• Title/Summary/Keyword: CREST

Search Result 894, Processing Time 0.027 seconds

Healing Effects of Demineralized Freeze - Dried Bone Allograft and Deproteinized Bovine Bone Mineral on Periodontal Fenestration Defect in Rats (탈회 동결 건조골과 탈단백 우골의 백서 치조골 천공결손에 대한 치유 효과)

  • Shin, Joong-Ho;Kwon, Young-Hyuk;Park, Jun-Bong;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.1
    • /
    • pp.73-91
    • /
    • 2001
  • The present study was performed to compare effects of demineralized freeze-dried bone allograft(DFDBA) with deproteinized bovine bone mineral(DBBM) on periodontal fenestration defect in rats. Twelve adult male rats weighing 500 to 540 grams were used in this study. Periodontal fenestration defects were surgically created with tapered fissure bur(${\Phi}1mm$) at the left side of buccal surface of the mandible. The defect size was from anterior border of the first molar to anterior of the ascending ramus mesiodistally and from just below the alveolar crest to apically 1.5-2mm area apicocoronally with 2mm in depth. Rats were divided into control group, test group I and II. Four defects were assigned to the test group I grafted with DBBM and other 4 defects were assigned to the test group II grafted with DFDBA. The rest of defects were the negative control group. At 10 days and 35 days after surgery, 12 rats were sacrificed through intracardiac perfusion and specimens were obtained prepared with Hematoxylin-Eosin stain for light microscopic evaluation. The results of this study were as follows : 1. In the control group, new bone, osteoid, dense connective tissue were observed in the defects at 10 days. new bone formation was not found but loose connective tissue was formed in the defect and fibrous encapsulation of graft materials was shown in two test groups at 10 days. 2. In all groups, new bone formation was shown in the defect at 35 days. And in the control group, bone formation increased at 35 days than at 10 days. 3. In the test group I and II at 35 days, graft materials were combined with new bone and joined host bone. There was very close contact between new bone, graft materials, and host bone with no gaps. 4. In the test group I and II, new bone formation was similar to that in the control group but not exeeded. In conclusion, in the test group I new bone formation was similar to that in the test group II at 35 days, but there was infiltration of inflammatory cells at 10 days. DFDBA and DBBM were considered as the biocompatible graft materials and effective in the regeneration of new bone.

  • PDF

Geological and Geophysical Characteristics of the New Hebrides Basin (뉴헤브리디스 해분의 지질.지구물리학적 특징에 관한 연구)

  • Park, Chung-Hwa
    • Journal of the Korean earth science society
    • /
    • v.18 no.6
    • /
    • pp.559-564
    • /
    • 1997
  • The New Hebrides Basin is an inactive non back-arc basin located at the convergent boundary of the Pacific and Info-Australian plates. This basin was formed from 46 Ma to 60 Ma. The basin has two spreading episodes with rates of 34 mm/a for 42 to 47 Ma and 17 mm/a for 47 to 60 Ma. The sediments covered in the basin has uniform thickness of 0.65 sec. The age-depth correlation curve of the New Hebrides Basin can be represented by the following equation: $Depth(m)=2689+312\sqrt{Age}(Ma)$ The coefficient of 312 in this equation is close to that for major oceans, 350. This suggests that the cooling processes of the lithospheres in the New Hebrides Basin and major oceans are similar to each other. Free-air gravity anomalies of the basin varying from -22.3 mgal to +59.0 mgal. The mean value is +30.2 mgal higher than those of the normal oceans. Moderately large free-air gravity anomalies in the New Hebrides Basin are presumably owing to its location on a marginal swell along the New Hebrides Trench. It is generally observed that the ocean floor is very gently uplifted in a zone about 200 km oceanward of the trench axis. Positive free-air gravity anomalies amounting to $50{\sim}60$ mgal are usually observed on the crest of the swell. This topography is presumably by bending of the oceanic lithosphere so as to dynamically maintain nonisostatic states for some duration.

