• 제목/요약/키워드: CO laser

검색결과 1,347건 처리시간 0.024초

Combination Treatment of Nd:YAG Picosecond-domain Laser and Fractional CO2 Laser for Contracted Neck Scar with Hyperpigmentation

  • Choi, Woo Jung;Park, Eun Soo;Tak, Min Sung;Kang, Sang Gue
    • Medical Lasers
    • /
    • 제10권1호
    • /
    • pp.52-54
    • /
    • 2021
  • There is growing interest in minimizing postoperative scarring after a thyroidectomy. Among the many treatment types, laser therapy, especially picosecond-domain laser therapy, is accepted as a standard method. In the present case, a patient with a pigmented, contracted scar was treated using the combination of a picosecond laser and ablative fractional (AF) CO2 laser. After 15 sessions of 1,064-nm picosecond with micro lens array (MLA) and AF CO2 laser application, the patient showed significant improvement in their pigmented lesions and scar contracture with no noticeable side effects for 16 months. These results suggest that a combination of picosecond laser with MLA and AF CO2 laser can treat pigmented, contracted scars safely and effectively.

레이저에 의한 誘雷의 기초적 연구 -${CO}_{2}$ 레이저에 의한 플라즈마 채널 발생- (Basic study on laser triggered lightning : The generation of plasma channel by ${CO}_{2}$ laser)

  • 장용무;강형부
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.289-293
    • /
    • 1996
  • The basic study on laser triggered lightning was carried out for the active protection of lightning in power transmission system. The lengths of generated plasma channels were simulated numerically for variations of energy and pulse width of CO$_{2}$ laser by Runge-Kutta-Gill method. As results, the effective lengths of plasma channels were 2.3m, 2.67m and 3.4m respectively for energy of 45J, 60J and 100J of CO$_{2}$ laser pulse with pulse width of 50nsec using focusing mirror with focal length of 10m. And also the effects of pulse width of first pulse and tail pulse of CO$_{2}$ laser on the length of plasma channel were examined.

  • PDF

$CO_2$ Laser Absorption Measurement of $CH_3CH_2Br$ using Photoacoustic Method

  • Jang Soo Shin;Kyung Hoon Jung;Cheol Jung Kim
    • Bulletin of the Korean Chemical Society
    • /
    • 제13권5호
    • /
    • pp.553-556
    • /
    • 1992
  • The ${CO}_2$ laser absorption measurement of ${CH}_3{CH}_2Br$ utilizing photoacoustic (PA) technique was performed using a cw and a pulsed ${CO}_2$ lasers. The absorption profile in the ${CO}_2$ laser wavelength region (9-10 ${\mu}$m) and the macroscopic small signal absorption cross section at 10P(20) (10.59 ${\mu}$m, 944 $cm^{-1}$) laser line were measured using a cw ${CO}_2$ laser. The laser fluence dependence on infrared multiphoton absorption (IRMPA) was also studied with a pulsed TEA ${CO}_2$ laser at 10P(20) laser line. In view of monotonic increase of PA signal with the rise of laser fluence, it was suggested that the anharmonicity in pumped vibration mode did not restrict ir multiphoton absorption in ${CH}_3{CH}_2Br$ system as found in large molecular system.

액체질소 냉각형광대역 cw CO 레이저 (A $LN_2$-cooled, Broadband cw CO Laser)

  • 김용평;최종운;원종욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.667-671
    • /
    • 1989
  • The CO laser is one of powerful light source for laser magnetic resonance spectroscopy in the mid-infrared region of the spectrum because of its wideband operational characteristics. In this work, a liquid nitrogen cooled cw CO laser is developed to allow broad-band operation from 5 to 8 ${\mu}m$. The design details will be presented.

