• 제목/요약/키워드: CS104

검색결과 47건 처리시간 0.027초

주조작업장 공기 중 벤젠의 정량 (Determination of Benzene in the Casting Process by GC-MS and GC)

  • 오도석;이병재;이성민;김영주
    • 한국산업보건학회지
    • /
    • 제11권3호
    • /
    • pp.206-211
    • /
    • 2001
  • This article describes identification and quantification of benzene in the casting process. Air samples around the casting process were taken by using personal air sampler attached charcoal tube and desorbed by carbon disulfide. The identification and quantitative analysis of benzene have been performed by GC-MS and GC-FID. Calibration range of standard solutions for benzene was prepared in range from 0.1 to 2 times of TLVs concentrations($1.4{\sim}28{\mu}g/1m{\ell}$ CS2) and the limit of detection was $0.11{\pm}0.002{\mu}g/1m{\ell}$ CS2. Benzene detected in airborne was ranged in 4.0ppb~104.7ppb.

  • PDF

Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions

  • Ozcan Akkal;Ismail Hakki Korkmaz;Funda Bayindir
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권4호
    • /
    • pp.179-188
    • /
    • 2023
  • PURPOSE. This in vitro study aimed to evaluate the performance of digital intraoral scanners in a completely edentulous patient with angled and parallel implants. MATERIALS AND METHODS. A total of 6 implants were placed at angulations of 0°, 5°, 0°, 0°, 15°, and 0° in regions #36, #34, #32, #42, #44, and #46, respectively, in a completely edentulous mandibular polyurethane model. Then, the study model created by connecting a scan body on the implants was scanned using a model scanner, and a 3D reference model was obtained. Three different intraoral scanners were used for digital impressions (PS group, TR group, and CS group, n = 10 in each group). The distances and angles between the scan bodies in these measurement groups were measured. RESULTS. While the Primescan (PS) impression group had the highest accuracy with 38 ㎛, the values of 104 ㎛ and 171 ㎛ were obtained with Trios 4 IOSs (TR) and Carestream 3600 (CS), respectively (P = .001). The CS scanner constituted the impression group with the highest deviation in terms of accuracy. In terms of dimensional differences in the angle parameter, a statistically significant difference was revealed among the mean deviation angle values according to the scanners (P < .001). While the lowest angular deviation was obtained with the PS impression group with 0.185°, the values of 0.499° and 1.250° were obtained with TR and CS, respectively. No statistically significant difference was detected among the impression groups in terms of precision values (P > .05). CONCLUSION. A statistically significant difference was found among the three digital impression groups upon comparing the impression accuracy. Implant angulation affected the impression accuracy of the digital impression groups. The most accurate impressions in terms of both distance and angle deviation were obtained with the PS impression group.

퇴비단 여과액비와 막분리 농축액비를 이용한 고형배지경 양액재배가 고추의 생육과 수량에 미치는 영향 (Effects of Compost Leachate and Concentrated Slurry on the Growth and Yield of Pepper in a Substrate Hydroponic Culture)

  • 류종원
    • 한국축산시설환경학회지
    • /
    • 제15권2호
    • /
    • pp.161-170
    • /
    • 2009
  • 본 연구는 고형배지경 양액재배에서 화학 양액 대체가능성을 검토하기 위하여 여과액비, 농축액비에 양액 및 부산물의 혼합처리가 고추의 생육과 수량에 미치는 영향을 검토하였다. 처리는 질소함량을 기준으로 여과액비, 농축액비에 부산물과 양액을 혼합하는 처리구를 두어 전기 전도도와 pH를 조정하여 고추 양액재배를 실시한 결과를 요약하면 다음과 같다. 1. 여과, 농축액비에는 다량 및 미량원소를 함유하고 있으며 부유물질(SS)이 낮아 수경재배시 관배수의 막힘문제 없이 활용이 가능하였다. 또한 여과, 농축액비는 인산, 칼슘, 마그네슘 함량이 낮고 칼륨이 높은 양분불균형를 나타내었다. 2. 양액재배에서 고추의 합계수량은 여과액비 단독시 용구에서 원예연 표준양액재배 대비 총수량 59%를 나타내었으며 농축액비의 경우 양액 대비 14%에 불과하였다. 퇴비단여과액비+부산물, 농축액비+부산물 처리구의 수량은 대조구 대비 각각 60, 54%를 나타내어 여과액비 단독시 용구와 비슷한 수량을 나타내어 부산물 첨가 효과가 나타나지 않았다. 3. 여과액비와 농축액비에 양액을 50%: 50% 비율로 혼합 처리구의 수량은 표준양액과 대등한 수량을 나타내었다. 결론적으로 여과액비, 농축액비 50%에 양액을 50% 첨가하면 고추 양액 재배에 활용이 가능 할 것으로 판단된다.

