewing training (p>0.05). The critical durations for 3.0 cpd were also increased 2.53(341 ms) for pre-eccentric viewing training to 3.04(1102 ms) for post-eccentric viewing training (p>0.05). Conclusions: It is recommended to use higher spatial frequency with higher CS for eccentric viewing training and to train more frequently for a short time. Moreover, the study on Korean standardizing of the visual rehabilitation for low vision based on the etiology is sorely required.

Comparison of the accuracy of intraoral scanner by three-dimensional analysis in single and 3-unit bridge abutment model: In vitro study (단일 수복물과 3본 고정성 수복물 지대치 모델에서 삼차원 분석을 통한 구강 스캐너의 정확도 비교)

  • Huang, Mei-Yang;Son, Keunbada;Lee, Wan-Sun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.102-109
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the accuracy of three types of intraoral scanners and the accuracy of the single abutment and bridge abutment model. Materials and methods: In this study, a single abutment, and a bridge abutment with missing first molar was fabricated and set as the reference model. The reference model was scanned with an industrial three-dimensional scanner and set as reference scan data. The reference model was scanned five times using the three intraoral scanners (CS3600, CS3500, and EZIS PO). This was set as the evaluation scan data. In the three-dimensional analysis (Geomagic control X), the divided abutment region was selected and analyzed to verify the scan accuracy of the abutment. Statistical analysis was performed using SPSS software (${\alpha}=.05$). The accuracy of intraoral scanners was compared using the Kruskal-Wallis test and post-test was performed using the Pairwise test. The accuracy difference between the single abutment model and the bridge abutment model was analyzed by the Mann-Whitney U test. Results: The accuracy according to the intraoral scanner was significantly different (P < .05). The trueness of the single abutment model and the bridge abutment model showed a statistically significant difference and showed better trueness in the single abutment (P < .05). There was no significant difference in the precision (P = .616). Conclusion: As a result of comparing the accuracy of single and bridge abutments, the error of abutment scan increased with increasing scan area, and the accuracy of bridge abutment model was clinically acceptable in three types of intraoral scanners.