• Title/Summary/Keyword: COD Removal

Search Result 1,130, Processing Time 0.03 seconds

A Study on the Preparation of the Dimensionally Stable Anode(DSA) with High Generation Rate of Oxidants(II) (산화제 생성율이 높은 촉매성 산화물 전극(DSA)의 개발에 관한 연구(II))

  • Park, Young-Seek;Kim, Dong-Seog
    • Journal of Environmental Science International
    • /
    • v.18 no.1
    • /
    • pp.61-72
    • /
    • 2009
  • Fabrication and oxidants production of 3 or 4 components metal oxide electrode, which is known to be so effective to destruct non-biodegradable organics in wastewater, were studied. Five electrode materials (Ru as main component and Pt, Sn, Sb and Gd as minor components) were used for the 3 or 4 components electrode. The metal oxide electrode was prepared by coating the electrode material on the surface of the titanium mesh and then thermal oxidation at $500^{\circ}C$ for 1h. The removed RhB per 2 min and unit W of 3 components electrode was in the order: Ru:Sn:Sb=9:1:1 > Ru:Pt:Gd=5:5:1 > Ru:Sn=9:1 > Ru:Sn:Gd=9:1:1 > Ru:Sb:Gd=9:1:1. Although RhB decolorization of Ru:Sn:Sb:Gd electrode was the highest among the 4 components electrode, the RhB decolorization and oxidants formation of the Ru:Sn:Sb=9:1:1 electrode was higher than that of the 3 and 4 components electrode. Electrogenerated oxidants (free Cl and $ClO_2$) of chlorine type in 3 and 4 components electrode were higher than other oxidants such as $H_2O_2\;and\;O_3$. It was assumed that electrode with high RhB decolorization showed high oxidant generation and COD removal efficiency. OH radical which is electrogenerated by the direct electrolysis was not generated the entire 3 and 4 components electrode, therefore main mechanism of RhB degradation by metal oxide electrode based Ru was considered indirect electrolysis using electrogenerated oxidants.

A Study on the Treatment of Wastewater from Small-scale dyehouse (소규모 염색공장 폐수의 처리에 관한 연구)

  • 이준현;허항록;김광진;김민영;신재영
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.23-25
    • /
    • 2002
  • This study was conducted to understand characteristics of wastewater which is discharged from small-scale dyehouse located in Seoul downtown area and to Find the appliable treatment method on the spot. The results of this study were summarized as followings. 1. The method which is used at present is mostly flocculation by coagulant or fenton oxidation. But the treatment efficiency of them are not good. 2. The results of fenton oxidation experiment demonstrated that treatment efficiency of COD was limited, which showed the need of the additional process or the improvement of existing treatment method, while the color was reduced considerably in optimal condition. 3. The optimal condition of fenton oxidation are as followings. -Feasible pH was in the 3∼4 regardless of the kinds of iron ions, But the fluctuation of treatment efficiency with the change of pH was small - The mass ratio of H$_2$O/CODcr was used to evaluate the parameter of H$_2$O$_2$ The optimal range of this was in 0.7∼1,3 and it was observed that the ratio got higher as the quality got worse. -For iron ion, FeCl$_2$4H$_2$O turned out to be more effective for removal of color compared with was compared FeSO$_4$7H$_2$Oin. the mass ratio of Fe/H$_2$O$_2$ of 2.3∼2.8 for of FeSO$_4$7H$_2$O and 1.6∼1.8 for FeCl$_2$4H$_2$O resulted in good treatment efficiencies. 4. With adsorption process applied before fenton oxidation in order to treat the high concentration wastewater, the treatment efficiency increased by 61% in CODcr, 55% in color. and if the power activated carbon is injected in more than 2500mg/$\ell$, the wastewater can be treated within the effluent quality criteria.

