• 제목/요약/키워드: COD Removal

검색결과 1,132건 처리시간 0.024초

모래와 굴패각을 이용한 인공습지 오수처리장치 개발 (Development of Constructed Wetland using Sand and Oyster shell for Sewage Treatment)

  • 박현건;이춘식;이홍재;서동철;허종수
    • 한국물환경학회지
    • /
    • 제20권5호
    • /
    • pp.437-446
    • /
    • 2004
  • To develop sewage treatment apparatus by natural purification method, the sewage treatment plant that consisted of aerobic and anaerobic plot was constructed. And then, the effects of treatment conditions on the removal of pollutants in the relation to sewage loading, sewage injection method and season according to the pebble kind. Removal rate of BOD and COD according to the sewage loading in effluent were over 95 and 77%, respectively. Removal rate of nitrogen in treated water by aerobic plot and effluent using sand were about 22~40 and 49~75%, respectively. Those of effluent using sand 75%+ oyster shell 25% and sand 50%+ oyster shell 50% as filter media in comparison with using sand were about 7~25 and 16~23%, respectively. Removal rate of phosphorus in treated water by aerobic plot and effluent using sand as filter media were about 30~36 and 52~56%, respectively. Those of effluent using sand 75%+ oyster shell 25% and sand 50%+ oyster shell 50% in comparison with using sand as filter media were about 11~40 and 12~45%, respectively. Removal efficiency of BOD and COD according to the intermittent injection method of sewage were slightly decreased, but those of nitrogen and phosphorus were little varied in comparison with continuous injection method. Removal efficiency of BOD and COD in winter in comparison with the others were little varied, but those of nitrogen and phosphorus slightly decreased.

生物膜 電極反應機를 이용한 廚房廢水 처리 효과 (Effects of Domestic Wastewater Treatment used Biofilm-Electrode Reactor(BER))

  • Noh, Hyun-Woong;Yoon, Oh-Sub
    • 한국환경보건학회지
    • /
    • 제23권1호
    • /
    • pp.43-49
    • /
    • 1997
  • This study was aimed to estimate removal efficiency(%) of BER(Biofilm-Electrode Reactor) and A.S(Activated Sludge) treatments. When were analyzed COD$_{Cr}$, NH$_3$-N and T-P by current density and reaction time, the results were as follows : 1) In BER treatment, the removal efficiency of COD$_{Cr}$ in domestic wastewater was 79-86% when current density was 2.39 mA/dm$2$(15mA)-3.98 mA/dm$^2$(25mA) and reaction time was 48 hr. 2) Removal efficiency of NH$_3$-N was 71-73% when current density was 2.39-3.98 mA/dm$^2$ and reaction time 48 hr. 3) When the reaction time was 48 hr removal efficiency(%) of BER treatment for COD$_{Cr}$, NH$_3$-N and T-P were more excellent than A.S. treatment. And then we prospect that was because activated microorganism colonies attached in biofilm on surface of electrode pannel. Therefore, In order to derive BER treatment efficiency(%) should establish optimum conditions of pH, temp., reaction time, current density and biochemical and electrochemical states.

  • PDF

농업용수 수질개선을 위한 침강지의 수질정화 특성 (Water Purification Characteristics of Sedimentation Basin for Agricultural Water Quality Improvement)

  • 김형중;김동환
    • 한국관개배수논문집
    • /
    • 제21권1호
    • /
    • pp.55-63
    • /
    • 2014
  • A sedimentation basin for agricultural water quality improvement was researched to analyze the water quality purification characteristics. The sedimentation basin constructed at the inlet of Gamdon reservoir in Muan-gun, Jeollanam-do was selected as the research field of this study. The surface area of the sedimentation basin is $34,000m^2$, volume is $122,000m^3$, and hydraulic retention time is 0.3hr~7.3day. The average influent loading of SS was 156.6kg-SS/d, and the effluent loading was 67.5kg-SS/d with the average removal rate of 56.9%. The average influent loadings of BOD and COD were 33.0kg-BOD/d and 60.3kg-COD/d respectively, and the effluent loadings were 26.4kg-BOD/d and 48.6kg-COD/d with the average removal rate of 20.1% and 19.3% respectively. Therefore, the results of this study show that a sedimentation basin can purify SS and organic matters. The average influent loadings of T-N and T-P were 28.7kg-TN/d and 2.97kg-TP/d respectively, and the effluent loadings were 16.3kg-TN/d and 1.41kg-TP/d with the average removal rate of 43.0% and 52.6% respectively. In conclusion, the overall results of this study show that a sedimentation basin is a feasible alternative to purify organic matters and nutrients.