  • PDF

Finite Element Stress Analysis of Implant Prosthesis according to Position and Direction of Load (하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소법적 응력분석)

  • Bae, Sook-Jin;Chung, Chae-Heon;Jeong, Seung-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.4
    • /
    • pp.257-268
    • /
    • 2003
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis according to position and direction of load, under vertical and inclined loading using FEA analysis. The finite element model was designed according to standard fixture (4.1mm restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric usp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant in both vertical and oblique loading but stresses in the cancellous bone were low in both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. 4. The relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 5. The magnitude of the stress in the supporting bone, fixture and abutment screw was greater with the outward oblique loading than with the inward oblique loading and was the greatest under loading at the centric cusp in a $30^{\circ}$ outward oblique direction. Conclusively, this study provides evidence that bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. But it seems to be more important that how long is the distance from center of rotation of the implant itself to the resultant line of force from occlusal contact(leverage). The goal of improving implants should be to avoid bending of the implant.

Finite Element Stress Analysis of Implant Prosthesis of Internal Connection System According to Position and Direction of Load (임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석)

  • Jang, Jong-Seok;Jeong, Yong-Tae;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 2005
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis of internal connection system(ITI system) according to position and direction of load, under vertical and inclined loading using finite element analysis (FEA). The finite element model of a synOcta implant and a solid abutment with $8^{\circ}$ internal conical joint used by the ITI implant was constructed. The gold crown for mandibular first molar was made on solid abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric cusp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant under both vertical and oblique loading but stresses in the cancellous bone were low under both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. So, the relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 4. In this internal conical joint, vertical and oblique loads were resisted mainly by the implant-abutment joint at the screw level and by the implant collar. Conclusively, It seems to be more important that how long the distance is from center of rotation of the implant itself to the resultant line of force from occlusal contact (leverage). In a morse taper implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. This type of implant-abutment connection can also distribute forces deeper within the implant and shield the retention screw from excessive loading. Lateral forces are transmitted directly to the walls of the implant and the implant abutment mating bevels, providing greater resistance to interface opening.

Efficacy and Safety of Micro Current Tape on Chronic Low Back Pain: One Group Pre-Post Test Design, Multi Center Pilot Study (만성 요통 통증 완화에 대한 미세전류 테이프의 안전성 및 유효성 평가)

  • Park, Hyun-Gun;Kim, Jong-Yeon;Yi, Woon-Sup;Lee, Sin-Ji;Chung, Won-Suk;Kim, Ho-Jun;Lee, Jong-Soo
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.23 no.4
    • /
    • pp.185-194
    • /
    • 2013
  • Objectives The aim of this study was to evaluate the efficacy and safety of micro current taping therapy (MTT) on patients with chronic low back pain (CLBP). Methods We included 50 participants who met the inclusion criteria and 5 participants dropped out during the sessions due to the following reasons: 3 participants were personal reasons, 1 participant was taking medication, 1 participant was fore arm fracture. We attached "I" shaped 40 cm, 2 tapes along the erector muscles of the spine starting from both iliac crest and another "I" shaped 30 cm, 1 tape on the painful site horizontally. This procedure was done 8 times and participants visited a total of 9 times including a final visit for evaluation. We measured visual analog scale (VAS), range of motion (ROM) and schober's test on every visit. Participants completed a questionnaire of oswestry disability index (ODI) and Beck's depression inventory (BDI) on the first and last visits. Results In VAS for pain intensity and bothersomeness, there were significant decreases after 1st, 6th treatments. In range of extension, there was significant increase after 3rd treatment at first. In range of flexion, there was significant increase after 2nd treatment at first. In range of left flexion, there was significant increase after 4th treatment at first. In range of right flexion, there was significant increase after 3rd treatment at first. in schober's test, there was significant increase after 2nd treatment at first. In VAS, ROM, schober's test, BDI, ODI, there were significant improvement after all treatments had done. Conclusions There was a significant effect of MTT on CLBP. And there was no adverse effect.

