• Title/Summary/Keyword: CS

Search Result 5,345, Processing Time 0.028 seconds

Comparative and Feasibility Evaluation of Detection Ability of Relative Dosimeters using CsPbI2Br and CsPbIBr2 Materials in Brachytherapy QA (근접방사선치료 QA에서 CsPbI2Br과 CsPbIBr2를 이용한 상대 선량계들의 검출 능력 비교 및 적용가능성 평가)

  • Seung-Woo Yang;Sung-Kwang Park
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.433-440
    • /
    • 2023
  • High dose rate brachytherapy is a cancer treatment that intensively irradiates radiation to tumors by inserting isotopes with high dose rates into the body. For such a treatment, it is necessary to deliver an accurate dose to the tumor tissue through an accurate treatment plan while delivering only a minimum dose to the normal tissue. Therefore, it is very important to check the location accuracy of the source through accurate Quality Assurance (QA) in clinical practice. However, since the source position is determined using a ruler, automatic radiographer, video monitor, etc. in clinical practice, it yields inaccurate results. In this study, a semiconductor dosimeter using CsPbI2Br and CsPbIBr2 was fabricated. And, in order to analyze whether it is more suitable for the relative QA dosimeter for brachytherapy device among the two materials, the radiation detection ability of each was compared and evaluated. In order to evaluate the radiation detection ability in brachytherapy, the reproducibility and linearity of the two materials were evaluated in 192IR. In the reproducibility evaluation, CsPbI2Br presented a Relative Standard Deviatio(RSD) of 0.98% and CsPbIBr2 presented an RSD of 3.45%. In the linearity evaluation, the coefficient of determination (R2) of CsPbI2Br was presented as 0.9998, and the R2 of CsPbIBr2 was presented as 0.9994. As a result of the evaluation, it was found that CsPbI2Br was more stable in radiation detection while satisfying the evaluation criteria in the dosimeter manufactured in this experiment. Therefore, CsPbI2Br material is suitable for application as a relative dosimeter for radiation detection in brachytherapy devices.

Rate of Transformation and Normal Range about Cardiac Size and Cardiothoracic Ratio According to Patient Position and Age at Chest Radiography of Korean Adult Man (한국인 성인 남성의 흉부 방사선영상에서 자세와 연령에 따른 심장 크기 및 심흉비의 정상 범위와 변환율)

  • Joo, Young-Cheol;Lim, Cheong-Hwan;Kim, Yun-Min;Jung, Hong-Ryang;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.179-186
    • /
    • 2017
  • Purpose of this study is present the normal range of cardiac size and cardiothoracic ratio according to patient position(chest PA and AP) and age of Korean adult male on digital chest X - ray, And to propose a mutually compatible conversion rate. 1,024 males were eligible for this study, among 1,300 normal chest patients who underwent chest PA and low-dose CT examinations on the same day at the 'S' Hospital Health Examination Center in Seoul From January to December 2014. CS and CTR were measured by Danzer (1919). The mean difference between CS and CTR was statistically significant (p<0.01) in Chest PA (CS 135.48 mm, CTR 43.99%) and Chest AP image (CS 155.96 mm, CTR 51.75%). There was no statistically significant difference between left and right heart in chest PA and AP images (p>0.05). CS showed statistically significant difference between Chest PA (p>0. 05) and Chest AP (p<0.05). The thorax size and CTR were statistically significant (p<0.01) in both age and chest PA and AP. Result of this study, On Chest AP image CS was magnified 15%, CTR was magnified 17% compare with Chest PA image. CS and CTR were about 10% difference by changing posture at all ages.

The Distribution of $^{137}Cs,\;^{90}Sr$ and PU isotopes in the Coastal Sediment of Korea (한국 연안 퇴적물에서 $^{137}Cs,\;^{90}Sr$ 및 PU 동위원소의 분포)