  • PDF

Studies on the Wastewater of General Hospital and It에s Treatment -Effects of Disinfectants on Activated Sludge Process- (病院廢水의 特性과 處理에 關한 硏究 -消毒劑가 활성스러지법에 미치는 영향-)

  • Ra, Kyu Hwan;Ok, Chi Sang
    • Journal of Environmental Health Sciences
    • /
    • v.10 no.1
    • /
    • pp.13-20
    • /
    • 1984
  • The hospital wastewaters have to be so disposed as to prevent disease and to protect water resources from hazardous substances disinfectants, medicines, and chemicals. Polyvinylpyrrolidone-iodine complex (povidone-iodine) is widely used in the hospital as one of disinfectants. This study was carried out to manifest the effect of disinfectants in growth of activated sludge in treatment of the hospital wastewater by the activated sludge process. The results are as follow. 1. An average water quality of the hospital wastewater showed 7.2 in pH, 3.2 ppm in DO, 293.3 ppm in SS, 96.0 ppm in BOD, 151.1 ppm in COD, 0.4 ppm in povidone-iodine, 0.5 ppm in phenols, 5.4 ppm in surfactants, 1.6 ppm in o-phosphate, 4.6 ppm in $NH_3-N, 249\times 10^4$ counts/100 ml in coliform group organisms, and $1,369\times 10^2$ counts/ml in general counts of bacteria. And wastewater amounts discharged per bed was calculated 70 l/d/bed. 2. In batch culture activated sludge process, each of cresol and povidone-iodine was not effected in less than 0.1 ppm concentration, but the more concentration, the more inhibit the growth rate of activated sludge. In the mixture of two disinfectants, the growth was more inhibited the effect of single disinfectants. So that this reaction is considered as addition effect of two disinfectants. 3. The removal rates of the disinfectants-by continuous culture activated sludge process were 77.6% in 0.4 ppm povidone-iodine, and in BOD was 85.6%. 4. It is desirable that the hospital wastewater is planed in order to be discharged to two system separately, sewer from life system and wastewater from medical system. From those results, it has been concluded that the hospital wastewater has to be treated safely by the activated sludge process.

  • PDF

Effective Chemical Treatment of Biologically Treated Distillery Wastewater in Industrial Scale (생물학적으로 처리한 주정폐액의 효율적인 화학적 처리방법)

  • Nam, Ki-Du;Chung, In;Hur, Daniel;Park, Wan
    • Journal of Life Science
    • /
    • v.9 no.6
    • /
    • pp.692-697
    • /
    • 1999
  • For further removal of non-biodegradable CODs and color in biologically treated distillery waster water, we selected a chemical treatment with Fe(III) and cationic polymers and then another chemical treatment with Fenton reagent. We developed Pregenerated Bubble Flotation(PBF) to effectively remove the chemical sludge from each chemical reaction process. The flotation unit was constructed with hydraulic loading rate, 7 ㎥/$m^2$.hr. The CODMn and suspended solids (SS) in biologically treated distillery waste water were reduced by the first PBF from 310-1096 mg/L to 141-303 mg/L and from 160-990 mg/L to 48-385 mg/L, respectively. Again, after the Fenton reaction process, floated SS was skimmed off at the top of the flotation unit and the final effluent was directly discharged without any tap water dilution. The quality of final effluent can be below 40 mg/L-CODMn but IISan Distilery has been maintained effluent quality of 73 mg/L-CODMn and 10-80 mg/L-SS. The chemical cost was saved by more than 30% as compared with that of prior process.

  • PDF

Filtration Performance in MSBR (Membrane-Coupled Sequencing Batch Reactor) using a Membrane for Both Filtration and Aeration (막결합형 연속회분식 생물반응조에서 여과 및 공기공급용으로 분리막을 사용할 때 공기공급이 막여과 성능에 미치는 영향)

  • Ryu, Kwan-Young;Park, Pyung-Kyu;Lee, Chung-Hak
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.337-346
    • /
    • 2005
  • An MSBR using a membrane for not only filtration but also aeration (MA-MSBR) was designed to reduce membrane fouling and to enhance water quality, and compared with an MSBR using a membrane for only filtration (BA-MSBR). COD removal efficiency of the MA-MSBR was similar to that of the BA-MSBR, but membrane performance of the MA-MSBR was better than that of the BA-MSBR. The MA-MSBR had more small particles in mixed liquor, so the specific cake resistance of flocs in the MA-MSBR was higher than that in the BA-MSBR. However, in the aerobic reaction step of the MA-MSBR, air went through membrane pores and out of the membrane surface, so cake layers on the membrane surface and a portion of organics adsorbed on membrane pores could be removed periodically. Therefore, cake resistance, $R_c$, and fouling resistance by adsorption and blocking, $R_f$, for the MA-MSBR increased more slowly than those for the BA-MSBR. Additionally, in order to compare the energy efficiency for two MSBRs, oxygen transfer efficiency and power to supply air into the reactor by a membrane module and a bubble stone diffuser were measured using deionized water. From these measurements, the transferred oxygen amount per unit energy was calculated, resulting that of MA-MSBR was slightly higher than that of BA-MSBR.