A PHOTOELASTIC STRESS ANALYSIS IN MANDIBULAR DISTAL - EXTENSION REMOVABLE PARTIAL DENTURES WITH VARIOUSLY DESIGNEO INDIRECT RETAINERS (간접유치장치 설계변화에 따른 하악유리단 국소의치의 광탄성 응력분석)

  • Kang, Seung-Jong;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.183-197
    • /
    • 1990
  • The purpose of this study was to analyse the magnitude and distribution of stresses using a Photoelastic model from and distal - extension removable partial dentures With four designed indirect retainers. The designs of the indirect retainers were as follows : Design No. 1 : Aker's clasp on 1st bicuspid with no indirect retainer. Design No. 2 : Aker's clasp on 1st bicuspid with indirect retainer on canine. Design No. 3 : Extension of the reciprocal arm of Aker's clasp toward incisal rest on canine. Design No. 4 : Connection with the indirect retainer as in No. 2 and extension of reciprocal arm of Aker' s clasp. A photoelastic model was made of the epoxy resin(PL - 1) and hardner(PLH - 1) and coated with plastic cement -1(PC -1) at the lingual surface of the epoxy model and set with chrome - cobalt partial dentures. A unilateral vertical load of 10kg to the right 1st molar and a vertical load of 10kg to the middle portion of the metal bar crossing both the 1st molars of the right and left, were applied. With the use of specially designed jig, fixture; loading device and the reflective circular polariscope, we obtained the following results : 1. When the unilateral vertical load and the vertical load of the middle portion of the metal bar were applied, design No. 2, 3 and 4 exhibited the higher stress concentration at the root apices and their surrounding tissues of the primary and secondary abutment teeth. 2. When the unilateral vertical load applied to design No. 2,3 and 4 the root apices of the primary and secondary abutment teeth and their surrounding tissues and the nonloaded side of edentulous area exhibited and even stress distribution. 3. When the vertical load was applied, the stress concentration fringe in the primary and secondary abutment teeth was in the order of No. 1,4,2 and 3. 4. No.1 and 4 exhibited the higher distrorted stress concentration at the primary teeth and the edentulous area in the nonloaded side. 5. No.2 design reduced the stresses at the apices of the alveoli of the primary abutment teeth bilaterally as well as on the crest of the residual ridge on the nonloaded side. 6. No. 2 design exhibited the most favorable stress distribution.

  • PDF

Comparison of autogenous tooth bone graft and synthetic bone graft materials used for bone resorption around implants after crestal approach sinus lifting: a retrospective study

  • Kim, Young-Kyun;Lee, Junho;Yun, Ji-Young;Yun, Pil-Young;Um, In-Woong
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.5
    • /
    • pp.216-221
    • /
    • 2014
  • Purpose: This retrospective study compares the amount of bone resorption around implants between an autogenous tooth bone graft (AutoBT) and a synthetic bone graft after a bone-added crestally approached sinus lift with simultaneous implant placements. Methods: In all, 37 patients participated in this study. Seventeen patients were grouped as group I and underwent an AutoBT-added sinus lift using the crestal approach. The remaining 20 patients were grouped as group II and underwent synthetic bone grafting. Both groups received the implant placements simultaneously. Of the 37 participating patients, only 22 patients were included in the final results: Eleven patients of group I and 11 patients of group II. Before the surgery, the distance from the alveolar crest to the sinus floor was measured using panoramic radiography. After the surgery, the distance was measured again from the neck of the implant thread to the most superior border of the added graft materials. Then, the amount of sinus lift was calculated by comparing the two panoramic radiographs. After a year, a panoramic radiograph was taken to calculate the resorption of the bone graft material from the radiograph that was taken after the surgery. The significance of the resorption amount between the two types of graft materials was statistically analyzed. Results: The bone height was increased to an average of 4.89 mm in group I and 6.22 mm in group II. The analysis of panoramic radiographs 1 year after the surgery showed an average bone resorption of 0.76 mm and 0.53 mm, respectively. However, the degree of lifting (P=0.460) and the amount of bone-grafted material resorption (P=0.570) showed no statistically significant difference. Conclusions: Based on this limited study, AutoBT can be considered a good alternative bone graft to a synthetic bone graft in a bone-added sinus lift, when extraction is necessary prior to the surgery.