  • Choi, Seok-Won;Jin, Hyun-Gook;Kim, Cheol-Su;Row, Jung-Whan;Kim, Chang-Kyu;Rho, Byung-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.2
    • /
    • pp.101-110
    • /
    • 2002
  • The concentrations and activity ratios of $^{137}Cs,\;^{90}Sr\;^{238}Pu$ and $^{239-240}Pu$ in sediment($0sim}20\;$cm) at 15 coastal stations of Korea were determined. The mean concentrations of $^{137}Cs,\;^{90}Sr\;^{238}Pu$ and $^{239-240}Pu$ are $2.24{\pm0.79\;Bq{\cdot}kg^{-1}-dry,\;0.20{\pm}0.04 Bq{\cdot}kg^{-1}-dry,\;0.009{\pm}0.005\;Bq{\cdot}kg^{-1}-dry}$ and $0.27{\pm}0.17\;Bq{\cdot}kg^{-1}-dry$, respectively. The mean activity ratios of $^{137}Cs,\;^{90}Sr$, $^{239-240}Pu/^{137}Cs$ and $^{238}Pu/^{229-240}Pu$ and atomic ratio of $^{240}Pu/^{239}Pu$ are $11.2{\pm}2.9,\;0.123{\pm}0.053$ and $0.033{\pm}0.017$ and $0.218{\pm}0.036$, respectively. The concentrations and activity ratios in sediment samples are similar to those reported from neighbouring country in the northern hemisphere. The correlation coefficient of $^{137}Cs$ and $^{239-240}Pu$ is 0.80. The correlation coefficient of $^{137}Cs$ and soil organic matter(SOM), and $^{239-240}Pu$ and clay content are 0.69 and 0.67, respectively.

Study on th growth of nonlinear optical crystal $CsLiB_{6}O_{10}$ (비선형 광학 결정 $CsLiB_{6}O_{10}$ 육성에 관한 기초 연구)

  • 김호건;김명섭
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.6 no.2
    • /
    • pp.166-176
    • /
    • 1996
  • The fundamental conditions for growing $CsLiB_{6}O_{10}$ crystal, new nonlinear optical material, were investigated. Stoichiometirc mixture of $CsLiB_{6}O_{10}$ composition resulted in the crystal of the same composition in the process of heating at the temperature above $600^{\circ}C$. No phase transition was observed in the $CsLiB_{6}O_{10}$ crystal in the temperature range of $600^{\circ}C~800^{\circ}C$, and $CsLiB_{6}O_{10}$ crystal melted congruently at $850^{\circ}C$. When the melt of this composition was cooled at rates of $1~150^{\circ}C/hr$, glass state ingot was formed regardless of cooling rates. However, $CsLiB_{6}O_{10}$ crystals were formed directly from the melt at any cooling rate in the presence of $CsLiB_{6}O_{10}$ seed crystal in the melt. Transparent $CsLiB_{6}O_{10}$ single crystal was grown from the melt using the seed crystal at the growing rate of 0.06 mm/hr in the furnace having the temperature gradient of $100^{\circ}C/cm$. Analysis of the single crystal showed that the crystal belonged to the noncentrosymmetric tetragonal space group 142d and unit cell dimensions were $a=10.467(1)\;{\AA},\;c=8.972(1)\;{\AA}\;and\;V=983.0(2)\;{\AA}^3$. Optical absorption edge of the crystal was observed at 180mm and the crystal showed a good optical transparency (70% transmittance, sample thickness 0.5 mm) in the wide wavelength range above 300 nm.

  • PDF

Study on Oxidation or Reduction Behavior of Cs-Te-O System with Gas Conditions of Voloxidation Process (휘발산화 공정 조건에 따른 Cs-Te-O 시스템의 산화 환원 거동 연구)

  • Park, Byung Heung
    • Korean Chemical Engineering Research
    • /
    • v.51 no.6
    • /
    • pp.700-708
    • /
    • 2013
  • Pyroprocessing has been developed for the purpose of resolving the current spent nuclear fuel management issue and enhancing the recycle of valuable resources. Pyroprocessing has been developed with the dry technologies which are performed under high temperature conditions excluding any aqueous processes. Pyro-processes which are based on the electrochemical principles require pretreatment processes and a voloxidation process is considered as a pretreatment step for an electrolytic reduction process. Various kinds of gas conditions are applicable to the voloxidation process and the understanding of Cs behavior during the process is of importance for the analyses of waste characteristics and heat load on the overall pyroprocessing. In this study, the changes of chemical compounds with the gas conditions were calculated by analyzing gas-solid reaction behavior based on the chemical equilibria on a Cs-Te-O system. $Cs_2TeO_3$ and $Cs_2TeO_4$ were selected after a Tpp diagram analysis and it was confirmed that they are relatively stable under oxidizing atmospheres while it was shown that Cs and Te would be removed by volatilization under reducing atmosphere at a high temperature. This work provided basic data for predicting Cs behavior during the voloxidation process at which compounds are chemically distributed as the first stage in the pyroprocessing and it is expected that the results would be used for setting up material balances and related purposes.

