• Title/Summary/Keyword: CODE V

Search Result 735, Processing Time 0.023 seconds

A LDPC Decoder for DVB-S2 Standard Supporting Multiple Code Rates (DVB-S2 기반에서 다양한 부호화 율을 지원하는 LCPC 복호기)

  • Ryu, Hye-Jin;Lee, Jong-Yeol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.2
    • /
    • pp.118-124
    • /
    • 2008
  • For forward error correction, DVB-S2, which is the digital video broadcasting forward error coding and modulation standard for satellite television, uses a system based the concatenation of BCH with LDPC inner coding. In DVB-S2 the LDPC codes are defined for 11 different code rates, which means that a DVB-S2 LDPC decoder should support multiple code rates. Seven of the 11 code rates, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, and 9/10, are regular and the rest four code rates, 1/4, 1/3, 2/5, and 1/2, are irregular. In this paper we propose a flexible decoder for the regular LDPC codes. We combined the partially parallel decoding architecture that has the advantages in the chip size, the memory efficiency, and the processing rate with Benes network to implement a DVB-S2 LDPC decoder that can support multiple code rates with a block size of 64,800 and can configure the interconnection between the variable nodes and the check nodes according to the parity-check matrix. The proposed decoder runs correctly at the frequency of 200MHz enabling 193.2Mbps decoding throughput. The area of the proposed decoder is $16.261m^2$ and the power dissipation is 198mW at a power supply voltage of 1.5V.

포커스-e제품 - (주)모던하이테크

  • 한국광학기기협회
    • The Optical Journal
    • /
    • s.147
    • /
    • pp.54-54
    • /
    • 2013
  • (주)모던하이테크가 광학 설계 프로그램인 CODE V$^{(R)}$ Rsoft$^{(R)}$ LightTools$^{(R)}$를 9월 중에 업그레이드 출시할 예정이다. 모던하이테크는 고객들이 프로그램을 구매하기 전에 한 달간 제품을 체험해 볼 수 있는 무료 평가판 및 유상 기술지원 서비스인 '프리미엄 패키지'도 함께 제공하고 있다.

  • PDF

포커스e기업 - (주)모던하이테크

  • 한국광학기기협회
    • The Optical Journal
    • /
    • s.150
    • /
    • pp.42-43
    • /
    • 2014
  • CODE V$^{(R)}$, Light Tools S/W 및 광학측정 업체인 (주)모던하이테크(대표이사 김명중)는 3월 17일(월)부터 19일(수)까지 사흘간 (주) 모던하이테크 세미나실(서울시 강남구 영동대로 511 무역센터 트레이드타워 1002호)에서 미국 ORA 광학 설계 프로그램 기술 매니저가 직접 내한하여 광학설계 특별 교육 세미나를 성공적으로 개최했다.

  • PDF

ZOOM-IN - (주)싸이펨 민제홍 대표이사 취임 인터뷰

  • 한국광학기기산업협회
    • The Optical Journal
    • /
    • s.177
    • /
    • pp.28-29
    • /
    • 2020
  • 미국 Synopsys의 광학 설계 분석 소프트웨어의 국내 판매와 기술지원, 교육, 광학설계 컨설팅 서비스와 기하광학에서 파동광학까지 폭넓게 아우르는며, LightTools(조명), CODE V(렌즈), LucidShape(자동차 조명), RSoft(나노 사이즈 광학구조) 네 가지 분야 소프트웨어와 광학 설계 솔루션을 보유한 광학 전문기업 (주)싸이펨이 지난 1월 민제홍 대표이사가 새로 취임하며 변화를 꾀하고 있다.

