• Title/Summary/Keyword: COD(chemical oxygen demand)

Search Result 513, Processing Time 0.022 seconds

A Study on Water Quality Changes of Geum River Subwatersheds: In Cases of Tributary (금강수계 소유역내 수질 변화 분석 -소하천을 대상으로-)

  • Han, Ah-Won;Hong, Sun-Hwa;Hwang, Soon-Hong;Kim, Dong-Ho;Lee, Jun-Bae;Lee, Young-Joon
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.4
    • /
    • pp.328-343
    • /
    • 2012
  • BACKGROUND: For effective subwatershed management, it is very important to select the tributaries for improving water quality and understand the characteristics of tributaries. Until now, however, the case study of main streams has been managed. 17 tributaries in Geum river subwatershed were monitored to regulate the source of water contaminations and identify their current situations in this study. METHODS AND RESULTS: As pollution indicators, such as biological oxygen demand($BOD_5$), chemical oxygen demand($COD_{Mn}$), suspended solid(SS), total nitrogen (T-N), total phosphate(T-P) and total organic carbon(TOC) in Geum river were examined from January to December in 2011. The results were as follows : The annual average concentration of nutrients in Yongdam reservoir upsteam was 0.7 mg/L for BOD, 3.0 mg/L for COD, 8.4 mg/L for SS, 2.905 mg/L for T-N, 0.035 mg/L for T-P and 1.6 mg/L for TOC. Water quality of Daechung reservoir upstream was mostly similar tendency in comparison to Yongdam reservoir upstream. Among the 22 tributaries, water quality in Daechung reservoir downstream was more polluted. T-N contents were significantly high in Miho B4 located Daechung reservoir downstream(annual average concentration: 13.53 mg/L). In cases of Miho A1, A2 and C1, pollution degree was worsened during rainy season expecially. CONCLUSION(S): For improving water quality of Geum river subwatershed, the tributaries in the Mihocheon area should be preferentially considered. Mihocheon tributary is the highest in pollution site, and thus a study on long-term effects should be research.

Water Quality in Artificial Reservoirs and Its Relations to Dominant Reservoir Fishes

  • Hwang, Yoon;Han, Jeong-Ho;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.4
    • /
    • pp.441-451
    • /
    • 2009
  • The major objectives of this study were to evaluate trophic state of reservoirs using major water quality variables and its relations in terms of trophic guilds and tolerance guilds with dominant lentic fishes. For this study, we selected 6 artificial reservoirs such as Namyang Reservoir ($N_yR$), Youngsan Reservoir ($Y_sR$), Daechung Reservoir ($D_cR$), Chungju Reservoir ($Cj_R$), Chungpyung Reservoir ($C_pR$), and Paldang Reservoir ($P_dR$), and collected fish during 2000~2007 along with data analysis of water quality monitored by the ministry of environment, Korea. Biological oxygen demand (BOD) and chemical oxygen demand (COD), indicators of organic matter pollution, varied depending on types of the reservoirs and the spatial patterns in terms of trophic gradients were similar to patterns of nutrients, Secchi depth and chlorophyll-a. Analysis of trophic state index (TSI) showed that reservoirs of $D_cR$ and $C_jR$ were mesotrophy and other 4 reservoirs were eutrophic state. The relations of trophic relations showedthat TSI (Chl-a) had a positive linear function [TSI (CHL)=0.407 TSI (TP)+28.2, n=138, p<0.05] with TSI (TP) but had a weak relation with TSI (TN). Also, TSI (TP) were negatively correlated ($R^2=0.703$, p<0.05) with TSI (SD), whereas TSI (TN) was not significant (p>0.05) relations with TSI (SD). Tolerance guilds of lentic fishes, based on three types of the reservoirs, reflected the exactly water quality in the TN, TP, BOD, and COD, and similar trends were shown in the fish feeding/trophic guilds.

The method for total organic carbon analysis employing TiO2 photocatalyst (이산화티타늄 광촉매를 이용한 총유기탄소 분석방법)

  • Park, Buem Keun;Kim, Sung Mi;Lee, Young-Jin;Paik, Jong-Hoo;Shin, Jeong Hee
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.320-325
    • /
    • 2021
  • Biochemical oxygen demand (BOD) and chemical oxygen demand (COD) methods are conventional analytical methods to analyze water quality. Both of these methods are technically indirect measurement methods, require complicated preconditions, and are time-consuming. On the other hand, the total organic carbon (TOC) method is a direct and fast measurement method which is more intuitive and accurate than the BOD and COD methods. However, general TOC analysis methods involve complicated processes and high power consumption owing to the process of phase transition from liquid to gas by a high-temperature heater. Furthermore, periodic consumables are also required for the removal of inorganic carbon (IC). Titanium dioxide (TiO2) is one of the most suitable photocatalysts for simple processes. Its usage involves low power consumption because it only reacts with the organic carbon (OC) without the requirement of any other reagents and extra processes. We investigated a TiO2 photocatalyst-based TOC analysis for simple and affordable products. TiO2-coated fiber substrate maintained under carbon included water was exposed to ultraviolet (UV) radiation of wavelength 365 nm. This method is suitable for the real-time monitoring of water pollution because of its fast reaction time. Its linear property is also sufficient to match the real value.

