• 제목/요약/키워드: COD removal

검색결과 1,129건 처리시간 0.028초

유입흐름 변경 및 전응집 기반 이단응집 제어 적용 MBR을 통한 총인처리 개선 연구 (Enhanced total phosphorus removal using a novel membrane bioreactor by sequentially alternating the inflow and by applying a two-stage coagulation control based on pre-coagulation)

  • 차재환;신경숙;박승국;신정훈;김병군
    • 상하수도학회지
    • /
    • 제31권1호
    • /
    • pp.103-114
    • /
    • 2017
  • A membrane bioreactor by sequentially alternating the inflow and by applying a two-stage coagulation control based on pre-coagulation was evaluated in terms of phosphorus removal efficiency and cost-savings. The MBR consisted of two identical alternative reaction tanks, followed by aerobic, anoxic and membrane tanks, where the wastewater and the internal return sludge alternatively flowed into each alternative reaction tank at every 2 hours. In the batch-operated alternative reaction tank, the initial concentration of nitrate rapidly decreased from 2.3 to 0.4 mg/L for only 20 minutes after stopping the inflow, followed by substantial release of phosphorus up to 4 mg/L under anaerobic condition. Jar test showed that the minimum alum doses to reduce the initial $PO_4$-P below 0.2 mg/L were 2 and 9 mol-Al/mol-P in the wastewater and the activated sludge from the membrane tank, respectively. It implies that a pre-coagulation in influent is more cost-efficient for phosphorus removal than the coagulation in the bioreactor. On the result of NUR test, there were little difference in terms of denitrification rate and contents of readily biodegradable COD between raw wastewater and pre-coagulated wastewater. When adding alum into the aerobic tank, alum doses above 26 mg/L as $Al_2O_3$ caused inhibitory effects on ammonia oxidation. Using the two-stage coagulation control based on pre-coagulation, the P concentration in the MBR effluent was kept below 0.2 mg/L with the alum of 2.7 mg/L as $Al_2O_3$, which was much lower than 5.1~7.4 mg/L as $Al_2O_3$ required for typical wastewater treatment plants. During the long-term operation of MBR, there was no change of the TMP increase rate before and after alum addition.

도금폐수처리를 위한 입상활성탄 유동 메디아 적용 유동상 멤브레인 여과기술의 적용가능성 평가에 관한 연구 (Study on Feasibility of Fluidized Bed Membrane Reactor with Granular Activated Carbon Particles as Fluidized Media to Treat Metal-plating Wastewater)

  • 장수민;권대은;김정환
    • 멤브레인
    • /
    • 제28권4호
    • /
    • pp.252-259
    • /
    • 2018
  • 실 산성 도금폐수를 입상활성탄(GAC)이 유동메디아로 첨가된 유동상 멤브레인 반응기를 이용하여 처리하였다. GAC 유동조건에서 적용 투과플럭스에 대해 시간에 따른 흡입압의 증가는 관찰되지 않았다. 폐수의 중성 pH에서 파울링 속도는 산성 조건에 비해 GAC 유동조건에서 크게 감소하였다. 해당 폐수의 용액 pH 증가는 입자크기의 증가를 가져왔고 이는 멤브레인 표면에서 상대적으로 성긴 구조의 케이크층 형성을 야기시켰다. 유동상 멤브레인 반응기에서 GAC 유동 하에 95%이상의 COD 제거율이 관찰되었으며 총부유물질은 거의 완벽하게 제거되었다. 실 도금폐수의 pH에서, 유동상 멤브레인 반응기의 구리 및 크롬의 제거는 거의 관찰 되지 않았다. 그러나 pH를 중성으로 증가 시켰을 시 구리와 크롬의 제거율은 각각 99%와 94%까지 증가를 하였다. 적용해 준 pH에 상관 없이, 시안의 경우 95% 이상의 제거율을 달성하였다. 이는 유기물과 시안 착물 형성으로 인해 유동상 멤브레인 반응기 내 GAC의 강한 흡착으로 제거된 것으로 사료된다.

