• Title/Summary/Keyword: CODE

Search Result 18,043, Processing Time 0.042 seconds

Secretory Expression System of Xylose Reductase (GRE3) for Optimal Production of Xylitol (Xylitol 생산에 최적화된 xylose reductase (GRE3)의 분비발현 시스템)

  • Jung, Hoe-Myung;Kim, Jae-Woon;Kim, Yeon-Hee
    • Journal of Life Science
    • /
    • v.26 no.12
    • /
    • pp.1376-1382
    • /
    • 2016
  • Xylitol is widely used in the food and medical industry. It is produced by the reduction of xylose (lignocellulosic biomass) in the Saccharomyces cerevisiae strain, which is considered genetically safe. In this study, the expression system of the GRE3 (YHR104W) gene that encodes xylose reductase was constructed to efficiently produce xylitol in the S. cerevisiae strain, and the secretory production of xylose reductase was investigated. To select a suitable promoter for the expression of the GRE3 gene, pGMF-GRE3 and pAMF-GRE3 plasmid with GAL10 promoter and ADH1 promoter, respectively, were constructed. The mating factor ${\alpha}$ ($MF{\alpha}$) signal sequence was also connected to each promoter for secretory production. Each plasmid was transformed into S. cerevisiae $SEY2102{\Delta}trp1$, and $SEY2102{\Delta}trp1$/pGMF- GRE3 and $SEY2102{\Delta}trp1$/pAMF-GRE3 transformants were selected. In the $SEY2102{\Delta}trp1$/pGMF-GRE3 strain, the total activity of xylose reductase reached 0.34 unit/mg-protein when NADPH was used as a cofactor; this activity was 1.5 fold higher than that in $SEY2102{\Delta}trp1$/pAMF-GRE3 with ADH1 as the promoter. The secretion efficiency was 91% in both strains, indicating that most of the recombinant xylose reductase was efficiently secreted in the extracellular fraction. In a baffled flask culture of the $SEY2102{\Delta}trp1$/pGMF-GRE3 strain, 12.1 g/l of xylitol was produced from 20 g/l of xylose, and ~83% of the consumed xylose was reduced to xylitol.

Monitoring of Malachite Green in Freshwater Fish using LC-MS/MS (LC-MS/MS를 이용한 담수 어류 중 말라카이트 그린 분석)

  • Choi, Hee-jin;Yuk, Dong-Hyun;Park, Young-Ae;Jung, Bo-Kyeng;Hong, Mi-Sun;Yoon, Yong-Tae;Yi, Hye-Jin;Kim, Youn-Cheon;Park, Sung-Kyu;Kim, Moo-Sang;Jung, Kweon
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.1
    • /
    • pp.15-20
    • /
    • 2016
  • Malachite green was measured in 200 freshwater fish collected from local markets in Seoul using HPLC-DAD and LC-MS/MS. LC-MS/MS method was validated by linearity, accuracy, precision and limits of detection and quantification according to the CODEX's recommendation and HPLC-DAD method was applied according to the Food Code. Malachite green levels above the quantification limit of the LC-MS/MS were determined 18.5% (37) but just 1 fish was shown to contain malachite green by HPLC-DAD. Of 83 domestic fish, 21 fish were detected malachite green (25.3%). Of 117 fish from China, just 16 fish were detected malachite green (13.4%). In detection rate by species carp (35.0%), Crucian carp (30.4%), cat fish (28.0%), Korean bull head (23.8%), snake head (20.0%), eel (10.5%) and loach (7.8%) were in order. Especially, fish collected at summer were shown to contain malachite green frequently; the detection rate was 54.8%.

Evaluation on Microbiological Contamination Level of Raw Beef from Retail Markets in Seoul, Korea (서울지역 식육판매점의 우육에 대한 미생물학적 오염도 평가)

