Development of Corona Cage Measurement System for Simulation on Electrical Environmental Characteristics of HVDC Overhead Transmission Line (HVDC 가공 송전선로 전기환경특성 모의시험용 코로나 케이지 계측시스템 개발)

  • Kil, Gyung-Suk;Yang, Kwang-Ho;Lee, Sung-Doo;Ju, Mun-No
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.245-249
    • /
    • 2006
  • Corona characteristics of conductors are dependent on the electric field conditions in the immediate vicinity of the conductors. In case of DC transmission line, particularly, the space charge plays an important role in the electric field distribution. Therefore, DC corona cage simulation is necessary for long-term test in the same conditions. This paper presents the results of designing and constructing hardwares such as DC power supply, measurement system and DAS to carry out the simulation. The corona cage longitudinally is divided into five equal length sections and three inner sections of those are isolated from the ground of outer cage. The measurement items are radio noise, corona current, television noise, audible noise and meteorological conditions. In the next step, various simulations about the type and configuration of two or three candidate conductors will be conducted. And then finally an environmentally-friendly conductor for HVDC overhead transmission line will be decided.

Reentrainment of Carbon Soot Particles in a Corona Discharge Reactor (코로나 방전 반응기에서 Carbon Soot 입자의 재비산)

  • Lee, Jae-Bok;Hwang, Jung-Ho;Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.7
    • /
    • pp.1002-1009
    • /
    • 2000
  • Among the various types of diesel after-treatment device, the corona discharge reactor may be considered as a powerful process for trapping submicron particles. But after precipitation on the electrodes occurs, the reentrainment of particles is severe and often causes low or negative precipitation efficiency. Experiments were performed to investigate the effect of an applied voltage on the reentrainment of soot particles from the electrodes. A co-annular laminar diffusion flame burner was used as the soot generator. When a highly negative voltage was applied, exfoliation of the deposited soot particles and an increase in concentration of particles smaller than approximately 150 nm were observed. Turbulence induced from the negative tuft corona and sputtering caused particle reentrainment from the corona wire and from plates as well. Under soot laden combustion gas, a streamer corona often occurred in the wire-cylinder reactor. Because of its transient nature, streamer corona violently increased the concentration of reentrained particles and CO gas.

Improvement of Transparent Electrodes Based on Carbon Nanotubes Via Corona Treatment on Substrate Surface (기판의 코로나 표면처리에 의한 탄소 나노튜브 투명전극의 물성 향상)

  • Han, Sang-Hoon;Kim, Bu-Jong;Park, Jin-Seok
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.1
    • /
    • pp.7-12
    • /
    • 2014
  • In this study, we investigate the effects of corona-discharge pre-treatment on the properties of carbon nanotubes (CNTs) which are used as flexible transparent electrodes. The CNTs are deposited on PET (polyethylene terephthalate) substrates using a spray coating method. Prior to the deposition of CNTs, the PET substrates are corona-treated by varying the feeding directions of the PET substrate and the numbers of treatments. The variations in the surface morphologies and roughnesses of the PET substrates due to corona-treatment are characterized via atomic force microscopy (AFM). Dynamic contact angles (DCAs) of the corona-treated PET substrates are measured and analyzed as functions of the treatment conditions. Also, the sheet resistances and visible-range transmittances of the CNTs deposited on PET substrates are measured before and after bending test. The experimental results obtained in this study provide strong evidences that the adhesive forces between CNTs and PET substrates can be substantially enhanced by corona-discharge pretreatment.

A Diagnostic Technique for Power Distribution Line Facilities by the Corona Detector (코로나 검출기를 이용한 배전설비 진단기법)

  • Cho, Yong-Sang;Song, Gyu-So;Choi, Yu-Seong;Park, Tae-Seong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.588-593
    • /
    • 2011
  • The airpollutant may accelerate degradation of power line facilities, and may reduce the life of the electric facilities. In case of korea, there are a tendency that the density of air pollution may be increased by industrial development. while lack of research activity and establishment of a countermeasure on this issue. Recently the occurrence of electricity failure have been reduced on the power transmission and distribution lines. but the occurrence of electricity failure by insulator itself has been increased. It means that we should have develop more clear technique for detection of the wrong insulator. In this study to provide a method for detection of the insulator failure or effective management of the troubled insulator, we analyze the chemical composition of the insulator which used on power distribution line at the sea side locations. To define the relation between insulation and corona intensity, we design and develop an corona detector. We define the variation of insulation by pollution changes on the insulator and verify quantitative relation between corona and insulations using the corona detector.

