• Title/Summary/Keyword: CORRECTION

Search Result 9,605, Processing Time 0.033 seconds

Pulmonary Arterial Growth Pattern after Shunt Operation in Patients of Pulmonary Atresia with Ventricular Septal Defect Associated with Juxtaductal Stenosis (Juxtaductal stenosis가 동반된 PA/VSD환자에서 체폐단락술 부위에 따른 폐동맥 크기의 변화)

  • 이교준;박영환;최재영;조범구
    • Journal of Chest Surgery
    • /
    • v.31 no.9
    • /
    • pp.861-866
    • /
    • 1998
  • Background: Pulmonary atresia (PA) with ventricular septal defect has various morphology of pulmonary arteries and pulmonary blood flow sources, so pulmonary arterial hypoplasia and arborization abnormality make this anomaly difficult to manage surgically. In cases associated with juxtaductal stenosis, we evaluated the change of the pulmonary arterial and juxtaductal stenotic site after shunt operations, and would like to find useful information in surgical planning and methodology of these patients. Material and Method: Among 59 cases diagnosed as PA with ventricular septal defect associated with juxtaductal stenosis, 29 cases who had cardiac catheterization before and after shunt operation were selected from July, 1991 to July, 1996. In 10 cases of right shunt operation(Group I) and 19 cases of left shunt operation (Group II), the diameters of the descending aorta, both pulmonary arteries, and the juxtaductal stenosis site were measured before and after the shunt operation. Result: In both Group I and II, the pre- and postoperative ratio of diameters of the ipsilateral pulmonary artery to the descending aorta was from 0.78${\pm}$0.31 units to 1.01${\pm}$0.26 units and from 0.67${\pm}$0.18 units to 0.84${\pm}$0.27 units respectively, showing a signigicant increase. The contralateral pulmonary artery index was increased from 0.92${\pm}$0.28 units to 1.05${\pm}$0.15 units and from 0.94${\pm}$0.27 units to 1.08${\pm}$0.37 units respectively, but could not be confirmed statistically. In both groups, the change of juxtaductal stenosis showed an aggravating tendency but of no statistical significance from 0.43${\pm}$0.27 units to 0.39${\pm}$0.25 units and from 0.32${\pm}$0.10 units to 0.30${\pm}$0.16 units respectively, and we experienced 2 total obstruction in Group II. Because the increased pulmonary blood flow by shunt operation has a favorable effect to the pulmonary arterial growth, the shunt operation is a recommended treatment in patients with hypoplastic pulmonary arteries. But in PA with ventricular septal defects, the change of juxtaductal stenosis is very important. In conclusion, the growth of ipsilateral (shunt site) pulmonary artery was promoted by shunt operation, but there is a tendency for the juxtaductal stenosis to be aggravated. And we experienced 2 total obstruction in Group II. Conclusion: Thus, in cases operated with shunt method, much careful postoperative follow up study including angiographic evaluation is needed, and after the shunt operation on the side of pulmonary artery associated with juxtaductal stenosis, early precise planning for total correction is recommended.

  • PDF

Open Heart Surgery after Pulmonary Artery Banding in Children (소아에서 폐동맥밴딩술후의 개심술 치료)

  • 김근직;천종록;이응배;전상훈;장봉현;이종태;김규태
    • Journal of Chest Surgery
    • /
    • v.32 no.9
    • /
    • pp.781-789
    • /
    • 1999
  • Background: Pulmonary artery banding(PAB) accompanies some risks in the aspect of band complications and mortality in the second-stage operation. To assess these risks of the second-stage operation after PAB, we reviewed the surgical results of the second-stage operation in the pediatric patients who had undergone PAB in infancy. Material and Method: From May 1988 to June 1997, a total of 29 patients with preliminary PAB underwent open heart surgery. Ages ranged from 2 to 45 months(mean 20.6$\pm$9.0 months). Preoperative congestive heart failure conditions were improved after PAB(elective operation group) in 27 patients, but early second-stage procedures were required in the remaining 2 patients due to sustaining congestive heart failure(early operation group). Preoperative surgical indications included 2 double outlet right ventricles(DORV group) and 27 ventricular septal defects as the main cardiac anomaly(VSD group). Result: The mean time interval from PAB to the second-stage operation was 15.5$\pm$8.7 months(range 5 days to 45 months). One patient in the DORV group underwent intraventricular tunnel repair and modified Glenn procedure in the other. In the VSD group, the VSD was closed with a Dacron patch in all patients. Concomitant procedures included a right ventricular infundibulectomy in 4 patients and a valvectomy of the dysplastic pulmonary valve in 1 patient. At the second-stage operations, pulmonary angioplasty was required due to the stenotic banding sites in 18 patients. One patient underwent complete ligation of the main pulmonary artery with the modified Glenn procedure. The mortality at the second-stage operation was 17.2%(5 patients). Causes of death were 4 low cardiac output, and 1 autoimmune hemolytic anemia. Diagnosis with DORV and the early operative group were the risk factors for operative death in this series. There was 1 late death. Conclusion: This study revealed the second-stage operation for pulmonary artery debanding and closure of VSD in children was complicated by the correction of the acquired lesions with a significantly high incidence of morbidity and early postoperative deaths. Primary repair is recommended for isolated VSD, if possible.

