The natural refrigerants have used into HVAC equipments because the CFCs and HFCs have some environmental problems like high ODP and GWP. The carbon dioxide has small effect on the environmental problem but also good thermodynamics properties. In this study, the simulation study on the performance and characteristics of a $CO_2$ gascooler and evaporator using a fin-tube and microchannel heat exchanger has been conducted. Besides, the comparison of performance with operating condition was carried out in order to apply to the $CO_2$ heat pump system. As a result, the front sizes of a gascooler and evaporator using a microchannel were decreased by 63% and 58%, respectively, compared to those using a fin-tube. The performance of the fin-tube gascooler and evaporator were more responsive to the variation of operating conditions compared to that of microchannel. The pressure drop of a fin-tube heat exchanger was higher than that of a microchannel one.
Keywords
Capacity; Evaporator; Gascooler; Pressure drop;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Churchill, S., 1997, Friction factor equation spans all fluid flow regimes, Chem Eng., Vol 7, pp. 91-92.
2 Wang, C. C., 2001, Acomparative study of compact enhanced fin-and-tube heat exchangers, Int. J. of heat and mass transfer, Vol. 44, pp. 3565-3573.   DOI   ScienceOn
3 Yoon, S. H., Cho, E. S. and Kim, M. S., 2004, Characteristics of evaporative heat transfer and pressure drop of carbon dioxide and correlation development near the critical point, Proceeding of the SAREK, Vol. 16, No. 6, pp. 530-534.
4 Yun, R., 2002, Convective boiling cf carbon dioxide in mini tubes and micro channels, PH thesis, Korea University, Seoul, Korea.
5 Domanski, P. A, 1989, EVSIM-An evaporator simulation model accounting for refrigerant and one dimensional air, NIST, IR-89-4133.
6 J.H. Lee, S. W. Bae, K H. Bang and M. H. Kim, 2002, Experimental and numerical reaserch on condenser performance for R22 and R407C refrigerants, Int J. of Refrigeration, Vol. 27, pp. 372-3826.
7 Gnielinski, V., 1976, New equation for heat and mass transfer in turbulent pipe and channel flow, Chem Eng., Vol. 16, pp. 359-368.
8 Beaver, A. C., Yin, J. M., Bullard, C. W., and Hrnjak, P. S., 1999, An experimental investigation of transcritical carbon dioxide systems for residential air conditioning, ACRC, CR-18.
9 Lee, H. J., Lee, S. Y., 2001, An experimental study on pressure drop of boiling flow within horizontal rectangular channels with small heights, Transactions of the KSME, Vol. 25, No. 9, pp. 1219-1226.
10 Kirn, M H., Bullard, C. W., 2001, Development of a microchannel evaporator model for a $CO_{2}$ air-conditioning system, Energy, Vol. 26, pp. 931-948.   DOI   ScienceOn
11 Kirn, Y., 2002, Development of outdoor heat exchanger and components for cooling/heating system using $CO_{2}$, 2nd Report, Ministry of Commerce, Industry and Energy, pp. 194-223.
12 Yin, J. M., Bullard, C. W., Hrnjak, P. S., 2001, R-744 gas cooler rnodel development and validation, Int. J. of Refrigeration, Vol. 24, No. 7, pp. 692-701.   DOI   ScienceOn
13 Pettersen, J., Hafner, A., Skaugen, G., 1998, Development of compact heat exchangers for $CO_{2}$ air-conditioning systems, Int. J of Refrigeration, Vol. 21, pp. 180-193.   DOI   ScienceOn