• 제목/요약/키워드: COOL ISLAND

검색결과 40건 처리시간 0.033초

친환경 세라믹 도료 열적측정을 통한 쿨루프 정책 확대방안 (Expansion of Cool Roof Policy through Thermal Measurement of Eco-Friendly Ceramic Coating)

  • 박민용;이동호
    • 토지주택연구
    • /
    • 제11권3호
    • /
    • pp.75-82
    • /
    • 2020
  • The urban heat island phenomenon that accelerates global warming has always been controversial when summer heatwaves have occurred since it was first investigated and described by Luke Howard in the 1810s. In Korea, since 2014, government have been interested in Cool Roof and painted white coating on the rooftops of the aging and weak buildings, and the cool roof business has expanded nationwide. However, the roof occupies 20-25% of the entire city surface, much less than 37-45% of the pavement area consisting of roads, parking lots and sidewalks, there is a need to expand the policy of Cool Pavement as a way to reduce the urban heat island phenomenon. Domestic cities are high-rise buildings centered on apartments, and the area occupied by outer walls is larger than that of rooftops compared to foreign low-rise buildings. Therefore, as a way to reduce the urban heat island phenomenon, there is a need for a policy to expand the Cool Roof in buildings and use Cool Wall in parallel. Therefore, this study aims to present the expansion of Cool Wall in buildings and Cool Pavement in urban areas, expanding the installation range of Cool Roof, by comparing and reviewing the thermal characteristics of eco-friendly ceramic coating with excellent thermal proof performance and coatings used for roof waterproofing.

대구 도심에 위치한 대규모 녹지공간의 냉섬 강도: 계절변화와 기상조건에의 관련성 (Cool Island Intensity in a Large Urban Green in Downtown Daegu: Seasonal Variation and Relationship to Atmospheric Condition)

  • 박명희;김해동
    • 한국환경과학회지
    • /
    • 제19권1호
    • /
    • pp.81-87
    • /
    • 2010
  • Cool island intensity urban green space was investigated based in Dalsung Park, that is one of the largest parks in Daegu. Cool island intensity(CII), which is defined as the temperature difference between the green space and its surrounding built-up areas, shows time variations. A through-year measurement(2008-2009) of ground level air temperature revealed seasonal variation and relationship to the atmospheric condition of CII. The temperature variation in the park and the reference downtown Daegu was as same order as CII. The noontime CII is larger in summer than that in winter due to the leaf fall of the park trees. On the other hand, seasonal variation of nighttime CII is not so clear. The nighttime CII was larger under the stable atmosphere.

일방향 주기적 진동하는 원통 내의 유동 및 열전달 연구 (A Study on Flow and Heat Transfer in One Directional Periodic-Oscillating Cylinder)

  • 박준상
    • 한국유체기계학회 논문집
    • /
    • 제13권5호
    • /
    • pp.22-28
    • /
    • 2010
  • A study has been made of cool-down process on an incompressible fluid contained in a periodically oscillating cylinder when an abrupt cooling of wall temperature is imposed. Characteristics of flow and heat transfer are investigated along the variations of oscillating frequency and amplitude. One found the flow regimes are divided into 4-modes : 1 thermal island mode, 2 thermal island mode, 4 thermal island mode and asymmetry mode. Comprehensive analysis for each mode are given with a physical mechanism on cool-down process.

드론을 활용한 도시폭염지역의 열섬 저감기법 효과 비교 분석 (Comparative Analysis of the Effects of Heat Island Reduction Techniques in Urban Heatwave Areas Using Drones)

