• Title/Summary/Keyword: COD

Search Result 3,273, Processing Time 0.029 seconds

The State and Sources of Contamination with BOD, COD, T-N and T-P in Stream Within Chonju City (전주시 하천의 BOD, COD,총질소, 총인에 대한 수질현황 및 오염원)

  • 오창환;이지선;김강주;황갑수
    • Economic and Environmental Geology
    • /
    • v.35 no.1
    • /
    • pp.43-54
    • /
    • 2002
  • The Chonju and Samchun streams are palling though Chonju City and several contamination sources are located along these streams. The Samchun stream joins the Chonju stream in the Gosapyeong waste disposal site and the Chonju stream finally joint to the Mankyeong River. The Chonju and Samchun streams are now contaminated with BOD, COD, T-N and T-P and the amounts of each contamination are increasing from upper stream to downstream. At the downstream the amounts of COD. T-N.T-P are several times higher than fifth grade of water quality thor lacustrine. Sewage from Chonju provides BOD, COD,T-N and T-P into the Chonju and Samchun streams and Chonju Waste Water Treatment Plant il a main source of COD, T-N and T-P contamination. Gosapyeong waste disposal site may be the source of BOD and COD contamination. T-N is higher than fifth grade of water quality for lacustrine at the upper stream indicationg that the rivers are contaminated with T-N before inflowing into Chonju by agricultural activity. The Chonju stream asffects the contamination of the Mankyeong river with BOD. COD, T-N,T-P. Other branch steams of the Mankyeong river also affects the contamination of the Mankyeong river by BOD, COD, T-N and T-P, Among the branch streams, the Ikasn stream is a main contamination source. Amounts of concentrations inflowing from the Chonju and Sanchun Streams on Aug. 1999 are calculated by using yeasured flow rate find concentrations of contaminants The result are as fikkiws; 1) the amounts of influent from the Gosan Stream are 0.49, 0.86, 1.61 and 0.01 ton/day for BOD, COD, T-N and T-P, respectively, 2) compared to the amounts of influent from the Gosan Stream, BOD, COD,T-N,T-P supplied from the Chonju river are higher by about 5, 7, 7. 36 times, respectively, and those supplied from the Iksan stream are higher by about 13, 10, 10, 147 times, respectively.

Characteristics of COD Removal in the Electrolytic Treatment of Dyeing-Wastewater (전기분해에 의한 염색폐수의 COD 제거 특성)

  • 강광남;윤용수
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.2
    • /
    • pp.139-146
    • /
    • 1998
  • The characteristics of color and COD removal for dyeing-wastewater using electrochemical reaction were investigated. >From the result, the removal efficiency of color and COD were increased with increase of temperature, decrease of electrode distance, increase of electrolyte concentration and increase of potential and these were obtained above 99%, above 75% within 30 min, individually. Cause of higher COD removal efficiency, it is more suitable that dyeing-wastewater is treated by electrolytic treatment prior to biological treatment. It is concluded that the electrolytic treatment of dyeing-wastewater can be used as the effective and economical method in practical treatment.

  • PDF

Change Pattern Analysis of the COD and Nutrient Concentration in Jumunjin Harbour, Gangneung (강릉 주문진항 COD 및 영양염류의 농도변화 양상 분석)

  • Cho Hong-Yean;Kim Chang-Il;Lee Dal-Soo;Han Dong-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.18 no.3
    • /
    • pp.211-224
    • /
    • 2006
  • It was analysed that spatial and temporal change patterns of COD, TN and TP were measured monthly from 2002 to 2005 in Jumunjin Harbour. Cenerally, concentration of upper layer higher than lower layer, concentration difference of COD, TN and TP on upper lower layer at inner zone in Jumunjin Harbour higher than sea area front of breakwater. Seasonal change width of COD concentration different, but seasonal change pattern of COD, $NH_{4}-N$ and TN clearly showed. Water quality improvement effect of seawater exchange facilities and sewage treatment plants is analysed quantitatively using averaged spatial and temporal data set. Change of COD small at 2003, concentration reduced about $34{\sim}47%$ at all zones on 2004 and 2005. TN was influenced largely effect of seawater exchange facilities. Concentration reduction at zone 1, 2, 3 estimated about $60{\sim}70%,\;40{\sim}60%,\;40%$, respectively. As a consequence, concentration reduction of COD and TN that is, effect of water quality improvement influenced seawater exchange facilities appeared not only at inner zone, also sea area front of breakwater and entrance of Jumunjin Harbour.