  • PDF

막분리 돈분뇨 농축액비를 이용한 양액재배가 토마토의 생육과 수량에 미치는 영향 (Effects of Concentrated Pig Slurry Using Membrane Filter on the Growth and Yield of Tomato in Nutriculture)

  • 류종원;서운갑
    • 한국축산시설환경학회지
    • /
    • 제14권2호
    • /
    • pp.119-128
    • /
    • 2008
  • 본 연구는 양돈농가의 막분리 처리과정에서 U/F막을 통과하고 R/O 처리에서 역류되어 나오는 돈슬러리 농축액비를 제조한 후 농축액비와 양액의 혼합처리가 토마토 생육에 미치는 영향를 검토하기 위하여 수행하였다. 본 연구는 하우스 토마토의 양액재배에서 질소함량을 기준으로 농축액비와 양액의 혼합하는 처리구를 두었다. 처리구는 농축액비 단독처리구(CS 100%), 농축액비 80%+양액 20% 혼합처리구(CS 80%+NS 20%), 농축액비 60%+양액 40% 혼합처리구(CS 60%+NS 40%), 농축액비 40%+양액 60% 혼합처리구(CS 40%+NS 60%), 농축액비 20%+양액 80% 혼합처리구(CS 20%+NS 80%), 양액 100% 단독처리구(NS 100%) 등 6개 처리구를 두었다. 농축액비와 양액혼합처리 후 전기전도도와 pH를 조정하여 토마토의 양액재배를 실시한 결과를 요약하면 다음과 같다. 1. 농축액비는 UF/RO 막 분리 공정을 통하여 SS(suspended solid)의 수치가 15.2로 하우스 양액 재배시 막힘 문제가 없었다. 가축분뇨 농축액비는 질소 및 다양한 식물양분은 함유하여 하우스 추비용 액비로 적합하였으나 질소와 칼륨 함량은 높으나 인산 함량은 낮고 무기태질소 중 $NH_4$ 함량은 높으나 $NO_3$ 함량은 낮은 이화학적 성상을 나타내었다. 2. 막처리 농축액비는 칼리 함량이 상대적으로 높고 질소, 인산 함량이 낮아 농축액비 100% 처리구는 양분의 불균형을 초래하여 양액재배에서 토마토의 지상부의 생육이 지연되고 과중이 감소되었다. 그러나 농축액비 20%+양액 80% 혼합시용구는 대조구인 표준양액과 대등한 토마토 과실 수량를 나타내었다. 따라서 막분리 농축액비 20%에 양액 비료성분을 80% 첨가하여 혼합용액을 조제하면 토마토 양액재배로 활용이 가능 할 것으로 판단된다.

  • PDF

와이브로 기반의 셀간 간섭 제거 기술 성능 분석 (The performance analysis for intercell interference reduction techniques in WiBro networks)

  • 박지호;오영환
    • 대한전자공학회논문지TC
    • /
    • 제43권5호
    • /
    • pp.104-112
    • /
    • 2006
  • 이 논문은 와이브로 시스템에서 심각한 문제가 되고 있는 셀간 간섭에 대한 알고리듬 성능 분석에 관한 것이다. 와이브로 시스템의 경우 주파수 재사용 계수가 1이다. 이는 인접 기지국들이 같은 주파수를 사용한다는 의미이다. 인접 기지국들이 같은 주파수를 사용하므로 셀간 간섭이 생기게 된다. 셀간 간섭은 시스템의 성능과 채널 용량에 큰 문제가 되어 전체적인 성능을 저하시키는 요인이 된다. 이 논문에서는 DCA(Dynamic Channel Allocation), CS(Channel Segregation), IMUFR(Interference Mitigation Using Frequency Reuse), IDMA(Interleave Division Multiple Access), FH-OFDM, CRSA(Conceptual Random Subcarrier Allocation 그리고 HDD 알고리듬을 적용한 셀간 간섭률을 분석하였다.

Compressed Channel Feedback for Correlated Massive MIMO Systems

  • Sim, Min Soo;Park, Jeonghun;Chae, Chan-Byoung;Heath, Robert W. Jr.
    • Journal of Communications and Networks
    • /
    • 제18권1호
    • /
    • pp.95-104
    • /
    • 2016
  • Massive multiple-input multiple-output (MIMO) is a promising approach for cellular communication due to its energy efficiency and high achievable data rate. These advantages, however, can be realized only when channel state information (CSI) is available at the transmitter. Since there are many antennas, CSI is too large to feed back without compression. To compress CSI, prior work has applied compressive sensing (CS) techniques and the fact that CSI can be sparsified. The adopted sparsifying bases fail, however, to reflect the spatial correlation and channel conditions or to be feasible in practice. In this paper, we propose a new sparsifying basis that reflects the long-term characteristics of the channel, and needs no change as long as the spatial correlation model does not change. We propose a new reconstruction algorithm for CS, and also suggest dimensionality reduction as a compression method. To feed back compressed CSI in practice, we propose a new codebook for the compressed channel quantization assuming no other-cell interference. Numerical results confirm that the proposed channel feedback mechanisms show better performance in point-to-point (single-user) and point-to-multi-point (multi-user) scenarios.

