• 제목/요약/키워드: COD제거

검색결과 642건 처리시간 0.029초

화학적 응집공정에서 요인배치 중심합성설계법을 이용한 축산폐수의 COD 제거특성 평가 및 최적화 연구 (Analysis of Removal Characteristics and Optimization of Livestock Wastewater using a Factorial Design in the Coagulation Process)

  • 조일형;이내현;장순웅;안상우;윤영한;조경덕
    • 한국물환경학회지
    • /
    • 제23권1호
    • /
    • pp.111-121
    • /
    • 2007
  • The experimental design and response surface methodologies haven been applied to the investigation of the chemical coagulation of livestock wastewater. The chemical coagulation reactions were mathematically described as a function of parameters raping mixing (rpm) of chemical coagulation ($X_1$), slow mixing (rpm) of chemical coagulation ($X_2$), $FeCl_3 $ concentration (mg/L) ($X_3$) and pH ($X_4$) being modeled by use of the central composite design. Empirical models were developed to describe relationship between the experimental variables and response. Statistical analysis indicates that three factors ($X_1$: raping mixing (rpm), $X_2$: slow mixing (rpm), $X_3$: $FeCl_3 $ concentration (mg/L) on the linear term (main effect), slow mixing (rpm) (${X_2}^2$) on the non-linear term (quadratic), and two factors ($X_1-X_3$, $X_2-X_3$) on the non-linear term (cross-product) had significant effects, respectively. The estimated ridge of maximum responses and optimal conditions for CODcr using canonical analysis was 87.44% ($X_1$: 229 rpm, $X_2$: 51 rpm, $X_3$: 877 mg/L, $X_4$: 4.3). To confirm this optimum condition, three additional experiments were performed and the mean CODcr removal (%) and concentration (mg/L) with a standard deviation of $87{\pm}1.2%$ ($576{\pm}34ppm$) were obtained.

관형 알루미나 세라믹 한외여과막에 의한 고도정수처리 시스템에서 물 역세척의 영향 (Effect of Water-back-flushing in Advanced Water Treatment System by Tubular Alumina Ceramic Ultrafiltration Membrane)

  • 박진용;이송희
    • 멤브레인
    • /
    • 제19권3호
    • /
    • pp.194-202
    • /
    • 2009
  • 본 연구에서 처리수를 이용한 주기적인 역세척은 춘천시 공지천의 관형 세라믹 한외여과막에 의한 고도정수처리 시스템에서 막오염을 저감하고 투과선속을 향상시키고자 수행되었다. 일정한 역세척 시간(BT) 15초에서 여과시간 즉, 물 역세척 주기(FT) 2분이 가장 높은 무차원 투과선속(초기 투과선속에 대한 투과선속)과 가장 낮은 막오염 저항값을 보였다. 또한, FT 10분으로 고정한 BT 영향의 결과에서 BT 20초가 가장 낮은 막오염 저항과 가장 높은 무차원 투과선속을 나타내어, 가장 많은 총여과부피 107.3 L를 얻을 수 있었다. 결론적으로 공지천의 정수처리에서 FT 10분과 BT 20초가 최적조건으로 관형 알루미나 정밀여과의 선행 연구결과와 정확히 일치하였다. 한편 관형 세라믹 한외여과 시스템에 의한 오염물질 평균제거율은 탁도 97.0%, 망간법에 의한 COD 32.1%, 암모니아성 질소 28.8%, 총인 54.4%로 나타났다.

하수재이용을 위한 혐기성 유동상 생물반응기 처리수의 정삼투 여과막의 적용 (Forward Osmosis Membrane to Treat Effluent from Anaerobic Fluidized Bed Bioreactor for Wastewater Reuse Applications)

