• 제목/요약/키워드: CREST

검색결과 891건 처리시간 0.022초

복부 방사선검사 자세가 유방선량에 미치는 영향 (Effects of Breast Dose on Plain Abdominal Position)

  • 주영철;김승혁
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권3호
    • /
    • pp.155-159
    • /
    • 2020
  • The purpose of this study is to investigate the effect of posture changes(Anteroposterior projection, Posteroanterior projection) in the plain abdominal examination on breast dose and to examine its clinical usefulness. This study was used a human body phantom and a glass dosimeter. Glass dosimeters were directly inserted from the center and outside of medial and lateral. In this study, the deep dose was measured in the right breast and the surface dose in the left breast. During the abdominal examination, the central X-ray incident point was perpendicularly incident to the image receptor 5 cm above the iliac crest. The exposure parameters were 82 kVp, 320 mA, 50 ms, x-ray field size 14×17 inch The distance between the center X-ray and the detector was fixed at 110 cm, and only the top two AEC chambers were used. As a result of this study, the medial and lateral side doses of the right breast were 535.73±30.68 μGy and 414.46±33.52 μGy for erect AP, and 145.80±18.52 μGy and 148.76±12.92 μGy in erect PA. The superficial breast dose was 754.00±68.36 μGy on the medial side and 674.06±45.58 μGy on the lateral side in the erect AP, 70.66±7.98 μGy on the medial side, and 86.46±15.35 μGy on the lateral side in the erect PA. There was a statistically significant difference in the difference between the mean values of the medial and lateral side doses in the deep and superficial areas of the breast according to the postural change (p <0.01). As a result of this study, If the abdominal radiography was examined in the PA position, the dose reduction effect was 72.78% on the medial side, 64.10% on the lateral side of the deep breast, 90.62% on the medial side, and 87.17% on the lateral side of the superficial breast compared to the AP position.

횡월류형 강변저류지를 포함하는 하천수계에 대한 수리학적 계산모형 (Computational Model for Flow in River Systems Including Storage Pockets with Side Weirs)

  • 전경수;김진수;김원;윤병만
    • 한국수자원학회논문집
    • /
    • 제43권2호
    • /
    • pp.139-151
    • /
    • 2010
  • 횡월류식 강변저류지를 포함하는 하천수계의 흐름 모의를 위한 준2차원 부정류 계산모형을 수립하였다. 수립된 모형은 횡월류 흐름에 대해서는 수량보존에 관한 연속방정식 및 월류형 수위-유량 관계식을, 하도에 대해서는 1차원 St. Venant 방정식을 각각 지배방정식으로 하여 흐름을 모의하는 폐합형 계산모형이다. 수립된 모형을 현재 계획 중인 군남 홍수조절지부터 한강 합류 지점까지의 임진강 구간에 대하여 적용하였다. 횡월류 위어의 유량계수에 대한 민감도 분석 결과, 최대유량 및 수위의 저감효과는 유량계수에 관계없이 거의 일정한 것으로 나타났다. 수계 하류 측에 위치한 강변저류지일수록 배수영향이 커지므로 첨두 홍수위의 감소효과는 줄어드는 것으로 모의되었다. 강변저류지의 홍수저감 효과는 조도계수에 따라 크게 달라지며 횡월류 위어의 정부표고가 높을수록 조도계수에 따른 홍수조절 효과의 불확실성이 커지는 것을 알 수 있었다. 강변저류지의 설계를 위해서는 조도계수의 적절한 추정과정이 선행되어야 함은 물론이고, 추정된 조도계수의 불확실성을 감안하여 횡월류 위어의 정부표고를 결정하기 위한 방법의 개발이 필요할 것으로 판단된다.