  • Ko, Eun-Kyung;Heo, Eun Jeong;Kim, Young Jo;Park, Hyun Jung;Wi, Seong-Hwan;Moon, Jin San
    • Food Science of Animal Resources
    • /
    • v.33 no.3
    • /
    • pp.403-410
    • /
    • 2013
  • This study was performed to evaluate the microbiological contamination level of raw beef from retail markets in Seoul, Korea. The sampling and laboratory test were performed according to the procedure of "Standard for processing and ingredients specification of livestock product" and "Korean food code". Enterotoxin of Staphylococcus aureus isolates were detected using VIDAS$^{(R)}$ and PCR-based methods. Listeria monocytogenes serotyping and genotyping were carried out using Listeria antisera and L. monocytogenes Fingerprinting kit, respectively. A total of 48 samples were collected from 16 retail markets (butcher's shop: 5, department store: 6, supermarket: 5) in 2011. The level of total bacteria counts in the butcher's shop, department store and supermarket were $4.4{\times}10^3$ CFU/g, $3.9{\times}10^5$ CFU/g and $1.0{\times}10^4$ CFU/g, respectively. The concentrations of Escherichia coli of these three retail markets were $6.4{\times}10$ CFU/g, 7.6 CFU/g and $2.0{\times}10$ CFU/g, respectively. Salmonella species was not detected on all samples. However, S. aureus was isolated in the 3 samples (6.25%) from each type of three retail markets. L. monocytogenes was isolated in the 4 samples (8.3%) from department stores. The level of contamination of these foodborne bacteria was less than 100 CFU/g. The enterotoxin-encoding genes of S. aureus isolates were sea, seh, sei and sep gene. The gene similarity of L. monocytogenes isolated from two retail markets by Rep-PCR showed 57.8-98.1% and 68.1-98.1%, respectively. These results suggest that the HACCP guideline for environmental control in slaughterhouse and retail markets should be provided to prevent cross contamination and manage foodborne pathogens such as L. monocytogenes and S. aureus.

Measurement and Monte Carlo Simulation of 6 MV X-rays for Small Radiation Fields (선형가속기의 6 MV X-선에 대한 소형 조사면 측정과 몬테 카를로 시뮬레이션)

  • Jeong Dong Hyeok;Lee Jeong Ok;Kang Jeong Ku;Kim Soo Kon;Kim Seung Kon;Moon Sun Rock
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.195-202
    • /
    • 1998
  • Purpose : In order to obtain basic data for treatment plan in radiosurgery, we measured small fields of 6 MV X-rays and compared the measured data with our Monte Carlo simulations for the small fields. Materials and Methods : The small fields of 1.0, 2.0 and 3.0 cm in diameter were used in this study. Percentage depth dose (PDD) and beam Profiles of those fields were measured and calculated. A small semiconductor detector, water phantoms, and a remote control system were used for the measurement Monte Carlo simulations were Performed using the EGS4 code with the input data prepared for the energy distribution of 6 MV X-rays, beam divergence, circular fields and the geometry of the water phantoms. Results : In the case of PDD values, the calculated values were lower than the measured values for all fields and depths, with the differences being 0.3 to 5.7% at the depths of 20 to 20.0 cm and 0.0 to 8.9% at the surface regions. As a result of the analysis of beam profiles for all field sizes at a depth of loom in water phantom, the measured 90% dose widths were in good agreement with the calculated values, however, the calculated Penumbra radii were 0.1 cm shorter than measured values. Conclusion : The measured PDDs and beam profiles agreement with the Monte Carlo calculations approximately. However, it is different when it comes to calculations in the area of phantom surface and penumbra because the Monte Carlo calculations were performed under the simplified geometries. Therefore, we have to study how to include the actual geometries and more precise data for the field area in Monte Carlo calculations. The Monte Carlo calculations will be used as a useful tool for the very complicated conditions in measurement and verification.

  • PDF

Preliminary Post-closure Safety Assessment of Disposal Options for Disused Sealed Radioactive Source (폐밀봉선원 처분방식별 폐쇄후 예비안전성평가)

  • Lee, Seunghee;Kim, Juyoul;Kim, Sukhoon
    • Economic and Environmental Geology
    • /
    • v.49 no.4
    • /
    • pp.301-314
    • /
    • 2016
  • Disused Sealed Radioactive Sources (DSRSs) are stored temporally in the centralized storage facility of Korea Radioactive Waste Agency (KORAD) and planned to be disposed in the low- and intermediate-level radioactive waste (LILW) disposal facility in Gyeongju city. In this study, preliminary post-closure safety assessment was performed for DSRSs in order to draw up an optimum disposal plan. Two types of disposal options were considered, i.e. engineered vault type disposal and rock cavern type disposal which were planned to be constructed and operated respectively in LILW disposal facility in Gyeongju city. Assessment end-point was individual effective dose of critical group and calculated by using GoldSim code. In normal scenario, the maximum dose was estimated to be approximately $1{\times}10^{-7}mSv/yr$ for both disposal options. It meant that both options had sufficient safety margin when compared with regulatory limit (0.1 mSv/yr). Otherwise, in well scenario, the maximum dose exceeded regulatory limit of 1 mSv/yr in engineered vault type disposal and the exposure dose was mainly contributed by $^{226}Ra$, $^{210}Pb$ (daughter nuclide of $^{226}Ra$) and $^{237}Np$ (daughter nuclide of $^{241}Am$). For rock cavern type disposal, even though the peak dose satisfied regulatory limit, the exposure doses by $^{14}C$ and $^{237}Np$ were relatively high above 10% of regulatory limit. Therefore, it is necessary to exclude $^{14}C$, $^{226}Ra$ and $^{241}Am$ for two type of disposal options and additional management such as long-term storage and development of disposal container for those radionuclides should be performed before permanent disposal for conservative safety and security.

