Reuse of Weaving Wastewater by Membrane Bioreactor Equipped with a Hollow-fiber MF Membrane (중공사 정밀여과 MBR공정을 이용한 제직폐수의 재이용)

  • Jung, Yong-Jun;Bae, Jong-Hong;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.365-369
    • /
    • 2004
  • Submerged membrane bio-reactor equipped with a hollow fiber microfiltration was applied to reuse weaving wastewater of water jet loom, where two parameters such as the concentration of MLSS and the flux were controlled. While the flux at the concentration of MLSS around 900mg/L was constantly kept over 0.4m/d and 0.8m/d in a short time, the stable flux at around 300mg/L of MLSS was shown at the 8 days later. Regardless of MLSS and flux, BOD, CODcr and Turbidity of the permeate were 1~2mg/L, 7~10mg/L and below 1 NTU, which were 85~90%, 87~90% and 98% of removal efficiency, respectively. The stable operation without fouling was achieved because the contents of ECP were smaller than those of common MBR processes and the composition(saccharide/protein) was kept constantly. In this study, 0.5~1.0m/d of flux and 400~900mg/L of MLSS were considered as the most recommendable operating condition for the reuse of weaving wastewater.

A Study on the Pretreatment Process for Sewage Reuse by Microfiltration Process (정밀여과에 의한 하수고도처리수의 재이용을 위한 전처리법에 관한 연구)

  • Kuk, Young-Long;Joo, Jae-Young;Bae, Yoon-Sun;Lee, Hye-In;Jung, In-Ho;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.595-601
    • /
    • 2010
  • It is evident that Korea will continue its battle with water shortage and alternative program are being taken into action. One of the main actions is reusing 1,800 tons of effluent of 357 sewage treatment plant located nationwide. Therefore this study supplemented ozone oxidation methods that would increase the efficiency of organic oxidation and coagulation. Through this method, fouling will be controled sufficiently by preventing membrane process in the system for advanced sewage treatment. In this study, ozone-coagulation-microfiltration membrane were used. The final removal efficiency of the pretreated water from the result of the ozone-coagulation were 50% of CODcr, 38% of TP and 11% of TOC respectively. Water quality treatment has decreased about 80% for TP. Ozone-coagulation-microfiltration membrane maintains the high flux while decreasing the number of organic matter and the membrane fouling, and reducing the TP. As a result, in order to reuse the water from the sewage, the ozone-coagulation-microfiltration membrane type must be considered in order to achieve the best efficiency.

A Submerged Membrane Bioreactor with Anoxic-oxic Recycle for the Treatment of High-strength Nitrogen Wastewater

  • Shim, Jin-Kie;Yoo, Ik-Keun;Lee, Young-Moo
    • Korean Membrane Journal
    • /
    • v.3 no.1
    • /
    • pp.32-38
    • /
    • 2001
  • Using the hollow fiber membrane module in a lab-scale membrane bioreactor, the anoxic- oxic (AO) process for nitrogen removal was operated for about one year. For the influent wastewater containing 1,200-1,400 mg $1^{-1}$ of CODcr and 200-310 mg $1^{-1}$ of nitrogen, this process achieved a high quality effluent of less than 30 mgCOD $liter^{-1}$ and 50 mgN $liter^{-1}$. The removal rate of organics was above 98% at a loading rate larger than 2.5 kgCOD $m^{-3}$$d^{-1}$. When the internal recycle from the oxic to the anoxic reactor changed room 2n to 600% rout the influent flow rate, the nitrogen removal rate increased from about 70 to 90% at a loading rate of 0.4 kgT-N m-s d-1. The initial increase of transmembrane pressure (TMP) was observed after a 4-month operation while maintaining the flux and MLSS concentration at 7-9 1 $m^2$ $h^{-1}$ and 6,000-14,000 mg $1^{-1}$, respectively. The TMP could be maintained below 15 cmHg for an 8-month operation. The chemical cleaning with an acid followed by an immersion in an alkali solution gave better cleaning result with the membrane operated for 10 month rather than that only by an alkali immersion.

  • PDF

A Study on the Organic Waterwater Treatment Using of Agitating Mixer Biofilm Reactor (Agitating mixer를 이용한 생물막공법에서 유기성 폐수처리에 관한 연구)

  • Lee, Sang-Soo;Kim, Sung-Sun;Tak, Sung-Je;Jung, Kun-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.3
    • /
    • pp.107-115
    • /
    • 1999
  • The general objectives of this study are to develop a new biofilm reactor equipped with agitating mixer and to evaluated the treatment efficiency of the reactor. The experimental tests were conducted to estimate the oxygen transfer rate of agitating mixer system. Results are as follows. 1. The oxygen transfer coefficient, KLa, was $8.94hr{-1}$ and $7.50hr{-1}$ at 500rpm and 250rpm of agitating mixer speed, respectively. When the agitating mixer was used in the biofilm reactor, 22.5% and 18.8% of oxygen transfer rates were increased at 500rpm and 250rpm, respectively. 2. The removal rate of BOD and CODcr was decreased by 5.0% when the agitating mixer speed was varied from low (250rpm) to high level (500rpm). 3. The concentration of attached biomass had a difference of 5.0% to 7.3%, whereas that of suspended biomass had a difference of about 15.0%, depending upon variation of the agitating mixer speed.