  • 권대은;김정환
    • 멤브레인
    • /
    • 제28권3호
    • /
    • pp.196-204
    • /
    • 2018
  • 하수처리 혐기성 유동상 생물반응기(Anaerobic Fluidized Bed Bioreactor : AFBR)는 높은 표면적을 갖는 입상활성탄을 유동 메디아로 적용함으로써 생물막 형성 및 유지에 유리하며 이로 인해 우수한 유기물 제거 효율을 나타내나 처리된 유출수 내의 질소와 같은 영양염류의 잔존이 여전히 문제로 남아있다. 본 연구에서는 AFBR에 의해 처리된 유출수 내의 질소 배제를 위하여 정삼투막(FO membrane)을 유도용액의 종류와 농도에 따라 적용하였다. 실험결과 유출수의 총질소 배제 효율은 FO막에 적용하는 유도용액(draw solution : DS)의 종류 및 농도에 크게 의존하였다. 유도용액 농도가 증가함에 따라 FO막의 수투과량이 증가하였으며, 1 M의 NaCl을 유도용액으로 사용한 경우 총질소 배제 효율은 55%이었으나 1 M의 glucose를 유도용액을 사용한 경우 거의 완벽한 총질소 배제 효율을 나타내었다. AFBR 유출수를 FO막으로 24시간 동안 여과를 진행하였으나 파울링에 의한 수투과량의 감소는 관찰되지 않았다.

수계 내 조류 제거를 위한 전기응집 운전 특성 평가 (Evaluation of Operation Parameters for the Removal of Algae by Electro-Coagulation)

  • 정권;김도군;김석구;김원재;고석오
    • 한국물환경학회지
    • /
    • 제31권2호
    • /
    • pp.94-102
    • /
    • 2015
  • Electro-coagulation experiments were conducted with aluminum (Al) or iron (Fe) electrode in order to determine the optimal electrode material and operation conditions for algae removal. Al electrode showed higher removal rate of algae than Fe electrode because Al flocs have positive surface charges which electrostatically attract algae species having negative surface charges. Removal rate of algae and total phosphorous (T-P) was increased as current density and electrode area increases. It was also found that initial pH with neutral range was optimum for T-P removal by electro-coagulation. Bench-scale continuous flow experiments consisted of electro-coagulation reactor, agitation tank and settling tank were conducted. In electro-coagulation reactor, a large fraction of Al flocs were distributed to scum layer, due to the gas bubbles generated by electrolysis reaction. In agitation tank, most of Al flocs were settled and the optimal mixing intensity was found to be 50 rpm to achieve good settleability. The removal rate of algae was about 90-95%. Additionally, the removal rate of the T-P and COD was observed to be $73.8{\pm}8.0%$ and $75.0{\pm}3.8%$, respectively. Meanwhile, the removal rate of total nitrogen (T-N) was relatively low at only 24%.

오염부하량 및 유하거리가 인공습지에 의한 폐수처리 효율에 미치는 영향 (Effect of Pollutant Loading and Flow Distance to Wastewater Treatment Efficiency in the Constructed Wetland System)

  • 김형중;김선주;윤춘경
    • 한국농공학회지
    • /
    • 제39권5호
    • /
    • pp.97-108
    • /
    • 1997
  • Natural wastewater treatment systems using the constructed wetland system were evaluated for the wastewater from the industrial complex in rural areas. For the treatment of wastewater from the industrial complex in rural area, a pilot plant of the constructed wetland system was installed at Baeksuk agri-industrial complex in ChunahnCity, Chunchungnam-Do. The experiment with this pilot plants was performed for 1996 and 1997. Results of the study were summarized as follows. For the BOD and COD, when the pollutant loading of them was about 1 3.8g/$m^2$. day (the concentration was l24.0mg/${\ell}$) arid 24.4g/$m^2$.day(the concentration was 220.Omg/${\ell}$), the removal rate of them was high, 90.2% and 93.4%, respectively. For the SS, the effluent concentration was consistently lower than the water quality standard even though the influent concentration varied significantly, which showed that SS was removed by the system effectively which consist of soil and plants. For the T-N and T-P, when the influent pollutant loading of them were moderately high, 2.8g/$m^2$.day to 7.4g/$m^2$. day(concentration 25.0mg/${\ell}$ to 49.7mg/${\ell}$) for T-N and 1.0g/$m^2$.day to 2.6g /$m^2$.day(concentration 8.6mg/${\ell}$ to 14.7mg/${\ell}$) for T-P, the removal rate of them were 86.5% and 94.0%, respectively. The removal rate by the flow distance increased rapidly in the first 4m from the inlet zone, and gradually there after. The width of system was 2m. Overall, the result showed that constructed wetland system is a feasible alternative for the treatment of wastewater from industrial complex in rural areas. Compared to existing systems, this system is quite competitive because it requires low capital cost, almost no energy and maintenance, and therefore, very cost effective.