Monitoring of Heavy Metal Content in Alcoholic Beverages (국내 유통 주류 중 중금속 실태조사)

  • No, Ki-Mi;Kang, Kyung-Mo;Baek, Seung-Lim;Choi, Hoon;Park, Sung-Kug;Kim, Dong-Sul
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.1
    • /
    • pp.24-29
    • /
    • 2010
  • This study was conducted to estimate the contents of heavy metals including lead, cadmium, arsenic and total mercury in alcoholic beverages in Korea. Concentration of Hg was analyzed by gold amalgamation method, using mercury analyzer, while concentration of Pb, Cd and As was analyzed by ICP-MS. Concentration (${\mu}g/kg$) of heavy metal in fermented liquors were; for Pb $9.9\;{\pm}\;8.4$(0~38.0), Cd $5.8\;{\pm}\;4.9$(0~5.4), As $28.6\;{\pm}\;19.4$(1~96.4), Hg $0.7\;{\pm}\;1.2$(0~10.6). Concentration (${\mu}g/kg$) of distilled liquors were ; for Pb $4.4\;{\pm}\;5.7$(0~29.3), Cd $2.0\;{\pm}\;2.5$(0~10.3), As $12.0\;{\pm}\;17.0$(0~95.6), Hg $0.2\;{\pm}\;0.3$(0~2.3). Concentration(${\mu}g/kg$ of other liquous were ; for Pb $7.5\;{\pm}\;5.1$(0~13.7), Cd $5.8\;{\pm}\;3.9$(0.6~11.2), As $25.2\;{\pm}\;39.0$(0.5~103.3), Hg $0.3\;{\pm}\;0.1$(0.1~0.5). The present study showed that difference of the amount of constituent in a same category of food are not affect to the content of heavy metals among them. The residual levels of takju, yakju, sake, beer, fruit wine, soju, whiskey, brandy, general distilled liquor, liquor, other liquors are within the maximum levels, prescribed by Korea food code. It is given that heavy metal exposure of Pb, Cd, As, Hg from consumption of alcoholic beverages (takju, yakju, sake, beer, fruit wine, soju, whiskey, brandy, general distilled liquor, liquor, other liquors) are less than 0.03%, 0.06%, 0.01%, 0.01% (mean) in provisional tolerable weekly intake (PTWI) respectively, indicated by FAO/WHO.

The Design of Wireless Underwater Telephone -Analysis of Underwater Background Noise for Wireless Underwater Telephone Design - (수중 무선 전화기의 설계 - 수중무선전화기 설계를 위한 수중소음분석을 중심으로-)

  • 박문갑;윤갑동;김석제;윤종락
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.4
    • /
    • pp.302-307
    • /
    • 2001
  • The underwater background noise measured in Geoje and Tongyoung diving fishing ground from May to December, 2000 and analyzed to get optimum carrier frequency and transmitter power level for underwater wireless telephone design. The results obtained are summarized as follows: 1. At the Geoje and Tongyoung diving fishing ground, the lowest ambient noise band was 25~30kHz with 57dB and 52dB re 1$\mu$Pa, respectively. 2. At the Geoje and Tongyoung diving fishing ground, the lowest noise band during fishing activity was 67dB and 62dB re 1$\mu$Pa, respectively. 3. At the Geoje diving fishing ground, the noise of water jetter which is a digging machine for subbottom shells was 102dB re 1$\mu$Pa. 4. Considering the design parameters of underwater wireless telephone, it is found that the optimum carrier frequency band is around 30kHz and the transmitter source level should be at least 131dB re 1$\mu$Pa for 500m range telephone.