Vertical distirbution of $^{137}Cs\;and\;^{90}Sr$ activities in the soils of Korea (토양 중 $^{137}Cs$$^{90}Sr$의 깊이별 분포특성)

  • Cha, H.J.;Park, D.;Park, H.;Kang, M.J.;Lee, W.;Choi, G.S.;Cho, Y.H.;Chung, K.H.;Lee, H.P.;Shin, H.S.;Lee, C.W.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.3
    • /
    • pp.197-204
    • /
    • 2004
  • Vertical distributions of $^{137}Cs\;and\;^{90}Sr$ activities are studied for the soils of six areas, Korea (Gori, Yeonggwang, Uljin, Weolseong, Goseong and Jeju). The soils from 6 areas are at geographically different locations with the different environmental conditions and parent rook. The activities of $^{137}Cs\;and\;^{90}Sr$ vary N.D.(below detection limit) to 185 Bq/kg and 2.79 - 8.06 Bq/kg, respectively. Activities of $^{137}Cs\;and\;^{90}Sr$ show the highest value at the surface soil and decrease with depth. $^{137}Cs$ activities at the top surface soils are positively correlated with annual precipitation and organic carbon content with little relationship with mean grain size and the clay content. The highest $^{137}Cs$activities are found at the Jeju site, followed by the Goseong site of which soils have much different parent rock and textural properties. Though the activities of $^{137}Cs\;and\;^{90}Sr$ on the basis of dry weight are higher in Jeju soils than in Goseong soils, their inventories are similar in both soils due to their textural differences.

Evaluation of Image Quality for Compressed SENSE(CS) Method in Cerebrovascular MRI: Comparison with SENSE Method (뇌혈관자기공영영상에서 Compressed SENSE(CS) 기법에 대한 영상의 질 평가: SENSE 기법과 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.999-1005
    • /
    • 2021
  • The object of this research is CS, which increases resolution while shortening inspection time, is applied to MRA to compare the quality of images for SENSE and CS techniques and to evaluate SNR and CNR to find out the optimal techniques and to provide them as clinical basic data based on this information. Data were analyzed on 32 patients who performed TOF MRA tests at a university hospital in Chung cheong-do (15 males, 17 females), ICA stenosis:10, M1 Aneurysm:10, and average age 53 ± 4.15). In the inspection, the inspection equipment was Ingenia CX 3.0T, Archieva 3.0T, and 32 channel head coil and 3D gradient echo as a method for equipment data. SNR and CNR of each image were measured by quantitative analysis, and the quality of the image was evaluated by dividing the observer's observation into 5 grades for qualitative evaluation. Imaging evaluation is described as being significant when the p-value is 0.05 or less when the paired T-test and Wilcoxon test are performed. Quantitative analysis of SNR and CNR in TOF MRA images Compared to the SENSE method, the CS method is a method measurement method (p <0.05). As an observer's evaluation, the sharpness of blood vessels: CS (4.45 ± 0.41), overall image quality: CS (4.77 ± 0.18), background suppression of images: CS (4.57 ± 0.18) all resulted in high CS technique (p = 0.000). In conclusion, the Compressed SENSE TOF MRA technique shows superior results when comparing and evaluating the SENSE and Compressed SENSE techniques in increased flow rate magnetic resonance angiography. The results are thought to be the clinical basis material in the 3D TOF MRA examination for brain disease.

Reaction of Dehydrated Ag$_2$Ca$_5$-A with Cesium. Crystal Structures of Fully Dehydrated Ag$_2$Ca$_5$-A and Ag$_2$Cs$_{10}$-A