Modeling for Pollution Contribution Rate of Land based Load in Masan Bay (마산만 육상기인오염원의 오염기여율 모델링)

  • Jung, Woo-Sung;Hong, Sok-Jin;Lee, Won-Chan;Kim, Hyung-Chul;Kim, Jin-ho;Kim, Dong-Myung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.1
    • /
    • pp.59-66
    • /
    • 2016
  • Pollution contribution rate that is effect on water quality from land based load in Masan bay was showed quantifiably for coastal water quality management by using ecological model. It was calculated by difference of water quality concentration at each points t hat is calculated by each scenarios that are presence or absence of each sources (16 points). Results show that, rivers of Northern Masan bay contributed in Masan bay COD is 20 %, T-P is 62 % at northern part and COD is 10 %, T-P is 16 % at middle part. As a result, rivers of Northern Masan bay had effect on water quality of northern Masan bay and middle Masan bay. Also, T-P load affects water quality bigger than COD load, because T-P contribution rate bigger than COD contribution rate of northern rivers. Dukdong WTTP that is land pollution source of southern Masan bay contributed in Masan bay COD is 26 %, T-P is 11% at middle part, COD is 17 %, T-P is 7 % at middle part and COD is 10 %, T-P is 1 % at outer part. It affects water quality bigger at southern and middle of Masan bay than outer bay, because residual flow of bottom flows toward inner of Masan bay nearby Dukdong WTTP.

Improved Organic Removal Efficiency in Two-phase Anaerobic Reactor with Submerged Microfiltration System (침지형 정밀여과시스템을 결합한 이상 혐기성 시스템에 의한 유기물 제거율의 향상)

  • Jung, Jin-Young;Chung, Yun-Chul;Lee, Sang-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.629-637
    • /
    • 2000
  • A two-phase anaerobic reactor with a submerged microfiltration system was tested for its ability to produce methane energy from organic wastewater. A membrane separation system with periodic backwashing with compressed air was submerged in the acidogenic reactor. The cartridge type of microfiltration (MF) membrane with pore size of $0.5{\mu}m$ (mixed esters of cellulose) was tested. An AUBF (Anaerobic Upflow Sludge Bed Filter: 1/2 packed with plastic media) was used for the methanogenic reactor. Soluble starch was used as a substrate. The COD removal was investigated for various organic loading with synthetic wastewater of 5,000 mg starch/L. When the hydraulic retention time (HRT) of the acidogenic reactor was changed from 10 to 4.5 days, the organic loading rate (OLR) varied from 0.5 to $1.0kg\;COD/m^3-day$. When the HRT of the methanogenic reactor was changed from 2.8 to 0.5 days, the OLR varied from 0.8 to $5.8kg\;COD/m^3-day$. The acid conversion rate of the acidogenic reactor was over 80% in the 4~5 days of HRT. The overall COD removal efficiency of the methanogenic reactor showed over 95% (effluent COD was below 300 mg/L) under the highly fluctuating organic loading condition. A two-phase anaerobic reactor showed an excellent acid conversion rate from organic wastewater due to the higher biomass concentration than the conventional system. A methanogenic reactor combined with sludge bed and filter, showed an efficient COD and SS removal.

  • PDF

The prevalence, clinical and radiographic characteristics of cemento-osseous dysplasia in Korea

  • Cho, Bong-Hae;Jung, Yun-Hoa;Nah, Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.37 no.4
    • /
    • pp.185-189
    • /
    • 2007
  • Purpose: This study was intended to estimate the prevalence of cemento-osseous dysplasia (COD) in the Korean population and to assess the clinical and radiographic characteristics of this condition. Materials and Methods: Panoramic radiographs from 10,646 patients (4,982 males and 5,664 females, age range from 6 to 91 years) were reviewed for evidence of COD. Their demographics, clinical characteristics, and radiographic features were retrospectively assessed. Results: Of 10,646 panoramic radiographs, 33 radiographs (0.31 %) exhibited evidence of COD. The prevalence of COD increased to over 1 % in women over 40-years old. Of these 33 patients, 16 had florid cemento-osseous dysplasia (FCOD) and 17 had focal COD. Due to the multiplicity of FCOD, a total of 63 COD lesions were assessed. These lesions were most common in the mandibular molar area. Most of the COD lesions examined (61.9%) were less than 10 mm and the majority (82.5%) showed radiopacity. Conclusion : COD has a predilection for the mandibular molar area of middle-aged and older women.

