• Title/Summary/Keyword: CO Removal

Search Result 1,572, Processing Time 0.027 seconds

Characterization of CO2 Adsorption Process for a Water Removal from Coal (석탄 내 수분 제거를 위한 CO2 흡착 효과에 대한 연구)

  • SEUNGTAEK LEE;HAKDEOK KIM;JUHUN SONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.2
    • /
    • pp.115-120
    • /
    • 2024
  • In this study, the extent of water removal in the high-moisture coal was measured. The simplified adsorption model was developed to predict the extent of water removal. The water removal was observed to increase up to 25% at saturation condition of 25℃. The modeling work shows that adsorption contributes the water removal only by 3%, whereas other factors such as CO2 solubility and wettability would be responsible for the water removal.

The Effect of Mechanical Properties of Polishing Pads on Oxide CMP(Chemical Mechanical Planarization)

  • Hong, Yi-Koan;Eom, Dae-Hong;Kang, Young-Jae;Park, Jin-Goo;Kim, Jae-Seok;Kim, Geon;Lee, Ju-Yeol;Park, In-Ha
    • KSTLE International Journal
    • /
    • v.5 no.1
    • /
    • pp.32-35
    • /
    • 2004
  • The purpose of this study is to investigate the effects of the structure and mechanical properties of laser-processed pads on their polishing behavior such as their removal rate and WIWNU (within wafer non-uniformity) during the chemical mechanical planarization (CMP) process. The holes on the pad acted as the reservoir of slurry particles and enhanced the removal rate. Without grooves, no effective removal of wafers was possible. When the length of the circular-type grooves was increased, higher removal rates and lower wafer non-uniformity were measured. The removal rate and non-uniformity linearly increased as the elastic modulus of the top pad increased. Higher removal rates and lower non-uniformity were measured as the hardness of the pad increased.

[Retracted]Gas Mask Removal Efficiency of CO, HCl, HCN, and SO2 Gas Produced by Fire ([논문철회]화재용 방독면의 CO, HCl, HCN, SO2 연소생성물 제거효율)

  • Kong, Ha-Sung;Gong, Ye-Som;Kim, Sang-Heon
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.57-60
    • /
    • 2015
  • The removal efficiencies by elastic fire gas mask of toxic gases CO, HCl, HCN, and $SO_2$ produced by a fire have a key role in saving lives. The elastic fire gas mask comprises a visible window, elastic hood, gas purification canister, and air vent. It does not have hair or neck thongs, which makes it easy to use and put on quickly. This research examined the removal efficiency of toxic gases by such a mask. The removal efficiencies for CO with a background concentration of 2505.0 ppm were 99.99 and 99.98% after 3.5 and 8.5 min, respectively. The residual CO concentration was drastically increased after 8.5 min. The removal efficiencies for HCl, HCN, and $SO_2$ with background concentrations of 1003.0, 399.0, and 100.3 ppm, respectively, were 100% after 20 min.

Characterization of the Effects of Relative Humidity and Bed-depth on $CO_2$ Capture for Maximizing the Utilization Rate of Soda Lime Sorbent

  • Cho, Il-Hoon;Park, Guen-Il;Kim, Joon-Hyung;Hwang, Taek-Sung;Lee, Mi-Kyoung
    • Carbon letters
    • /
    • v.2 no.2
    • /
    • pp.113-119
    • /
    • 2001
  • The advanced method for $CO_2$capture is currently one of the most important environmental issues in worldwide and it is therefore necessary to have available technologies, which minimize the discharge of $CO_2$ including Carbon-14 from nuclear facilities into the atmosphere. A key aspect of this work is to provide the technically principal data required to improve a $CO_2$ removal system for the utilization of regenerative sorbent use, specifically include suggestions regarding its modified column design (parallel dual-bed assembly), stop-restart operation and the economic feasibility of sorbent use. The removal performance of soda lime and the effects of relative humidity (RH) and packing bed-depth (BD) on $CO_2$ removal were investigated. In a single-bed, it revealed that the utilization of soda lime for $CO_2$ removal at line velocity of 13 cm/sec and bed depth of 12 cm increased with the increased relative humidity up to 85%. However, in the parallel dual-bed assembly applied with the stop-restart operation, a maximum utilization rate of soda lime for $CO_2$ removal was obtained even at 55% of RH and 8 cm of BD, specifically the utilization rate of soda lime by using this $CO_2$ removal assembly was about two-fold superior to that in a single-bed.