Assessment of Seasonal Variation in Water Quality in Daedong Lake (대동호의 시기별 및 계절별 수질변화 평가)

  • Yun, Jin-Ju;Kang, Se-Won;Park, Jong-Hwan;Seo, Dong-Cheol;Kim, Hyun-Woo;Cho, Ju-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.3
    • /
    • pp.197-203
    • /
    • 2020
  • BACKGROUND: Most lakes have increased concerns about water pollution due to the inflow of non-point sources caused by human activities. Therefore, the lake water quality survey was conducted in order to propose effective plans for water quality management by analyzing the characteristics of lakes and the change of water quality. METHODS AND RESULTS: In order to investigate the physicochemical water quality in Daedong lake, water quality analysis was undertaken from July 2018 to June 2019. Water temperature was ranged from 7.8 to 34.3℃ and pH varied from 6.9 to 10.2. The concentration of Dissolved oxygen, Suspended solid, Biochemical Oxygen Demand (BOD), and Chemical Oxygen Demand (COD) were 5.6 ~ 17.2 mg/L, 2.4 ~ 35.3 mg/L, and 4.5 ~ 15.1 mg/L, and 0.9 ~ 2.8 mg/L, respectively. The Total Nitrogen (T-N) concentration ranged from 0.974 ~ 2.126 mg/L, and Total Phosphorus (T-P) concentration ranged from 0.014 ~ 0.057 mg/L. The Chlorophyll-a (Chl-a) ranged from 2.7 ~ 37.9 mg/㎥. Through Carlson TSIm assessment using T-P and Chl-a results, evaluating trophic state, Daedong lake was evaluated as mesotrophic. CONCLUSION: Water pollution management plan needs such as nutrient removal technology and nonpoint source management for prevention of eutrophication in Daedong lake.

Bio-regeneration of Ion-exchange Resin for Treating Reverse Osmosis Concentrate (RO 농축폐액의 처리를 위한 이온교환수지의 생물재생)

  • Bae, Byung-Uk;Nam, Youn-Woo
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.5
    • /
    • pp.517-523
    • /
    • 2014
  • In order to remove both nitrate and sulfate present in the concentrate of RO(reverse osmosis) process, a combined bio-regeneration and ion-exchange(IX) system was studied. For this purpose, both denitrifying bacteria(DNB) and sulfate reducing bacteria(SRB) were simultaneously cultivated in a bio-reactor under anaerobic conditions. When the IX column containing a nitrate-selective A520E resin was fully exhausted by nitrate and sulfate, the IX column was bio-regenerated by pumping the supernatant of the bio-reactor, which contains MLSS concentration of $125{\pm}25mg/L$, at the flowrate of 360 BV/hr. Even though the nitrate-selective A520E resin was used, the breakthrough curves of ionic species showed that sulfate was exhausted earlier than nitrate. The reason for this result is due to the fact that the concentration of sulfate in RO concentrate was 36 to 48 times higher than nitrate. The bio-reactor was successfully operated at a volumetric loading rate of 0.6 g $COD/l{\cdot}d$, nitrate-N loading rate of 0.13 g $NO_3{^-}-N/l{\cdot}d$, and sulfate loading rate of 0.08 g $SO_4{^{2-}}/l{\cdot}d$. The removal rate of SCOD, nitrate-N, sulfate was 90, 100, and 85%, respectively. When the virgin resin was fully exhausted and consecutively bio-regenerated for 2 days, 81% of nitrate and 93% of sulfate were reduced. When the virgin resin was repeatedly used up to 4 cycles of service and bio-regeneration, the ion-exchange capacity of bio-regenerated resin decreased to 95, 91, 88, and 81% of virgin resin.