Platelet-rich fibrin along with a modified minimally invasive surgical technique for the treatment of intrabony defects: a randomized clinical trial

  • Ahmad, Nabila;Tewari, Shikha;Narula, Satish Chander;Sharma, Rajinder Kumar;Tanwar, Nishi
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.6
    • /
    • pp.355-365
    • /
    • 2019
  • Purpose: The modified minimally invasive surgical technique (M-MIST) has been successfully employed to achieve periodontal regeneration. Platelet-rich fibrin (PRF) is known to enhance wound healing through the release of growth factors. This study aimed to observe the outcomes of periodontal surgery when M-MIST was used with or without PRF for the treatment of isolated intrabony defects. Methods: This randomized clinical trial was conducted on 36 systemically healthy patients, who had chronic periodontitis associated with a single-site buccal probing pocket depth (PPD) and clinical attachment level of ≥5 mm. Patients were randomly divided into 2 groups: the test group treated with M-MIST and PRF, and the control group treated with M-MIST alone. The primary periodontal parameters analyzed were PPD, relative attachment level (RAL), and relative gingival margin level. The radiographic parameters analyzed were change in alveolar crest position (C-ACP), linear bone growth (LBG), and percentage bone fill (%BF). Patients were followed up to 6 months post-surgery. Results: Intragroup comparisons at 3 and 6 months showed consistently significant improvements in PPD and RAL in both the groups. In intergroup comparisons, the improvement in PPD reduction, gain in RAL, and the level of the gingival margin was similar in both groups at 3 and 6 months of follow-up. Furthermore, an intergroup comparison of radiographic parameters also demonstrated similar improvements in C-ACP, LBG, and %BF at 6 months of follow-up. Conclusions: M-MIST with or without PRF yielded comparable periodontal tissue healing in terms of improvements in periodontal and radiographic parameters. Further investigation is required to confirm the beneficial effects of PRF with M-MIST.

Three-dimensional finite element analysis according to the insertion depth of an immediately loaded implant in the anterior maxilla (상악 전치부 즉시하중 임플란트의 식립 깊이에 따른 삼차원 유한요소 분석)

  • Park, Cheol-Woo;Kim, Sung-Hun;Yeo, In-Sung;Yoon, Hyung-In;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.105-113
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the effects of the insertion depth of an immediately loaded implant on the stress distribution of the surrounding bone and the micromovement of the implant using the three-dimensional finite element analysis. Materials and methods: A total of five bone models were constructed such that the implant platform was positioned at the levels of 0.00 mm, 0.25 mm, 0.50 mm, 0.75 mm, and 1.00 mm depth from the crest of the cortical bone. A frictional coefficient of 0.3 and the insertion torque of 35 Ncm were simulated on the interface between the implant and surrounding bone. A static load of 178 N was applied to the provisional prosthesis with a vertical load in the axial direction and an oblique load at $30^{\circ}$ with respect to the central axis of the implant, then a finite element analysis was performed. Results: The implant insertion depth significantly affected the stress distribution on the surrounding bone. The largest micromovement value of the implant was $39.34{\mu}m$. The oblique load contributed significantly to the stress distribution and micromovement in comparison to the vertical load. Conclusion: Increasing the implant insertion depth was advantageous in dispersing the concentrated stress in the cortical bone and did not significantly affect the micromovement associated with early osseointegration failure.

Development of an Aerodynamic Simulation for Studying Microclimate of Plant Canopy in Greenhouse - (1) Study on Aerodynamic Resistance of Tomato Canopy through Wind Tunnel Experiment - (공기유동해석을 통한 온실내 식물군 미기상 분석기술 개발 - (1) 풍동실험을 통한 토마토 식물군의 공기저항 연구 -)

  • Lee In-Bok;Yun Nam-Kyu;Boulard Thierry;Roy Jean Claude;Lee Sung-Hyoun;Kim Gyoeng-Won;Lee Seung-Kee;Kwon Soon-Hong
    • Journal of Bio-Environment Control
    • /
    • v.15 no.4
    • /
    • pp.289-295
    • /
    • 2006
  • A computational fluid dynamics (CFD) numerical model has been developed to effectively study the ventilation efficiency of multi-span greenhouses with internal crops. As the first step of the study, the internal plants of the CFD model had to be designed as a porous media because of the complexity of its physical shapes. In this paper, the results of the wind tunnel tests were introduced to find the aerodynamic resistance of the plant canopy. The Seogun tomato was used for this study which made significant effects on thermal and mass exchanges with the adjacent air as well as internal airflow resistance. With the main factors of wind speed, static pressure, and density of plant canopy, the aerodynamic resistance factor was statically found. It was finally found to be 0.26 which will be used later as an input data of the CFD model. Moreover, the experimental procedure of how to find the aerodynamic resistance of various plants using, wind tunnel was established through this study.