Distribution of the lingual foramina in mandibular cortical bone in Koreans

  • Kim, Dae Hyun;Kim, Moon Yong;Kim, Chul-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권6호
    • /
    • pp.263-268
    • /
    • 2013
  • Objectives: The interforminal region, between the mandibular foramen, is known as a relatively safe area that is free of anatomic structures, such as inferior alveolar nerve, submandibular fossa, and lingual side of the mandible is occasionally neglected for its low clinical importance. Even in the case of a severely constricted alveolus, perforation of the lingual cortical bone had been intended. However, anterior extension of the inferior alveolar canal, important anatomic structure, such as concavity of lingual bone, lingual foramina, and lingual canal, has recently been reported through various studies, and untypical bleeding by perforation of the lingual plate on implantation has also been reported. Therefore, in this study, we performed radiographic and statistical analysis on distribution and appearance frequencies of the lingual foramina that causes perforation of the mandibular lingual cortical bone to prevent complications, such as untypical bleeding, during surgical procedure. Materials and Methods: We measured the horizontal length from a midline of the mandible to the lingual foramina, as well as the horizontal length from the alveolar crest to the lingual foramina and from the lingual foramina to the mandibular border by multi-detector computed tomography of 187 patients, who visited Dankook University Dental Hospital for various reasons from January 1, 2008 to August 31, 2012. Results: From a total of 187 human mandibles, 110 (58.8%) mandibles had lingual foramina; 39 (20.9%) had bilateral lingual foramen; 34 (18.2%) had the only left lingual foramen; and 37 (19.8%) had the only right lingual foramen. Conclusion: When there is consistent bleeding during a surgical procedure, clinicians must consider damages on the branches of the sublingual artery, which penetrate the lingual foramina. Also, when there is a lingual foramina larger than 1 mm in diameter on a pre-implantation computed tomography, clinicians must beware of vessel damage. In order to prevent these complications and progress with a safe surgical procedure, a thorough radiographic examination before the surgery is indispensable. Further, clinicians should retract lingual flap definitely to confirm the shape of the lingual bone and existence of the lingual foramina.

파노라마방사선사진에서 하악 구치부의 임플란트 매식부위 평가시 치조정-하악관간 거리의 확대율에 영향을 미치는 요소에 관한 연구 (The Affecting Factor to Magnification Ratio from Alveolar Crest To Inferior Mandibular Canal in Diagnosis of Implant Site of Mandibular Molar Region with Panoramic Radiography)

  • 정재진;최상묵;이용무;구영;정종평;한수부;류인철
    • Journal of Periodontal and Implant Science
    • /
    • 제31권4호
    • /
    • pp.811-822
    • /
    • 2001
  • 최근 임플란트를 원하고, 필요로 하는 환자가 증가하면서 술전의 정확한 진단이 보다 중요해졌고 다양한 진단방법이 소개되고 이용되어져 왔다. 그 중 보편적으로 가장 널리 사용되어지는 방법이 방사선 촬영법이고 그 중에서도 파노라마방사선사진이다. 하지만 파노라마방사선사진의 용이함과 간편성에도 불구하고 그 방법 자체가 가지고 있는 한계점 때문에 CT/MPR(Computer Tomography/Multiplanar Reformatting)이 일부 환자에서는 반드시 필요하다는 주장이 대다수이다. 본 연구의 목적은 하악 구치부에 임플란트 시술을 받은 환자를 대상으로 파노라마방사선사진의 확대율을 알아보고 파노라마방사선사진과 CT/MPR에서 치조정-하악관간 거리가 실제 어느 정도 차이를 보이는지, 그리고 CT/MPR에 대한 파노라마방사선사진의 확대율에 환자의 하악골의 경사도와 하악관의 해부학적 위치가 어떤 영향을 미치는지를 알아보는 것이다. 본 연구는 서울대학 치과병원 치주과를 내원하여 하악구치부에 Dental Implant 시술을 받은 15명의 환자, 32개 부위를 대상으로, 임플란트 시술을 위한 술전 파노라마방사선사진과 CT/MPR, 술후의 파노라마방사선사진, CT/MPR상을 자료로, 임플란트가 식립될 위치에서 치조정에서 하악관의 길이, 하악골의 협설폭경, 하악골의 설측면에서 하악관의 수평길이, 임플란트 매식체의 설측에서 하악관까지의 수평거리를 계측하였고 이 해부학적 계측치들이 CT/MPR에 대한 파노라마방사선사진의 확대율과 어떤 상관관계에 있는지 Pearson's correlation coefficient test를 이용해 살펴보았다. 1. CT/MPR에 대한 파노라마방사선사진의 확대율은 CT/MPR상에서 하악골 단면의 협설폭경(Pearson test에서의 상관관계 분석시, 상관계수 r=-0.604), 임플란트 매식체의 설측에서 하악관까지의 수평거리(r=-0.515), 하악골의 설측면에서 하악관까지의 수평거리(r=-0.640)와 뚜렷한 음적 선형관계가 있었다. 2. CT/MPR에 대한 파노라마방사선사진의 확대율은 CT/MPR상에서 하악골의 장축의 각도와는 뚜렷한 양적 선형관계(Pearson test에서의 상관관계 분석시, 상관계수 r=-0.446)가 있었다. 3. 여러 요소중 CT/MPR에 대한 파노라마방사선사진의 확대율과 가장 유의성있는 연관성을 보이는 것은 CT/MPR상에서 하악골의 설측면에서 하악관까지의 수평거리였다(r=-0.640) 4. CT/MPR에 대한 파노라마방사선사진의 확대율은 일반적으로 생각되어지는 파노라마방사선사진의 확대율 125%보다 큰, 약 135%로 나왔다. 이상의 결과로 볼 때, 하악골의 설측면에서 하악관까지의 수평거리가 CT/MPR에 대한 파노라마방사선사진의 확대율에 가장 영향을 미치는 요소로 추정되며 확대율은 125%보다 높은 것으로 나타났다.