  • PDF

Histological Change and Collagen Formation on Laser Wounded Rat using 808 nm Diode Laser and $CO_2$ Laser

  • ;;;안진철
    • 대한의생명과학회지
    • /
    • 제15권1호
    • /
    • pp.81-86
    • /
    • 2009
  • Lasers are necessity in our life related to the fields of medicine and cosmetic surgery. With 808 nm diode laser and $CO_2$ laser, we made some wounds on a dorsum of rat by laser irradiation. All of irradiations shows thermal effects on the whole region of skin tissues. They make wound damage depending on laser power and irradiation time. Because a collagen is plays an important role in tissue repair, we studied collagen accumulation in wound tissue. For wound healing, collagen accumulation was found in the near region of damage in epidermis and dermis layer of the rat skin. In case of the quantitative analysis of collagen in wound tissue, the amount of collagen in wound tissue by $CO_2$ laser irradiation is higher than that of 808 nm diode laser irradiation. And re-epithelialization was significantly faster in wound by $CO_2$ laser irradiation compared with that of 808 nm diode laser irradiation.

  • PDF

$CO_2$ Laser와 Scalpel을 이용한 절개 시 돼지 자궁에서의 창상 치유 평가 (Comparative Study of Wound Healing in Porcine Uterus with $CO_2$ Laser and Scalpel Incisions)

  • 이재연;박창식;조성환;정성목;김명철
    • 한국임상수의학회지
    • /
    • 제26권6호
    • /
    • pp.563-567
    • /
    • 2009
  • Steel scalpel과 $CO_2$ laser를 이용한 돼지 자궁 절개 시 창상 치유에 미치는 영향을 평가하고자 본 실험을 실시하였다. 다섯 마리의 Landrace - Yorkshire 혼혈 종 돼지를 이용하였고, 각각의 돼지에서 좌측 및 우측의 자궁에 대칭적으로 scalpel과 $CO_2$ laser를 이용하여 절개 하였다. 각각의 기구는 절개 속도, 절개의 용이성 및 출혈 정도를 평가 하였으며 수술 후 21일에 육안적인 유착 정도와 조직학적 검사를 실시하였다. Scalpel을 이용한 절개는 레이저를 이용한 절개보다 용이하였으나 두 군간의 유의성은 없었다. 레이저를 이용한 절개 시 출혈량은 적었으나 절개속도는 scalpel을 이용한 경우가 빨랐다. $CO_2$ laser 절개에서의 수술 후 자궁 유착은 scalpel 절개에서 보다 적게 발생하였다. 조직학적 검사에서 scalpel 절개의 경우 상피 조직과 자궁내막선의 재생이 완전히 이루어 졌으나 레이저를 이용한 경우 불완전한 재생 상태를 보였다. 비록 scalpel을 이용한 절개가 $CO_2$ laser를 이용한 경우 보다 조직 손상이 적었으며 사용하기 용이하였으나 출혈이 많은 단점이 있다. 반면 $CO_2$ laser를 이용한 절개의 경우 지혈 효과는 좋으나 창상 치유를 지연 시켰다.

화염증 CO2 Laser를 이용한 입자의 크기 및 형상 제어 (Control of Size and Morphology of Particles Using CO2 Laser in a Flame)

  • 이동근;이선재;최만수
    • 대한기계학회논문집B
    • /
    • 제23권11호
    • /
    • pp.1379-1389
    • /
    • 1999
  • A new technique for control of size and shape of flame-made particles is Introduced. The characteristic sintering time can be controlled Independently of collision time by heating the particles with irradiation of laser because the sintering time strongly depends on temperature. A coflow oxy-hydrogen diffusion flame burner was used for $SiCl_4$ conversion to silica particle. Nanometer sized aggregates irradiated by a high power CW $CO_2$ laser beam were rapidly heated up to high temperatures and then were sintered to approach volume-equivalent spheres. The sphere collides much slower than the aggregate, which results in reduction of sizes of particles maintaining spherical shape. Light scattering of Ar ion laser and TEM observation using a local sampling device were used to confirm the above effects. When the $CO_2$ laser was irradiated at low position from the burner surface, particle generation due to gas absorption of laser beam occurred and thus scattering intensity increased with $CO_2$ laser power. At high irradiation position, scattering intensity decreased with $CO_2$ laser power and TEM image showed a clear mark of evaporation and recondensation of particles for high $CO_2$ laser power. When the laser was irradiated between the above two positions where small aggregates exist, average size of spherical particles obviously decreased to 58% of those without $CO_2$ laser irradiation with the spherical shape. Even for increased carrier gas flow rate by a factor of three, TEM photograph also revealed considerable reduction of particle size.