  • PDF

Performance Analysis of the Optimal Turbo Coded V-BLAST technique in Adaptive Modulation System (적응 변조 시스템에서 최적의 터보 부호화된 V-BLAST 기법의 성능 분석)

  • Lee, Kyung-Hwan;Choi, Kwang-Wook;Ryoo, Sang-Jin;Kang, Min-Goo;Hong, Dae-Ki;You, Cheol-Woo;Hwang, In-Tae;Kim, Cheol-Sung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.2
    • /
    • pp.385-391
    • /
    • 2007
  • In this paper, we propose and observe the Adaptive Modulation system with optimal Turbo Coded V-BLAST (Vertical-Bell-lab Layered Space-Time) technique that is applied the extrinsic information from MAP (Maximum A Posteriori) Decoder with Iterative Decoding to use as a priori probability in two decoding procedures of V-BLAST: ordering and slicing. Also, comparing with the Adaptive Modulation system using conventional Turbo Coded V-BLAST technique that is simply combined V-BLAST with Turbo Coding scheme, we observe how much throughput performance has been improved. As a result of simulation, in the Adaptive Modulation systems with several Turbo Coded V-BLAST techniques, the optimal Turbo Coded V-BLAST technique has higher throughput gain than the conventional Turbo Coded V-BLAST technique. Especially, the results show that the proposed scheme achieves the gain of 1.5 dB SNR compared to the conventional system at 2.5 Mbps throughput.

Development of Site Classification System and Modification of Design Response Spectra considering Geotechnical Site Characteristics in Korea (I) - Problem Statements of the Current Seismic Design Code (국내 지반특성에 적합한 지반분류 방법 및 설계응답스펙트럼 개선에 대한 연구 (I) - 국내 내진설계기준의 문제점 분석)

  • Yoon, Jong-Ku;Kim, Dong-Soo;Bang, Eun-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.2 s.48
    • /
    • pp.39-50
    • /
    • 2006
  • Site response analyses were peformed based on equivalent linear technique using the shear wave velocity profiles of 162 sites collected around the Korean Peninsula. The she characteristics, particularly the shear wave velocities and the depth to bedrock, are compared to those in the western United States. The site coefficients of short period $(F_a)$ and the long period $(F_v)$ obtained from this study were significantly different compared to 1997 Uniform Building Code (1997 UBC). $F_a$ underestimated the motion in shot period ranges and $F_v$ overestimated the motion in mid period ranges in Korean seismic guideline. It is found that the existing Korean seismic design code were is required to be modified considering geological site conditions in Korea for the reliable estimation of sue amplification. Problems of the current seismic design code were dicussed in this paper and the development of site classification method and modification of desing response spectra were discussed in the companion papers(II-Development of Site Classification System and III-Modification of Dosing Response Specra).

Evaluation of electron dose distribution obtained from ADAC Pinnacle system against measurement and Monte Carlo method for breast patients

  • Lee, S.;Lee, R.;Park, D.;S. Suh
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.82-82
    • /
    • 2003
  • Introduction: With the development of dose calculation algorithms for electron beams, 3D RTP systerns are available for electron beam dose distribution commercially. However, no studies evaluated the accuracy of dose calculation with ADAC Pinnacle system for electron beams. So, the accuracy of the ADAC system is investigated by comparing electron dose distributions from ADAC system against the BEAMnrc/DOSXYZnrc. Methods: A total of 33 breast cancer patients treated with 6, 9, and 12MeV electrons in our institution was selected for this study. The first part of this study is to compare the dose distributions of measurement, TPS and the BEAMnrc/DOSXYZnrc code in flat water phantom at gantry zero position and for a 10 ${\times}$ 10 $\textrm{cm}^2$ field. The second part is to evaluate the monitor unit obtained from measurement and TPS. Adding actual breast patient's irregular blocks to the first part, monitor units to deliver 100 cGy to the dose maximum (dmax) were calculated from measurement and 3D RTP system. In addition, the dose distributions using blocks were compared between TPS and the BEAMnrc/DOSXYZnrc code. Finally, the effects of tissue inhomogeneities were studied by comparing dose distributions from Pinnacle and Monte Carlo method on CT data sets. Results: The dose distributions calculated using water phantom by the TPS and the BEAMnrc/ DOSXYZnrc code agreed well with measured data within 2% of the maximum dose. The maximum differences of monitor unit between measured and Pinnacle TPS in flat water phantom at gantry zero position were 4% for 6 MeV and 2% for 9 and 12 MeV electrons. In real-patient cases, comparison of depth doses and lateral dose profiles calculated by the Pinnacle TPS, with BEAMnrc/DOSXYZnrc code has generally shown good agreement with relative difference less than +/-3%. Discussion: For comparisons of real-patient cases, the maximum differences between the TPS and BEAMnrc/DOSXYZnrc on CT data were 10%. These discrepancies were due in part to the inaccurate dose calculation of the TPS, so that it needs to be improved properly. Conclusions: On the basis of the results presented in this study, we can conclude that the ADAC Pinnacle system for electron beams is capable of giving results absolutely comparable to those of a Monte Carlo calculation.