  • PDF

위상이동 형상측정법을 이용한 의치 중합 방법에 따른 적합도 검사 (FITNESS TEST USING THE PHASE-SHIFTING PROFILOMETRY ACCORDING TO THE DENTURE CURING METHODS)

  • 이청희;조광헌;최부병
    • 대한치과보철학회지
    • /
    • 제37권4호
    • /
    • pp.474-493
    • /
    • 1999
  • According to repeated measurements and correction procedures, the accuracy of the phase-shifting profilometry was developed. At first, after 20 final models for maxillary complete denture were duplicated , the mucosa sur-faces of models were measured with the phase-shifting proflometry and each mirror view of these was calibrated. Maxillary casts were divided into 4 groups of 5 casts per each, and wax dentures with 2 sheets of baseplate wax and artificial teeth were made and then cured according to the curing method of each group. Group I ; quick curing with QC-20 acrylic resin Group II ; 9 hour curing with QC-20 acrylic resin Group III ; SR-Ivocap system Group IV ; metal base and quick curing with QC-20 acrylic resin. After curing, polishing, and storing at $37^{\circ}C$ in saline for 30 days, the forms of the impression surface of the dentures were measured with the phase-shifting profilometry. Then, the impression surface form of each denture was placed in the optimal position of com-parison with the mirror view of the same final cast. The amount and direction of distortion of each denture was analyzed and the effects of polishing and storage in each denture were compared, The obtained results were as follows : 1. In Group I, the denture was observed as the appearance distorted in the opposite direction of the mucosa and the postero-lateral part of palatal portion of the denture was observed as the appearance separated from the mucosa. Also, the buccal flanges of the denture were observed as the appearance distorted in the direction of the mucosa. 2. In Group II, the postero-lateral part of palatal portion of the denture was observed as the appearance separated slightly from the mucosa. The bilateral buccal flanges of denture were observed as the appearance distorted severely in the direction of the mucosa. 3. In Group III the bilateral part of the residual ridge crest portions and the buccal flanges of the denture were observed as the appearance distorted in the direction of the mucosa, and specially, the buccal flanges of the maxillary tuberosities were distorted severely. 4. In Group IV, the acrylic resin base of the buccal portion of the denture was observed as the appearance distorted in the opposite direction of the mucosa. 5. The phase-shifting profilometry, done with repeated measurements and correction procedures, was effective in comparing the amount and direction of distortion at every position after the laboratory work and the delivery of maxillary complete denture.

  • PDF

파노라마방사선사진에서 환자의 머리 위치가 하악 수직, 수평 확대율에 미치는 영향: 상하 및 좌우회전 (Effect of head positioning on the vertical and horizontal magnification in panoramic radiographs: rotation along the sagittal and transverse plane)