  • PDF

Twelve Years of Experience with Vascular Ring Surgery (혈관륜 수술의 12년 경험 보고)

  • Kim, Yun-Seok;Goo, Hyun-Woo;Jhang, Won-Kyoung;Yun, Tae-Jin;Seo, Dong-Man;Park, Jeong-Jun
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.749-756
    • /
    • 2009
  • Background: Vascular ring is a rare anomaly of the aortic arch. We did surgical repair procedures on 16 cases of vascular ring over the past 12 years. This article reviews our results. Material and Method: Between 1995 and 2007, 16 patients (5 with double aortic arch, 7 with right aortic arch-left ligamentum, 4 with pulmonary artery sling) underwent surgical repair. Mean age at the time of the operation were as follows: double aortic arch, $5.7{\pm}5.5$ years; right aortic arch-left ligamentum, $6.1{\pm}13.4$ years; pulmonary artery sling, $2.9{\pm}2.6$ years. Five patients (71%) with right aortic arch-left ligamentum had an associated Kommerell's diverticulum. Two patients (40%) with double aortic arch, 2 patients (28.6%) with right aortic arch-left ligament and 4 patients (100%) with pulmonary artery sling had associated airway stenosis. Cardiac anomalies were present in 8 of 16 patients. Result: There was no peri-operative or post-operative mortality. The mean hospital stay was $27.1{\pm}38.2$ days. None of our patients underwent reoperation. Conclusion: Vascular ring is rare, but, it needs surgical correction. It is important to suspect the diagnosis and to validate with echocardiography. Preoperative and postoperative computed tomography and bronchoscopy are useful to evaluate the airway and surrounding structures.

Recent Early Operative Outcomes of Comprehensive Aortic Root & Valve Reconstruction (CARVAR) Procedure (종합적 대동맥 근부 및 판막 재건술의 최근 초기 수술성적)

  • Lee, Sung-Jun;Shin, Je-Kyoun;Kim, Dong-Chan;Kim, Jin-Sik;Kim, Jun-Seok;Chee, Hyun-Keun;Song, Meong-Gun
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.696-703
    • /
    • 2009
  • Background: A Comprehensive Aortic Root and Valve Reconstruction (CARVAR) procedure is comprised of aortic root wall reconstruction and corrections of the leaflets for treating various aortic valve diseases. We evaluated our recent early clinical experience with the CARVAR procedure. Material and Method: From October 2007 to September 2008, 114 cases (66 males) of CARVAR procedures were performed, The mean patient age was 53 years (range: 14~84) The patients were divided into 4 groups: 1) the AAR group: aortic regurgitation with aortic root wall deformity such as annulo-aortic ectasia or ascending aortic aneurysm (n=18), 2) the IAR group: isolated AR with leaflet abnormality (n=42), 3) the IAS group: isolated aortic stenosis (n=51) and 4) the PAVR group: previous aortic valve replacement (n=3). Sinotubular junction (STJ) reduction was done in all the patients, leaflet correction was done in 10 of the AAR group patients and in all the patients of the other groups, annulus reduction was done in 14 of the MR group patients and in 6 of the IAR group patients. Aortic dissection was excluded from this analysis. Result: There was no mortality or follow-up death. The diameter of the aortic sinus decreased from $54.6{\pm}8.4$ mm to $38.3{\pm}3.8$ mm in the AAR group, the mean AR grade decreased from 3.2 to 0.2 in the IAR group, the mean aortic valve pressure gradient decreased from $47.1{\pm}24.4$ mmHg to $15.1{\pm}11.7$ mmHg in the IAS group and the mean AR grade decreased to 0 in the PAVR group. Balloon type coronary perfusion cannula-related coronary ostial stenosis developed in 4 patients and this was treated with OPCAB in three patients and with PTCA in one patient. Two patients developed postoperative infectious endocarditis. All the patients were discharged and followed up in a stable condition. Conclusion: The CARVAR procedure showed excellent short term results, but a good further follow up result is required to apply this procedure to most kinds of aortic valve diseases.