CO2 Laser와 Scalpel을 이용한 절개 시 돼지 방광에서의 창상치유 평가 (Comparative study of wound healing in porcine urinary bladder with CO2 laser and scalpel incisions)

  • 이재연;정성목;조성환;박창식;김명철
    • 대한수의학회지
    • /
    • 제50권3호
    • /
    • pp.247-251
    • /
    • 2010
  • This study compared the instrument performance and tissue healing of a steel scalpel with a $CO_2$ laser in an animal urinary bladder surgery model. Landrace and Yorkshire mixed breed pigs were used. Two symmetrical incisions were made in urinary bladder of each pig. One incision was made on the left side of ventral aspect on urinary bladder using a steel scalpel, while the other incision was performed on the right side using a $CO_2$ laser with an 8W output power. Each instrument was evaluated clinically for speed, ease of incision, and extent of bleeding. At 7 and 21 days after initial wounding, each wound was taken for histological observations. The scalpel was an easier instrument to use in the confines of the urinary bladder tissue, compared with the laser. However, there was no significant difference between the two groups. The amount of bleeding was less in the laser group but the time of the incisions was shorter with the scalpel. Scalpel incisions showed complete restoration of the epithelium and muscularis. On the other hand, the laser incisions showed incomplete restoration of the epithelium and muscularis. However, most of wound healing in the laser incisions was accomplished according to the time lapse. Although the scalpel produced less damage to the urinary bladder tissue and was easier to handle than the $CO_2$ laser, it did not provide hemostasis that was helpful for use on highly vascular tissue. The $CO_2$ laser provided good hemostasis, but delayed wound healing. In conclusion, the $CO_2$ laser provided better hemostasis and better surgical field than the scalpel. The $CO_2$ laser was used effectively in urinary bladder incision.

후두질환에서 경구강 $CO_2$ 레이저 미세수술 (Transoral $CO_2$ Laser Microsurgery for Laryngeal Lesions)

  • 이상준;정필상
    • 대한후두음성언어의학회지
    • /
    • 제21권2호
    • /
    • pp.112-120
    • /
    • 2010
  • Transoral $CO_2$ laser microsurgery has been widely used for various laryngeal diseases. Laser cordectomy for the management of early laryngeal carcinoma has advantages with regards to oncologic results, preservation of laryngeal functions, morbidity and cost in comparison to those of open surgery or radiation therapy. $CO_2$ laser is also applicable to benign vocal fold lesions such as nodules, polyps, cysts, reinke's edema, granulomas, papillomas, hemangiomas and glottis webs. $CO_2$ laser is suitable for microsurgery because it has small focus size and hemostatic effect. We should also recognize the risks of $CO_2$ laser for safe use.

  • PDF

Development of CO Laser-Arc Hybrid Welding Process

  • Lee, Se-Hwan
    • 한국레이저가공학회지
    • /
    • 제5권3호
    • /
    • pp.15-20
    • /
    • 2002
  • The principal obstacle to selection of a laser processing method in production is its relatively high equipment cost and the natural unwillingness of production supervision to try something new until it is thoroughly proven. The major objective of this work is focused on the combined features of gas tungsten arc and a low-power cold laser beam. In this work, the laser beam from a 7 watts carbon monoxide laser was combined with electrical discharges from a short-pulsed capacitive discharge GTA welding power supply. When the low power CO laser beam passes through a special composition shielding gas, the CO molecules in the gas absorbs the radiation, and ionizes through a process blown as non-equilibrium, vibration-vibration pumping. The resulting laser-induced plasma(LIP) was positioned between various configurations of electrodes. The high-voltage impulse applied to the electrodes forced rapid electrical breakdown between the electrodes. Electrical discharges between tungsten electrodes and aluminum sheet specimens followed the ionized path provided by LIP. The result was well-focused melted spots.

  • PDF