Warm Start Up Time Reduction Through the Increase of Boiler Water Circulating Pump Inlet Water Temperature Rate of the Thermal Power Plant (관수온도 상승률 증가에 의한 발전용 보일러의 온간기동시간 단축에 관한 연구)

  • Kang, Hee-Seong;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.10 no.1
    • /
    • pp.47-53
    • /
    • 2014
  • The national capacity of electricity of Korea was 81,737 MW and the peak demand was renewed by the record of 71,230 MW in 2012 which has been increasing since the first lighting ceremony had taken place in the Royal Palace(Kyung-Bok Goong) in 1887. Aa the counteract on the rapid increasing of the demand, Korean government is constructing and operating the high capacity nuclear and thermal power plants, however, the operating reserve on weekdays is small while those of weekends are more than 40% of capacity, so they are providing the pumped-storage power plants with the surplus electricity during weekends and operating the power plants which cost higher production price and located in the capital area with WSS (Weekly Start and Stop) mode including the Seoul Thermal Power Plant. Since the Seoul Thermal Power Plant is spending huge amount of expenses for more than 30 times of the WSS annually due to the high production cost even though it is in Seoul, the core of the demand, I chose the power plant unit #5 which was on the grid in 1969 for the case to confirm reducing 23% of the warm start-up time by applying the "Start-up time management program", and that reducing 35% of the water temperature increasing time by accelerate the increasing rate of the inlet temperature of the water circulating pump.

  • PDF

The Effects of Thermal Degradation and Creep Damage on the Microstructure and Composition of the Carbides in the CrMo Steels for Power Plant (발전 설비용 CrMo강의 탄화물 구조와 조성 변화에 미치는 열화 및 크리프 손상의 영향)

  • Ju, Yeon-Jun;Hong, Gyeong-Tae;Lee, Hyeon-Ung;Sin, Dong-Hyeok;Kim, Je-Won
    • Korean Journal of Materials Research
    • /
    • v.9 no.10
    • /
    • pp.1018-1024
    • /
    • 1999
  • The effects of operating temperature and stress on degradation of components in high temperature steam generator were investigated. Several 2.25CrlMo tubes which had operated over 20 years and an unused 9CrlMoVNb tube were tested. For the former samples, the amount of $\textrm{M}_{6}\textrm{C}$ carbide and its size are increased with the aging or operating time. The precipitation behavior of carbides ($\textrm{M}_{2}\textrm{O}$, $\textrm{M}_{6}\textrm{C}$) is changed with the operating temperature of the tubes. However, unused 9CrlMoVNb samples show a different carbide precipitation process due to high chromium, vanadium, and niobium contents. The amount of Cr-rich $\textrm{M}_{23}\textrm{C}_{6}$ carbide is significantly increased with aging time, but that of $\textrm{M}_{6}\textrm{C}$ type carbide is rarely changed with aging time at elevated temperatures.

  • PDF

Hospital oral and maxillofacial nursing care in Jeju province (제주 지역 병원의 구강 악안면 간호 실태)

  • Kim, Sung-Joon;Kim, Se-Il;Song, Hyo-Jeong;Kahm, Se-Hoon;Lee, Byoung-Jin
    • The Journal of the Korean dental association
    • /
    • v.53 no.1
    • /
    • pp.36-46
    • /
    • 2015
  • Objectives: The objective of this work was to investigate the hospital nursing care of oral and maxillofacial health in jeju province. Methods: 438 Registered nurses(RN) who were working at each of secondary hospitals in Jeju province had responded to the questionnaire. The data were analyzed via frequency analyses and one-way ANOVA to assess the state of RN on hospital nursing care of oral and maxillofacial health. Results: The class of education on density in formal density that marked '0 hour' and '1-3 hours' were 73.5% and 19.9%, respectively. The class of refresher training on density that marked '0 hours' and '1-3 hours' were 92.9% and 6.6%, aggregately 99.5%. The nursing education on appearance after tumor of maxillofacial area that marked 'formal education' and 'none' were 45.2% and 52.1%, respectively. The score of question 'function, effect and side effect of hexamedin gaggle' was $2.68{\pm}0.95$ by Likert 5-point scale. Likewise, the scores were $2.82{\pm}0.88$ on question 'management of removal denture', $2.83{\pm}0.95$ on question 'preventive dental treatment before anticancer therapy', $2.88{\pm}0.86$ on question 'function of saliva', $2.96{\pm}0.99$ on question 'oral management of tube feeding patient', $3.13{\pm}1.00$ on question 'bacterial endocarditis from oral microflora', $3.36{\pm}0.89$ on question 'dysphagia' and $3.62{\pm}1.03$ on question 'aspiration pneumonia'. RN replied that 'lack of knowledge' and 'delay of cooperation' formed 53.7% and 33.3% respectively, on question 'problem in dental consultation other diseased patient'. Conclusions: From this study, it is necessary for RN and student of nursing science to be educated on the oral and maxillofacial nursing. Authors suggest further co-study and nation-wide research.

