• Title/Summary/Keyword: CR 분석

Search Result 1,475, Processing Time 0.025 seconds

Characteristics of the HVOF_sprayed $\textrm{Cr}_{3}\textrm{C}_{2}$-NiCr Coationg Layer (HVOF 용사된 $\textrm{Cr}_{3}\textrm{C}_{2}$-NiCr 용사층의 특성)

  • Kim, Byeong-Hui;Seo, Dong-Su
    • Korean Journal of Materials Research
    • /
    • v.8 no.9
    • /
    • pp.849-855
    • /
    • 1998
  • The purpose of this study was performed to compare to the characteristics (microstructure, phase change and hardness, erosion rate) of HVOF sprayed coatings with 20wt% NiCr claded and 7wt%NiCr mixed $\textrm{Cr}_{3}\textrm{C}_{2}$ powder. In the case of the 20wt% NiCr claded $\textrm{Cr}_{3}\textrm{C}_{2}$ powder, microstructural feature showed that the primary $\textrm{Cr}_{3}\textrm{C}_{2}$ was remained in the coating but was barely remained in the mixed $\textrm{Cr}_{3}\textrm{C}_{2}$ coating. As a results of XRD analysis, both 20wt%NiCr claded and 7wt% NiCr mixed $\textrm{Cr}_{3}\textrm{C}_{2}$ powder was decomposed during spraying but the degree of decomposition of the 20wt%NiCr claded was lower than 7wt%NiCr mixed $\textrm{Cr}_{3}\textrm{C}_{2}$ powder. After spraying the mixed powder for microhardness was higher than claded $\textrm{Cr}_{3}\textrm{C}_{2}$ powder and which was increased up to $\textrm{Hv}_{300}$= 1665 after heat treatment to $1000^{\circ}C$. however. 20wt%NiCr claded $\textrm{Cr}_{3}\textrm{C}_{2}$ became to decrease at $600^{\circ}C$ which was the maximum.

  • PDF

Development of PC Based Signal Postprocessing System in MR Spectroscopy: Normal Brain Spectrum in 1.5T MR Spectroscopy (PC를 이용한 자기공명분광 신호처리분석 시스템 개발: 1.5T MR Spectroscopy에서의 정상인 뇌 분광 신호)

  • 백문영;강원석;이현용;신운재;은충기
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.128-135
    • /
    • 2000
  • Purpose : The aim of this study is to develope the Magnetic Resonance Spectroscopy(MRS) data processing S/W which plays an important role as a diagnostic tool in clinical field. Materials and methods : Post-processing software of MRS based on graphical user interface(GUI) under windows operating system of personal computer(PC) was developed using MATLAB(Mathwork, U.S.A.). This tool contains many functions to increase the quality of spectrum data such as DC correction, zero filling, line broadening, Gauss-Lorentzian filtering, phase correction, etc. And we obtained the normal human brain $^1H$ MRS data from parietal white matter, basal ganglia and occipital grey matter region using 1.5T Gyroscan ACS-NT R6 (philips, Amsterdam, Netherland) MRS package. The analysis of the MRS peaks were performed by obtaining the ratio of peak area. Results : The peak ratios of NAA/Cr, Cho/Cr, MI/Cr for the different MRS machines have a little different values. But these peak ratios were not significantly different between different echo time MRS peak ratios in the same machine (p<0.05). Conclusion : MRS post-processing S/W based on GUI using PC was developed and applied to the analysis of normal human brain $^1H$ MRS. This independent MRS processing job increases the performance and throughput of patient scan of main console. Finally, we suggest that the database for normal in-yivo human MRS data should be obtained before clinical applications.