Study on the Wastewater Treatment by Floating Aquatic Plant System Using Water Hyacinth for the Industrial Complex in Rural Area (물옥잠을 이용한 수중처리방법에 의한 농공단지 폐수처리에 관한 연구)

  • 윤춘경;김형중;류재현;여운식
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.3
    • /
    • pp.64-71
    • /
    • 1997
  • Floating aquatic plant system using water hyacinth was applied to examine feasibility as a wastewater treatment system for the industrial complex in rural area. The wastewater from the industrial complex does not likely contain toxic pollutants because the industries which generate wastewater with toxic compounds are not allowed to move in. Pilot plant was installed at Baeksuk Nongkong Danzi in Chunahn-City, Chunchungnam - Do , and field study was performed during summer and fall of 1996. Hydraulic loading rate was 0. $0.19m^3/m^2$.day. The effluent concentration of DO was higher than influent, and it implies that 0.6m depth reactor was reaerated enough to increase DO level. The influent concentration of BOD varied significantly from less than 30 to 120mg/${\ell}$ during the study period, however, effluent concentrations were generally lower than the water quality standard and removal efficiency was up to 85%. The influent concentration of COD also showed wide variation from less than 40 to 160mg/${\ell}$ and effluent concentration was higher than water quality standard when influent concentration was over l00mg/${\ell}$. The influent concentrations of T-N and T-P were lower than water quality standard and no further treatment was required, and these compounds were also removed in the system. Although some improvement and refinement are still required, overall* the floating aquatic plant system was proved to be feasible to apply to treat wastewater from industrial complex in rural area.

  • PDF

Microbial Community Analysis in the Wastewater Treatment of Hypersaline-Wastewater (고농도 염분폐수의 정화능이 우수한 기능성 미생물 커뮤니티의 군집 분석)

  • Lee, Jae-Won;Kim, Byung-Hyuk;Park, Yong-Seok;Song, Young-Chae;Koh, Sung-Cheol
    • Microbiology and Biotechnology Letters
    • /
    • v.42 no.4
    • /
    • pp.377-385
    • /
    • 2014
  • In this study, a wastewater treatment system for hypersaline wastewater utilizing the Hypersaline Wastewater Treatment Community (HWTC) has been developed. The hypersaline wastewater treatment efficiency and microbial community of the HWTC were investigated. The average removal efficiencies of chemical oxygen demand were 84% in an HRT of 2.5 days. Microbial community analysis, by denaturing gradient gel electrophoresis (DGGE) of PCR-amplified 16S rRNA gene fragments and 16S rRNA gene clone library, revealed community diversity. The 16S rRNA gene analysis of dominant microbial bacteria in 4% hypersaline wastewater confirmed the presence of Halomonas sp. and Paenibacillus sp. Phylogenetic analysis suggested that the taxonomic affiliation of the dominant species in the HWTC was ${\gamma}$-proteobacteria and firmicutes. These results indicate the possibility that an appropriate hypersaline wastewater treatment system can be designed using acclimated sludge with a halophilic community.

Organic Matter Degradation and Nitrification Characteristics in Aerobic Digestion of Sewage Sludge (슬러지 호기성 소화공정에서의 유기물 분해 및 질산화 특성)

  • Hwang, Eung-Ju
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.10
    • /
    • pp.865-872
    • /
    • 2009
  • Continuous operation of aerobic sludge digestion reactor was attempted for 279 days. Anaerobic digester sludge, the target material of the experiment, was pretreated by sodium hydroxide at $40^{\circ}C$ for 120 minutes, and the pretreated sludge was fed to 5 L CSTR (continuous stirred tank reactor). Reactor performance was affected by properties of input sludge and HRT (hydraulic retention time). 6 days of HRT showed best and stable performance, and under this condition, removal rates of $NH_3$-N, SCOD, TKN, TCOD, SS, and VSS were 97.4%, 81.7%, 68.7%, 61.4%, 50.6%, and 47.0%, respectively. 73.9% of SS in anaerobic digester sludge was reduced by pretreatment and aerobic digestion. Effluent sludge had low soluble COD of 350 mg/L. This implied the sludge was stabilized and suitable for use as liquid fertilizer. Nitrification took place when HRT was higher than 4 days. $NO_3$-N concentration was as high as 658 mg/L while $NH_3$-N was as low as 20 mg/L.