멀티콥터의 효율적 멀티미디어 전송을 위한 이미지 복원 기법의 성능 (Performance of Image Reconstruction Techniques for Efficient Multimedia Transmission of Multi-Copter)

  • 황유민;이선의;이상운;김진영
    • 한국위성정보통신학회논문지
    • /
    • 제9권4호
    • /
    • pp.104-110
    • /
    • 2014
  • 본 논문에서는 무인항공기인 방송용 멀티콥터를 이용한 Full-HD급 이상 화질의 이미지를 효율적으로 전송하기 위해 이미지 압축 센싱 기법을 적용하고, Sparse 신호의 효율적 복원을 위해 Turbo 알고리즘과 Markov chain Monte Carlo (MCMC) 알고리즘의 복원 성능을 모의실험을 통해 비교 분석하였다. 제안된 복원 기법은 압축 센싱에 기반하여 데이터 용량을 줄이고 빠르고 오류 없는 원신호 복원에 중점을 두었다. 다수의 이미지 파일로 모의실험을 진행한 결과 Loopy belief propagation(BP) 기반의 Turbo 복원 알고리즘이 Gibbs sampling기반 알고리즘을 수행하는 MCMC 알고리즘 보다 평균 복원 연산 시간, NMSE 값에서 우수하여 보다 효율적인 복원 방법으로 생각된다.

치과용 스캐너 평가를 위한 국제표준모델의 재료 및 표면 상태에 따른 스캔 영상 결과물 비교 연구 (Comparative study on quality of scanned images from varying materials and surface conditions of standardized model for dental scanner evaluation)

  • 박주희;설정환;이준재;이승표;임영준
    • 구강회복응용과학지
    • /
    • 제34권2호
    • /
    • pp.104-115
    • /
    • 2018
  • 목적: 본 연구는 현재 시판되고 있는 구강스캐너를 사용하여 구강스캐너 정확도 평가를 위해 국제표준이 제안하고 있는 모형의 스캔이미지 획득이 가능한 지 분석하고, 이를 통해 표준모델이 가지고 있는 문제점을 파악하는 데 있다. 연구 재료 및 방법: ISO12836과 ANSI/ADA no.132에서 규정하는 국제표준을 참고하여 3D 프린터기를 이용하여 모델을 제작하였으며, 모델스캐너와 두 가지 구강스캐너를 이용하여 스캔을 하였다. 스캔이미지 획득 정도를 3등급으로 분류하여 스캐너의 성능을 비교하였으며, 모델 표면의 상태에 따른 이미지 획득 능력도 비교하였다. 결과: 모델 스캐너가 모든 모델에서 가장 우수한 이미지를 얻을 수 있었으며 TRIOS3는 둥근 형태의 구조물, CS3500은 각진 형태의 구조물에 대한 이미지 재현이 좋은 결과를 보였다. 표준 모델의 표면상태에 따른 스캔이미지 재현에서는 초경석고 모델이 스캐너 종류와 관계없이 가장 우수하였다. 3D 프린팅 모델의 경우, 표면에 파우더 처리를 한 모델에서 가장 우수한 스캔이미지를 얻을 수 있었다. 결론: ISO12836과 ANSI/ADA 132의 표준모델의 경우, 구강스캐너의 field of view (FOV)를 벗어나는 구조물을 스캔할 때 서로 다른 면인 것을 구분하는 기준점이 존재하지 않게 되면 연속적인 스캔 및 정합과정에서 정확한 이미지를 나타내지 못한다는 것을 알 수 있었다. 그러므로 단순한 패턴의 반복과 대칭구조를 가지지 않는 새로운 표준모델이 필요하다고 여겨진다.