Performance analysis for reduction facility of nonpoint source pollutant (비점오염원 저감장치의 성능분석)

  • Lee, Jong-Seok;Kim, Chi-Gon
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.3
    • /
    • pp.207-217
    • /
    • 2019
  • This study aims at development and application of a facility that is capable of reducing pollution in water quality by reducing nonpoint source pollutants (NPSP). NPSP originated from the initial rainfall caused not only large catchment of urban area pass a river but also small watershed pass a stream. For this purpose, the performance tests carried out with the field models from the facility based on the preceding study. And the tests induced reduction efficiency of biochemical oxygen demand (BOD), chemical oxygen demand (COD), total nitrogen (T-N) and suspended solid (SS), respectively. The average reduction efficiency obtained by time interval, and the result showed an excellent reduction performance. As a result, the facility satisfied reduction efficiency of NPSP of the proposed standard by the National Institute of Environmental Research, and thus it can be used in practical applications.

Stage by stage design for primary, conventional activated sludge, SBR and MBBR units for residential wastewater treatment and reusing

  • Aziz, Shuokr Qarani;Omar, Imad Ali;Bashir, Mohammed J.K.;Mojiri, Amin
    • Advances in environmental research
    • /
    • v.9 no.4
    • /
    • pp.233-249
    • /
    • 2020
  • To date, there is no central wastewater (WW) treatment plant in Erbil city, Kurdistan region, Iraq. Therefore, raw WW disposes to the environment and sometimes it used directly for irrigation in some areas of Erbil city. Disposal of the untreated WW to the natural environment and using for irrigation it causes problems for the people and the environment. The aims of the current work were to study the characteristics, design of primary and different secondary treatment units and reusing of produced WW. Raw WW samples from Ashty city-Erbil city were collected and analyzed for twenty three quality parameters such as Total Suspended Solids (TSS), total dissolved solids, total volatile and non-volatile solids, total acidity, total alkalinity, total hardness, five-day Biochemical Oxygen Demand (BOD5), Chemical Oxygen Demand (COD), biodegradability ratio (BOD5/COD), turbidity, etc. Results revealed that some parameters such as BOD5 and TSS were exceeded the standards for disposal of WW. Design and calculations for primary and secondary treatment (biological treatment) processes were presented. Primary treatment units such as screening, grit chamber, and flow equalization tank were designed and detailed calculation were illustrated. While, Conventional Activated Sludge (CAS), Sequencing Batch Reactor (SBR) and Moving Bed Biofilm Reactors (MBBR) were applied for the biological treatment of WW. Results revealed that MBBR was the best and economic technique for the biological treatment of WW. Treated WW is suitable for reusing and there is no restriction on use for irrigation of green areas inside Ashty city campus.

Changes in temporal and spatial stream water concentrations and analysis on nonpoint source runoff in forested watersheds on non rainfall days (산림소유역 유출수의 비강우일 비점오염물질 농도 변화 및 유출 특성 분석)

  • Yoo, Hyeon-Ju;Choi, Hyung-Tae;Kim, Jae-Hoon;Lim, Hong-Geun;Yang, Hyun-Je
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.23 no.6
    • /
    • pp.137-149
    • /
    • 2020
  • This study was carried out to analyze the monthly runoff concentration on non rainfall days in order to prepare basic data to compare the runoff concentration on rainfall days in 7 forest watersheds in the Republic of Korea. Forest stream water has been collected through 15 times of sampling in each watershed and analyzed based on the changes in concentration of Biochemical Oxygen Demand(BOD), Chemical Oxygen Demand(COD), Total Organic Carbon(TOC), Total Nitrogen(TN), and Total Phosphorus(TP). The average concentration was 0.8 mg/L for BOD, 1.4 mg/L for COD, 0.8 mg/L for TOC, 1.85 mg/L for TN and 0.002 mg/L for TP during non rainfall days. Coniferous forested watersheds showed higher value of TN and TP concentration. Concentrations of BOD and TP in early March (p<0.01) were affected by melt water flow input in spring season. Significant differences (p<0.01) in concentrations were observed in BOD and TOC, indicating seasonal rainfall and vegetation growth impacts on forest stream quality. Concentration of TN and TP showed significant positive correlation, and weak negative correlation was found in the concentration of BOD and TOC. It is expected that result of forest stream water on non rainfall days could be basic information in managing non-point source from forest watersheds.

