• Title/Summary/Keyword: CO tube

Search Result 813, Processing Time 0.027 seconds

Development of Direct Measurement Device for Alveolar Breath Carbon Monoxide

  • Jo, Wan-Kuen;Oh, Jee-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E4
    • /
    • pp.181-190
    • /
    • 2002
  • A novel portable device for the direct measurement of alveolar breath carbon monoxide (CO) was developed. The major components of the device include a mouthpiece, non-rebreathing two-way valve, Teflon tube, and CO dosimeter. An alveolar CO measurement can be completed within 1.5 min when using the proposed device and measurement protocol. Measurements could be read to the nearest 0.1 ppm. Humidity did not influence the CO measurements taken by the CO dosimeter, plus there were no problems associated with the recovery and carryover of CO through the device. The criterion for significance in statistical analyses was p< 0.05. The average recovery was 103 and 99% for recovery and carryover experiments, respectively. Test results using the proposed alveolar CO measurement system reflected a good reproducibility. This reproducibility was also supported by the finding that the relative standard deviations (RSDs) of the data sets were less than 7% for the loss experiment and less than 8% for the carryover experiment. Consequently, it would appear that the proposed device can be effectively applied to measure CO levels found in breath, thereby overcoming several disadvantages associated with the conventional bag and adsorbent tube sampling methods.

A Survey on Patient Dose and Exposure Conditions in Simple Radiography of the Abdomen (복부 단순 X-선 촬영조건과 환자 피폭에 관한 조사 연구)

  • Kim, Sung-Soo;Lee, Sun-Sook;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.19 no.2
    • /
    • pp.59-65
    • /
    • 1996
  • We studied exposure techniques and exposure dose for simple abdomen A-P projection for 41 medical facilities that are located in Seoul area. 1. The range of tube voltage used was 60 to 84 kVp, the average tube voltage used was 74 kVp 2. Only 17% of added filter was used. 3. Tube current mostly used was 200 mA, some of them used 400 mA. 4. The grid ratio mostly was used 10 : 1, 54 % of the rare earth screen was used in most facilities. 5. The average skin entrance dose was 4.15 mSv and the dose range was 1.05 mSv to 11.0 mSv.

  • PDF

An Experimental Study on Performance of Heatproof Silicon at the Connector of Boiler Exhaust Tube (배기통과 가스보일러 접속부의 내열실리콘 성능에 관한 실험적 연구)

  • Leem, Sa-Hwan;Lee, Jong-Rark;Kim, Cheol-Jin;Han, Gwi-Ho;Kim, Yong-Joo;Kim, Hee-Soo;Jang, Won-Suk;Lim, Cheong-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.91-97
    • /
    • 2007
  • Recently, during the past five years, accidents of gas boiler using city gas have occurred 7.4 times more than those which use LP gas. The number of accidents has increased since the use of city gas boilers has increased. These boiler accidents resulted in 87% death from poisoning of CO, and casualty of the accidents was 4.3 times more than that of other types of accident. Hence this study makes the cause of accidents clear by separation the exhaust tube which is the cause of CO poisoning. Also, this study will establish the safety of heat-resistant silicon through testing the performance of heat-resistant silicon. The experiment showed that common silicon started hardening at $56^{\circ}C$ while the heat-resistant silicon did not begin carbonization until $606^{\circ}C$. Besides at the temperature of $150^{\circ}C$ which is the normal temperature of exhaust tube, common silicon leaked on the pneumatic test after deterioration, but the heat-resistant silicon maintained its original property. With these results, we judge that we can reduce the casualty by CO poisoning if we use the heat-resistant silicon to the connector of he exhaust tube.