A Study of a Non-commercial 3D Planning System, Plunc for Clinical Applicability (비 상업용 3차원 치료계획시스템인 Plunc의 임상적용 가능성에 대한 연구)

  • Cho, Byung-Chul;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.71-79
    • /
    • 1998
  • Purpose : The objective of this study is to introduce our installation of a non-commercial 3D Planning system, Plunc and confirm it's clinical applicability in various treatment situations. Materials and Methods : We obtained source codes of Plunc, offered by University of North Carolina and installed them on a Pentium Pro 200MHz (128MB RAM, Millenium VGA) with Linux operating system. To examine accuracy of dose distributions calculated by Plunc, we input beam data of 6MV Photon of our linear accelerator(Siemens MXE 6740) including tissue-maximum ratio, scatter-maximum ratio, attenuation coefficients and shapes of wedge filters. After then, we compared values of dose distributions(Percent depth dose; PDD, dose profiles with and without wedge filters, oblique incident beam, and dose distributions under air-gap) calculated by Plunc with measured values. Results : Plunc operated in almost real time except spending about 10 seconds in full volume dose distribution and dose-volume histogram(DVH) on the PC described above. As compared with measurements for irradiations of 90-cm 550 and 10-cm depth isocenter, the PDD curves calculated by Plunc did not exceed $1\%$ of inaccuracies except buildup region. For dose profiles with and without wedge filter, the calculated ones are accurate within $2\%$ except low-dose region outside irradiations where Plunc showed $5\%$ of dose reduction. For the oblique incident beam, it showed a good agreement except low dose region below $30\%$ of isocenter dose. In the case of dose distribution under air-gap, there was $5\%$ errors of the central-axis dose. Conclusion : By comparing photon dose calculations using the Plunc with measurements, we confirmed that Plunc showed acceptable accuracies about $2-5\%$ in typical treatment situations which was comparable to commercial planning systems using correction-based a1gorithms. Plunc does not have a function for electron beam planning up to the present. However, it is possible to implement electron dose calculation modules or more accurate photon dose calculation into the Plunc system. Plunc is shown to be useful to clear many limitations of 2D planning systems in clinics where a commercial 3D planning system is not available.

  • PDF

Impact Resistance Testing of NK55 Ophthalmic Lenses in Domestic Market (국내 유통 NK55 재질 안경렌즈의 내충격 시험 평가)

  • Park, Mijung;Jeon, Inchul;Hwang, Kwang Hoon;Byun, Woongjin;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • Purpose: The present study was performed to evaluate the safety of ophthalmic lenses in domestic market since eyeglasses wearers could be exposed to the negligent accident by damaged ophthalmic lenses. Method: Totally, 160 ophthalmic lenses (NK55, ${n_{d}}$ = 1.56) with the refractive powers of -3D, -6D, +3D, +6D manufactured by 4 companies in domestic market were evaluated using drop ball test. In accordance with FDA standard, steel ball (~16 g) was freely dropped on these ophthalmic lenses from 127 cm high and the surfaces of lenses were observed. Results: From the study, center thicknesses of NK55 ophthalmic lenses manufactured by 4 different companies showed somewhat different numbers even though the lenses had the same refractive index and powers. All convex lenses of +3D, +6D were evaluated as the safe lenses since there was no damage such as crack and broken found on the lens surfaces after drop ball testing. However, some noticeable broken was shown on the surfaces of concave lenses with relatively thinner center thickness. Especially, 59(73.8%) of total 80 concave lenses with the refractive power of -3D and -6D classified as unacceptable lenses to FDA standard. Conclusions: From the results, the negligent accident by damaged ophthalmic lenses should be considered as well as the correction of visual acuity, design and price when customers purchase eyeglasses. Thus, the enforcement regulation like drop ball testing of uncut ophthalmic lens could be suggested to guarantee the safety of ophthalmic lenses in domestic market.

Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source (고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발)

  • Choi Tae Jin;Yei Ji Won;Kim Jin Hee;Kim OK;Lee Ho Joon;Han Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.283-293
    • /
    • 2002
  • Purpose : A PC based brachytherapy planning system was developed to display dose distributions on simulation images by 2D isodose curve including the dose profiles, dose-volume histogram and 30 dose distributions. Materials and Methods : Brachytherapy dose planning software was developed especially for the Ir-192 source, which had been developed by KAERI as a substitute for the Co-60 source. The dose computation was achieved by searching for a pre-computed dose matrix which was tabulated as a function of radial and axial distance from a source. In the computation process, the effects of the tissue scattering correction factor and anisotropic dose distributions were included. The computed dose distributions were displayed in 2D film image including the profile dose, 3D isodose curves with wire frame forms and dosevolume histogram. Results : The brachytherapy dose plan was initiated by obtaining source positions on the principal plane of the source axis. The dose distributions in tissue were computed on a $200\times200\;(mm^2)$ plane on which the source axis was located at the center of the plane. The point doses along the longitudinal axis of the source were $4.5\~9.0\%$ smaller than those on the radial axis of the plane, due to the anisotropy created by the cylindrical shape of the source. When compared to manual calculation, the point doses showed $1\~5\%$ discrepancies from the benchmarking plan. The 2D dose distributions of different planes were matched to the same administered isodose level in order to analyze the shape of the optimized dose level. The accumulated dose-volume histogram, displayed as a function of the percentage volume of administered minimum dose level, was used to guide the volume analysis. Conclusion : This study evaluated the developed computerized dose planning system of brachytherapy. The dose distribution was displayed on the coronal, sagittal and axial planes with the dose histogram. The accumulated DVH and 3D dose distributions provided by the developed system may be useful tools for dose analysis in comparison with orthogonal dose planning.

Geophysical Studies on Major Faults in the Gyeonggi Massif : Gravity and Electrical Surveys In the Gongju Basin (경기육괴내 주요 단층대의 지구물리학적 연구: 공주분지의 중력 및 지전기 탐사)

  • Kwon Byung-Doo;Jung Gyung-Ja;Baag Chang-Eob
    • The Korean Journal of Petroleum Geology
    • /
    • v.2 no.2 s.3
    • /
    • pp.43-50
    • /
    • 1994
  • The geologic structure of Gongju Basin, which is a Cretaceous sedimentary basin located on the boundary of Gyeonggi Massif and Ogcheon Belt, is modeled by using gravity data and interpreted in relation with basin forming tectonism. The electrical survey with dipole-dipole array was also conducted to uncover the development of fractures in the two fault zones which form the boundaries of the basin. In the process of gravity data reduction, the terrain correction was performed by using the conic prism model, which showed better results specially for topography having a steep slope. The gravity model of the geologic structure of Gongju basin is obtained by forward modeling based on the surface geology and density inversion. It reveals that the width of the basin at its central part is about $4{\cal}km$ and about $2.5{\cal}km$ at the southern part. The depth of crystalline basement beneath sedimentary rocks of the basin is about $700{\~}400{\cal}m$ below the sea level and it is thinner in the center than in margin. The fault of the southeastern boundary appears more clearly than that of the northwestern boundary, and its fracture zone may extended to the depth of more than $1{\cal}km$. Therefore, it is thought that the tectonic movement along the fault in the southeastern boundary was much stronger. These results coincide with the appearance of broad low resistivity anomaly at the southeastern boundary of the basin in the resistivity section. The fracture zones having low density are also recognized inside the basin from the gravity model. The swelling feature of basement and the fractures in sedimentary rocks of the basin suggest that the compressional tectonic stress had also involved after the deposition of the Cretaceous sediments.