A pattern of cell death induced by 40 kHz ultrasound in yeast cell model (40 kHz 초음파에 의해 유도된 효모세포 모델에서 세포사멸 패턴)

  • Kim, Ji Wook;Kong, Hee Jeong;Kim, Young H.;Kang, Kwang Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.3
    • /
    • pp.172-178
    • /
    • 2017
  • Ultrasound has been widely used for biological and medical applications including induction of cell death, but a precise mechanism of induced cell death by ultrasound is controversial. In this study, an irradiation system with 40 kHz ultrasound was developed for a suitable cell death test of a representative unicellular organism, yeast, and used to study the biological effect of ultrasound on inducing cell death. Potassium Iodide (KI) dosimetry was used to devise an optimal system that successfully delivers 40 kHz ultrasound and produces reactive oxygen species in a 1.5 ml Eppendorf tube. Cell death was observed in an ultrasound transmission time-dependent fashion in this system. Thermal effect during irradiation was not observable in ultrasound induced cell death. Co-treatment of 40 kHz ultrasound and hydrogen peroxide showed a synergistic effect in inducing cell death. This finding suggests that 40 kHz ultrasound is related to reactive oxygen species formation. However, NAC (N-acetyl-L-cysteine) oxygen scavenger slightly inhibited the cell death by 40 kHz ultrasound. It was also found that 40 kHz ultrasound induced cell death was slightly inhibited by inhibitors of necrosis or apoptosis (glycyrrhizin or zVAD-fmk). This study suggests that cell death induced by 40 kHz ultrasound may not be exclusively related to reactive oxygen species formation and thermal effects in irradiated yeast cells.

Comparison of Phytoncide (monoterpene) Concentration by Type of Recreational Forest (산림휴양지 유형에 따른 피톤치드(모노테르펜) 농도 비교)

  • Lee, Yong-Ki;Woo, Jung-Sik;Choi, Si-Rim;Shin, Eun-Sang
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.4
    • /
    • pp.241-248
    • /
    • 2015
  • Objectives: This study was conducted to provide scientific and effective information on phytoncides, which are associated with forest healing, and to activate recreational forests. Methods: The target sites were natural recreation forests, a forest park and an arboretum, and the control sites were three urban parks. The samples were collected at a volume of 6.0 L and a flow rate of 0.1 L/min for one hour using a low volume pump and the solid adsorbent sampling method. The phytoncide compounds adsorbed in the Tenax TA tube were analyzed by a automatic heat desorption unit and GC-MS. Results: By type of recreational forest, the annual concentrations of phytoncide (monoterpene) for the forest park showed the highest concentration with $1.450{\mu}g/m^3$, while those for the arboretum showed the lowest concentration at $0.892{\mu}g/m^3$, and thus the concentration of the forest park was approximately 1.6 times higher than the arboretum. The season showing the highest concentration of phytoncides was summer (June) and the forest park was the highest among the recreational forests. The concentrations of major components for phytoncide showed in descending order: ${\alpha}-pinene$, ${\beta}-pinene$, camphene, 3-carene and limonene. The seasonal concentration of ${\alpha}-pinene$, camphene and ${\beta}-pinene$ by type of recreational forest increased in April, which is characterized by low temperature and humidity, and the seasonal concentration of camphene decreased with higher humidity. The meteorological factors which had the high correlation with the concentration of total terpene were temperature and humidity. $CO_2$ and $O_2$ showed an inverse correlation. Conclusion: The major components of phytoncide were ${\alpha}-pinene$, ${\beta}-pinene$, camphene, 3-carene and limonene in descending order of concentration. Further and systematic study on the chemical nature of individual phytoncides, and on the effect of phytoncides on humans needs to be performed.