  • PDF

슬러지 호기성 소화공정에서의 유기물 분해 및 질산화 특성 (Organic Matter Degradation and Nitrification Characteristics in Aerobic Digestion of Sewage Sludge)

  • 황응주
    • 대한환경공학회지
    • /
    • 제31권10호
    • /
    • pp.865-872
    • /
    • 2009
  • 슬러지의 감량과 최종처분 기술 개발을 위해 실험실 규모 호기성 소화공정을 279일간 운전하였다. 혐기성 소화 슬러지를 원료로 $40^{\circ}C$에서 120분간 알칼리 전처리하여 호기성 소화조에 유입시켰다. 유입 슬러지 성상과 HRT의 변화에 따라 소화효율의 변화가 있었으며 적정 HRT는 6일인 것으로 나타났다. 이때 $NH_3$-N, SCOD, TKN, TCOD, SS, VSS의 평균 제거율(소화조 유입 슬러지 기준)은 각각 97.4%, 81.7%, 68.7%, 61.4%, 50.6%, 47.0% 이었다. SS는 전처리와 호기성 소화를 통해 원료 슬러지(23,920 mg/L)의 73.9% 감량화가 가능하였다. 처리 슬러지는 약 350 mg/L의 SCOD를 포함하고 있어 액비로 활용하기에 무리가 없을 것으로 판단되었다. HRT를 5일 이상으로 유지할 경우 질산화 반응이 활성화되었으며 최대 658 mg/L의 유출 슬러지 질산성 질소 농도를 얻을 수 있었다. 암모니아성 질소 농도는 20 mg/L 내외로 크게 감소하였다.

초전도 자기분리에 의한 제지폐수 처리를 위한 응집반응 연구 (Study on coagulation reaction of paper wastewater for superconducting HGMS)

  • 하동우;김태형;김영훈;하태욱;오상수;송규정;하홍수;고락길;김호섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.298-298
    • /
    • 2008
  • 제지산업은 다량의 용수를 사용하면서 또한 많은 양의 폐수를 배출하고 있다. 기존의 폐수처리 공정에서는 침전처리를 위한 큰 공간과 오랜 시간이 요구되어 처리비용이 비교적 많이 드는 단점이 있다. 이러한 기존 기술의 문제점을 보완할 수 있는 새로운 고도처리가 가능한 초전도 마그네트를 이용한 자기분리 기술을 적용하고자 하였다. 자기분리의 기본 원리는 강력한 자기력에 의하여 액체에 포함된 자성입자를 분리해내는 것으로 자성입자들이 자계의 힘에 의하여 잡아당겨지고 포획될으로서 제거되는 것이다. 자기분리용 전자석으로서는 아주 이상적으로 이러한 초전도마그네트와 체(sieve) 형 자기필터를 결합시키면 아주 높은 고구배의 자장(HGMS; High Gradient Magnetic Separation)을 발생 시킬 수 있다. 초전도마그네트를 이용하면 대공간에 전력손실 없이 고자장을 발생시킬수 있기 때문에 미립자를 효과적으로 고속으로 분리하는 것이 가능해지며 또한 상자성 미세입자까지도 처리할 수 있다. 본 연구에서는 주로 유기물로 구성된 제지며|수의 부유물을 자성체와의 응집반응에 의해 플록을 형성하여 자성플록의 자기분리 효과를 연구하였다. 응집제의 종류와 응집반응 공정에 따른 자성플록의 형성 정도를 조사하였으며 자기분리 후 폐수의 탁도, COD 등의 특성을 분석하였다.

  • PDF

토양컬럼을 이용한 합성하수 중의 질소제거 (Nitrogen Removal from Synthetic Domestic Wastewater Using the Soil Column)

  • 정경훈;임병갑;최형일;박상일;문옥란
    • 한국환경과학회지
    • /
    • 제16권6호
    • /
    • pp.707-714
    • /
    • 2007
  • A laboratory experiment was performed to investigate nitrogen removal by the soil column. The addition of 20% waste oyster shell to the soil accelerated nitrification in soil column. The $NO_3^--N$ concentration in the effluent decreased with the decrease of HRT(Hydraulic Retention Time). When methanol and glucose added as carbon sources, the average removal rates of T-N(Total Nitrogen) were 82% and 77.9%, respectively. The $NO_3^--N$ removal by methanol supplementation in soil column can likely be attributed to denitrification. In continuous removal of nitrogen using the soil column, the COD(Chemical Oxygen Demand) and $NH_4^+-N$ removed simultaneously in organic matter decomposing column. The greater part of $NH_4^+-N$ was nitrified by the percolated through nitrification column, and the little $NH_4^+-N$ was found in the effluent. The T-N of 87.4% removed at HRT of 36 hrs in denitrfication column. Because of nitrified effluents from nitrification column are low in carbonaceous matter, an external source of carbon is required.

