• 제목/요약/키워드: CONDITION FACTOR(K)

검색결과 2,646건 처리시간 0.031초

자동차용 강재 풀리의 설계 기준에 대한 연구 (A Study of the Design Criterion of a Steel Pulley for an Automobile)

  • 황범철;장재덕;주인식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.71-74
    • /
    • 2005
  • More than five pulleys are used in an automobile, such as crankshaft, water pump, air-con compressor, fan and power steering pump pulley. These pulleys are parts that need durability until retiring a car. But there is no design criterion for durability, so pulleys are designed by the experience of designer and trial and error. So, in this study, we carried out stress analysis at durability test condition and compared analysis results to durability test results. It is found that the design criterion for durability is defined as a safety factor and a safety factor is different according to the distance between the center line of v-grooves and the mating surface.

  • PDF

Dead Angle Reduction of Single-Stage PFC Using Controllable Coupled Inductors

  • Tavassol, Mohammad Mehdi;Farzanehfard, Hosein;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.78-85
    • /
    • 2015
  • This paper presents a new structure of single-stage flyback power factor correction (PFC) converter with a controllable coupled negative magnetic feedback (NMF) winding. NMF winding is used to reduce the bulk capacitor voltage at high line voltages and light loads. However, it would cause line current distortion at zero crossing condition. In the proposed circuit, a series winding is used with NMF inductor to eliminate the NMF inductor at low line voltages. As a result, the dead angle of the input current, near zero voltage crossing, is eliminated and the power factor is increased. The presented experimental results of the proposed PFC converter confirm the integrity of the new idea and the theoretical analysis.

정상침투조건에서 흡입응력을 고려한 불포화 무한사면의 안정해석 (Stability Analysis of the Unsaturated Infinite Slope Considering Suction Stress under Steady Infiltration Condition)

  • 송영석
    • 한국지반공학회논문집
    • /
    • 제29권9호
    • /
    • pp.5-15
    • /
    • 2013
  • 본 연구에서는 흡입응력을 고려한 불포화 사면의 안정해석기법(Lu and Godt, 2008)을 제시하고, 모래로 구성된 특정사면에 대하여 적용한 결과를 분석하였다. 흡입응력을 고려한 불포화 사면의 안정해석기법은 강우의 침투 및 비침투에 따른 해석이 가능하고, 토층내 깊이에 따른 사면안전율을 산정할 수 있다. 또한 지표면으로부터 일정깊이까지의 풍화작용에 의한 영향을 고려할 수 있다. 이를 위하여 상대밀도 60%의 주문진 표준사로 구성된 불포화 무한사면에 대하여 흡입응력을 고려한 안정해석기법을 적용하였다. 강우의 비침투 조건에서 흡입응력은 지하수위로부터 상부의 일정깊이까지만 영향을 미치는 것으로 나타났으나, 강우의 정상침투 조건에서 흡입응력은 토층내 전체적으로 영향을 미치며, 지표면 부근에서 흡입응력이 가장 크게 발현됨을 알 수 있다. 강우의 비침투 조건에서 무한사면의 안전율은 지하수위에 의한 흡입응력의 영향범위 내에서 급격하게 증가 및 감소하였다. 사면안정해석결과 지표면으로부터 2.4m사이에서 사면안전율이 1이하 이므로 해당깊이에서 사면파괴가 발생될 가능성이 높은 것으로 나타났다. 강우의 정상침투가 발생되는 조건에서 무한사면의 안전율은 침투로 인한 토층내 흡입응력의 영향으로 비침투 조건에 비해 증가함을 알 수 있다. 그러나 강우의 정상침투율이 포화투수계수에 가까워짐에 따라 사면안전율은 감소하는 경향이 나타났다. 강우의 정상침투율이 $-1.8{\times}10^{-3}cm/s$인 경우 무한사면의 안정해석결과 지표면으로부터 0.2m에서 3m 사이에서 사면안전율이 1 이하이므로 해당깊이에서 사면파괴가 발생될 가능성이 높으며, 이는 얕은 산사태의 발생형태임을 알 수 있다.