  • PDF

Mössbauer Studies of Changed Interaction on Cr Ions in Chromite (Chromite 물질의 자기상호작용에 관한 뫼스바우어 분광연구)

  • Choi, Kang-Ryong;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.1
    • /
    • pp.47-50
    • /
    • 2007
  • [ $ZnCr_2O_4$ ] shows geometrically frustrated magnet. Recently, $CoCr_2O_4$ has been investigated for multiferroic property and dielectric anomalies by spin-current model. Polycrystalline $CoCr_2O_4$ and $CoCrFeO_4$ compounds was prepared by wet-chemical process. Crystallographic and magnetic properties of $CoCr_2O_4$ and $CoCrFeO_4$ were investigate by using the x-ray diffractometer(XRD), vibrating sample magnetometer(VSM), superconducting quantum interference device magnetometer(SQUID), and $M\"{o}ssbauer$ spectroscopy. The crystal structure was found to be single-phase cubic spinel with space group of Fd3m. The lattice constants of $CoCr_2O_4$ and $CoCrFeO_4$ $a_0$ were determined to be 8.340 and 8.377 ${\AA}$, respectively. The ferrimagnetic transition temperature for the both samples were observed at 97 K and 320 K. The $M\"{o}ssbauer$ absorption spectra at 4.2 K show that the well developed two sextets are superposed with small difference of hyperfine field($H_{hf1}=507\;and\;H_{hf2}=492\;kOe$). Isomer shift values($\delta$) of the two sextets are found to be 0.33 and 0.34 mm/s relative to the Fe metal, respectively, which are consistent with the high spin $Fe^{3+}$ charge state.

Surface Analysis of Ni-Cr and Co-Cr Alloys with Addition of Ti and Mo for Dental CAD/CAM Use (Ti 및 Mo 첨가에 따른 치과 CAD/CAM용 Ni-Cr 및 Co-Cr합금의 표면분석)

  • Moon, Dae-Sun;Choe, Han-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.3
    • /
    • pp.139-148
    • /
    • 2018
  • In this study, surface analysis of Ni-Cr and Co-Cr alloys with addition of Ti and Mo for dental CAD/CAM use has been researched experimentally. The surface characteristics of the alloys were examined by Vickers hardness test, bonding strength test, surface roughness test, field-emission scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction spectroscopy. The shrinkage of the sintered Ni-Cr alloy alloy was slightly larger than that of Ni-Cr-Ti alloy, and larger than Co-Cr alloy. Also, the addition of Mo showed a tendency to decrease shrinkage somewhat. From the result of XRD analysis, NiCr, $Ni_3Cr$ and $Ni_3Ti$ were observed in the sintered Ni-13Cr-xTi and Ni-13Cr-xMo alloys. In addition, ${\sigma}-CrCo$, $Co_2Mo_3$ and $TiCo_2$ were formed in the sintered Co-Cr-xTi and Co-Cr-xMo alloys. Surface hardness of Ti and Mo added alloy was higher than those of Ni-Cr and Co-Cr alloy. The bond strength between sintered alloy and porcelain was $16.1kgf/mm^2$ for Ni-13Cr alloy, $17.8kgf/mm^2$ for Ni-13Cr-5Ti alloy, and $8.2kgf/mm^2$ for Ni-13Cr-10Ti alloy, respectively.

The Flame Color Analysis of Color Models for Fire Detection (화재검출을 위한 컬러모델의 화염색상 분석)

  • Lee, Hyun-Sul;Kim, Won-Ho
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.3
    • /
    • pp.52-57
    • /
    • 2013
  • This paper describes the color comparison analysis of flame in each standard color model in order to propose the optimal color model for image processing based flame detection algorithm. Histogram intersection values were used to analyze the separation characteristics between color of flame and color of non-flame in each standard color model which are RGB, YCbCr, CIE Lab, HSV. Histogram intersection value in each color model and components is evaluated for objective comparison. The analyzed result shows that YCbCr color model is the most suitable for flame detection by average HI value of 0.0575. Among the 12 components of standard color models, each Cb, R, Cr component has respectively HI value of 0.0433, 0.0526, 0.0567 and they have shown the best flame separation characteristics.

Selective Determination Method of Cr(Ⅲ) and Cr(Ⅵ) by Aliquat 336 Extraction and Flame Atomic Absorption Spectrometry (Cr(Ⅲ) 와 Cr(Ⅵ)의 Aliquat 336을 이용한 추출분리 및 원자흡수분광법에 의한 정량)

