• Title/Summary/Keyword: CODE V

Search Result 735, Processing Time 0.025 seconds

Exploring Smartphone-Based Indoor Navigation: A QR Code Assistance-Based Approach

  • Chirakkal, Vinjohn V;Park, Myungchul;Han, Dong Seog
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.3
    • /
    • pp.173-182
    • /
    • 2015
  • A real-time, Indoor navigation systems utilize ultra-wide band (UWB), radio-frequency identification (RFID) and received signal strength (RSS) techniques that encompass WiFi, FM, mobile communications, and other similar technologies. These systems typically require surplus infrastructure for their implementation, which results in significantly increased costs and complexity. Therefore, as a solution to reduce the level of cost and complexity, an inertial measurement unit (IMU) and quick response (QR) codes are utilized in this paper to facilitate navigation with the assistance of a smartphone. The QR code helps to compensate for errors caused by the pedestrian dead reckoning (PDR) algorithm, thereby providing more accurate localization. The proposed algorithm having IMU in conjunction with QR code shows an accuracy of 0.64 m which is higher than existing indoor navigation techniques.

An Evaluation of Operator's Action Time for Core Cooling Recovery Operation in Nuclear Power Plant (원자력발전소의 노심냉각회복 조치에 대한 운전원 조치시간 평가)

  • Bae, Yeon-Kyoung
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.229-234
    • /
    • 2012
  • Operator's action time is evaluated from MAAP4 analysis used in conventional probabilistic safety assessment(PSA) of a nuclear power plant. MAAP4 code which was developed for severe accident analysis is too conservative to perform a realistic PSA. A best-estimate code such as RELAP5/MOD3, MARS has been used to reduce the conservatism of thermal hydraulic analysis. In this study, operator's action time of core cooling recovery operation is evaluated by using the MARS code, which its Fussell-Vessely(F-V) value was evaluated as highly important in a small break loss of coolant(SBLOCA) event and loss of component cooling water(LOCCW) event in previous PSA. The main conclusions were elicited : (1) MARS analysis provides larger time window for operator's action time than MAAP4 analysis and gives the more realistic time window in PSA (2) Sufficient operator's action time can reduce human error probability and core damage frequency in PSA.

A Phase-Locked Loop with Embedded Analog-to-Digital Converter for Digital Control

  • Cha, Soo-Ho;Jeong, Chun-Seok;Yoo, Chang-Sik
    • ETRI Journal
    • /
    • v.29 no.4
    • /
    • pp.463-469
    • /
    • 2007
  • A phase-locked loop (PLL) is described which is operable from 0.4 GHz to 1.2 GHz. The PLL has basically the same architecture as the conventional analog PLL except the locking information is stored as digital code. An analog-to-digital converter is embedded in the PLL, converting the analog loop filter output to digital code. Because the locking information is stored as digital code, the PLL can be turned off during power-down mode while avoiding long wake-up time. The PLL implemented in a 0.18 ${\mu}m$ CMOS process occupies 0.35 $mm^2$ active area. From a 1.8 V supply, it consumes 59 mW and 984 ${\mu}W$ during the normal and power-down modes, respectively. The measured rms jitter of the output clock is 16.8 ps at 1.2 GHz.

  • PDF

A Study on the Characteristics of Vertical Motions due to Changes of Submerged Shape in the Multi-Purpose Small Floating Body (다목적 소형 부유시설의 몰수부 형상변화에 따른 파랑중 수직운동 특성에 관한 연구)

  • OH, Yu-Na;KIM, Sang-Won;LEE, Gyoung-Woo;HAN, Seung-Jae;KIM, In-chul
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.4
    • /
    • pp.1024-1030
    • /
    • 2016
  • This study gives the vertical motion analysis due to changes in Submerged shape of Multi-Purpose Small Floating Body in irregular waves using the commercial code(MAXSURF v.20) based on the Panel method. To verify the commercial code prior to the analysis, we guarantees the reliability of this paper's results using the commercial code by comparing with the results of experimental results on Catamaran. The anlysis conditions are ITTC wave spectrum, each encounter angle. Finally, we analyze the result of ship's response spectra for vertical motions.

The Effects on Horizontal Web Reinforcements for Reinforced High Strength Concrete Deep Beams (춤이 깊은 고강도 철근콘크리트 보의 수평전단철근 효과에 관한 연구)

  • 신성우;성열영;안종문;이광수;박무용;김형준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.337-344
    • /
    • 1996
  • Reinforced concrete deep beams with conpressive strengths in the range of 500kg/$\textrm{cm}^3$~750kg/$\textrm{cm}^3$ were tested under two-point loding. All the beams were singly reinforced with main steel percent $\rho$=1.29% and with nominal percentage of vertical shear reinflrcements $\rho_v$=0.26%. According to shear-span to depth ratio a/d. The beams were tested for four horizontal shear reinforcement ratio $\rho_h$, ranging from$\rho_h$=0.0 to $\rho_h$=0.53. The results indicate that the horizontal shear reinforcements of beams have an effect on failure load and on ductile behavior of deep beams. The test results are compared with predictions based on the current ACI Building Code. The computated reports in the paper will have designers assured for design of high strength concrete deep beam. Though ACI Code is relatively conservative and tend to non-economical, ACI Code has the merit that is easy to use.