Fabrication of the photon scanning tunneling microscope with constant intensity mode (일정광량 방식의 광자주사현미경 제작)

  • Kim, Ji-Taek;Choi, Wan-Hae;Jo, Jae-Heung;Chang, Soo;Kim, Dal-Hyun;Koo, Ja-Yong;Chung, Seung-Tae
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.3
    • /
    • pp.195-200
    • /
    • 1999
  • We made sharp optical fiber tips with less than 100 nm diameter by using the heating and pulling method with a good repetition and fabricated the photon scanning tunneling microscope (PSTM) using constant intensity mode. The 3-dimensional PZT (Piezoelctric transducer) scanner made of a long PZT tube is consisted of three divided parts, that is, a pair of $\pm$ x and a pair of $\pm$y scanning parts and a z scanning part for the fine approach and scanning. The scanning dimension is 1.43 $\mu\textrm{m}$$\times$1.76 $\mu\textrm{m}$. The height of a optical tip to maintain a constant height within $1/{\lambda}_0$ (${\lambda}_0$ is the incident wavelength) from surface of a specimen to a optical tip is controlled automatically by using the electric feedback circuit. The 3-dimensional shape of standing evanescent waves generated on the surface of a dove prism was measured successfully by using the constant intensity mode PSTM.

  • PDF

A Study on the Image Quality of Mammography and the Average Glandular Dose (맘모그래피의 화질과 평균유선조직선량에 관한 검토)

  • Lee, In-Ja;Kim, Hak-Sung;Kim, Sung-Soo;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.25 no.2
    • /
    • pp.47-55
    • /
    • 2002
  • We came to the following conclusion as the results of experiment on the image quality of mammography and the average glandular dose using 4 apparatuses at 3 hospitals in Seoul. 1. Whereas the measurement of half value layer showed no differences among the apparatuses, the measurement by an attenuation curve method showed some differences by 5.9%. There were 9.1% differences in the measurement by aluminum conversion method. 2. The basic density of an automatic exposure control unit must be D = 1.40, but there was no automatic exposure unit adjusted precisely at any hospitals. The unit at the B hospital exceeded the allowable limit by ${\pm}0.15$. 3. In the photographing using an automatic exposure control unit and the management of an automatic film processor using a sensitometer, most automatic film processors were well kept. But in some cases the mean value of a fluctuation coefficient exceeded the allowable limit. There is a need for more cautious management. 4. The image quality of breast phantom photography was affected by the screen/film system among the hospitals. 5. The average glandular dose at a breast of 4.2 cm thickness depended on the tube voltage, In the case of Mo/Mo, it was measured $0.26{\sim}1.39\;mGy$ less than ACR standard 3.0 mGy.

  • PDF

A Phantom Study for the Optimal Low-dose Protocol in Chest Computed Tomography Examination (흉부 전산화단층촬영검사를 위한 최적의 저선량 프로토콜에 관한 팬텀연구)

  • Kim, Young-Keun;Yang, Sook;Wang, Tae-uk;Kim, Eun-Hye
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.101-107
    • /
    • 2021
  • The purpose of this study was to evaluate optimal CT scan parameters to minimize patient dose to the irradiation and maintain satisfactory image quality in low-dose chest computed tomography (CT) scans. In a chest anthropomorphic phantom, chest CT scans were performed at different kVp and mA within reference of 3.4mGy in volume CT Dose Index (CTDIvol). The following quantitative parameters had been statistically evaluated: image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM). Nine radiographers conducted the blind test to select the optimal kVp-mA combination. Results indicated that the kVp-mA combination of 80kVp-90mA, 100kVp-50mA, 120kVp-30mA and 140kVp-30mA were obtained high SNR and CNR. The 120kVp-30mA combination offered good compromise in the FOM, which showed the quality and dose performance. In the blind test, an image of 80kVp-90mA obtained a high score with 4.7 points, and 120kVp-10mA or 140kVp-10mA with a low tube current were observed severe noise and poor image quality, thus resulting in decreased diagnostic accuracy. On the other hand, in the combination of high kVp and high mA(140kVp-90mA), the image quality was improved, but the radiation dose was also increased. the FOM value of 140kVp-90mA was lower than 120kVp-30mA. The application of appropriate scan parameters in low-dose chest CT scans produced satisfactory results in dose and image quality for the accuracy of the clinical diagnosis.