  • Kim, Cheon Han;Hwang, Hye Ryeon
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.4
    • /
    • pp.418-422
    • /
    • 1999
  • A method is described for the selective determination of Cr(III) and Cr(VI) in aqueous solutios by flame atomic absorption spectrometry. Selective extraction of $Cr_2O_7^{2-}$ was performed by Aliquat 336/NIBK from the mixtures of $Cr^{3+}$ and $Cr_2O_7^{2-}$, and the extraction of $Cr^{3+}$ was followed after complex formation with citrate by using the same extractant. The concentraction of each analyte in the extract was determined by $N_2O-C_2H_2$ flame atomic absorption spectrometry. The recoveries of $Cr^{3+}$ and $Cr_2O_7^{2-}$ from 50mL of aqueous solution ranging 0.1~1.0 ${\mu}g/mL$ as Cr respectively by single extractions with 5 mL of 1%(V/V) Aliquat 336/MIBK were resulted as 98.8∼101.7%.

  • PDF

모재/중간층/박막의 H/E ratio 구배에 따른 Cr계 경질 박막의 기계적 특성에 관한 연구

  • Kim, Hoe-Geun;Song, Myeon-Gyu;Lee, Sang-Yul
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.135-135
    • /
    • 2018
  • 천이금속 질화물 코팅은 우수한 기계적 특성들로 인해 공구 코팅으로 많이 사용 되어왔다. 그 중에서도 특히 Cr계 경질 코팅은 높은 경도와 낮은 표면조도, 우수한 마찰특성 등 뛰어난 기계적 특성을 나타내므로 공구 코팅으로의 적용 가능성이 크다. 그러나 최근 공구산업의 발전으로 인해 공구가 더욱 가혹한 환경에서 사용됨에 따라, 공구의 수명을 향상시키고 보호하기 위해 코팅의 높은 밀착력이 요구되고 있으며, 모재와 코팅 사이에 중간층을 합성함으로써 공구의 밀착력을 향상시키는 연구가 활발히 진행되고 있다. 이전 연구에서 모재/중간층/코팅간의 경도와 탄성계수 비율(H/E ratio)의 구배가 코팅의 밀착력에 큰 영향을 미치는 것으로 확인되었다. 그러므로, WC 모재와 Cr계 코팅의 중간값의 H/E ratio를 갖는 중간층의 합성을 통해 코팅의 밀착력을 향상시킬 수 있을 것으로 판단된다. 본 연구에서는, 코팅의 밀착력을 향상시키기 위해 다양한 중간층을 증착한 CrZrN, CrAlN 코팅을 비대칭 마그네트론 스퍼터링 장비를 이용하여 합성하였다. 모재로는 디스크 형상의 WC-6wt.%Co 시편을 사용하였고 Cr, Zr, Si, Al single 타겟을 이용하여 Cr, CrN, CrZrN, CrZrSiN 등의 중간층이 증착된 코팅을 합성했다. 코팅의 합금상, 경도 및 탄성계수, 미세조직 및 조성, 표면 조도을 확인하기 위해 X-ray diffractometer (XRD), Fischer scope, field-emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDS), atomic force microscopy를 사용하였고, 코팅의 밀착 특성을 분석하기 위해 scratch tester와 optical microscopy (OM)를 이용하였다. 코팅의 내열성을 확인하기 위해 코팅을 furnace에 넣어 공기중에서 500, 600, 700, 800, 900, $1,000^{\circ}C$로 30분 동안 annealing 한 후에 nano-indentation을 사용하여 경도를 측정하였다. CrZrN 및 CrAlN 코팅을 나노 인덴테이션으로 분석한 결과, 모든 코팅의 경도(33.4-35.8 GPa)와 탄성계수(384.1-391.4 GPa)는 중간층의 종류에 상관없이 비슷한 값을 보인 것으로 확인됐다. 그러나, 코팅의 마찰계수는 중간층의 종류에 따라 다른 값을 보였다. CrZrN 코팅의 경우 CrN 합금상 중간층을 갖을 때 가장 낮은 값을 보였으며, CrAlN 코팅의 경우 CrN/CrZrSiN 중간층을 증착하였을때 마찰계수는 0.34로 CrZrN 중간층을 증착하였을 때(0.41)에 비해 낮은 값을 보였다. 또한, 코팅의 마모율 및 마모폭도 비슷한 경향을 보인 것으로 보아, CrN/CrZrSiN 중간층을 합성한 CrAlN 코팅의 내마모성이 상대적으로 우수한 것으로 판단된다. 코팅의 밀착력의 경우도 마찰계수와 비슷한 경향을 보였다. 이것은 중간층의 H/E ratio가 코팅의 내마모성에 미치는 영향에 의한 결과로 사료된다. H/E ratio는 파단시의 최대 탄성 변형율로써, 모재/중간층/코팅의 H/E ratio 구배에 따라 코팅 내의 응력의 완화 정도가 변하게 된다. WC 모재 (H/E=0.040)와 CrAlN 코팅(H/E=0.089) 사이에서 CrN, CrZrSiN 중간층의 H/E ratio는 각각 0.076, 0.083으로 모재/중간층/코팅의 H/E ratio 구배가 점차 증가함을 확인 할 수 있었고, 일정 응력이 지속적으로 가해지면서 진행되는 마모시험중에 CrN과 CrZrSiN 중간층이 WC와 CrAlN 코팅 사이에서 코팅 내부의 응력구배를 완화시키는 역할을 함으로써 CrAlN 코팅의 내마모성이 향상된 것으로 판단된다. 모든 코팅을 열처리 후 경도 분석 결과, CrN/CrZrSiN 중간층을 증착한 CrAlN 코팅은 $1,000^{\circ}C$까지 약 28GPa의 높은 경도를 유지한 것으로 확인 되었고, 이는 CrZrSiN 중간층 내에 존재하는 SiNx 비정질상의 우수한 내산화성에 의한 결과로 판단된다.