  • Kim, Yang;Song, Seong-Hwan;Park, Jong-Yul;Kim, Un-Sik
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.3
    • /
    • pp.243-247
    • /
    • 1989
  • Two crystal structures of dehydrated $Ag^+\;and\;Ca^{2+}$ exchanged zeolite A, $Ag_2Ca_$5-A, reacting with 0.01 Torr of Cs vapor at $200^{\circ}C$ for 2 hours and 0.1 Torr of Cs vapor at $250^{\circ}C$ for 48 hours, respectively, have been determined by single crystal X-ray diffraction techniques. Their structures were solved and refined in the cubic space group Pm3m at $21(1)^{\circ}C$. The stoichiometry of first crystal was $Ag_2Ca_5$-A (a = 12.294(1)${\AA}$), indicating that Cs vapor did not react with cations in zeolite A and that of second crystal was $Ag_2Cs_{10}$-A (a = 12.166(1)${\AA}$), indicating that all $Ca^{2+}$ ions were reduced by Cs vapor and replaced by $Cs^+$ ions. Full-matrix least-squares refinements of $Ag_2Ca_5-A\;and\;Ag_2Cs_{10}$-A has converged to the final error indices, $R_1\;=\;0.041\;and\;R_2$ = 0.048 with 227 reflections, and $R_1\;=\;0.117\;an\;n\;fdd\;R_2$ = 0.120 with 167 reflections, respectively, for which I > $3{\sigma}$(I). In the structure of $Ag_2Ca_5$-A, both $Ag^+$ ions and $Ca^{2+}$ ions lie on two crystal symmetrically independent threefold axis sites on the 6-rings; $2\;Ag^+$ ions are recessed 0.33 ${\;AA}$ from the (111) planes of three O(3) oxygens and 5 $Ca^{2+}$ ions lie on the nearly center of each 6-oxygen planes. In the structure of $Ag_2Cs_{10}-A,\;Cs^+$ ions lie on the 5 different crystallographic sites. 3 $Cs^+$ ions lie at the centers of the 8-rings at sites of D4h symmetry. 6 $Cs^+$ ions lie on the threefold axes of unit cell: $4\;Cs^+$ ions are found deep in the large cavity and 2 $Cs^+$ ions are found in the sodalite cavity. One $Cs^+$ ion is found in the large cavity near a 4-ring.

Differential Effects between Cigarette Total Particulate Matter and Cigarette Smoke Extract on Blood and Blood Vessel

  • Park, Jung-Min;Chang, Kyung-Hwa;Park, Kwang-Hoon;Choi, Seong-Jin;Lee, Kyuhong;Lee, Jin-Yong;Satoh, Masahiko;Song, Seong-Yu;Lee, Moo-Yeol
    • Toxicological Research
    • /
    • v.32 no.4
    • /
    • pp.353-358
    • /
    • 2016
  • The generation and collection of cigarette smoke (CS) is a prerequisite for any toxicology study on smoking, especially an in vitro CS exposure study. In this study, the effects on blood and vascular function were tested with two widely used CS preparations to compare the biological effects of CS with respect to the CS preparation used. CS was prepared in the form of total particulate matter (TPM), which is CS trapped in a Cambridge filter pad, and cigarette smoke extract (CSE), which is CS trapped in phosphate-buffered saline. TPM potentiated platelet reactivity to thrombin and thus increased aggregation at a concentration of $25{\sim}100{\mu}g/mL$, whereas 2.5~10% CSE decreased platelet aggregation by thrombin. Both TPM and CSE inhibited vascular contraction by phenylephrine at $50{\sim}100{\mu}g/mL$ and 10%, respectively. TPM inhibited acetylcholine-induced vasorelaxation at $10{\sim}100{\mu}g/mL$, but CSE exhibited a minimal effect on relaxation at the concentration that affects vasoconstriction. Neither TPM nor CSE induced hemolysis of erythrocytes or influenced plasma coagulation, as assessed by prothrombin time (PT) and activated partial thromboplastin time (aPTT). Taken together, CS affects platelet activity and deteriorates vasomotor functions in vitro. However, the effect on blood and blood vessels may vary depending on the CS preparation. Therefore, the results of experiments conducted with CS preparations should be interpreted with caution.

Application of Response Surface Methodology (RSM) on Adsorption of Cs Ion in Aqueous Solution with Zeolite X Synthesized from Coal Fly Ash (석탄비산재로 합성한 제올라이트 X에 의한 수중의 Cs 이온 흡착에 반응표면분석법 적용)

  • Lee, Chang-Han;Lee, Min-Gyu
    • Clean Technology
    • /
    • v.23 no.4
    • /
    • pp.413-420
    • /
    • 2017
  • The batch experiments and response surface methodology (RSM) have been applied to the investigation of the Cs adsorption with zeolite X synthesized using coal fly ash generated from the thermal power plant. Regression equation formulated for Cs adsorption was represented as a function of response variables. The model was highly relevant because the decision coefficient ($r^2$) was 0.9630. It was confirmed from the statistical results that the removal efficiency of Cs was affected by the order of experimental factors as pH > Cs concentration > temperature. The adsorption kinetics were more accurately represented by a pseudo second-order model. The maximum adsorption capacity calculated from the Langmuir isotherm model was $151.52mg\;g^{-1}$ at 293 K. Also, according to the thermodynamic parameters calculated from Vant Hoff equation, it could be confirmed that the adsorption reaction was an endothermic reaction and a spontaneous process.