RBC를 이용한 양어장수 암모니아 제거 (Ammonia Removal by using RBC in Recirculating Aquaculture System)

  • 김병진;임성일;서근학
    • 한국수산과학회지
    • /
    • 제31권5호
    • /
    • pp.622-630
    • /
    • 1998
  • 본 연구에서는 양식장에서 많이 이용되고 있는 RBC 반응기를 모의 순환 여과식 양어장에 적용하여 어류에 유해한 암모니아성 질소의 사육조 내의 농도를 낮게 유지할 수 있는 운전인자를 도출하고자 하였다. 본 시스템에서 사용된 회전원판 반응기의 최적 원판회전수는 4 rpm으로 가장 안정 적으로 생물막이 유지되고 가장 높은 제거율을 나타내었다. 수리학적 체류시간의 증가에 따라 회전원판반응기의 암모니아성 질소 제거율은 증가하여 40분의 수리학적 체류시간에서 $95.3\%$로 매우 높은 값을 나타내었으나 사육조의 암모니아성 질소의 농도는 $2.33 g/m^3$으로 가장 높은 값을 나타내었으며 20분의 수리학적 체류시간에서는 암모니아성 질소의 제거율은 $62.2\%$로 실험조건 중 가장 낮았으나 사육조의 암모니아성 질소농도는 $1.03 g/m^3$으로 가장 낮게 나타났다. 본 시스템에서 순환수의 유량 $Q_1$와 보충수의 유량 $Q_s$의 비인 D의 변화에 따른 암모니아성 질소 제거율의 변화는 다음의 2차선형 회귀 곡선으로 잘 표현되었으며 이를 사육조의 물질수지식에 적용하여 수리학적 체류시간의 변화에 따른 사육조 내의 암모니아성 질소의 농도 변화를 추정해본 결과 실험치와 거의 일치하였다. $$R=-6.1158\times10^{-7}D^2+1.4629\times10^{-5}D+0.9643 (r^2=0.9982)$$ 수학적 해석의 결과 사육조의 암모니아성 질소 발생량이 $45g/m^3$ rearing tank/day이고 보충수의 양이 사육조부피의 $10\%$일 경우 최적 순환비 ($D_{OPT}$)는 733으로 반응기 기준의 수리학적 체류시간은 9.82분이었으며 이때의 사육조의 암모니아성 질소의 농도는 0.95g $TAN/m^3$으로 유지할 수 있는 것으로 나타났다. COD의 제거율은 수리학적 체류시간이 9.5분일 경우 $18\%$를 나타내었으며 수리학적 체류시간이 증가함에 따라 제거율도 선형적으로 증가하여 40분의 체류시간에서는 $35\%$의 제거율을 나타내었다.

  • PDF

한천-아크릴아마이드 미생물 고정화법에 의한 폐수 중 폴리비닐알콜의 분해 (Degradation of Polyvinyl Alcohol in Dye-Processing Wastewater by Agar-Acrylamide Microbial Immobilization Method)

  • 김재훈;김정목조무환
    • KSBB Journal
    • /
    • 제10권3호
    • /
    • pp.241-248
    • /
    • 1995
  • 염색가공 폐수 중 난분해성 물질이 PYA를 처리 하기 위하여, 한천-acrylamide를 이용한 bead를 제 조한 후 air-lift 반응기에서 연속실험을 행하였다. 합성폐수의 PYA놓도가 $3,100mg/\ell$. 체류시간 24hr일 때 유출수의 농도는 $4500mg/\ell$ 이며, 제거효율은 85% 이상을 나타내었다. 실제 호발폐수의 경우 PYA 및 COD농도가 $3,253mg/\ell$, $4,500mg/\ell$일 때, 체류시간 24hr에서 유출수의 농도는 $840mg/\ell, 480mg/\ell$이며, 제거효 율은 81.3%와 85.2%로 각각 나타났다. bead의 지름이 lmm일 때는 내부의 미생물 성장 이 양호하였으나 bead의 지름이 2mm일 때는 기질 과 산소전달저항에 의하여 반지름의 48% 이상은 미 생물의 성장이 저해를 받았다. 고정화 반응기에서 전체 기질 제거속도 중 bead 내 고정화 cell의 제거 분율은 평균 70%로 나타났다. 현탁 반응기에서 희석율 $0.083hr^{-1}$ 이상에서는 기질 이용속도가 감소하였으나 고정화 반응기에서는 희석율 $0.125hr^{-1}$까지 거의 선형척으로 증가하였다. PYA 제거속도식에서 포화상수 $K_s=6.60(g PVA/\ell)$와 최대 비기질 이용속도 k=0.175(g PVA/g cell.hr)를 얻었다.