  • 김용건;변진석;안서영
    • 구강회복응용과학지
    • /
    • 제30권1호
    • /
    • pp.1-8
    • /
    • 2014
  • 목적: 이 연구는 파노라마방사선사진 촬영 시 환자의 머리 위치가 상방, 하방, 좌측 및 우측으로 회전됨에 따른 수평 및 수직 확대율의 변화를 비교 평가하는 것이었다. 연구 재료 및 방법: 직경 4 mm인 금속구 5개를 건조 두개골의 하악 전치부(2개)와 우측 대구치부(3개)의 치조골 상방에 위치시켰다. 상하 및 좌우 회전량을 조절할 수 있는 두개골 고정장치에 건조 두개골을 고정시킨 후, 기준 위치와 회전된 위치에서 파노라마방사선사진을 쵤영하였다. 결과: 기준 위치에서 평균 수평 확대율은 $1.22{\pm}0.01-1.44{\pm}0.01$이었고, 평균 수직 확대율은 $1.29{\pm}0.00-1.35{\pm}0.02$였다. 전치부와 구치부 비교시 수평 확대율은 전치부에서 $1.24{\pm}0.02-1.31{\pm}0.03$, 구치부에서 $1.40{\pm}0.03-1.33{\pm}0.02$로 유의한 차이가 있었고(P < 0.05), 수직 확대율은 차이가 없었다. 위치 변화에 따른 수평 확대율은 $0.88{\pm}0.03-3.73{\pm}0.16$으로 기준 위치와 비교 시 통계적으로 유의한 차이를 보인 반면 (P < 0.05), 수직 확대율은 $1.24{\pm}0.01-1.37{\pm}0.02$로 차이가 없었다. 결론: 회전된 머리위치에서 파노라마방사선사진 촬영 시 수평 확대율의 변화가 크다.

파노라마방사선사진에서 환자의 머리 위치가 하악 수직, 수평 확대율에 미치는 영향 : 전후방 및 좌우 이동 (Effect of Head Positioning in Panoramic Radiography on the Vertical and Horizontal Magnification : Displacement along the Sagittal and Transverse Plane)

  • 김용건;이영균;안서영
    • 구강회복응용과학지
    • /
    • 제29권3호
    • /
    • pp.249-258
    • /
    • 2013
  • 이 연구의 목적은 환자의 머리 위치에 따른 파노라마방사선사진의 수평 및 수직 확대율을 비교 평가하는 것이었다. 직경 4 mm인 금속구를 건조 두개골의 하악 전치부와 우측 대구치부의 치조골 상방에 위치시켰다. 수평 및 수직적 위치의 변화를 재현하기 위해 수직, 수평 이동량을 조절할 수 있는 두개골 고정장치를 이용하여, 전방, 후방, 좌측 및 우측으로 이동시킨 후 파노라마방사선사진을 OP-100D를 이용하여 획득하였다. 촬영된 영상은 DICOM 형식으로 저장되었고, INFINITT PACS software를 이용하여 금속구의 폭과 높이의 평균값을 구하였다. 적절한 위치에서 촬영된 파노라마방사선사진에서 금속구의 수평 확대율은 1.224-1.439였고, 수직 확대율은 1.286-1.345였다. 건조 두개골의 위치 변화에 따른 수평 확대율은 0.798-6.297로 통계적으로 유의한 차이를 보인 반면(P<0.05), 수직 확대율은 1.245-1.418 정도로 수평 확대율에 비해 차이를 보이지 않았다.

악성 갈색세포종 및 갑상선수질암의 $^{131}I-MIBG$을 이용한 치료 ($^{131}I-MIBG$ Therapy in Malignant Pheochromocytoma and Medullary Thyroid Carcinoma)

  • 윤종길;류백렬;이창희;정상훈;천영국;최창운;임상무;홍성운
    • 대한핵의학회지
    • /
    • 제29권3호
    • /
    • pp.319-327
    • /
    • 1995
  • 목적 : 악성 갈색세포종 및 갑상선수질암의 치료에서 $^{131}I-MIBG$의 유용성에 대하여 분석하고자 한다. 방법 : 1993년 2월부터 1995년 2월까지 원자력병원에서 $^{131}I-MIBG$를 이용하여 치료한 악성 갈색세포종 3예, 갑상선수질암 6예(1예은 다발성 내분비선종 제IIb 형)에 대한 의무기록을 후향적으로 분석하였다. 결과 : 악성 갈색세포종 3예중 수술후 미소전이 병소에 대해 치료한 1예는 19개월간 무병기간을 유지하고 있으며, 수술후 재발한 1예는 불변, 절제가 불가능한 1예는 진행하였다. 갑상선수질암 6예중 평가 가능한 경우는 5예였으며, 완전관해가 2예, 그 중 1예는 완전관해후 9개월에 재발, 불변이지만 증상의 호전이 1예, 진행이 2예였다. 진행되는 환자의 특징은 진단시에 절제불능이거나 수술후 종양이 남아있는 경우로 보였다. 결론 : $^{131}I-MIBG$ 치료는 수술후 미소전이 병소의 치료와 수술후 재발 혹은 전이성 갈색세포종 및 갑상선수질암에서 일부 효과가 있어 다른 선택 가능한 치료방법이 없을 경우 시도해 볼만한 치료방법으로서 향후 충분한 임상례를 통하여 연구되어야 할 것으로 생각된다.

