• Title/Summary/Keyword: CO tube

Search Result 809, Processing Time 0.026 seconds

Thermophysical Properties of CO2 and CO2-Hydrate Mixture and In-Tube Heat Transfer Characteristics (CO2-Hydrate와 CO2 가스 혼합물의 전달물성과 관내측 열전달계수 및 압력강하 예측)

  • Yun, Rin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.5
    • /
    • pp.233-239
    • /
    • 2013
  • The Thermophysical properties of thermal conductivity, viscosity, and heat capacity for $CO_2$ slurry ($CO_2$ gas and $CO_2$-hydrate mixture) having a high gas phase volume fraction were predicted using the conventional mixture models and the TRAPP model under hydrate formation conditions. Based on the calculated thermophysical properties, the heat transfer coefficient and pressure drop of the $CO_2$ slurry in the tube were predicted. The thermal conductivity of $CO_2$ slurry ranged from 0.02 to 0.2 W/m-K, and the mixture viscosity was larger than that of pure $CO_2$ by 1.9~2.7 times. The heat capacity of $CO_2$ slurry ranged from 63 to 68% of that for pure $CO_2$. The predicted heat transfer coefficient of $CO_2$ slurry was 6 times higher than that of pure $CO_2$. In the separate model, the estimated pressure drop increased with an increase of $CO_2$-hydrate mole fraction, and was 60% of that of pure $CO_2$.

A Study on the Condensation Performance for the Horizontal Heat Transfer Tubes with Various Fin Attached (형상이 다른 수평 원형 전열관의 응축 성능에 관한 연구)

  • Han, Kyu-Il;Park, Jong-Un
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.4 no.1
    • /
    • pp.47-61
    • /
    • 1992
  • An experimental study was carried out to investigate the condensation performance for the horizontal cylindrical heat transfer tube with various fin attached using R-11 vapor. The heat transfer tube used in this study was supplied by SUNG HYUNG METAL CO., LTD. Four different types of heat transfer tubes (plain tube, SH-CYR tube, thermocor tube and thermoexcel tube) were used. Each tube was surrounded by circular acrylate tube, and R-11 gas heated by boiler flows into the acrylate tube. Cooling water counter-flows in heat transfer tubes. Heat transfer coefficient of the plain tube from measured data was compared with those of three other tubes. The results are summarized as follows: 1. As the cooling water temperature decreased, the liquid film of R-11 turned to droplet drop on the top surface of the horizontal tube. 2. Heat transfer coefficient calculated theoretically was higher than that obtained from the experimental data. 3. As far as the condensation concerns the thermocor tube is the highest, the SH-CYR tube is the second, and the thermoexcel tube is the third excluding the plain tube.

  • PDF

The Performance Comparison of $CO_2$ Gascooler and Evaporator with Heat Exchanger Type (열교환기 형태에 따른 이산화탄소용 가스쿨러와 증발기의 성능비교)

  • Bae, Kyung-Jin;Cho, Hong-Hyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.2
    • /
    • pp.15-22
    • /
    • 2010
  • The natural refrigerants have used into HVAC equipments because the CFCs and HFCs have some environmental problems like high ODP and GWP. The carbon dioxide has small effect on the environmental problem but also good thermodynamics properties. In this study, the simulation study on the performance and characteristics of a $CO_2$ gascooler and evaporator using a fin-tube and microchannel heat exchanger has been conducted. Besides, the comparison of performance with operating condition was carried out in order to apply to the $CO_2$ heat pump system. As a result, the front sizes of a gascooler and evaporator using a microchannel were decreased by 63% and 58%, respectively, compared to those using a fin-tube. The performance of the fin-tube gascooler and evaporator were more responsive to the variation of operating conditions compared to that of microchannel. The pressure drop of a fin-tube heat exchanger was higher than that of a microchannel one.

A Study on the Standard for Installation of Carbon Monoxide Detector in a Building (건축물내 일산화탄소 경보기 설치기준에 관한 연구)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.4
    • /
    • pp.1-7
    • /
    • 2008
  • In the last five years, 36 people died and 79 were wounded because of carbon monoxide poisoning accident. A CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread mechanism of CO gas released from leakage hole of exhaust tube was analyzed by concentration measuring test. A CO gas leaked form exhaust tube in a building was the highest concentrated near the ceiling. CO alarm sets installation test confirmed that the alarm sets near the ceiling operated first, and the bottom and middle sets operated after $30{\sim}40$ minutes. Through these experiments, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

Effect of the lubrication oil on heat transfer and pressure drop characteristics of supercritical carbon dioxide in a microfin tube (마이크로핀관내 냉동기유가 초임계 이산화탄소의 열전달과 압력강하에 미치는 영향)

  • Ku, Hak-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1440-1446
    • /
    • 2012
  • This paper presents an experimental study of heat transfer and pressure drop characteristics of supercritical carbon dioxide with PAG inside a horizontal microfin tube. Heat transfer coefficient and pressure drop gradients were measured at 10 MPa in pressure and 520 kg/$m^2s$ in mass flux with variation of PAG mass concentration from 0.06% to 2.26%. The tendencies of both heat transfer and frictional pressure drop characteristics show the same as those of pure $CO_2$ up to 0.3% in PAG mass concentration. In case of 2.26% in PAG mass concentration, measured heat transfer coefficients showed 50% lower than those of pure $CO_2$ near the pseudocritical temperature and measured frictional pressure drop gradients show 1.6 times higher in comparison with those of pure $CO_2$ at $60^{\circ}C$ in $CO_2$ bulk temperature.