  • PDF

NoMix toilet 에서 발생하는 부산물을 이용한 수용액내 (준)중금속 제거 특성 및 가능성 연구 (A Study of the Removal Characteristics of Heavy Metal(loid)s using by Product from NoMix Toilet and its Characterization)

  • 심재홍;임정묵;김진원;김해원;오병택
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제21권1호
    • /
    • pp.28-39
    • /
    • 2016
  • Struvite (MgNH4PO4 ⋅ 6H2O) and hydroxyapatite (HAP, Ca10(PO4)6(OH)2) precipitation in urine-separating toilets (NoMix toilets) causes severe maintenance problems and also reduce the phosphate and calcium content. Application of urine separating technique and extraction of by-products from human urine is a cost effective technique in waste water treatment. In this study, we extract urine calcite from human urine by batch scale method, using urease producing microbes to trigger the precipitation and calcite formation process. Extracted urine calcite (calcining at 800℃) is a potential adsorbent for removal of heavy metal(loid)s like (Cd2+, Cu2+, Ni2+, Pb2+, Zn2+ and As3+) along with additional leaching analysis of total nitrogen (T-N), phosphate (T-P) and chemical oxygen demand (COD). The transformations of calcite during synthesis were confirm by characterization using XRD, SEM-EDAX and FT-IR techniques. In additional, the phosphate leaching potential and adsorbate (nitrate) efficiency in aqueous solution was investigated using the calcinedurine calcite. The results indicate that the calcite was effectively remove heavy metal(loid)s lead up to 96.8%. In addition, the adsorption capacity (qe) of calcite was calculated and it was found to be 203.64 Pb, 110.96 Cd, 96.02 Zn, 104.2 As, 149.54 Cu and 162.68 Ni mg/g, respectively. Hence, we suggest that the calcite obtain from the human urine will be a suitable absorbent for heavy metal(loid)s removal from aqueous solution.

순산소의 MBR(Membrane Bio Reactor) 공정 적용을 통한 음식물류 폐기물 혐기성소화 유출수 처리 평가 (Evaluation of pure oxygen with MBR(Membrane Bio Reactor) process for anaerobic digester effluent treatment from food waste)

  • 박세용;김문일;박성혁
    • 유기물자원화
    • /
    • 제29권3호
    • /
    • pp.5-16
    • /
    • 2021
  • 본 연구에서는 MBR 공정 내 폭기조에서 순산소 용해와 일반 공기 폭기의 효율에 대한 비교·평가를 통해 순산소의 MBR 공정 적용성에 대해 평가 하였다. 순산소 장치에 의한 유기물 및 암모니아 산화 여부에 대해 평가하였으며, 실폐수(음식물류 폐기물의 혐기성소화 유출수) 적용 과포화산소용해 효율 평가를 진행하였다. 순산소용해와 일반공기폭기 방법의 SCOD, 암모니아 제거율과 속도는 비슷하였다. 하지만, 순산소 용해에 의한 미생물 수율이 일반공기폭기법에 의한 미생물 수율보다 약 0.03 g MLSS-produced/g SCOD-removed 낮아 잉여슬러지 처리 비용이 감소될 수 있을 것이라 판단된다. 음식물류 폐기물의 혐기성 소화 유출수의 고농도 유기물 (4,000 mg/L) 및 암모니아 (1,400 mg/L)의 제거율을 순산소용해와 일반공기폭기법을 비교한 결과, 순산소 용해기가 일반공기폭기법에 비해 유기물 제거율이 약 13% 가량 더 높게 평가되었다. 또한, MLSS의 경우 일반공기폭기법이 순산소장치에 비해 0.3배가량 높았다. 이는, 순산소장치의 경우 폭기조 내에 용존산소가 충분히 유지, 공급되기 때문에 슬러지 자산화가 고도로 진행된 결과로 판단되었다. 따라서, 고농도 유기물을 함유한 폐수 처리를 위한 방법으로는 기존에 많이 사용되었던 일반공기폭기법보다 순산소장치를 활용하는 것이 경제적인 면에서 더 유리할 것으로 판단되었다.

