• 제목/요약/키워드: CRT inspection

검색결과 10건 처리시간 0.022초

CRT 판넬의 첵 불량 검출을 위한 새로운 조명 시스템 (A New Lighting System for the Inspection of Check Defect of CRT Panel)

  • 차준혁;권인소;하종은
    • 제어로봇시스템학회논문지
    • /
    • 제10권6호
    • /
    • pp.487-493
    • /
    • 2004
  • In this Paper, we propose a lighting system for the stable detection of check defects of the CRT panel through the analysis of the lighting interaction between the lighting unit and the CRT panel. The check defect is very difficult to detect reliably because of its high sensitivity according to the direction of incident light. At first, we model the physical shape of check defects using SEM image. And then we apply physics based illumination model to investigate the optical characteristics of the check defect. Finally, we propose a lighting system for the stable detection of check defect. Experimental results show the feasibility of the proposed lighting system for check inspection.

폐 브라운관(CRT) 유리의 잔골재 대체가 모르타르 시험체의 감마선 차폐에 미치는 영향 (Effect of Replacing Fine Aggregate by Cathode-Ray Tube(CRT) Waste Glass on Gamma-ray Shielding Properties of Cement Mortar Specimen)

  • 최윤석;이선민;김태상;김일순;양은익
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권7호
    • /
    • pp.172-180
    • /
    • 2019
  • 이 연구에서는 CRT 폐유리의 잔골재 대체율과 재료 물성(조성)을 달리한 모르타르의 미세구조와 감마선 차폐 효율을 평가하였다. 실험 결과에 따르면 CRT 폐유리의 잔골재 대체율이 증가할수록 50nm 크기 이하와 400nm 크기 이상의 공극 볼륨이 증가하였으며, 선헝감쇠계수는 상승하고 반가층은 작아지는 결과를 나타냈다. 또한, CRT 폐유리의 대체했을 때 강도는 감소하였으나 혼화재를 치환하여 OPC 이상의 강도값을 확보할 수 있었다.

CRT 모니터의 감성품질 정량화를 위한 심물리학적 접근: White Uniformity 품질 평가 (A Psychophysical Approach to evaluating the perceived image quality of CRT: White Uniformity Quality)

  • 이욱기;김성환;이선규;이광희;김상수
    • 대한인간공학회지
    • /
    • 제20권2호
    • /
    • pp.59-70
    • /
    • 2001
  • White uniformity is one of the important inspection factors determining the image quality of CRT screen. In the full white pattern, white uniformity means the degree of uniform distribution of white color across the whole screen. To elicit the sensitivity factors affecting the decision of the white uniformity quality, experiments in which participants were confronted with 6 evaluation points embedded in 3 measurement groups on a CRT screen were conducted to gather the psychophysical data that are the level of white uniformity subjects perceived and CA100 produced. These data were used to develop a modified CIE1976 equation for calculating white uniformity. Performance comparison between the original CIE1976 equation and the modified equation was conducted in terms of accuracy test and magnitude estimation. It was concluded the modified equation is more sensitive in the change of white uniformity, compared to the original CIE1976 equation.

  • PDF

폐 브라운관(CRT) 유리를 잔골재로 대체한 모르타르 시험체의 기초 물성 및 방사선 차폐 특성 (Fundamental Properties and Radioactivity Shielding Characteristics of Mortar Specimen Utilizing CRT Waste Glass as Fine Aggregate)

  • 최윤석;김일순;최소영;양은익
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권1호
    • /
    • pp.163-170
    • /
    • 2019
  • 최근 들어, 첨단산업의 발전으로 다양한 종류의 산업폐기물이 빠르게 발생하고 있다. 특히, 산업폐기물 중 중금속을 함유한 고밀도의 폐 브라운관 유리는 재처리 비용과 환경오염 문제로 인해 전량 매립 처분되고 있다. 따라서 이러한 폐자원을 재활용하기 위한 기초 연구가 필요한 실정이다. 이에 본 연구에서는 중금속이 함유된 CRT 폐유리를 잔골재로 대체한 모르타르 시험체의 기초 물성과 방사선 차폐 성능을 분석하여 차폐 재료로의 활용성을 평가하였다. 연구 결과에 따르면 중금속을 함유한 CRT 폐유리를 잔골재로 대체한 시험체의 겉보기 밀도가 상승하였으며, 압축강도와 휨강도는 저하되는 현상을 나타냈다. 또한, 납 성분이 다량 함유된 폐유리 대체 시험체는 일반 모르타르 시험체보다 저에너지의 차폐 성능이 상승하는 효과를 보였으며, $122KeV{\cdot}^{57}Co$ 방사선원에 대해서는 일반 모르타르 시험체보다 2.5배 높은 선형감쇠계수를 나타냈다.

전자부품 검사에서 대용특성을 이용한 사례연구 (A Case Study on Electronic Part Inspection Based on Screening Variables)

  • 이종설;윤원영
    • 품질경영학회지
    • /
    • 제29권3호
    • /
    • pp.124-137
    • /
    • 2001
  • In general, it is very efficient and effective to use screening variables that are correlated with the performance variable in case that measuring the performance variable is impossible (destructive) or expensive. The general methodology for searching surrogate variables is regression analysis. This paper considers the inspection problem in CRT (Cathode Ray Tube) production line, in which the performance variable (dependent variable) is binary type and screening variables are continuous. The general regression with dummy variable, discriminant analysis and binary logistic regression are considered. The cost model is also formulated to determine economically inspection procedure with screening variables.