Fabrication and Evaluation of a Total Organic Carbon Analyzer Using Photocatalysis

  • Do Yeon Lee;Jeong Hee Shin;Jong-Hoo Paik
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.140-146
    • /
    • 2023
  • Water quality is crucial for human health and the environment. Accurate measurement of the quantity of organic carbon in water is essential for water quality evaluation, identification of water pollution sources, and appropriate implementation of water treatment measures. Total organic carbon (TOC) analysis is an important tool for this purpose. Although other methods, such as chemical oxygen demand (COD) and biochemical oxygen demand (BOD) are also used to measure organic carbon in water, they have limitations that make TOC analysis a more favorable option in certain situations. For example, COD requires the use of toxic chemicals, and BOD is time-consuming and can produce inconsistent and unreliable results. In contrast, TOC analysis is rapid and reliable, providing accurate measurements of organic carbon content in water. However, common methods for TOC analysis can be complex and energy-intensive because of the use of high-temperature heaters for liquid-to-gas phase transitions and the use of acid, which present safety risks. This study focuses on a TOC analysis method using TiO2 photocatalysis, which has several advantages over conventional TOC analysis methods, including its low cost and easy maintenance. For TiO2, rutile and anatase powders are mixed with an inorganic binder and spray-coated onto a glass fiber substrate. The TiO2 powder and inorganic binder solutions are adjusted to optimize the photocatalytic reaction performance. The TiO2 photocatalysis method is a simple and low-power approach to TOC analysis, making it a promising alternative to commonly used TOC analysis methods. This study aims to contribute to the development of more efficient and cost-effective approaches for water quality analysis and management by exploring the effectiveness and reliability of the developed equipment.

Ship Sewage Treatment Using Fixed Media Method (고정식 메디아법을 이용한 선박의 오폐수 처리)

  • Han, Sang-Hwa;Lee, Dea-Ho;Nyung, Bu-Nyung;Bae, Sang-Bum;Yoon, Jong-Mun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.2
    • /
    • pp.99-104
    • /
    • 2010
  • The purpose of this study is to develop Sewage Treatment Plant that treat sewage which occurred in ship using fixed media method and to consider applicable to the Pilot Scale device of the STP regulations in MLTM(Ministry of Land, Transport and Maritime Affairs) and MEPC(Marine Environment Protection Committee). In test results, pH geometric mean was 7.68, $BOD_5$(Biochemical Oxygen Demand) geometric mean was 7.28 mg/l, $COD_{cr}$(Chemical Oxygen Demand) geometric mean was 48.39 mg/l, TSS(Total Suspended Solid) geometric mean was 18.00/l, Residual chlorine geometric mean was 0.19 mg/l, and E. coli geometric mean was 1CFU/100 ml. In addition, about 97.4% of $BOD_5$ was reduced, the $COD_{cr}$ reduction averaged 96.4%and the TSS reduction averaged 97.6%. STP have been determined by the MLTM and MEPC regulation of the marine pollution prevention equipment for performance testing product.

Decolorization of Dyeing Wastewater with Use of Chitosan Materials

  • Xin, Chen;Sun, Hui-Li;Pan, Jia-Hui
    • Ocean Science Journal
    • /
    • v.41 no.4
    • /
    • pp.221-226
    • /
    • 2006
  • More attention has been paid to the research on decolorization of dyeing wastewater nowadays. In this study, an investigation into the decolorization of dyeing wastewater was conducted using a combination of coagulant, carboxymethyl chitosan (NOCC) and coagulant aid, polyscrylamide (PAM). The factors influencing the decolorization efficiency, such as pH value, coagulant and the dosages of coagulant, were discussed. The results showed that using PAM as coagulant aid could reach a high decolorization efficiency compared with using NOCC alone. The optimal conditions were pH 2.3, 480 mg/L for NOCC, and 4-8 mg/L for PAM. Under the optimum conditions, the rate of decolorization could achieve 99%, and the removal of chemical oxygen demand (COD) could achieve 90%. In addition, the membrane processes with chitosan/rare-earth-metals could enhance the decolorization rate of Direct Black FF to 94.7%, and Indanthren Red F3B to 98.2%, respectively.

High-rate Anaerobic Treatment of Landfill Leachate (매립지 침출수 처리의 고율 혐기성 처리)

  • Lee, Chae-Young;Shin, Hang-Sik
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.15 no.2
    • /
    • pp.136-146
    • /
    • 2007
  • Landfill leachate was successfully treated in upflow anaerobic sludge blanket (UASB) reactors regardless of the addition of granular sludge. Initial operating period was significantly reduced by the addition of granular sludge. At hydraulic retention time (HRT) of one day, chemical oxygen demand (COD) removal rates in Control and Granule reactor were maintained over 90%, respectively with organic loading rate (OLR) of $4-8kgCOD/m^3.d$. During the experiment, the inorganic precipitates were accumulated in and around the sludge, and in the wall of the reactors were formed in both reactors regardless of addition of granular sludge. Specific methanogenic activity (SMA) increased as adaptation of microorganism to the substrate and OLR were increased. The maximum SMA value of the sludge for Granule reactor was about $0.57gCOD/g{\cdot}VSS{\cdot}.d$. The SMA value was not decreased because of excessive inorganic accumulation, however, it was needed to have pre-treatment process of influent to remove the inorganic metals.

  • PDF