전력케이블 열화진단을 위한 극저주파 탄델타 판정기준의 통계적 해석 (A Statistical Analysis to the VLF Tanδ Criteria for Aging Diagnosis in Power Cables)

  • 정우성;김성민;임장섭;이진
    • 한국전기전자재료학회논문지
    • /
    • 제33권1호
    • /
    • pp.1-5
    • /
    • 2020
  • In this study, the objective is to improve the criteria used for statistical comparison of the VLF tanδ (TD) database and failure rate according to water-tree degradation in underground distribution power cables. The aging condition of the KEPCO criteria is divided into 6 levels using the Weibull distribution, and the "failure imminent" condition is quantified by using the statistical end-point of the lifetime parameter of the VLF big-data group obtained from KEPCO. Moreover, new criteria with a 2-dimensional combination of TD, DTD, and a statistical normalized factor are suggested. These criteria exhibit high reproducibility for the detection of cables in an imminent failure state. Consequently, it is expected that the adoption of the extended VLF-2019 criteria will reduce the asset management cost of cable replacement compared to the VLF-2012 criteria of KEPCO.

핀칼라와 튜브의 간극에 따른 열교환기의 열전달 특성 (Heat Transfer Characteristic of Finned-tube Heat Exchangers with Different Clearance between Fin Collar and Tube Surface)

  • 박영민;정영만;이재근;박내현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1073-1078
    • /
    • 2009
  • Finned-tube heat exchangers are often made with aluminum fins and copper tubes. Usually the contact between fin collar and tube surface for finned tube heat exchanger is secured by mechanical expansion of the tubes. The objective of the present study is to apprehend how much effect clearance has on the performance of heat exchanger. This effect is studied using an experimental approach. The thermal fluid measurements are made using a psychometric calorimeter. Frontal air velocity varies in the range from 1.0m/s to 3.0 m/s. The heat transfer rate of sample which has bigger clearance is only 27% compare with the other's in dry condition. In wet condition, its heat transfer rate is 78% compare with the other's.

  • PDF

NEIGHBORHOOD CONDITION AND FRACTIONAL f-FACTORS IN GRAPHS

  • Liu, Hongxia;Liu, Guizhen
    • Journal of applied mathematics & informatics
    • /
    • 제27권5_6호
    • /
    • pp.1157-1163
    • /
    • 2009
  • Let G be a graph with vertex set V(G) and let f be a nonnegative integer-valued function defined on V(G). A spanning subgraph F of G is called a fractional f-factor if $d^h_G$(x)=f(x) for all x $\in$ for all x $\in$ V (G), where $d^h_G$ (x) = ${\Sigma}_{e{\in}E_x}$ h(e) is the fractional degree of x $\in$ V(F) with $E_x$ = {e : e = xy $\in$ E|G|}. In this paper it is proved that if ${\delta}(G){\geq}{\frac{b^2(k-1)}{a}},\;n>\frac{(a+b)(k(a+b)-2)}{a}$ and $|N_G(x_1){\cup}N_G(x_2){\cup}{\cdots}{\cup}N_G(x_k)|{\geq}\frac{bn}{a+b}$ for any independent subset ${x_1,x_2,...,x_k}$ of V(G), then G has a fractional f-factor. Where k $\geq$ 2 be a positive integer not larger than the independence number of G, a and b are integers such that 1 $\leq$ a $\leq$ f(x) $\leq$ b for every x $\in$ V(G). Furthermore, we show that the result is best possible in some sense.

  • PDF

자침시(刺鍼時) 압침(押鍼)의 수기자극(手技刺戟)이 전위변화(電位變化)에 미치는 영향(影響) (A Study on the changes of electric charge induced by Apchim (押鍼) manipulation during acupuncture therapy)

  • 송문영;심원보;김영태;백대봉;안성훈;김경식;손인철
    • Korean Journal of Acupuncture
    • /
    • 제22권4호
    • /
    • pp.9-27
    • /
    • 2005
  • Objective : hypothesis. First of all, there exists electric property in meridian and meridian point. Second of all, energy flowing in meridian is related with electric property. Third of all, there is electronic interaction between the operator who performs acupuncture therapy and the receiver who is given acupuncture therapy. Forth of all, acupuncture effects may depend on the electric capacity which is transferred between the operator and the receiver via acupuncture needle. Methods : Under the hypothesis, I studied the effects of electric charge in ST37(+) and ST39(-) generated by Apchim (押鍼) manipulation which was stimulated at ST36 point. And compared with data on the changes of electric charge from the hand of the operator during acupuncture stimulation. Electric charge induced via acupuncture needle from the operator may be important factor that causes the changes of electric charge in meridian and acupoint in the receiver. Therefore we investigated the changes of electric charge induced by the operator using Maclab 400 by the following methods. The one was in stable electric circle condition and the other was in unstable electric circle condition. In this experiments, the changes of electric charge from the stimulation type of Apchim manipulation performed in our lab condition in acupuncture therapy was induced at least three factor, one was the difference of bio-potentials between the operator and the receiver of acupuncture therapy, another was the depth of acupuncture insertion from the skin of the receiver the other was an electromyogram of the receiver. Results :The data imply that the first factor should make a capacitance current when the operator touched the acupuncture needle which was inserted in the receiver. Therefore, the results suggest that capacitance currents stimulus in electronic view may be important factor in acupuncture therapy between the operator and the receiver of acupuncture therapy.