  • PDF

개질한 sericite를 이용한 염색공장 폐수처리 (Application of Modified Sericite for Dyeing Wastewater Treatment)

  • 최희정
    • 한국환경과학회지
    • /
    • 제24권9호
    • /
    • pp.1189-1197
    • /
    • 2015
  • The aim of this study was to investigate the nutrient removal using Mg-Sericite flocculant in the dyeing wastewater. Mg-Sericite flocculant was removed successfully > 98% of the Color, SS. COD and BOD in the dyeing wastewater at the following optimal Mg-Sericite dosage: 100 mg/L for Colour and SS, 300 mg/L for BOD and COD. The removal of TN and TP was obtained 92.00% with 50 mg/L and 87.80% with 100 mg/L Mg-Sericite dosage, respectively. These results was indicated that the amount of 0.79~1.31, 0.22~0.37, 0.5 and 0.16 mg/L Mg-Sericite was necessary for 1 mg/L removal BOD, COD, TN and TP, respectively. The biopolymer, Mg-Sericite, can be a promising flocculants due to its high efficiency and low dose requirements. In addition, Mg-Sericite does not contaminate treated wastewater, which can be recycled to reduce not only the cost and the demand for water but also the extra operational costs for reusing wastewater. This flocculation method is helpful to lower the wastewater treatment cost.

Treatment of Oily Wastewater with WPO and CWO

  • Han, Mei;Chen, Yihui;He, Fang;Yu, Li
    • 대한화학회지
    • /
    • 제58권1호
    • /
    • pp.68-71
    • /
    • 2014
  • Petroleum refining unavoidably generates large volumes of oily wastewater. The environmentally acceptable disposal of oily wastewater is a current challenge to the petroleum industry. Nowadays, more attentions have been focused on the treatment techniques of oily wastewater. Oily wastewater contained highly concentrated and toxic organic compounds. Wet peroxide oxidation (WPO) and catalytic wet oxidation (CWO) were applied to eliminate pollutants to examine the feasibility of the WPO/CWO of oily wastewater. The results indicated that more than 80% chemical oxygen demand (COD) removal from oily wastewater was achieved with CWO. Homogenous catalyst, $NaHCO_3$ and $Na_2CO_3$ and NaOH showed effective removal for pollutants in oily wastewater. Greater than 90% COD removal was achieved with WPO. It was concluded that WPO was a far more effective process for oily wastewater.

Treatment of Rice Mill Wastewater Using Continuous Electrocoagulation Technique: Optimization and Modelling

  • Karichappan, Thirugnanasambandham;Venkatachalam, Sivakumar;Jeganathan, Prakash Maran;Sengodan, Kandasamy
    • 대한화학회지
    • /
    • 제57권6호
    • /
    • pp.761-768
    • /
    • 2013
  • Removal of COD and TSS from rice mill wastewater was investigated using continuous electrocoagulation method (CEC). The electrical energy consumption (EEC) of the process was also examined in order to evaluate the economic viability. The Box-Behnken statistical experiment design (BBD) and response surface methodology (RSM) were used to investigate the effects of major operating variables. Initial pH, current density, electrode distance and flow rate were selected as independent variables in BBD while COD removal, TSS removal and EEC were considered as the response functions. The predicted values of responses obtained using the response function was in good agreement with the experimental data. Optimum operating conditions were found to be pH of 7, current density of 15 mA $cm^{-2}$, electrode distance of 5 cm and flow rate of 70 ml/min. Under these conditions, greater than 89% removal of COD and TSS were obtained with EEC value of 7 KWh.

The effectiveness of step feeding strategies in sequencing batch reactor for a single-stage deammonification of high strength ammonia wastewater

  • Choi, Wonyoung;Yu, Jaecheul;Kim, Jeongmi;Jeong, Soyeon;Direstiyani, Lucky Caesar;Lee, Taeho
    • Membrane and Water Treatment
    • /
    • 제11권1호
    • /
    • pp.79-85
    • /
    • 2020
  • A single-stage deammonification with a sequencing batch reactor (SBR) that simultaneous nitritation, anaerobic ammonia oxidation (anammox), and denitrification (SNAD) occur in one reactor has been widely applied for sidestream of wastewater treatment plant. For the stable and well-balanced SNAD, a feeding strategy of influent wastewater is one of the most important operating factors in the single-stage deammonification SBR. In this study, single-stage deammonification SBR (working volume 30L) was operated to treat a high-strength ammonium wastewater (1200 mg NH4+-N/L) with different feeding strategies (single feeding and nine-step feeding) under the condition without COD. Each cycle of the step feeding involved 6 sub-cycles consisted of aerobic and anoxic periods for partial nitritation (PN) and anammox, respectively. Contrary to unstable performance in the single feeding, the step feeding showed better deammonification performance (0.565 kg-N/m3/day). Under the condition with COD, however, the nitrogen removal rate (NRR) decreased to 0.403 kg-N/m3/day when the Nine-step feeding strategies had an additional denitrification period before sub-cycles for PN and anammox. The NRR was recovered to 0.518 kg-N/m3/day by introducing an enhanced multiple-step feeding strategy. The strategy had 50 cycles consisted of feed, denitrification, PN, and anammox, instead of repeated sub-cycles for PN and anammox. The multiple-step feeding strategy without sub-cycle showed the most stable and excellent deammonification performance: high nitrogen removal efficiency (98.6%), COD removal rate (0.131 kg-COD/m3/day), and COD removal efficiency (78.8%). This seemed to be caused by that the elimination of the sub-cycles might reduce COD oxidation during aerobic condition but increase the COD utilization for denitrification period. In addition, among various sensor values, the ORP pattern appeared to be applicable to monitor and control each reaction step for deammonification in the multiple-step feeding strategy without sub-cycle. Further study to optimize the number of multiple-step feeding is still needed but these results show that the multiple-step feeding strategy can contribute to a well-balanced SNAD for deammonification when treating high-strength ammonium wastewater with COD in the single-stage deammonification SBR.