  • PDF

A Road Luminance Measurement Application based on Android (안드로이드 기반의 도로 밝기 측정 어플리케이션 구현)

  • Choi, Young-Hwan;Kim, Hongrae;Hong, Min
    • Journal of Internet Computing and Services
    • /
    • v.16 no.2
    • /
    • pp.49-55
    • /
    • 2015
  • According to the statistics of traffic accidents over recent 5 years, traffic accidents during the night times happened more than the day times. There are various causes to occur traffic accidents and the one of the major causes is inappropriate or missing street lights that make driver's sight confused and causes the traffic accidents. In this paper, with smartphones, we designed and implemented a lane luminance measurement application which stores the information of driver's location, driving, and lane luminance into database in real time to figure out the inappropriate street light facilities and the area that does not have any street lights. This application is implemented under Native C/C++ environment using android NDK and it improves the operation speed than code written in Java or other languages. To measure the luminance of road, the input image with RGB color space is converted to image with YCbCr color space and Y value returns the luminance of road. The application detects the road lane and calculates the road lane luminance into the database sever. Also this application receives the road video image using smart phone's camera and improves the computational cost by allocating the ROI(Region of interest) of input images. The ROI of image is converted to Grayscale image and then applied the canny edge detector to extract the outline of lanes. After that, we applied hough line transform method to achieve the candidated lane group. The both sides of lane is selected by lane detection algorithm that utilizes the gradient of candidated lanes. When the both lanes of road are detected, we set up a triangle area with a height 20 pixels down from intersection of lanes and the luminance of road is estimated from this triangle area. Y value is calculated from the extracted each R, G, B value of pixels in the triangle. The average Y value of pixels is ranged between from 0 to 100 value to inform a luminance of road and each pixel values are represented with color between black and green. We store car location using smartphone's GPS sensor into the database server after analyzing the road lane video image with luminance of road about 60 meters ahead by wireless communication every 10 minutes. We expect that those collected road luminance information can warn drivers about safe driving or effectively improve the renovation plans of road luminance management.

Monitoring of Pesticide Residues in Dried Medicinal Plants used for Food Materials (건조 식품원료 약용식물의 잔류농약 모니터링)

  • Yu, In-Sil;Park, Sung-Kyu;Choi, Young-Hee;Seoung, Hyun-Jung;Jung, Hee-Jung;Han, Sung-Hee;Lee, Young-Ju;Kim, Yun-Hee;Kim, Kyung-Sig;Han, Ki-Young;Chae, Young-Zoo
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.3
    • /
    • pp.224-232
    • /
    • 2012
  • This study was performed to investigate the pesticide residue of commercial medicinal plants used for food materials in the Seoul area. Multi class pesticide multiresidue methods in Korea Food Code was used to analyze 100 pesticides. Analyzed samples were 261 cases(domestic 201, imported 60), detection rate was 19.2%(domestic 20.9%, imports 13.3%). 17 pesticides were detected in fruit(chinese matrimony vine, jujube, rubus coreanus, japanese cornlian cherry, schizandra, tangerine peel), and root(cnidium, licorice, astragalus). Pesticide over Maximum Residue Limits were detected in jujube, cnidium. Frequently detected pesticides were cypermethrin, chlorpyrifos, cyhalothrin, fenvalerate, bifenthrin. More than 50% of the sample were detected two or more pesticides at the same time. Because of the variety and increase of pesticide detection in medicinal roots and fruits, continued monitoring and safety management is required.

Studies on the Hand Hygiene Practices of Food-Service Workers: A Comparison of Fast Food Restaurant Workers and Full-service Restaurant Workers (조리종사자의 손 위생관리에 관한 연구 - 패스트푸드점 및 일반음식점 종사자의 비교 -)

  • Kim, Jong-Gyu;Park, Jeong-Yeong;Kim, Joong-Soon
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.3
    • /
    • pp.215-223
    • /
    • 2012
  • This study was performed to investigate hygienic behavior of food workers on the awareness of hand-washing, and the microbial load of their hands. This study focused on the comparison of fast food restaurant workers and full-service restaurant workers. A questionnaire survey and microbiological analysis were carried out for thirty fast food restaurant workers and forty full-service restaurant workers. Samples for microbiological analysis were collected through the glove-juice method from the hands of the food workers, and were analyzed for the presence of aerobic plate counts, total coliforms, fecal coliforms, Escherichia coli, Staphylococcus aureus, and Salmonella spp. Microbiological analysis was done according to the Food Code of Korea. In the survey, significant differences (p < 0.05) were found between the fast food restaurant workers and full-service restaurant workers in the use of hand washing tools and method of turning off water. More full-service restaurant workers responded to wash their hands after touching face, hair, or clothes; after handling raw food materials, and more fast food restaurant workers periodically (p < 0.05). Aerobic plate counts were higher in fast food restaurant workers while total coliforms were higher in full-service restaurant workers (p < 0.05). No remarkable difference was found between the two groups in the load of fecal coliforms, E. coli, S. aureus, and Salmonella spp. Poor hand hygiene practices were indicated by the positive results for E. coli, S. aureus, and Salmonella spp. on the hands of some food workers in both groups. The findings of this study emphasize the need for strict adherence to hand hygiene compliance among the food workers.