  • PDF

Unit Mass Estimation and Analysis from Textile Spinning/Weaving Manufacturing Facility Nearby Nakdong River Basin (낙동강 수계에서 제사방적제조 업체에 대한 공정별 원단위산정 및 분석)

  • Lee, Hongshin;Son, Gontae;Gu, Jungeun;Konboonraksa T.;Lee, Hongtae;Lee, Seunghwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.5
    • /
    • pp.541-550
    • /
    • 2008
  • In this investigative study, the unit mass discharge for the major water quality parameters such as flowrate, SS, BOD, CODmn, CODcr, TN, TP from textile spinning/weaving industry nearby Nakdong river basin was estimated. To represent the respective industries, three companies from hundreds of textile spinning/weaving industries located in Nakdong river basin was carefully selected based on its manufacturing goods, flowrate and location for the estimation of unit mass discharge based on unit operation and process. There was a drastic decrease of unit mass discharge estimation between influents and effluents of water quality parameters, which represents the removal capacity of wastewater treatment plant. With the advent of new regulation on the imposed payment proportional to the total amount of pollutants discharge into the water body, the concept of cleaner production technology should be employed in the unit operation/process in wastewater treatment plant as well as textile manufacturing procedure to minimize the levy on the pollutants discharge. Unit mass discharge estimations of unit process (estimated in this study) in major water quality parameters (SS, BOD, COD, TN and TP) based on land were similar to those of composite process (estimated by National Institute of Environmental Research). But the unit mass discharge estimations of unit process in BOD and CODmn based on total sale were much higher than those of composite one while in SS, TN and TP similar to each other. For the detailed estimation of the imposed payment, unit mass estimation based on unit process should be further emphasized.

The Effect of Reduction of Contaminants and Odor according to the Additives in the Anaerobic Maturation Process of Piggery Slurry (양돈장 분뇨의 혐기성 부숙 과정에서 첨가제에 따른 오염물질 및 악취 저감 효과)

  • Kang Kyung-Ho;Kam Sang-Kyu;Hu Chul-Goo;Lee Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.15 no.2
    • /
    • pp.169-175
    • /
    • 2006
  • The changes of contaminants and odor corresponding to anaerobic maturation process of piggery slurry were investigated by applying the additives, such as different kinds of complex microorganism products and deodorants containing microorganism activating agents. The pHs during 20-day anaerobic maturation were operated stably without great change regardless of the additives, although they were rather lower in the case that the additives were contained than the case that they were not contained. The effects of removing CODcr, $NH_3-N$, T-N, and T-S in case that the additives were not contained, were not so great during the 20-day operation and so it would be difficult to remove the organic materials and nitrogen ingredients simply with anaerobic maturation process. However, in case of anaerobic maturation process that the additives were contained, their average removal rates were improved with the values of $49\%,\;63.5\%,\;48.5\%,\;and\;30.7\%$ for above each of items, even if the 20-day of short-term maturation period was applied. Especial1y, odor intensity with the additives was lowered continuously during the operation period and it had more than two times of lowering effect compared to that without those.

A Study on Cost-effective Treatment of Wastewater and Odor Reduction for Southeast Asian Market Entry

  • Jung, Min-Jae;Kim, Yong-Do;Kwon, Lee-Seung;Lee, Woo-Sic;Kwon, Woo-Taeg
    • The Journal of Industrial Distribution & Business
    • /
    • v.9 no.12
    • /
    • pp.23-29
    • /
    • 2018
  • Purpose - The purpose of this study is to apply a cost effective ultrasonic odor reduction method that generated micro-bubbles using ejector to the Southeast Asian wastewater market. Research design, data, and methodology - A leather maker located in Ansan-city, Gyunggi-do, South Korea was sampled from the collection tank to select experimental materials. Experimental setup consisted of circulating water tank-air ejector-ultrasonic device, and circulating wastewater. Sample analysis was performed by CODcr, T-N, T-P, and turbidity by the National Environmental Science Institute. Results - Experimental results show that it is most effective in removing odors when the frequency range of ultrasonic wave is 60~80 Khz and the output is 200 W. It showed that the concentration of complex odor dropped from a maximum of 14,422 times to a minimum of 120 times. Also, analysis of ammonia and hydrogen sulfide in specific odor substances has shown that they were reduced from 1.5 ppm to 0.4 ppm and from 0.6 ppm to 0.1 ppm, respectively. Conclusions - It is possible to shorten more than 12 hours in the treatment of micro-organisms. It can be seen that the processing time of odor after ultrasonic treatment in the pre-treatment facility is reduced by 25% when compared to the resultant micro-organisms after the chemical treatment, that is, the time of the bio-treatment of micro-organisms. Based on the results, it was confirmed that the pre-treatment method using the ultrasonic and the air ejector device of the experiment shows the effect of reducing the water pollutants and odor more effectively in a relatively short time than the conventional advanced oxidation method.