Treatment and Reuse of Acrylic Wastewater using Membrane Separation System

  • Lee, Kwanghyun
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2004년도 Proceedings of the second conference of aseanian membrane society
    • /
    • pp.117-120
    • /
    • 2004
  • The separation characteristics were investigated with the variations of pressure and temperature using ultrafiltration and reverse osmosis membrane module sets composed of different membrane types and materials. TDS, T-N and COD removal efficiencies were not affected and low with the change of temperature and pressure in case of using UF modules contained in module set 1, 2, 3. TDS, T-N and COD removal efficiencies were very high in RO modules. The final water quality of acrylic wastewater was satisfied within the discharge limit value of plant wastewater. It was known that membrane module sets could be used for the reuse of wastewater.

  • PDF

Changes in BOD, COD, Chlorophyll-a and Solids in Aquaculture Effluent with Various Chemical Treatments

  • Park, Jeonghwan;Daniels, Harry V.
    • 한국해양생명과학회지
    • /
    • 제2권2호
    • /
    • pp.49-55
    • /
    • 2017
  • Four chemical treatments with hydrogen peroxide (H2O2), copper sulfate (CuSO4), potassium permanganate (KMnO4) and chlorine (Cl2) were applied to the effluent pond water of a hybrid striped bass saltwater recirculating aquaculture system to compare their oxidation power. Four chemicals were applied at concentrations of 0 (control), 1, 5, 10 and 20 mg/l. An additional concentration of 40 mg/l was included in the chlorine treatment. Water samples from four hybrid striped bass ponds were tested with KMnO4 and Cl2. H2O2 did not reduce any of BOD, COD and chlorophyll-a, and copper sulfate was only effective on chlorophyll-a for the effluent pond. Removal efficiencies for chlorophyll-a by copper sulfate were 19.2%, 37.5%, 54.2% and 74.1% dose-dependently. Potassium permanganate effectively removed the BOD, COD and chlorophyll-a. The COD removal rates in four fish ponds varied from 15.9% to 31.6% at the concentration of 10 mg/l. Interestingly, Cl2 did not reduce the BOD and COD at all, but the BOD and COD instead increased drastically with increasing the Cl2 concentration. The pond water with the highest initial BOD and COD values among the fish ponds tested increased by 350% in the BOD and 150% in the COD at 20 mg/l. Furthermore, Cl2 did not significantly reduce any types of solid matter in this study, while KMnO4 seemed to reduce some extent volatile dissolved solid in the fish pond.

염색산업단지 종합폐수처리용 재순환 통합시스템 (Recirculating Integrated System for the Treatment of Authentic Integrated-textile-dyeing Wastewater from Dyeing Industrial Complex)

  • 이은주;임광희
    • Korean Chemical Engineering Research
    • /
    • 제55권6호
    • /
    • pp.837-845
    • /
    • 2017
  • D염색공단의 폴리에스테르 알카리 감량폐수 및 호발폐수가 혼합된 실제 종합염색폐수를 처리하기 위하여 D염색공단의 종합폐수처리장 반송슬러지를 고정한 폐타이어담체를 충전한 재순환 유동상 바이오필터와 소성된 $TiO_2$ 코팅-glass bead를 광촉매담체로 적용한 UV/광촉매반응기를 결합한 재순환 통합시스템을 구축하여 운전하였다. 그 결과로서 재순환 통합시스템의 총 $COD_{cr}$ 제거율과 총 색도 제거율 추이는 각각 약 81% 및 55% 정도를 유지하였다. 이러한 재순환 통합시스템의 총 $COD_{cr}$ 및 총 색도 제거율의 제고효과는 각각 최대 약 7% 및 3%로 평가되었다. 재순환 통합시스템의 유동상 바이오필터 및 광촉매반응공정은 총 제거율에 대한 상대기여도로서 각각 총 $COD_{cr}$ 제거율의 약 94% 및 6%를 처리하고, 총 색도 제거율의 약 86% 및 14%를 처리하였다. 이와 같이 재순환 통합시스템의 광촉매반응공정에서는 총 제거율에 대한 색도 제거율의 상대기여도가 $COD_{cr}$ 제거율의 상대기여도보다 약 2.4배 정도 컸다. 따라서 본 연구의 재순환 통합시스템에서 광촉매반응공정은 $COD_{cr}$ 제거보다 아조결합과 같이 염료에서 색을 나타내는 화학결합을 깨는 역할에 더욱 효율성이 있었다. 또한 본 연구의 재순환 통합시스템에서 각 단위공정들의 $COD_{cr}$ 및 색도 제거율이, 재순환 통합시스템의 총 $COD_{cr}$ 및 색도 제거율에 미치는 영향에 대한 모델식과 대수적 상관관계를 구하고 분석하였다.