Biofilter 공정에서 유입 C/N비와 DO가 지하수의 질산성 질소제거에 미치는 영향 (Effect of Influent C/N Ratio and DO on Denitrification of Nitrate Polluted Groundwater in a Biofilter Process)

  • 이무재;박상민;박노백;전항배;김공수
    • 대한환경공학회지
    • /
    • 제28권4호
    • /
    • pp.355-361
    • /
    • 2006
  • 고정상 생물여과지(biofiiter)에서 유입 C/N(COD/Nitrate)비와 용존산소(DO) 농도가 지하수로부터 질산성 질소를 제거하는데 미치는 영향을 관찰하였다. 유입 C/N비 10과 4.0에서 30 mg/L로 유입된 질산성 질소는 생물학적 탈질반응에 의해 완전히 제거되었다. 반면, 유입 C/N비 2.0에서는 전자공여체가 부족하였기 때문에 5.0 mg/L의 질산성 질소가 유출되었다. 게다가, 유입 C/N비가 2로 감소함에 따라 5.0 mg/L에 달하는 아질산성 질소가 발생하였다. 유입 C/N비 5에서 DO 농도의 증가는 탈질반응을 저해하였으며, 질산성 질소제거효율을 감소시켰다. 아황산나트륨($Na_2SO_3$)을 이용하여 유입 DO농도를 조절할 경우, 0.3 mg/L의 낮은 DO에도 불구하고 유출수 중 3.6 mg/L의 아질산성 질소가 잔류하였다. 반면, 질소가스를 이용하여 DO농도를 0.3 mg/L로 조절한 경우, 유입된 질산성 질소는 완전히 제거되었으며, 아질산성 질소는 검출되지 않았다. 생물여과지에서 유입된 질산성 질소를 제거하는데 소비된 유기물은 $3.0{\sim}3.5gSCOD/g{NO_3}^--N$의 범위이었으나, DO 농도가 5.5 mg/L로 증가함에 따라 소비된 그 양은 증가하였다. 높은 DO 농도 및 낮은 유입 C/N비와 함께 아황산나트륨을 이용한 DO 농도 조절은 생물학적 탈질반응에 영향을 주었으며, 질산성 질소제거효율을 감소시키고 아질산성 질소가 축적되었다.

빗물 재활용을 위한 모래 정화층의 폐색특성을 고려한 비점오염원 제거 예측 모델 연구 (A Prediction Model for Removal of Non-point Source Pollutant Considering Clogging Effect of Sand Filter Layers for Rainwater Recycling)

  • 안재윤;이동섭;한신인;정영욱;최항석
    • 한국지반공학회논문집
    • /
    • 제30권6호
    • /
    • pp.23-39
    • /
    • 2014
  • 인공 빗물 저류조는 도심지에 설치되어 빗물의 재활용이 가능하도록 한 친환경 우수유출 저감시설이나 지면에 내린 빗물을 직접 이용하기 위해서는 도심지의 초기강우에 포함된 고농도의 비점오염원을 정화할 수 있는 시설이 수반되어야 한다. 본 논문에서는 인공 빗물 저류조에 적용할 수 있는 비점오염원 정화시설로서 경제성과 정화효율이 우수한 토양여과시설을 채택하여 실제 비점오염물질에 대한 모래 정화층의 입도분포에 따른 폐색특성을 연구하였다. 이를 위해 일련의 실내 챔버시험을 수행하고 폐색이론에 의한 비점오염원 제거 예측 모델을 제시하였다. 우선, 실내 챔버시험은 미세입자로 구성된 점토와 서울시내 도로에서 채집된 실제 비점오염원으로 제조된 인공 오염수를 이용하여, 5종류의 다양한 입도로 구성된 모래 정화층을 대상으로 수행되었다. 실내 챔버시험에서는 모래 정화층에 유입 및 유출된 인공 오염수의 TSS(총 부유물질)와 COD(화학적 산소 요구량)를 측정하여 오염입자의 크기에 따른 모래 정화층의 정화효율을 평가하였고, 정화층 간극에 폐색되는 비점오염입자의 누적무게를 산출하였다. 다음으로, 모래 정화층의 폐색특성을 이론적으로 규명하기 위해 비점오염원 제거 예측모델을 모래 정화층의 입도와 구성에 따른 특성과 투수계수 및 간극률의 변화 조건을 고려하여 제시하였다. 실내 챔버시험과 예측 모델로부터 산정한 모래 정화층에 폐색된 입자의 누적무게를 비교하여 폐색특성 지표인 Lumped parameter ${\theta}$를 추정하였으며, ${\theta}$는 모래 정화층에 폐색되는 오염입자의 양에 큰 영향을 주는 것을 확인하였다. 모래 정화층의 폐색 예측모델로부터 현장 인공 빗물 저류조에 적합한 최적의 비점오염 제거 시스템으로 유효입경 1.49mm(상부)와 유효입경 0.93mm(하부)의 모래로 구성된 이중 정화층을 제시하였다.