  • PDF

RF 스퍼터 처리된 폴리이미드와 Cr 박막간 계면 접착력과 계면 반응성

  • 김동구
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.1 no.1
    • /
    • pp.33-40
    • /
    • 1994
  • 금속박막 증착 전 Ar 이온을 이용한 폴리이미드 표면의 RF 스퍼터링 처리가 Cr/폴 리이미드 계면의 접착력과 반응성에 미치는 영향에 대하여 90。 peel test, TEM, FTIR 및 XPS를 사용하여 연구하였다. Cr/폴리이미드 계면의 접착력은 촐리이미드 표면은 RF 스퍼 터링 처리에 의해 1g/mm에서 100g/mm로 현저히 증가하였다. 표면 비저항 측정과 FTIR 및 XPS 분석결과 RF 스퍼터링 처리에 의한 Cr/폴리이미드 계면의 접착력 증가는 RF 스퍼 터링에 의한 폴리이미드 표면의 chemical modification 에 의해 증착되는 Cr과 계면 반응성 이 향상되는데 기인하는 것임을 밝혔다.

Cr 박막의 이온빔 보조 증착

  • 유광림
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.411-419
    • /
    • 1993
  • 저에너지의 Ar 이온빔으로 Cr 박막을 보조 증착하였으며, 이온빔 보조 증착 박막과 보통 박막의 광학적, 전기적 및 기계적 특성을 비교 분석하였다. 보통 박막에 비해 이온빔 보조증착 Cr 박막의 광학 상수와 반사율은 증가하고 전기비저항은 감소하여 bulk에 가까운 특성을 나타내었으며, 인장 응력은 감소하여 낟알 크기는 큰 차이가 없었다. 성장하는 Cr 박막에 대한 이온빔의 충격과 기판의 이온빔 세척은 박막의 조밀도를 증가시키는 경향으로 박막의 내부 구조에 변화를 주어 Cr 박막의 광학적 및 전기적 특성을 개선시키는 것으로 판단된다.

  • PDF

Syntheses and mechanical properties of Cr-Mo-Si-N coatings by a hybrid coating system (하이브리드 공정을 이용한 Cr-Mo-Si-N 코팅의 합성 및 기계적 성질)

  • Lee, Jeong-Du;Kim, Gwang-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.86-87
    • /
    • 2008
  • 4성분계 Cr-MO-Si-N코팅은 하이브리드 시스템에 아르곤, 질소 가스를 주입하여 스테인리스 기판과 실리콘 웨이퍼에 증착시킨다. XRD, XPS, HRTEM을 이용해 Cr-MO-Si-N코팅의 성분을 분석하고 Si의 함량이 12.1at.%일때 50GPa의 강도가 나오고 이것은 33GPa의 강도Cr-MO-N코팅보다 크게 향상된 것이다.

  • PDF