무산소조 NO3-N 농도 변화에 따른 DNPAOs에 의한 인 제거 (The Removal of the Phosphorus by DNPAOs According to the Loading of the Influent NO3-N in Anoxic Zone)

  • 김홍태;김경호
    • 한국환경과학회지
    • /
    • 제16권11호
    • /
    • pp.1271-1277
    • /
    • 2007
  • This study was conducted to investigate the ratios of phosphorus release to COD uptake, phosphorus release to nitrate removal, and phosphorus uptake to phosphorus release by DNPAOs(denitrifying phosphate accumulating organisms). In case $I{\sim}IV$, influent 1 were fed with synthetic wastewater with influent 2 $NO_3^--N$ injection to anoxic zone and the case V were fed with municipal wastewater with side stream oxic zone instead of influent 2 $NO_3^--N$ injection. As a result, the ratio of phosphorus release to carbon uptake was increased in accordance with nitrate supply. The DNPAOs simultaneously took up phosphate and removed nitrate from the anoxic reactor. In case $I{\sim}IV$, with above 20 mg/L of sufficient $NO_3^--N$ supply, phosphate was taken up excessively by the DNPAOs in anoxic condition. The large amount of both uptake and release of phosphorus occurred above 20 mg/L of nitrate supply, achieving the ratio of phosphorus uptake to phosphorus release to be 1.05. In case V, phosphate luxury uptake was not occurred in system due to 6.98 mg/L of insufficient $NO_3^--N$ supply and the ratio of phosphorus uptake to phosphorus release was 0.98. Consequently, if nitrate as the electron acceptor was sufficient in anoxic zone, the ratio was found to be high.

EM에서 SPARC 코드로 효율적인 코드 확장 (An Efficient Code Expansion from EM to SPARC Code)

  • 오세만;윤영식
    • 한국정보처리학회논문지
    • /
    • 제4권10호
    • /
    • pp.2596-2604
    • /
    • 1997
  • ACK는 가상 스택 기계에 기반을 둔 EM 중간 코드로부터 레지스터 구조에 기반을 둔 SPARC 기계에 대한 목적 코드를 생성하기 위해서는 코드 확장기(code expander)를 이용하고 있다. 따라서 EM 코드로부터 SPARC 목적 코드를 생성하기 위해 스택 지향 구조로부터 레지스터 지향 구조로 변환하여야 한다. 코드 확장기를 이용한 SPARC 코드 생성 기법은 각 EM 명령어에 대해 SPARC 코드로 확장하는 루틴들로 구성되며 코드 생성기에 비해 코드의 질을 개선하기 위해 푸쉬-팝 최적화 동작을 수행한다. 하지만 코드 확장시에 별도의 자원과 관리를 요구하는 혼합 스택(hybrid stack)을 이용하고 있으며 전단부의 정보 손실로 레지스터 윈도우를 이용한 효율적인 매개변수 전달을 고려하지 않는다. 본 논문에서는 ACK의 전체적인 구조의 변경 없이 목적 기계의 스택과 매개변수 전달을 고려하나 효율적인 SPARC 코드를 생성하기 위해 EM 트리를 이용한 SPARC 코드 확장기를 설계하고 구현하였다. 이를 위해, 순차적인 EM 코드를 입력으로 받아 스택 속성을 반영한 트리로 구성하며 혼합 스택을 제거하기 위해 지역 변수 정보를 별도로 관리하였다. EM 트리의 순회 및 확장 과정에서 목적 코드를 생성할 수 있는 루틴을 통하여 목적 코드를 출력하며 추출된 정보와 노드의 성격에 출력 시기와 목적 코드를 결정한다.

  • PDF