  • PDF

Development of Pressure Drop Model for the Compartment in Reactor Containment (격납용기내 구분방사이의 압력 강하 계산모델 개발)

  • Park, Cheol;Song, In-ho;Lee, Un-Chul
    • Nuclear Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.183-193
    • /
    • 1986
  • Full scale HDR containment experiment series pointed out that the previous containment analysis models have a number of shortcomings. One of them is on the calculational model of short term (0~2sec) pressure difference. The pressure differences between subcompartments are dependent on the flow rate, fluid density, head loss coefficient, and flow area ratio. It, however, is not known that any of them is largely attributed to the disagreement of pressure difference between the measured and the calculated values. In this study, the head loss coefficients are expressed with another form to improve the analytic model. The pressure and the pressure difference are evaluated by using COMPARE code with new correlation, and the results show better agreements with experimental values for V.42 test, but overestimate the measured values for V, 43 and underestimate for V.44.

  • PDF

The Electronic and Thermoelectric Properties of Si1-xVx Alloys from First Principles

  • Ramanathan, Amall Ahmed;Khalifeh, Jamil Mahmoud
    • Applied Microscopy
    • /
    • v.47 no.3
    • /
    • pp.105-109
    • /
    • 2017
  • The effect of temperature and vanadium metal concentration on the electronic and thermoelectric properties of Si in the diamond cubic structure has been investigated using a combination of density functional theory simulations and the semi classical Boltzmann's theory. The BotzTrap code within the constant relaxation time approximation has been used to obtain the Seebeck coefficient and other transport properties of interest for alloys of the structure $Si_{1-x}V_x$, where x is 0, 0.125, 0.25, 0.375, and 0.5. The thermoelectric properties have been extracted for a temperature range of 300 K to 1,000 K. The general trend with V atom substitution for Si causes the Seeback coefficient to increase and the thermal conductivity to decrease for the various alloys. The optimum values are for $Si_5V_3$ and $Si_4V_4$ alloys for charge carrier concentrations of $10^{21}cm^{-3}$ in the mid temperature range of 500~800 K. This is a very desirable effect for a promising thermoelectric and the figure of merit ZT approaches 0.2 at 600 K for the p-type $Si_5V_3$ alloy.

Experimental and Simulated Efficiency of a HPGe Detector in the Energy Range of $0.06{\sim}11$ MeV

  • Park Chang Su;Sun Gwang Min;Choi H.D.
    • Nuclear Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.234-242
    • /
    • 2003
  • The full energy peak efficiency of a hyper pure germanium (HPGe) detector was calibrated in a wide energy range from 0.06 to 11 MeV. Both the experimental technique and the Monte Carlo method were used for the efficiency calibration. The measurement was performed using the standard radioisotopes in the low energy region of $60{\sim}1408$ keV, which was further extended up to 11 MeV by using the $^{14}N(n,r)\;and\;^{35}Cl(n,r)$ reactions. The GEANT Monte Carlo code was used for efficiency calculation. The calculated efficiency had the same dependency on the r-ray energy with the measurement, and the discrepancy between the calculation and the measurement was minimized by fine-tuning of the detector geometry. From the calculated result, the efficiency curve of the HPGe detector was reliably determined particularly in the high energy region above several MeV, where the number of measured efficiency points is relatively small despite the wide energy region. The calculated efficiency agreed with the measurement within about $7\%$. In addition to the efficiency calculation, the origin of the local minimum near 600 keV on the efficiency curve was analyzed as a general characteristics of a HPGe detector.