  • PDF

Development of Continuous Real-time COD Measurement Sensor with Double Beam and Multiple Wavelength Analysis (더블 빔 구조, 다파장 분석을 적용한 연속식 실시간 COD 측정 센서 개발)

  • Lee, Joon-Seok;Shin, Daejung;Hyoung, Gi-Woo;Ryu, In-Jae
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.272-277
    • /
    • 2014
  • At present, the index of chemical oxygen demand (COD) is widely used as an indicator of organic water pollution with biochemical oxygen demand (BOD). But, traditional COD measurement method are not only with various chemical reagents exhausted, but also long time consumed, the operation procedure and the modification are much professional. This paper reported a novel COD measurement system using double-beam and multiple wavelength analysis UV-VIS spectrometries. It consists of pulsed xenon lamp, two-way optical fiber, optical switch, spectrometer and main processor. Proposed COD measurement system obtains any spectral information of water sample (KHP standard sample and two river water and wastewater) and reference sample (distilled water) in the range of 200~520 nm, corresponding to the COD concentration from 0 to 300 mg/L through calculating the UV absorbance. The system show improved precision and can work continuously fast at time interval about 25 seconds.

Study on the Optimization of Substrate and COD-reduction in the Cultivation of Yeast Candida rugosa in Sugar Beet Stillages (사탕무알콜증류폐액을 기질로 Candida rugosa 효모균체를 생산할 때 기질의 최적화와 COD감소에 대한 연구)

  • Lee, Ki-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.3
    • /
    • pp.119-125
    • /
    • 2004
  • Sugar beet stillages were used as a substrate for the production of single cell protein by a thermotolerant yeast Candida rugosa. 3 Stillage substrates were nutritionally optimized for the better production of yeast biomass and for the reduction of COD. The addition of Phosphorus(P) was required for all stillages, but Nitrogen(N) only when the residual sugar remained. The addition of P increased the biomass production to 23-61%. The addition of N increased the biomass production only a little, but when added together with P increased to 90%. The COD decreased to 26-46% when P was added, but decreased to 85% when P was added together with N.

  • PDF

Management of TOC and COD Organic Matter of Effluents in Sewage Treatment Plants (하수처리장 방류수에서 TOC와 COD 유기물관리)

  • Hwang, Seuk-Ho;Park, Je-Chul
    • Journal of Environmental Science International
    • /
    • v.27 no.4
    • /
    • pp.261-266
    • /
    • 2018
  • In this study, the organic matter of effluents from sewage treatment plants, located in the Nakdong watershed was investigated. Regression equations were computed using treated sewage data to convert the chemical oxygen demand(COD) concentrations, which are mostly available from an open database, into total organic carbon(TOC) concentrations. The average concentration of organic matter in the sewage treatment plant effluents were 2.2~16.8 mg/L for COD and 3.4~14.3 mg/L for TOC. The concentrations of COD were positively correlated with the TOC concentrations. The correlation between COD and TOC was relatively high, at 0.865(p<0.01). Based on these results, regression analysis was conducted. The regression equation for TOC was $1.651{\times}COD_{Mn}-0.084$ ($R^2=0.84$). Furthermore, organic matter-related databases for more sewage treatment plants need to be built in order to establish TOC standards and manage the water quality.

A study on the correlation between V charpy absorbed energy and critical COD value in the welded parts of high tensil strength steel under various welding methods (고장력강 용접부에 있어서 한계 COD값과 V charpy충격치와의 상관성에 관한 연구)

  • 김영식;김충해
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.57-67
    • /
    • 1988
  • Although handicapped by the inability to bridge the size gap between small laboratory sample and large engineering component, the V charpy test sample method does possess certain advantages, such as each of preparation, simplicity of test method, speed, low cost in test machinery, and low cost per test. On the other hand, the COD test method does posses advantages, which reduce the size gap between the laboratory sample and actual engineering component. Consequently, the correlation between V charpy absorbed energy and the critical COD value is required for estimating critical COD value from the simple V charpy test results. In this paper, the high tensile strength steel AH36 plate specimens having a single edge cracked notch were investigated to find out the correlation between V charpy absorbed energy and critical COD value in the welded parts under such various welding methods as shielded metal arc welding, the submerged arc welding and the electro gas welding by means of V charpy impact test and static 3-point bending test. Main results obtained are as follow ; 1. The relationships between V charpy absorbed energy Wc' and critical COD value ($\delta_c$)show; $\delta_c$=0.0065 Wc'+0.1906. 2. Ductile- brittle transition behaviours can be estimated by means of fracture appearance and general yielding behaviours. 3. The V charpy absorbed energy of SMAW is higher than that of SAW, EGW and similar relationships are obtained in the COD tests.

  • PDF