• Title/Summary/Keyword: CO tube

Search Result 809, Processing Time 0.026 seconds

Soot Concentration and Temperature Measurements in Laminar Ethylene Jet Double-concentric Diffusion Flames (동축 이중 에틸렌 확산화염의 매연 농도분포 및 온도 측정)

  • Lee, Gyo-U;Jeong, Jong-Su;Hwang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.402-409
    • /
    • 2002
  • Experiments were performed with double-concentric diffusion flame(DDF) in order to investigate the characteristics of soot formation and temperature distributions. The flame size and shape of the DDF are similar to those of the well-known normal co-flow diffusion flame(WF), except the formation of a tiny inverse flame near the central tube exit. A laser light extinction technique was used to measure the soot volume fractions. The temperature distributions in the flame were measured by rapid insertion of a R-type thermocouple. Soot concentrations along the flame axis of the DDF were higher than those of the NDF. However, the maximum soot volume fraction of the DDF along the periphery of the flame was lower than that of the NDF. It is mainly due to the effect of nitrogen-dilution from the inner air. Measured temperature distribution explains these trends of soot concentration. The temperature along the flame axis was also higher in DDF than that of the NDF. However, the flame temperatures at the flame front of the two flames were almost same regardless of the inner flame. This phenomenon means that the inverse flame inside the DDF did not affect on the flame structure including the temperature and soot concentration, except the region around the flame axis.

Studies on the Sex Control in Swine by the Physical Treatments on spermatozoa (정자에 대한 심리적 처리에 의한 돼지의 성비조절에 관한 연구)

  • 이용빈;임경선;서국성;오성종
    • Korean Journal of Animal Reproduction
    • /
    • v.3 no.1
    • /
    • pp.36-40
    • /
    • 1979
  • This experiment was conducted to separate X-and Y-bearing spermatozoa of boar semen. The ratio of X-and Y-bearing spermatozoa to total spermatozoa included in ejaculated semen obtained from 4 boars raising at the College of Agriculture, Seoul National University and treated by the sedimentory or electrophoretic technique was estimated. For the electrophoresis, the semen specimen was placed into the co, pp.r loop electrodes in 30cc of glass tube at room temperature for 30 minutes and in order to sedimentary separation, the semen was sedimented in 5$^{\circ}C$ water for 50 minutes. The sperm fluorescent stainning technique was performed by the method of Bhattacharya etal (1976). The results obtained were as follows; 1. Average rate of B-body bearing spermatozoa in normal boar semen was 45.15${\pm}$4.20%, and no significant difference was observed between 1st (44.88${\pm}$6.41%) and 2nd (42.75${\pm}$4.17%) fraction of fractionally collected semen. 2. Spermatozoa were separated into several different fractions by sedimentation. B-body a, pp.arances from the top and bottom fraction were 53.70% and 33.43%, respectively. There were highly significant difference between the top and bottom fractions. 3. The swine spermatozoa were separated into X-and Y-bearing spermatozos by electrophoresis without interferring the sperm motility. The rates of B-body bearing spermatozoa attracted on the anode and cathode were 60.4% and 21.8%, respectively. Highly significant difference betwee two fractions was also observed.

  • PDF

Scintillation Properties of Acrylate Based Plastic Scintillator by Photoploymerization Method (아크릴레이트 기반 광중합 플라스틱 섬광체의 섬광 특성)

  • Kim, Sunghwan;Lee, JoonIl
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.637-642
    • /
    • 2016
  • In this study, we prepared and characterized a acrylate based UV-curable plastic scintillator. It was used co-polymers TMPTA, DHPA and Ultima $Gold^{TM}$ LLT organic scintillator. The emission spectrum of the plastic scintillator was located in the range of 380~520 nm, peaking at 423 nm. And the scintillator is more than 50% transparent in the range of 400~800 nm. The emission spectrum is well match to the quantum efficiency of photo-multiplier tube and the fast decay time of the scintillation is 12 ns, approximately. This scintillation material provides the possibility of combining 3D printing technology, and then the applications of the plastic scintillator may be expected in human dosimetry etc.