  • PDF

Numerical Analysis of Anode Sheath Structure Shift in an Anode-layer Type Hall Thruster

  • Yokota, Shigeru;Komurasaki, Kimiya;Arakawa, Yoshihiro
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.602-605
    • /
    • 2008
  • The anode sheath structure in the hollow anode of an anode-layer type Hall thruster was numerically computed using a fully kinetic 2D3V Particle-in-Cell and Direct Simulation Monte Carlo(PIC-DSMC) code. By treating both ions and electrons as particles, anode surface region, which is electrically non-neutral, was analyzed. In order to analyze in detail, the calculation code was parallelized using Message Passing Interface (MPI). The code successfully simulated the discharge current oscillation. In the low magnetic induction case, ion sheath appears in the anode surface because ionization is enough to maintain the plasma occurs in the anode hollow. As the magnetic induction increases, main ionization region move to outside of the anode. At the same time, anode sheath voltage decreases. In the high magnetic induction case, electron sheath appears on the anode surface periodically because the ionization occurs mainly in the discharge channel. This anode sheath condition shift can be explained using the simple sheath model.

  • PDF

Determination of energy resolution for a NaI(Tl) detector modeled with FLUKA code

  • Demir, Nilgun;Kuluozturk, Zehra Nur
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3759-3763
    • /
    • 2021
  • In this study, 3" × 3" NaI(Tl) detector, which is widely used in gamma spectroscopy, was modeled with FLUKA code, and calculations required to determine the detector's energy resolution were reported. Photon beams with isotropic distribution with 59, 81, 302, 356, 511, 662, 835, 1173, 1275, and 1332 keV energy were used as radiation sources. The photon pulse height distribution of the NaI(Tl) without influence of its energy resolution obtained with FLUKA code has been converted into a real NaI(Tl) response function, using the necessary conversion process. The photon pulse height distribution simulated in the conversion process was analyzed using the ROOT data analysis framework. The statistical errors of the simulated data were found in the range of 0.2-1.1%. When the results, obtained with FLUKA and ROOT, are compared with the literature data, it is seen that the results are in good agreement with them. Thus, the applicability of this procedure has been demonstrated for the other energy values mentioned.

Comparative study of CFD and 3D thermal-hydraulic system codes in predicting natural convection and thermal stratification phenomena in an experimental facility

  • Audrius Grazevicius;Anis Bousbia-Salah
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1555-1562
    • /
    • 2023
  • Natural circulation phenomena have been nowadays largely revisited aiming to investigate the performances of passive safety systems in carrying-out heat removal under accidental conditions. For this purpose, assessment studies using CFD (Computational Fluid Dynamics) and also 3D thermal-hydraulic system codes are considered at different levels of the design and safety demonstration issues. However, these tools have not being extensively validated for specific natural circulation flow regimes involving flow mixing, temperature stratification, flow recirculation and instabilities. In the present study, an experimental test case based on a small-scale pool test rig experiment performed by Korea Atomic Energy Research Institute, is considered for code-to-code and code-to-experimental data comparison. The test simulation is carried out using the FLUENT and the 3D thermal-hydraulic system CATHARE-2 codes. The objective is to evaluate and compare their prediction capabilities with respect to the test conditions of the experiment. It was observed that, notwithstanding their numerical and modelling differences, similar agreement results are obtained. Nevertheless, additional investigations efforts are still needed for a better representation of the considered phenomena.

Optimization of airborne alpha beta detection system modeling using MCNP simulation

  • Sung, Si Hyeong;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.841-845
    • /
    • 2020
  • An airborne alpha beta detection system using passivated implanted planar silicon (PIPS) detector was modeled with the MCNP6 code and its resolution and detection efficiency were analyzed. Simulation of the resolution performed using the Gaussian energy broadening (GEB) function showed that the full width at half maximum (FWHM) of 35.214 keV for alpha particles was within 34-38 KeV, which is the FWHM range of the actual detector, and the FWHM of 15.1 keV for beta particles was constructed with a similar model to 17 keV, which is the FWHM range of an actual detector. In addition, the detection efficiency and the resolution were simulated according to the distance between the detector and the air filter. When the distance was decreased to 0.2 cm from 0.8 cm, the efficiency of the alpha and beta particles detection decreased from 5.33% to 4.89% and from 5.64% to 4.27%, respectively, and the FWHM of the alpha and beta particles improved from 40.9 KeV to 29.84 keV and 25.76 keV-13.27 keV, respectively.

A Study on the Silicon Damages and Ultra-Low Energy Boron Ion Implantation using Classical Molecular Dynamics Simulation (고전 분자 동 역학 시뮬레이션을 이용한 실리콘 격자 손상과 극 저 에너지 붕소 이온 주입에 관한 연구)

  • 강정원;강유석;손명식;변기량;황호정
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.12
    • /
    • pp.30-40
    • /
    • 1998
  • We have calculated ultra-low energy silicon-self ion implantations and silicon damages through classical molecular dynamics simulation using empirical potentials. We tested whether the recently developed Environment-Dependent Interatomic Potential(EDIP) was suitable for ultra low energy ion implantation simulation, and found that point defects formation energies were in good agreement with other theoretical calculations, but the calculated vacancy migration energy was overestimated. Most of the damages that are produced by collision cascades are concentrated into amorphous-like pockets. Also, We upgraded MDRANGE code for silicon ion implantation process simulation. We simulated ultra-low energy boron ion implantation, 200eV, 500eV, and 1000eV respectively, and calculated boron profiles with silicon substrate temperature and tilt angle. We investigated that below 1000eV, channeling effect must be considered.

  • PDF