  • 조영일;윤동현;신지영;이명진
    • 대한원격탐사학회지
    • /
    • 제37권6_3호
    • /
    • pp.1985-1999
    • /
    • 2021
  • 본 연구의 목적은 EPA(Environmental Protection Agency)에서 활용하는 도시열섬 저감기법(옥상녹화, 쿨루프, 차열도료포장 및 차열블럭포장 등)을 연구지역에 적용하여 토지피복 객체간 비교 분석으로 실질적 효과 파악을 목적으로 한다. 이를 위해, 경상남도 김해시 장유무계지역을 연구지역으로 선정하고, 드론 DJI Matrice 300 RTK에 열적외선 영역센서 FLIR Vue Pro R과 가시광선 영역센서인 H20T 1/2.3" CMOS, 12 MP를 활용하여 계측하였다. 계측 일정은 7월 27일 아침 7시 15분부터 저녁 7시 15분까지 1시간 30분 간격으로 총 9장의 열지도와 비교군 토지피복 객체(711개) 열섬 저감기법 토지피복 객체(180개) 를 추출하였다. 추출한 180개의 객체 별 효과값 산출 후, 기법 종류별 효과를 종합한 결과 주간시간 기준 쿨루프 4.71℃, 옥상녹화 3.40℃, 차열도료포장 0.43℃, 차열블록포장 -0.85℃의 열섬 저감효과가 있는 것으로 분석되었다. 시간대별 효과 비교 결과 촬영일 기준 남중시각 인근인 13시에서 기법들의 열섬 저감효과가 가장 높은 것으로 나타났으며, 해당 시각을 지난 13시에서 14:30분 사이에 쿨루프 -8.19℃, 옥상녹화 -5.56℃, 차열도료포장 -1.78℃, 차열블록포장 -1.57℃의 온도 저감의 효율이 변화하였다. 본 연구는 드론과 같은 고해상도 영상을 활용하여 도시열섬 저감기법을 검증한 사례 연구이다. 향후, 고정밀 공간해상도를 가지는 초소형 위성 등의 직접적인 활용 예시가 가능할 것으로 사료된다.

대도시에 있어 냉섬의 유형별 온도완화 효과 -대구광역시의 사례 연구- (Effect of Cool Islands on the Thermal Mitigation in Urban Area -Case Study of Taegu Metropolitan City-)

  • 박인환;장갑수;김종용;박종화;서동조
    • 한국조경학회지
    • /
    • 제28권1호
    • /
    • pp.11-18
    • /
    • 2000
  • Taegu is notorious as hot and dry summer among Korea cities. One of the most important goals of the open space planning is to ameliorate urban climate of the city. The objective of this research is to evaluate the thermal mitigation effect of the cool islands in Taegu metropolitan city. Cool islands of this paper includes parks and rivers surrounded by or adjacent to urbanized areas. Based on the analysis of the thermal band of Landsat TM at May 17, 1997, the thermal mitigation effect of open spaces in the city could be summarized as follows ; Kumho river showed the largest mitigation effect in terms of the width of mitigation zone and temperature difference. Evaporation from wide water surface and evapo-transpiration from riparian grass land could bring into results. Significant mitigation effect of parks covered with forest can be observed. The temperature range of such parks were between 19.05$^{\circ}C$ and 19.44$^{\circ}C$ However, the thermal mitigation effect of Dalsung park and Apsan park was insignificant. The small size and high percentage of hard paving of the former and the relative low density of the residential areas adjacent to the latter could be the main reason. In conclusion, the thermal mitigation effect in urban ope spaces could be detectedby the employment of thermal band data of Landsat TM and GIS buffering technique.

  • PDF

차열도료용 Cool Pigment 및 Paint 개발 (Development of IR Reflective Cool Pigment and Paint)

  • 권면주;도영웅;하진욱
    • 한국산학기술학회논문지
    • /
    • 제13권8호
    • /
    • pp.3800-3805
    • /
    • 2012
  • 본 논문에서는 도심 열섬현상 방지 및 에너지 효율을 높이기 위하여 적외선 반사율이 30%이상인 건물 내 외장재용 흑색 차열안료 및 도료에 대한 연구를 하였다. 안료는 $Fe_2O_3$$Cr_2O_3$의 혼합원료를 $900{\sim}1,200^{\circ}C$에서 소성하여 합성하였으며, 도료는 합성한 안료에 아크릴수지와 기타첨가제를 사용하여 제조하였다. 연구결과, Cr과 Fe을 1:0.9 몰비로 혼합하여 $1,000^{\circ}C$에서 소성한 안료의 발색도가 가장 우수하였고, 차열안료 20%에 분산제 1.5%를 첨가하여 제조한 차열도료로 $125{\mu}m$ 두께의 도막을 형성시켰을 때 적외선 반사가 가장 우수하였다. 차열도료와 일반도료의 표면온도 차이는 $36.5^{\circ}C$로 나타났으며 700~2,500nm 파장대의 적외선 반사율(TSR)은 39.3%로 측정되었다. 또한, 500시간의 내후성 평가에서 색상변화는 거의 나타나지 않았다.