Change of End-tidal PCS During Cardiopulmonary Bypass (체외순환시 호기말 이산화탄소압의 변화)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.25 no.12
    • /
    • pp.1399-1403
    • /
    • 1992
  • The evaluation of the effectivess of ongoing cardiopulmonary resucitation efforts is dependent on the commonly used methods, such as the presence of femoral or carotid artery pulsations, arterial blood gas determinations, peripheral arterial pressure and intracardiac pressure monitoring. But recent studies suggest that end-tidal carbon dioxide tension serves as a non-invasive measurement of pulmonary blood flow and therefore cardiac output under constant ventilation. A prospective clinical study was done to determine whether end-tidal carbon dioxide monitoring in open heart surgery under cardiopulmonary bypass could be used as a prognostic indicator of bypass weaning. We monitored end-tidal PCO2 values continuously during cardiopulmonary bypass in 30 patients. "Ohmeda 5210 CO-2 monitor" under infrared absorption method were incorperated into the ventilator circuit by means of a side point adaptor between endotracheal tube and ventilator tubing. 18 patients[Group I ] were res-ucitated from partial bypass followed by aorta cross clamp off and 12 patients[Group II ] from aorta cross clamp off followed by partial bypass. But there was no difference between two groups[p>0.05]. The value of end-tidal carbon dioxide tension during ventricular fibrillation or nearly arrest state was 6.6$\pm$2.9 mmHg, and at the time of spontaneous beating was 19.3$\pm$5.6 mmHg[Mean$\pm$Standard deviation], In conclusion end-tidal carbon dioxide tension monitoring provides clinically useful, continous, noninvasive and supplementary prognostic indicator during cardiopulmonary bypass weaning procedures.rocedures.

  • PDF

Diagnosis of cracking in T23 welds for power plant application (보일러용 고강도 T23강의 용접부 손상 원인 분석)

  • Park, Ki-Duck;Ahn, Jong-Suk;Shin, Dong-Hyeok;Lee, Chang-Hee
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.61-61
    • /
    • 2009
  • This paper has been performed in order to figure out the reason of failure in T23 weldments used for boiler tube at 550 $^{\circ}C$. Defects such as cracks and cavities occurred in CGHAZ (coarse grain heat-affected-zone) and multi pass of weld metal, and these crack propagated along grain boundary. Microstructure evolution such as grain growth and carbide precipitation was investigated by optical microscope (OM), transmission electron microscope(TEM). Moreover, Auger electron spectroscope (AES) was employed in order to examine segregation along the grain boundaries. There is significant difference in grain size and precipitation distribution in the region where cracking took place. In addition, sulfur segregation was observed. Based on the results of this investigation, it has been possible to establish that this type of cracks were consistent with reheat cracking and creep damage. Selection of optimal filler metal, heat input, and PWHT temperature is required for prevention in order to avoid this type of cracking.

  • PDF

High Productivity Ethanol Fermentation Using Flocculant Yeast (응집성 효모에 의한 고생산성 알콜 발효)

  • 손석민;김인규;변유량
    • Microbiology and Biotechnology Letters
    • /
    • v.20 no.5
    • /
    • pp.607-613
    • /
    • 1992
  • A tower fermentor equipped with a modified settler was used for ethanol fermentation using highly flocculating yeast, Saccharomyces uvarum. The settler was constructed of glass column divided into two chambers by a funnel shaped divider. Gas was allowed to escape from lower chamber of the settler through a small tube. This design significantly reduced the turbulence in upper chamber of the settler and made it possible to operate at high dilution rate. Using the tower fermentor, the effects of operating conditions such as initial glucose concentration, dilution rate and cell recycle ratio were studied. The maximum ethanol productivity, 64.0 g/l' h was obtained at a dilution rate 1.1 h -1 and a cell recycle ratio 5 with the corresponding ethanol concentration of 58.8 g/l, and cell mass of 88 g/l.