Numerical Study of the Heat Removal Performance for a Passive Containment Cooling System using MARS-KS with a New Empirical Correlation of Steam Condensation (새로운 응축열전달계수 상관식이 적용된 MARS-KS를 활용한 원자로건물 피동냉각계통 열제거 성능의 수치적 연구)

  • Jang, Yeong-Jun;Lee, Yeon-Gun;Kim, Sin;Lim, Sang-Gyu
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.27-35
    • /
    • 2018
  • The passive containment cooling system (PCCS) has been designed to remove the released decay heat during the accident by means of the condensation heat transfer phenomenon to guarantee the safety of the nuclear power plant. The heat removal performance of the PCCS is mainly governed by the condensation heat transfer of the steam-air mixture. In this study, the heat removal performance of the PCCS was evaluated by using the MARS-KS code with a new empirical correlation for steam condensation in the presence of a noncondensable gas. A new empirical correlation implemented into the MARS-KS code was developed as a function of parameters that affect the condensation heat transfer coefficient, such as the pressure, the wall subcooling, the noncondensable gas mass fraction and the aspect ratio of the condenser tube. The empirical correlation was applied to the MARS-KS code to replace the default Colburn-Hougen model. The various thermal-hydraulic parameters during the operation of the PCCS follonwing a large-break loss-of-coolant-accident were analyzed. The transient pressure behavior inside the containment from the MARS-KS with the empirical correlation was compared with calculated with the Colburn-Hougen model.

Effect of Imipramine on the Contractility of Single Cells Isolated from Canine Detrusor (Imipramine이 배뇨근 세포의 수축성에 미치는 직접작용)

  • Huh, Chan-Wook;Lee, Kwang-Youn;Kim, Won-Joon
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.2
    • /
    • pp.293-302
    • /
    • 1994
  • The objective of this study was to establish a good methodology to isolate single smooth muscle cells that are alive and respond properly to pharmacological agents. Canine urinary bladders were employed as the source of single cells, and acetylcholine, atropine and imipramine were used as indicators of pharmacological responsiveness. Imipramine, an antidepressant drug exhibited the anticholinergic and calcium antagonizing properties on rat detrusor muscle. To establish a control value for a further experiment to elucidate the mechanism of action of imipramine on detrusor muscle, we measured the concentration-response of single cells to acetylcholine in the presesnce of imipramine by length of the cells and compared the result with the response in the presence of atropine. Tiny chops of smooth muscle taken from anesthetized canine urinary bladder were incubated in collagenase solution at $36^{\circ}C$ for 17-20 minutes. The collagenase solution included collagenase 1.2 mg/ml, soybean tryspin inhibitor 0.08 mg/ml, bovine serum albumin 2% in 10 ml Krebs-Henseleit buffer solution aerated with a consistent breeze of 95/5% $O_2/CO_2$, to maintain the pH at 7.4. After washing with plain K-H solution on 450 mesh, cells were dissociated from the digested tissue for 12-15 minutes. Cell suspension was transfered in 5 ml test tubes and acetylcholine was added for the final concentration to be $10^{-14}M{\sim}10^{-9}M$. To find the optimal time to fix the cells to determine the contractile responses, 1% acrolein was added 5, 10, 20, 30, 60 and 120 seconds after the administration of ACh. The length of cells fixed by acrolein were measured by microscaler via CCTV camera on phaes-contrast microscope. The average length of 50 cells from a slide glass was taken as the value of a sample at the very concentration point. Single cells were isolated from canine detrusor. The length of untreated cells varied from 82 ${\mu}m$ to 94 ${\mu}m$. The maximal response to actylcholine $10^{-9}M$ was accomplished within 5 seconds of exposure, and the shortening was $19{\pm}3$%. Atropine reduced the contraction of the cells concentration-dependently. Imipramine which exerts a cholinergic blocking action on some smooth muscles also reduced the contraction concentration-dependently and by a similar pattern as atropine. These findings document that imipramine may exerts a cholinergic blocking activity in the single smooth muscle cells isolated from canine urinary bladder.

  • PDF