  • PDF

이수측면에서 평화의댐 활용방안 연구 (Utilization of Peace Dam for Conservation Purpose)

  • 이재응;임동선;이종태
    • 한국수자원학회논문집
    • /
    • 제37권8호
    • /
    • pp.653-662
    • /
    • 2004
  • 본 연구에서는 평화의댐을 화천댐과 연계운영하여 치수측면에서 뿐만 아니라 이수측면에서의 효과를 증대시키는 방안을 모색하였다. 평화의댐은 2003년 2단계 축조공사 완료후 현재 댐 마루표고가 EL.225m에서 증축될 계획이어서 담수능력이 증가될 것이다. 만일 평화의댐 저수용량이 증대되고 수문이 설치된다면 치수뿐만 아니라 이수 측면에서도 한강수계에 도움이 될 것이다. 본 연구에서는 모의운영 기법을 사용하여 평화의댐 상시만수위 변화, 화천댐 하절기 제한수위의 변화, 그리고 평화의댐으로 유입되는 유입량의 변화를 다양하게 고려한 저수지 운영을 실시하여, 신뢰도 95%시 화천댐 연평균발전량, 상시발전량, 용수공급량을 산정하였다. 그 결과 평화의댐 상시만수위와 화천댐 제한수위 증대시 발전량은 증가하나 유입량 감소시에는 발전량에 크게 변화를 미치지 않았다. 용수공급능력은 동일한 조건하에서 유입량 감소시 약 35∼40%가량 감소하므로 일정수준을 유지하려면 평화의댐을 증고하여 상시만수위를 높여야 할 것으로 판단된다.

전기비저항 상시관측에 의한 제체 안전도 지수 산출 (Safety Index Evaluation from Resistivity Monitoring Data for a Reservoir Dyke)

  • 조인기;강형재;이병호;김병호;이상선;박영규;이보현
    • 지구물리와물리탐사
    • /
    • 제9권2호
    • /
    • pp.155-162
    • /
    • 2006
  • 저수지 제체의 누수는 주로 세굴현상에 기인하며, 이 세굴현상은 주변의 토괴를 침식하여 결과적으로 제체의 파괴를 유발시키는 주된 요인이다. 따라서 누수구간의 탐지는 효과적인 제체의 유지관리에 필수적인 요소가 된다. 전기비저항 탐사는 저수지 제체의 안전진단에 가장 널리 사용되고 있는 물리탐사 방법으로 특히 세굴현상에 의한 누수구간의 탐지에 효과적인 것으로 알려져 있다. 하지만 기존의 전기비저항 탐사는 제체 마루에서 수행된 2차원 전기비저항 탐사자료의 역산 단면상에서 저비항대를 누수 위험 구간으로 해석하는 정성적인 단계에 머무르고 있다. 근자에 이르러 상시관측을 통한 전기비저항의 변화율을 이용한 해석방법이 제시되었지만 아직까지 제체의 안전도를 정량적으로 산출하는 기법에 관한 연구는 없는 실정이다. 제체내의 세굴현상이 진행됨에 따라 누수구간은 공극율이 증가하고, 공극율의 증가는 제체의 안전과 직결된다. 본 연구에서는 Archie의 경험식을 근거로 전기비저항 탐사에서 얻어진 건기전도도 자료를 제체부의 공극율로 변환하는 기법을 개발하였다. 또한 전기비저항 상시관측 자료를 이용하여 제체의 안전도 지수를 산출하는 방법론을 제시하고자 하였다.