독도의 식물 한약자원에 관한 본초학적 연구 (A herbological study on the native plants of Dokdo island)

  • 노성수;서부일;박지하
    • 대한본초학회지
    • /
    • 제27권2호
    • /
    • pp.17-24
    • /
    • 2012
  • Objective : For the purpose of investigating the herbal resources of Dokdo island, this study was designed. Method : For the first time, we searched the native plants of Dokdo island from research data. And we examined herbological books on the plants of Dokdo island. Result : The native herbaceous plants in Dokdo island were 27 family and 73 species, and the medicinal plants were 49 species among them. The woody plants in Dokdo island were 12 family and 13 species, and the medicinal plants were 10 species among them. The main medicinal parts of medicinal plants were the whole body of herbs, roots, and seeds in order. The herbal medicines with cold or cool nature were 45 species, they took the top nature of the herbal medicines. According to the properties and principal action of native herbal medicines in Dokdo island, the major parts were classified into drugs for clearing away heat, eliminating toxin, activating blood flow and removing blood stasis, urination, removing heat from the blood and stopping of bleeding. The number of native herbal medicines with small toxicity in Dokdo island were 7 species. Conclusion : For the purpose of preserving the native plants of Dokdo island, we should recognize not only medical benefits but also matters that demand special attention.

쿨루프 적용에 따른 업무용 건물의 내·외부 온도 저감 효과 (Reduction in Indoor and Outdoor Temperature of Office Building with Cool Roof)

  • 송봉근;김경아;박경훈
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.95-101
    • /
    • 2016
  • Purpose: This study aims to identify the effect of temperature reduction by the application of cool roof coatings to Changwon City Hall in South Gyeongsang Province. The indoor and outdoor temperatures of the cool roofing building were analyzed and compared to that of an existing building with green-colored roof coated with waterproof polyurethane. Method: The surface temperatures and reflectivity of rooftops, surface temperatures of ceilings and the interior, and outdoor temperature and humidity of the two aforementioned buildings were measured from June to September in 2014. The measurements were taken every 10 min. Result: The surface temperature of the building with the cool roof was lower by a maximum of $9^{\circ}C$ with the reflectivity of the rooftop at an average of 0.55, which is higher than that of the building with green polyurethane by approximately 0.3. The temperature of the ceiling inside the building with the cool roof was about $1{\sim}2^{\circ}C$ lower than that of the ordinary building. Also, the indoor temperature of the office with cool roof coatings was about $0.5{\sim}1.0^{\circ}C$ lower than that of the office with green-colored roofing building. The results show that cool roof coatings can lower the temperature of buildings. In the next research, the reduction in consumption of energy for air conditioning will be investigated by utilizing building energy simulation tools.

아크릴 수지를 이용한 차열성 포장의 실내 및 현장 공용성 평가 (Laboratory and Field Performance Evaluation of Acryl Resin Based Solar Radiation Reflective Pavement)

  • 소경락;이현종;백종은;이상염
    • 한국도로학회논문집
    • /
    • 제13권4호
    • /
    • pp.19-28
    • /
    • 2011
  • 본 연구에서는 도심지 열섬현상을 완화 시킬 수 있는 아크릴 수지와 차열안료를 혼합한 차열성 포장을 개발하였다. 태양 복사열에 의한 포장체의 온도상승을 모사한 실내 시험으로부터 $60^{\circ}C$의 포장 온도에서 차열성 포장이 $12^{\circ}C$ 이상의 온도 저감 효과를 나타냈다. 이러한 온도 감소 효과는 차열안료의 배합비가 증가함에 따라 증가하였고, 반면에 점도의 증가로 인하여 작업성은 떨어졌다. 이러한 결과로부터 아크릴 수지 대비 차열안료의 최적혼합비율을 15%로 결정하였다. 차열성 포장의 칸타브로 손실률은 일반 배수성 포장의 손실률 1/4 수준으로 골재 비산 저항성이 우수하게 나타났다. 휠트랙킹 시험결과 차열성 포장의 동적안정도가 일반 배수성 포장에 비해 두 배 증가하였다. 차열성 포장재의 높은 부착력으로 인하여 탈리에 의한 손상 가능성은 낮은 것으로 나타났다. 시험 시공 구간에서의 소음도 측정 시험 결과 일반 배수성 포장에 비하여 평균 3.7dB의 소음저감 효과가 있었고, 미끄럼 저항치는 일반 배수성 포장에 비해서 평균 30% 정도 높아 우수한 미끄럼 저항성을 가지는 것으로 판단된다. 투수 시험 결과 차열성 포장의 투수성은 일반 배수성 포장보다 다소 작았으나 국내 배수성 포장 기준을 만족하는 것으로 나타났다.