  • PDF

Fresh Produce Container Operated with a Routine of Hypobaric Application, CO2 Injection and Diffusion Tube Opening for Keeping Beneficial Modified Atmosphere

  • Park, Su Yeon;An, Duck Soon;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.26 no.2
    • /
    • pp.53-60
    • /
    • 2020
  • A concept of household container to create and keep the modified atmosphere (MA) beneficial for fresh produce mix was devised and tested under typical chilled storage conditions of 3℃. The container system containing mixed products is initialized by applying weak hypobaric condition (0.9 atm) and subsequently injecting CO2 gas at an appropriate low level (0.03 atm). The passive atmosphere modification by produce respiration is then induced to reach a target until gas diffusion tube of proper dimension starts to open. The design was made to attain quasi-steady state mass balance of O2, CO2 and N2 to maintain the desired MA through the storage. Interrupted opening for taking out or placing some products was to reinitialize the loop of control logic. The developed concept was tested by the container which held commodities of spinach, pak choi, oyster mushroom, peeled onion, strawberry and cut carrot. The target optimum MA of 11% O2 and 10% CO2 (0.11 and 0.10 atm, respectively) was set to avoid injurious range of O2 and CO2 concentrations for any commodities. The developed container system could work to reach and maintain beneficial MA of 0.10-0.12 atm O2 and 0.07-0.10 atm CO2 close to the target during the storage contributing to quality retention of products measured in weight loss, chlorophyll content of spinach, ascorbic acid content of pak choi, color of onion, texture of oyster mushroom, bacterial count of strawberry and carotenoids of carrot. The container system shows potential to improve current preservation practice of fresh produce mix on consumers' level.

Analysis of Heat Transfer and Pressure Drop During Gas Cooling Process of Carbon Dioxide in Transcritical Region (초임계 영역내 $CO_2$ 냉각 열전달과 압력강하 분석)

  • 손창효;이동건;정시영;김영률;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.65-74
    • /
    • 2004
  • The heat transfer coefficient and pressure drop of $CO_2$(R-744) during gas cooling Process of carbon dioxide in a horizontal tube were investigated experimentally and theoretically. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop consist of a receiver. a variable-speed pump. a mass flowmeter, an evaporator. and a gas cooler(test section). The main components of the water loop consist of a variable-speed Pump. an constant temperature bath. and a flowmeter. The gas cooler is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus The test section consists of smooth, horizontal stainless steel tube of 9.53 mm outer diameter and 7.75 mm inner diameter. The length of test section is 6 m. The refrigerant mass fluxes were 200 ~ 300 kg/($m^2{\cdot}s$) and the inlet pressure of the gas cooler varied from 7.5 MPa to 8.5 MPa. The main results were summarized as follows : The predicted correlation can evaluated the R-744 exit temperature from the gas cooler within ${\pm}10%$ for most of the experimental data, given only the inlet conditions. The predicted gas cooley capacity using log mean temperature difference showed relatively food agreement with gas cooler capacity within ${\pm}5%$. The pressure drop predicted by Blasius estimated the pressure drop on the $CO_2$ side within ${\pm}4.3%$. The predicted heat transfer coefficients using Gnielinski's correlation evaluated the heat transfer coefficients on the $CO_2$ side well within the range of experimental error. The predicted heat transfer coefficients using Gao and Honda's correlation estimated the heat transfer coefficients on the coolant side well within ${\pm}10\;%$. Therefore. The predicted equation's usefulness is demonstrated by analyzing data obtained in experiments.

Experimental study on characteristics of evaporation heat transfer of $CO_2$ in horizontal micro-channel tube (수평 다채널관 내 이산화탄소의 증발 열전달 특성에 관한 실험적 연구)

  • Lee, Sang-Jae;Kim, Dae-Hoon;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2200-2205
    • /
    • 2007
  • In order to investigate the variation on a heat transfer coefficient during evaporation of $CO_2$, basic experiment on the evaporation heat transfer characteristics in a horizontal micro-channel tube was performed. Hydraulic diameters of micro-channels were 0.68 and 1.46 mm. The experiment apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiments were conducted for various mass fluxes of 300 to 800 kg/$m^2s$, heat fluxes of 10 to 40 kW/$m^2$ and saturation temperatures of -5 to 5$^{\circ}C$. With the increase heat flux, the evaporation heat transfer coefficient increased. And the significantly change of the heat transfer coefficient was observed at any heat flux and mass flux. As the saturation temperature increased and the hydraulic diameter decreased, the heat transfer coefficient increased.

  • PDF