Electrical Properties Associated with Discharge Developments in Water Subjected to Impulse Voltages

  • Choi, Jong-Hyuk;Lee, Bok-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.156-162
    • /
    • 2010
  • This paper describes electrical and optical characteristics of discharge developments in water under inhomogeneous fields caused by impulse voltages. Predischarge current and discharge light images were observed for different water resistivities and applied voltages between the hemispherical water tank and the needle electrode. The electrical parameters characterizing discharge developments are analyzed based on the discharge light images and voltage-current (V-I) curves, and electrical resistances derived by voltage and current waveforms. As a result, when the streamer corona is initiated at the tip of the needle electrode, the transient resistance suddenly drops and V-I curves form a 'loop'. The length of streamer propagation is increased with increasing peak value of the applied voltage, and the streamer corona extension is enlarged with increasing water resistivity. The electrical resistances before streamer corona initiation are rarely changed by different applied voltages. On the other hand, the electrical resistances after streamer corona initiation are found to be inversely proportional to the peak value of the applied voltage, and the decreasing rates for higher water resistivities are much higher than those for lower water resistivities. The time to streamer corona initiation and the time to the second current peak become shorter as the voltage increases. Finally, the calculated resistances after streamer corona initiation are almost the same trace of measured resistances, but they are smaller than the measured values.

A study on Metaverse Consumer perception survey before and after Covid-19 using CONCOR analysis on BIG Data

  • Min, Byun Kwang;Hwan, Ryu Gi
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.36-40
    • /
    • 2022
  • Many parts of life have been changed due to the unprecedented coronavirus outbreak, and Noncontact has now become a general culture of society around the world. Also, many years later, after the Fourth Industrial Revolution, it is now deeply embedded in the human lifestyle. The purpose of this paper's research is to investigate the metaverse perception before and after Corona. It was confirmed that the number of metaverse, the central keyword, was 70971 before Corona, but 261767 after Corona, which was more than three times the frequency. In addition, it was confirmed that the number of COVID-19, the reference point of this study, increased significantly to 1,9236 during the pre-COVID-19 period. Through this, it can be inferred that the metaverse accelerated and developed significantly after the corona. Metaverse about Keywords such as cryptocurrency, cryptocurrency, coin, and exchange appeared before Corona, and the word frequency ranking for blockchain, which is an underlying technology, was high, but after Corona, the word frequency ranking fell significantly as mentioned above. As such, it was confirmed that keywords for metaverse were changing before and after Corona, and as such, Consumers' perceptions were also changing.

The Characteristics of Dust Removal in Flue Gas by the Plasma of Impulse Streamer Corona (충격식 코로나 방전 플라즈마를 이용한 배연가스로부터 먼지제거에 대한 특성)

  • 김은호
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1261-1267
    • /
    • 2003
  • On the basis of the distribution of particle size measured by laser diffraction spectrometers, this research was carried out to investigate the characteristics of mist removal with the change of operating condition in the plasma reactor of impulse streamer corona. The operating parameters in this experiment were power of impulse streamer corona, gas velocity, impulse generation time, gas temperature, and SOx/NOx concentration. The collection efficiency T(d) was estimated by the distribution of particle size in the collection zone through the advanced model.

The Technology of Mist Removal in Flue Gas by the Plasma of Impulse Streamer Corona (저온플라즈마에 의한 배연 가스내의 미스트 처리기술)

  • 하상안;김일배;강신묵
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.69-76
    • /
    • 1999
  • This research was carried but to investigate the characteristics of mist removal with the change of operating conditions in the plasma reactor of impulse streamer corona based on the distribution of particle size measured by laser diffraction spectrometers. The operating conditions in this experiment were power of impulse streamer corona, gas velocity, collection time, and SOx/NOx concentration. The collection efficiency T(d) was estimated by distribution of particle size in the collection zone through the advanced model.

  • PDF

Surface Deterioration Phenomena in Polyethylene under Corona Discharge (Corona 방전에 의한 Polyethylene의 표면열화현상)

  • 성영권;송진수;민남기
    • 전기의세계
    • /
    • v.24 no.5
    • /
    • pp.82-90
    • /
    • 1975
  • This study investigated the deterioration phenomena of the Polyethylene surface contaminated with organic(Saccharose) or inorganic(NaCl) matters through electrical and optical experiments. And also these experimental results relatively well coincided with which was treated by theoretical process. On the electrical experiment, relation between electric field intensity in corona discharge and time reached to the breakdown, and relation between total amount of charges discharged and increment of applied voltage were investigated. On the optical experiment, discharge time dependence of surface deterioration rate and process of surface deterioration in the X-ray diffraction pattern were investigated. It was concluded that chemical effects by the corona discharge deteriorated insulation characteristics of Polyethylene surface.

  • PDF

3-Dimensional Analysis II on Electric Field of Special Conductor Bundle for Reducing Aeolian Noise In Corona Cage (코로나 케이지 내부에서의 풍소음 저감용 특수 다중도체 방식의 3차원 전계분포해석 II)

  • Min, Suk-Won;Song, Ki-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.399-402
    • /
    • 2001
  • In this paper, 3-dimensional charge simulation method was applied to analyze electric field distributions of special conductor bundles equipped with spiral rods for reducing aeolian noise in a corona cage. Comparing electric field distributions of special conductor bundles in 765kV transmission tine with ones in corona case, we decide experimental voltages of special conductor bundles in corona cage.

  • PDF