여재순환장치를 이용한 돈분뇨 슬러리의 오염물질 및 악취제거 효율 (Removal Efficiency of Water Pollutants and Malodor of Pig Slurry using Biofiltration System)

  • 최동윤;곽정훈;정광화;박규현;허미영;김재환;강희설;전경호;박치호;정종원
    • 한국축산시설환경학회지
    • /
    • 제15권3호
    • /
    • pp.217-224
    • /
    • 2009
  • 1. 여재순환장치는 사각프레임 형태로 설계 제작하였으며, 고액분리장치, 여재순환구 동축 및 날개, 압축공기 분사장치와 여재 및 액비배출장치로 구성되었다. 2. 고액분리한 돈슬러리를 장치에 투입하여 가동을 한 결과, 톱밥을 여재로 이용했을 때 $BOD_5$는 52.8, $COD_{Mn}$ 57.3, SS 26.9, T-N 71.0, T-P 30.9% 수준으로 감소하는 것으로 나타났으며, 왕겨를 이용한 경우에도 톱밥과 비슷한 경향을 나타내었다. 3. 5회까지 순환시켜 침출된 액비의 비료 성분은 질소의 경우, 원슬러리에 비해 2/3 수준, 인산은 1/3 수준으로 줄어드는 경향을 나타냈으나, 칼리는 거의 변하지 않는 것으로 나타났다. 4. 침출액비의 악취 (암모니아, 황화수소)는 초기에 비해 상당한 수준으로 저감되었으며, 톱밥이 왕겨에 비해 비교적 효과가 높은 것으로 나타났다. 5. 여재순환장치 가동 전후의 돈슬러리내 미생물을 조사한 결과, 총세균과 부숙에 관여하는 것으로 추정되는 바실러스균은 증가하는 경향이었으며, 살모네라균은 급격하게 감소하는 경향을 보였다. 6. 이상과 같은 결과로 볼 때, 악취저감 균질액비 생산장치를 이용하여 액비를 생산할 경우, 오염물질, 악취물질, 병원성세균 등이 감소하고, 부숙관여 유용미생물이 증가한 악취저감 균질액비 생산이 가능한 것으로 판단된다.

  • PDF

수질정화를 위한 다기능 인공식물섬의 개발과 적용 (Development and Application of Multi-Functional Floating Wetland Island for Improving Water Quality)

  • 윤영한;임현만;김원재;정진홍;박재로
    • Ecology and Resilient Infrastructure
    • /
    • 제3권4호
    • /
    • pp.221-230
    • /
    • 2016
  • 유속이 낮은 정체수역에 대하여 부영양화에 의한 녹조발생을 미연에 방지하고 수질개선을 도모하기 위하여 기존 인공식물섬 운영기술에 다양한 요소기술을 도입한 다기능 인공식물섬을 개발하였고 개발기술에 대한 성능검증을 위하여 경기도에 소재하는 하천에서 여름철과 겨울철 동안에 모니터링 하였다. 본 연구의 다기능 인공식물섬은 수질정화 기능을 높이기 위해서 정수식물 기반의 식생여과 공정 위주의 일반 인공식물섬 기술에 미세기포 공정과 인공여재에 의한 인 흡착/여과 공정을 추가하여 운영하였다. 개발기술에 대한 계절에 따른 오염물질 (COD, T-P) 제거율 변화로부터 오염부하가 낮은 겨울철 (15.9%, 20.0%)보다는 부하가 높은 여름철 (40.9%, 45.7%)에 높은 처리효율을 갖는 것으로 나타났고 공정별 제거율 (SS, Chl-a)에서는 미세기포 공정은 여름철 (33.1%, 39.2%)에, 인 흡착/여과 인공여재 및 식생여과 공정은 겨울철 (76.5%, 59.5%)에 높은 제거효율을 갖는 것으로 분석되어 다기능 인공식물섬의 정화능은 계절별 변화 또는 오염부하 정도에 따라서 적용 기술별로 제거능을 나타내어 지속적인 모니터링이 필요할 것으로 사료되었다. 또한, 인공식물섬 주변의 생태변화 분석결과, 식물섬 저부에 미세기포의 공급으로 용존산소가 증가됨으로써 혐기화에 의한 물질환원 현상을 방지하고 수류순환을 유도하여 친환경적인 새로운 수생태계가 조성되는 것을 확인하였고 이러한 결과들을 통하여 다기능 인공식물섬에 의하여 정체수역의 수질이 개선되고 다양한 동식물의 성장으로 정체수역 저부의 물질순환이 개선될 수 있는 가능성을 확인하였다.