A Theoretical Study for the Design of a New Ballistic Range

  • Rajesh G.;Lee J.M.;Back S.C.;Kim Heuy-Dong
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.7
    • /
    • pp.1019-1029
    • /
    • 2006
  • The ballistic range has long been employed in a variety of engineering fields such as high-velocity impact engineering, projectile aerodynamics, creation of new materials, etc, since it can create an extremely high-pressure state in very short time. Of many different types of ballistic ranges developed to date, two-stage light gas gun is being employed most extensively. In the present study, a theoretical work has been made to develop a new type of ballistic range which can easily simulate a flying projectile. The present ballistic range consists of high-pressure tube, piston, pump tube, shock tube and launch tube. The effect of adding a shock tube in between the pump tube and launch tube is investigated. This improvement is identified as the reduction in pressures in the high pressure tube and pump tube while maintaining the projectile velocity. Equations of motions of piston and projectile are solved using Runge-Kutta methods. Dependence of projectile velocity on various design factors such as high pressure tube pressure, piston mass, projectile mass, area ratio of pump tube to launch tube and type of driver gas in the pump tube are also analyzed. Effect of various gas combinations is also investigated. Calculations show that projectile velocities of the order 8 km/sec could be achieved with the present ballistic range.

Development and Characteristics of the x-ray transmission anode tube for the thickness measurement of film (필름 두께 측정용 투과 양극형 x-ray tube의 개발 및 특성)

  • Kim, Sung-Soo;Kim, Do-Yun
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.240-246
    • /
    • 2008
  • The x-ray transmission anode Ag-target tube was developed to apply for the thickness measurement of film in the thickness range of several tens$\sim$several hundreds ${\mu}m$ and its characteristics were evaluated. The energy distribution and dose of x-ray from Ag-target tube was investigated at the tube voltage near 10 kV, and discussed in comparition with that from W-target tube. The energy distribution and dose of x-rays passing through film were measured with various thickness of Ny and PP film. From these results, it was confirmed that our x-ray tube can be applied for the thickness measurement of film.

Evaluation on the Performance of Design Parameters in Earth Tube System (지중튜브시스템 주요 설계 변수의 성능 평가)

  • Hwang, Yong-Ho;Hwang, Seok-Ho;Choi, Jeong-Min
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.3
    • /
    • pp.87-94
    • /
    • 2016
  • Earth tube system can be installed in many ways. However, performance data on earth tube system is still insufficient. Therefore, in this study seven design parameters of earth tube systems were chosen such as underground earth tube length, depth, tube thermal conductivity, thickness, radius, soil conditions, and fan type. And the change effects in the values of the seven parameters on earth tube exit temperatures and heat transfer rate were examined through Energyplus simulations.

Verification Experiment of a Water-to-air Ground Source Multi-heat Pump System (물-공기 지열 멀티형 열펌프 시스템 실증연구)

  • Kim, Cheol-Woo;Kim, Byoung-Kook;Lee, Pyeong-Gang;Lim, Hyo-Jae;Kang, Shin-Hyung;Choi, Jong-Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.1
    • /
    • pp.9-16
    • /
    • 2010
  • The aim of this study is to verify the performance of water-to-air multi-heat pump system with a vertical U-tube GLHX(U-tube system) and a double tube GLHX(double tube system), which were installed in a school building located in Asan. For analyzing the performance of the GSHP system, we monitored various operating da~ including the water temperature of inlet and outlet of the ground heat exchanger, mass flow rate, and power consumption. Daily average COP of the single U-tube system and the double tube system were 4.5 and 4.2 at cooling mode and were 3.5 and 3.8 at heating mode. As a result, We know that performance of water-to-air multi-heat pump unit is reliable at actual condition operated in a part load conditions for all day.

Behavior of Geotextile Tube by Plane Strain Analysis and 3-Dimensional Finite Element Method (평면변형해석과 3-D FEM 기법을 통한 지오텍스타일 튜브의 거동해석)

  • 신은철;오영인
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.233-241
    • /
    • 2003
  • Geotextile tube is hydraulically filled with dredged materials and has been applied to coastal protection and scour protection, dewatering method of slurry, and isolation of contaminated material. Recently, geotextile tube technology is no longer alternative construction technique but suitable desired solution. In this paper, the numerical analysis was performed to investigate the behavior of geotextile tube with various properties of geotextile sheet and hydraulic pumping conditions. Numerical analysis was executed to compare with the results from the large-scale field model tests, and also with those of plane strain analysis and 3-D FEM analysis. A geotextile tube was modeled using the commercial finite element analysis program ABAQUS and the one-quarter of tube was modeled. Behavior of geotextile tube during the hydraulic pumping procedure was analyzed by comparing the large-scale field model test and numerical analysis. The shape variation and maximum tube height between the numerical analysis results and large-scale filed test results are turned out to be in a good agreement.