A Study on Distribution of the Contaminated Sediments in Lake Paldang (팔당호의 오염퇴적물 분포 조사)

  • Oh, Hyeon-Ju;Hong, Jong-Youb;Lee, Sang-Deuk;Chung, Moon-Jo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1295-1305
    • /
    • 2000
  • Status of the contaminated sediments in Lake Paldang was investigated. Sediment samples were taken at 34 points and analyzed in terms of ignition loss, CODer, total P and total N. The contamination level did not show any significant variation with depth of the sediments, which indicated the contaminants were recalcitrant. The type of P in the sediment was analyzed, and the sum of adsorbed P and NAI-P, that can be re-solubilized under the reductive condition, was found to be 20-30% of the total P. From the analysis of the water quality change along with the flowing path, it would be concluded that the effect of the sediments on the water quality is insignificant yet in Lake Paldang. However, long term analysis covering at least four seasons should be continued in order to get a more reliable conclusion. A depth profile map of the sediment in Lake Paldang was provided.

  • PDF

Automatic Control Of Dissolved Oxygen In Activated Sludge Aeration Tank

  • Park, Kwang-Soo;Heo, Nam-Hyo;Lee, Hae-Goon;Han, Gee-Baek;Kim, Chang-Won
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.3 no.2
    • /
    • pp.113-119
    • /
    • 1999
  • The quality of the effluent from an activated sludge aeration tank can deteriorate when the substrate removal rate decreases due to an abrupt reduction in the DO concentration, which is affected by such operating conditions as the loading rate, temperature, wastewater composition, and so on. In this research, a DO control system that includes a PI (proportional-integral) controller/Hiraoka controller was developed and applied to a pilot-scale activated sludge process, then its acceptability was estimated. The applicability of the respiration rate to DO control was also estimated. The respiration rate indicated a variety of input organic loading rates, which is the main disturbance to the DO concentration in an aeration tank. When the influent concentration incrementally decreased and increased between CODcr 1,000 mg/l and 100 mg/l, the control system with a PI controller exhibited a good llperformance-the average DO concentrations were 2.00$\pm$0.14 mg/l and 1.88$\pm$0.15 mg/l (set value was 2.0 mg/l), respectively, and the settling time was just 10 minites. When the control system was operated for 4 days, the DO concentration was 1.99$\pm$0.18 mg/l and 32.6% of the air flowrate was saved. However, the fluctuations in the respiration rates and air flowrates were severe, which could be harmful to the stability of the biomass and mechanical stability of the blower. A possible approach to solve this problem may be the simultaneous control of the loading rate and DO concentration.

  • PDF

Removal of Nitrogen in Seafood Processing Wastewater Using High-rate Anaerobic Process and Nitritation-denitritation (고율 혐기성 공정과 아질산-아탈질을 연계한 수산물가공폐수의 질소제거)

  • Choi, Yong-Bum;Kang, Dong-Gu;Park, Sang-Sung;Eum, Ki-Hyun;Rim, Jay-Myung;Kwon, Jae-Hyouk
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.4
    • /
    • pp.315-322
    • /
    • 2011
  • Objectives: Organic matter and nitrogen were removed using the EGSB process, a high-rate anaerobic process, in combination with a nitritation-denitritation process, in order to ensure the stable treatment of seafood processing wastewater. Methods: The upflow velocity of an EGGS reactor was operated at 10 m/hr for maximal organics removal efficiency. For removal of nitrogen from seafood processing wastewater a nitritation-denitriation process was applied Results: The efficiency of the EGSB process showed that it has an 80% or more organic matter (CODcr) removal efficiency with an HRT of six hours or more at influent loadings of 17.34 kgCOD/$m^3$/day or less. The methane product for TCODcr removal was 0.23-0.38 $m^3CH_4$/kgCODrem., which was similar to the theoretical generation of STP-state methane, 0.35 $m^3CH_4$/kgTCODrem. In the nitritation-denitritation process, the nitritation conversion rate to $NH_4^+$-N concentration was 82% to 87%, 72% to 81% and 64% to 69% when HRT was 24 hr, 21 hr and 18 hr, respectively. In the denitritation process, the ratio of SCOD consumption to NOx-N removal ranged from 2.347 to 2.587. It was 2.472 on average. Conclusions: The optimal HRT for stable processing of seafood processing wastewater is six hours or more. The ratio of nitrite to total NOx-N was 82% to 96%, which indicates that nitrite accounts for the largest portion of the product.