  • PDF

브라운관의 화상계측 자동화 시스템 개발 (Development of Automated Display Image Characteristic Inspection System of Braun Tube(CRT))

  • 유우식;장성호;이도경
    • 산업경영시스템학회지
    • /
    • 제18권35호
    • /
    • pp.1-8
    • /
    • 1995
  • Automatic inspection system software for display image characteristic of CRT is developed. There are two major contributions of this software development. One is that the data from measuring equipments which was usually collected manually is automatically collected through RS-232C port and is saved in computer, then, trend analysis graph and final reports are generated. The other is that evauation of characteristic of electron gun was automatically processed by CCD camera and image processing technique. The system is developed under MS-Windows environment utilizing Borland C++4.0 Compiler and DT 3852-8 image processor board. This system can save the time and man power to measure and to anayze the image characteristics relative to current method.

  • PDF

비젼프로브를 이용한 CRT 전자총의 자동치수 검사 (Automatic Inspection of Assembly Tolerances of Cathod Ray Electron Guns by Vision Probe)

  • Park, H.G.;Park, M.C.;Kim, S.W.
    • 한국정밀공학회지
    • /
    • 제14권10호
    • /
    • pp.28-34
    • /
    • 1997
  • This paper describes an automatic measurement method for the in-line inspection of assembly tolerances of cathod ray electron guns. The method uses an optical microscope with a CCD camera as a probe. An automatic gap recognition algorthm with digital image processing and a new software autofocus algorithm based on using an optimal edge detector have been developed to improve the measuring accuracy. An inspection system has been proposed and practically implemented for in-line inspection to a real factory automation line. The inspection system consists of a gap inspection part and an eyelet. Total time consumed for inspecting all measuring items is about 10 seconds and the repeatability is below .+-. 5 .mu. m

  • PDF

착자 자동화 시스템 및 통계분석 툴 개발 (Development of Statistical Analyzing Tool and System of Automatic Magnetizer)

  • 이천희;하기종
    • 한국정보처리학회논문지
    • /
    • 제3권4호
    • /
    • pp.1014-1025
    • /
    • 1996
  • 현재 CRT(Cathode-Ray Tube)의 마그네트(Magnet) 생산업체에서 색상제어에 사용 構殷있는 착자기 및 착자검사기는 수동으로 작업 시간이 오래 걸리고 오동작 시킬 우려가 있다. 본 연구에서는 착자와 검사 공정까지를 한 시스템으로 묶은 시스템 장치를 개발하여 전공정을 자동화시켰다. 따라서 본 시스템은 매회 작업 상태를 검사하고 품질의 산포를 정확하게 분석하여 착자 및 착자 상태 검사의 신뢰도를 향상시켜 불량을 없애도록 하였다.

  • PDF

지배주파수도를 이용한 미소 표면 결함 추출을 위한 영상 처리 알고리듬 (A visual inspection algorithm for detecting infinitesimal surface defects by using dominant frequency map)

  • 김상원;권인소
    • 제어로봇시스템학회논문지
    • /
    • 제2권1호
    • /
    • pp.26-34
    • /
    • 1996
  • One of the challenging tasks in visual inspection using CCD camera is to identify surface defects in an image with complex textured backgeound. In microscopic view, the surface of real objects shows regular or random textured patterns. In this paper, we present a visual inspection algorithm to extract abnormal surface defects in an image with textured background. The algorithm uses the space and frequency information at the same time by introducing the Dominant Frequency Map(DFM) which can describe the frequency characteristics of every small local region of an input image. We demonstrate the feasibility and effectiveness of the method through a series of real experiments for a 14" TV CRT mold. The method successfully identifies a variety of infinitesimal defects, whose size is larger than $50\mu\textrm{m}$, of the mold. The experimental results show that the DFM based method is less sensitive to the environmental changes, such as illumination and defocusing, than conventional vision techniques.ques.

  • PDF

소프트 카피 초음파 이미지를 보기 위한 최적의 주변광 조도 연구 (Optimal Ambient Illumination Study for Soft-Copy Ultrasound Images)

  • 안현;이효영
    • 한국방사선학회논문지
    • /
    • 제13권2호
    • /
    • pp.209-216
    • /
    • 2019
  • 본 논문은 초음파 검사 및 판독에 사용되는 CRT, LCD 모니터에서 영상검사와 판독 시 적절한 시각화에 대한 최적의 주변 조도 수준을 제안하고자 하였다. 평가자들은 4그룹 20명(Ultra-sonographer 20명(4 groups; ultra-sonographer 1~5 years 5명, ultra-sonographer 6~10 years 5명, ultra-sonographer 11~15 years 5명, ultra-sonographer 16~20 years 5명)을 대상으로 하였으며, 문항수는 32문항이었다. 평가방법은 10, 25, 100 Lux 3가지 주변광 조도에서 초음파 soft copy 영상을 1문항 당 30초간 영상 평가하였으며, 평가 결과를 6점 척도로 1점=Normal (Definitely no lesion), 2점=possibly not a lesion, 3점=probably not a lesion, 4점=possibly a lesion, 5점=probably a lesion, 6점=Definitely a lesion으로 나타내었다. 본 연구에서 주변광에 따른 초음파 영상들에 대한 병변 감지에 사용되는 소프트 카피(soft copy) 영상 판독 ROC분석 결과는 10 Lux에서 높은 민감도, 특이도, 곡선하면적 결과를 나타내었다. 주변광 조도로 10 Lux를 이용한다면 초음파(ultrasound) 소프트 카피(soft copy) 영상의 병변 탐지에 있어 최적의 효과를 얻을 수 있음을 알 수 있었다. 추후 연구 자료를 기초로 하여 초음파 영상 검사실 및 판독실의 주변광 조명밝기를 설계하면서 기초자료로 제시될 것으로 생각한다.