Horizontal instability after acromioclavicular joint reduction using the two-hole technique is preferred over the loop technique: a single-blind randomized clinical trial

  • Mardani-Kivi, Mohsen;Asadi, Kamran;Leili, Ehsan Kazemnejad;Hashemi-Motlagh, Keyvan;Izadi, Amin;Pishgahpour, Mona;Darabipour, Zohre
    • Clinics in Shoulder and Elbow
    • /
    • 제25권3호
    • /
    • pp.224-229
    • /
    • 2022
  • Background: Most acromioclavicular joint (ACJ) injuries are caused by direct trauma to the shoulders, and various methods and techniques are used to treat them; however, none of the options can be considered the gold standard. This study examines the horizontal stability of the ACJ after a complete dislocation was repaired using one of two Ethibond suture techniques, the loop technique and the two holes in the clavicle technique. Methods: In this single-blind, randomized clinical trial, 104 patients diagnosed with complete ACJ dislocation type V were treated using Ethibond sutures with either the loop technique or the two holes in the clavicle technique. Horizontal changes in the ACJ were radiographically assessed in the lateral axial view, and shoulder function was evaluated by the Constant (CS) and Taft (TS) scores at intervals of 3, 6, and 12 months after surgery. Results: The horizontal stability of the ACJ was better with the two-hole technique than the loop technique at all measurement times. CS and TS changes showed a significant upward trend over time with both techniques. The mean CS and TS at the final visit were 95.2 and 11.6 with the loop technique and 94.0 and 11.9 with the two-hole technique, respectively. The incidence of superficial infections caused by the subcutaneous pins was the same in the two groups. Conclusions: Due to the improved ACJ stability with the two-hole technique, it appears to be a more suitable option than the loop technique for AC joint reduction.

폐결핵 재치료에서 이차항결핵제 복합처방의 효과에 관한 비교 연구 (A Comparative Study of Effect of Secondary Anti-tuberculosis Drugs in the Retreatment of Pulmonary Tuberculosis)

  • 하현철;권은수;최인환;황수희;박승규;송선대
    • Tuberculosis and Respiratory Diseases
    • /
    • 제45권6호
    • /
    • pp.1154-1166
    • /
    • 1998
  • 배 경 : 현재 우리나라에서 사용되어지고있는 여러 가지 재치료 결핵제재 조합의 치료효과를 비교함으로써 결핵 재치료시외 올바른 Regimen을 정립시키고자 실시하였다. 방 법 : 1994년 1월부터 1996년 11월까지 국립마산병원에 입원하였던 재치료 환자로서 2차약제를 처음 처방한 104명을 OFX+PTA+CS+PAS+Aminoglycoside주사제를 사용하는 처방군 48명과 PZA+PTA+CS+PAS+Aminoglycoside주사제를 사용하는 처방군 35명 그리고 PZA+OFX+PTA+PAS+Aminoglycoside주사제를 사용하는 처방군 21명으로 분류하여 일반적인 임상 특성 및 치료효과를 연구하였다. 결 과 : 연령분포는 전체적으로는 50세 이상이 36례(34.6%)로 가장 많았고 평균연령은 42.6세였다. 성별은 남자가 81례(77.9%)로 많았다. 동반질환이 있는 경우는 31례(29.8%)였고, 합병증이 있는 경우는 18례(17.3%), 가족력이 있는 경우는 29례(27.9%)로 나타났다. 초치료처방은 HERZ(S or K) 48례 (46.2%), HER(S or K) 41례(39.4%), 기타 15례(14.4%)의 순 이었으며, 입원전 항결핵 치료에서 규칙적으로 치료한 경우가 49례(47.1%)로 나타났다. 약제 내성검사결과 INH와 RFP 동시에 내성이 있는 경우가 68례 (65.4%)로 가장 많았고 RFP에 내성이 있는 경우는 12례(11.5%), INH에 내성이 있는 경우는 3례(2.9%)이었으며, 모든 약제에 감수성이 있는 경우도 3례(2.9%)이었다. 입원시 호소한 증상은 전체적으로 기침이 93례(89.4%)로 가장 많았고, 객담 72례(69.2%), 호흡곤란 39례(37.5%), 체중감소 35례(33.7%), 혈담 16례(15.4%)의 순 이었으며, 증상이 없는 경우도 1례(0.96%)있었다. 입원시 병변의 범위에 따른 분류는 전체적으로 중증이 73례(70.2%)로 가장 많았고 중등증 28례(26.9%), 경증 3례(2.9%)의 순 이었다. 약제에 대한 부작용용 위장장애 31례(29.8%), 관절통 22례(21.2%), 피부질환 12례(11.5%) 등의 순이었다. 객담도말검사상 균이 음전화된 경우는 89례(85.6%)로 Group I이 42례(87.5%), Group II가 28례(80.0%), Group III가 19례(90.5%)였고, 평균 균음전 기간은 4.0개월로 Group I이 4.0개월, Group II가 4.6개월, Group III가 3.0개월이었다. 결 론 : 재치료 병합치료에서 OFX는 PZA를 사용하지 못하는 환자에게 투여하여 PZA를 사용할 때와 유사한 결과를 얻었으며, CS를 사용할 수 없는 환자에게 OFX와 PZA를 복합 처방함으로써 좋은 결과를 얻을 수 있을 것으로 생각된다.

  • PDF