  • PDF

슬릿과 평판 핀-관 열교환기의 공기측 열전달 및 마찰특성 (Air-side Heat Transfer and Friction Characteristics of Finned Tube Beat Exchangers with Slit Fin or Plain Fin)

  • 권영철;장근선;박병권;권정태;정지환
    • 에너지공학
    • /
    • 제16권1호
    • /
    • pp.7-14
    • /
    • 2007
  • 본 연구는 핀-관 열교환기의 건표면과 습표면 조건에서의 공기측 열전달 및 마찰특성을 실험을 통해 이해하고자 수행하였다. 핀-관 열교환기의 성능평가 및 해석기술을 확보하기 위하여 공기엔탈피식 칼로리 미터를 이용하였다. 핀형상은 슬릿과 평판이며, 관경은 7.0mm로 2열과 3열 핀-관 열교환기 4종에 대해 실험하여, 건표면과 습표면의 공기측 열전달 및 마찰특성을 조사하였다. 습표면에서 습도변화(RH 50%, 70%)에 따른 습도영향도 조사하였다. 건표면 조건에서 Re 수가 증가할수록 j 계수는 감소하며, 2열이 3열보다 높았다. 마찰계수는 슬릿 핀이 평판 핀보다 높았다. 습표면 조건에서 슬릿 핀이 평판 핀보다 그리고 2열이 3열보다 우수한 열전달효과를 나타내었다. j 계수와 마찰계수는 습도변화, 열수, 핀 형상에 따라 달라짐을 확인하였다.

Stress Intensity Factor for the Cracked Plate Reinforce with a Plate by Seam Welding

  • Kim, O.W.;Park, S.D.;Lee, Y.H.
    • International Journal of Korean Welding Society
    • /
    • 제1권2호
    • /
    • pp.18-22
    • /
    • 2001
  • The stress intensity factor has been calculated theoretically for the cracked plate subjected to remote normal stress and reinforced with a plate by symmetric seam welding. The singular integral equation was derived based on displacement compatibility condition between the cracked plate and the reinforcement plate, and solved by means of Erdogan and Gupta's method. The results from the derived equation for stress intensity factor were compared with FEM solutions and seems to be reasonable. The reinforcement effect gets better as welding line is closer to the crack and the stiffness ratio of the cracked plate and the reinforcement plate becomes larger.

  • PDF

Approximation Method for the Calculation of Stress Intensity Factors for the Semi-elliptical Surface Flaws on Thin-Walled Cylinder

  • Jang Chang-Heui
    • Journal of Mechanical Science and Technology
    • /
    • 제20권3호
    • /
    • pp.319-328
    • /
    • 2006
  • A simple approximation method for the stress intensity factor at the tip of the axial semielliptical cracks on the cylindrical vessel is developed. The approximation methods, incorporated in VINTIN (Vessel INTegrity analysis-INner flaws), utilizes the influence coefficients to calculate the stress intensity factor at the crack tip. This method has been compared with other solution methods including 3-D finite element analysis for internal pressure, cooldown, and pressurized thermal shock loading conditions. For these, 3-D finite-element analyses are performed to obtain the stress intensity factors for various surface cracks with t/R=0.1. The approximation solutions are within $\pm2.5%$ of the those of finite element analysis using symmetric model of one-forth of a vessel under pressure loading, and 1-3% higher under pressurized thermal shock condition. The analysis results confirm that the approximation method provides sufficiently accurate stress intensity factor values for the axial semi-elliptical flaws on the surface of the reactor pressure vessel.