  • PDF

Radiation Absorbed Dose Measurement after I-131 Metaiodobenzylguanidine Treatment in a patient with Pheochromycytoma (갈색세포종 환자에서 Medical Internal Radiation Dose법을 이용한 I-131 Metaiodobenzylguanidine 치료 후 흡수선량 평가)

  • Yang, Weon-Il;Kim, Byeung-Il;Lee, Jae-Sung;Lee, Jung-Rim;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Sung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.422-429
    • /
    • 1999
  • Purpose: The measurement of radiation absorbed dose is useful to predict the response after I-131 labeled metaiodobenzylguanidine (MIBG) therapy and determine therapy dose in patients with unresectable or malignant pheochromocytoma. We estimated the absorbed dose in tumor tissue after high dose I-131 MIBG in a patient with pheochromocytoma using a gamma camera and Medical Internal Radiation Dose (MIRD) formula. Materials and Methods: A 64-year old female patient with pheochromocytoma who had multiple metastases of mediastinum, right kidney and periaortic lymph nodes, received 74 GBq (200 mCi) of I-131 MIBG. We obtained anterior and posterior images at 0.5, 16, 24, 64 and 145 hours after treatment. Two standard sources of 37 and 74 MBq of I-131 were imaged simultaneously. Cummulated I-131 MIBG uptake in tumor tissue was calculated after the correction of background activity, attenuation, system sensitivity and count loss at a high count rate. Results: The calculated absorbed radiation dose was 32-63 Gy/ 74 GBq, which was lower than the known dose for tumor remission (150-200 Gy). follow-up studies at 1 month showed minimally reduced tumor size on computed tomography, and mildly reduced I-131 MIBG uptake. Conclusion: We estimated radiation absorbed dose after therapeutic I-131 MIBG using a gamma camera and MIRD formula, which can be peformed in a clinical nuclear medicine laboratory. Our results suggest that the measurement of radiation absorbed dose in I-131 MIBG therapy is feasible as a routine clinical practice that can guide further treatment plan. The accuracy of dose measurement and correlation with clinical outcome should be evaluated further.

  • PDF

Quantification of Cerebrovascular Reserve Using Tc-99m HMPAO Brain SPECT and Lassen's Algorithm (Tc-99m HMPAO 뇌 SPECT와 Lassen 알고리즘을 이용한 뇌혈관 예비능의 정량화)

  • Kim, Kyeong-Min;Lee, Dong-Soo;Kim, Seok-Ki;Lee, Jae-Sung;Kang, Keon-Wook;Yeo, Jeong-Seok;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.322-335
    • /
    • 2000
  • Purpose: For quantitative estimation of cerebrovascular reserve (CVR), we estimated the cerebral blood flow (CBF) using Lassen's nonlinearity correction algorithm and Tc-99m HMPAO brain SPECT images acquired with consecutive acquisition protocol. Using the values of CBF in basal and acetaBolamide (ACZ) stress states, CBF increase was calculated. Materials and Methods: In 9 normal subjects (age; $72{\pm}4$ years), brain SPECT was performed at basal and ACZ stress states consecutively after injection of 555 MBq and 1,110 MBq of Tc-99m HMPAO, respectively. Cerebellum was automatically extracted as reference region on basal SPECT image using threshold method. Assuming basal CBF of cerebellum as 55 ml/100g/min, CBF was calculated lot every pixel at basal states using Lassen's algorithm. Cerebellar blood flow at stress was estimated comparing counts of cerebellum at rest and ACZ stress and Lassen's algorithm. CBF of every pixel at ACZ stress state was calculated using Lassen's algorithm and ACZ cerebellar count. CVR was calculated by subtracting basal CBF from ACZ stress CBF for every pixel. The percent CVR was calculated by dividing CVR by basal CBF. The CBF and percentage CVR parametric images were generated. Results: The CBF and percentage CVR parametric images were obtained successfully in all the subjects. Global mean CBF were $49.6{\pm}5.5ml/100g/min\;and\;64.4{\pm}10.2ml/100g/min$ at basal and ACZ stress states, respectively. The increase of CBF at ACZ stress state was $14.7{\pm}9.6ml/100g/min$. The global mean percent CVR was 30.7% and was higher than the 13.8% calculated using count images. Conclusion: The blood flow at basal and ACZ stress states and cerebrovascular reserve were estimated using basal/ACZ Tc-99m-HMPAO SPECT images and Lassen's algorithm. Using these values, parametric images for blood flow and cerebrovascular reserve were generated.

  • PDF