  • PDF

Biological performance evaluation of tubular subsurface cage system for sea cucumber, Apostichopus japonicus, grow-out by in-situ tests (해상 실험에 의한 침하식 해삼 양성 기구의 생물학적 성능 평가)

  • Oh, Moo-Hwan;Kwon, Inyeong;Kim, Taeho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.2
    • /
    • pp.202-213
    • /
    • 2014
  • The sea cucumber, Apostichopus japonicus, is becoming an important aquaculture species in China, Japan and Korea. The purpose of this study is to evaluate the biological performance of a tubular type of subsurface cage for sea cucumber grow-out by in-situ tests. The cage structure was constructed of PP (polypropylene) frames and PP tubes (${\phi}130mm{\times}24pieces$). A set of tests were conducted at a depth of 15 m near Seosaeng, Ulsan, Korea for 295 days (23 July, 2012 to 13 May, 2013). A total of 155 sea cucumbers were used and fed a mixed diet containing mud, mineral, wheat, fish meal, etc (3% of their body weight). At the end of the experiments, sea cucumber showed a higher survival rate in feed shelter (77.14%) rather than no feed shelter (64.71%). The specific growth rate (SGR) of sea cucumbers in feed condition (0.04% $day^{-1}$) was higher than that of no feed culture animals (-0.49% $day^{-1}$) during total experimental periods. The result was able to find a no significance difference in survival rate but a significance difference in SGR under feed and no feed treatments.

Development of Algorithm for Stereoscopic PIV using Normalized Cross-correlation (정규상호상관도를 이용한 입체 입자영상유속계 알고리즘 개발)

  • Oh, Jung-Keun;Kim, Yoo-Chul;Ryu, Min-Cheol;Koh, Won-Kyou;Suh, Jung-Chun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.44 no.6
    • /
    • pp.579-589
    • /
    • 2007
  • Contrary to the conventional single-point measuring devices such as LDV, pitot-tube, hot-wire, etc., it would be possible to measure instantaneously 3-D flow fields with a stereoscopic PIV system. In this paper, we present an analysis algorithm for a stereoscopic PIV system using the normalized cross-correlation (NCC) and a 3-D calibration based reconstruction method. The evaluation method based on NCC is one of the most accurate correlation-based methods. We validated the developed algorithm through a benchmarking comparison with 3-D artificial SPIV images and calibration target images.

Evaluation of Thermal Conductivity for Grout/Soil Formation Using Thermal Response Test and Parameter Estimation Models (열응답 시험과 변수 평가 모델을 이용한 그라우트/토양 혼합층의 열전도도 산정)

  • Sohn Byong Hu;Shin Hyun Jun;An Hyung Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.2
    • /
    • pp.173-182
    • /
    • 2005
  • The Performance of U-tube ground heat exchanger for geothermal heat Pump systems depends on the thermal properties of the soil, as well as grout or backfill materials in the borehole. In-situ tests provide a means of estimating some of these properties. In this study, in-situ thermal response tests were completed on two vertical boreholes, 130 m deep with 62 mm diameter high density polyethylene U-tubes. The tests were conducted by adding a monitored amount of heat to water over a $17\~18$ hour period for each vertical boreholes. By monitoring the water temperatures entering and exiting the loop and heat load, overall thermal conductivity values of grout/soil formation were determined. Two parameter estimation models for evaluation of thermal response test data were compared when applied on the same temperature response data. One model is based on line-source theory and the other is a numerical one-dimensional finite difference model. The average thermal conductivity deviation between measured data and these models is of the magnitude $1\%$ to $5\%$.

Rapid Determination of L-carnitine in Infant and Toddler Formulas by Liquid Chromatography Tandem Mass Spectrometry

  • Ahn, Jang-Hyuk;Kwak, Byung-Man;Park, Jung-Min;Kim, Na-Kyeoung;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.34 no.6
    • /
    • pp.749-756
    • /
    • 2014
  • A rapid and simple analytical method for L-carnitine was developed for infant and toddler formulas by liquid chromatography tandem mass spectrometry (LC-MS/MS). A 0.3 g of infant formula and toddler formula sample was mixed in a 50 mL conical tube with 9 mL water and 1 mL 0.1 M hydrochloric acid (HCl) to chemical extraction. Then, chloroform was used for removing a lipid fraction. After centrifuged, L-carnitine was separated and quantified using LC-MS/MS with electrospray ionization (ESI) mode. The precursor ion for L-carnitine was m/z 162, and product ions were m/z 103 (quantitative) and m/z 85 (qualitative), respectively. The results for spiked recovery test were in the range of 93.18-95.64% and the result for certified reference material (SRM 1849a) was within the range of the certificated values. This method could be implemented in many laboratories that require time and labor saving.