  • PDF

Synergy Effect of Fe/ZSM-5 and Co-Pt/ZSM-5 for NOx removal (NOx제거를 위한 Fe/ZSM-5와 Co-Pt/ZSM-5의 상승 효과)

  • Kim, Jin-Gul;Yoo, Seung-Joon;Kim, Seong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2390-2395
    • /
    • 2009
  • In the condition of GHSV=$30000\;hr^{-1}$, $NO_x$ removal yield was higher as mole ratio of $SiO_2/Al_2O_3$ for Fe/ZSM-5 was lower regardless of preparation method such as CVD (chemical vapor deposition) and dry impregnation. In addition to this, Fe/ZSM-5 catalyst showed about 50% $NO_x$ removal yield between $350^{\circ}C$ - $400^{\circ}C$ while CO formed significantly. To remove newly formed CO over Fe/ZSM-5, Co-Pt/ZSM-5 was used in conjunction with Fe/ZSM-5 in the series and this demonstrated over 90% removal yield of both NOx and CO at $250^{\circ}C$ and GHSV=$30000\;hr^{-1}$.

Cobalt ferrite nanotubes and porous nanorods for dye removal

  • Girgis, E.;Adel, D.;Tharwat, C.;Attallah, O.;Rao, K.V.
    • Advances in nano research
    • /
    • v.3 no.2
    • /
    • pp.111-121
    • /
    • 2015
  • $CoFe_2O_4$ nanotubes and porous nanorods were prepared via a simple one-pot template-free hydrothermal method and were used as an adsorbent for the removal of dye contaminants from water. The properties of the synthesized nanotubes and porous nanorods were characterized by electron diffraction, transmission electron microscopy and x-ray powder diffraction. The Adsorption characteristics of the $CoFe_2O_4$ were examined using polar red dye and the factors affecting adsorption, such as, initial dye concentration, pH and contact time were evaluated. The overall trend followed an increase of the sorption capacity reaching a maximum of 95% dye removal at low pHs of 2-4. An enhancement in the removal efficiency was also noticed upon increasing the contact time between dye molecules and $CoFe_2O_4$ nanoparticles. The final results indicated that the $CoFe_2O_4$ nanotubes and porous nanorods can be considered as an efficient low cost and recyclable adsorbent for dye removal with efficiency 94% for Cobalt ferrite nanotubes and for Cobalt ferrite porous nanorods equals 95%.

Gas removal efficiency of air washer system according to pH of sprayed water (분무수 pH 변화에 따른 에어와셔의 가스제거 성능변화)

  • Nam, Seung-Baeg;Ha, Jong-Pil;Kim, Tae-Hyung;Moon, In-Ho;Cho, In-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.488-492
    • /
    • 2007
  • In this study, experiment was done to verify the relationship between sprayed water's pH and gas removal efficiency of the Air Washer system. The experiment was done with sprayed water's pH in between pH 4.7 to 7.7, and Ion Chromatography analysis was used to identify the system's gas removal efficiency. As a result, $NH_3$ is removal efficiency decreased under 50% above pH 7, and $SO_X$ and $NO_X$ removal efficiency decreased under pH 6. Through this research, the optimum pH operating condition of the Air Washer System was conformed to be in range between pH6 to pH6.5.

  • PDF

Influence of $CO_2$ Removal on the Performance of IGCC plant (IGCC 플랜트에서 $CO_2$ 제거가 성능에 미치는 영향)

  • Cha, Kyu-Sang;Kim, Young-Sik;Lee, Jong-Jun;Kim, Tong-Seop;Sohn, Jeong-Lak;Joo, Young-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.242-245
    • /
    • 2008
  • In the power generation industry, various efforts are needed to cope with tightening regulation on carbon dioxide emission. Integrated gasification combined cycle (IGCC) is a relatively environment friendly power generation method using coal. Moreover, pre-combustion $CO_2$ removal is possible in the IGCC system. Therefore, much effort is being made to develop advanced IGCC systems. However, removal of $CO_2$ may affect the system performance and operation through reduction of fuel gas supplied to the gas turbine. This study predicts system performance change due to $CO_2$ capture by pre-combustion process from the normal IGCC performance without $CO_2$ capture and presents results of design parametric analysis.

  • PDF

Phosphorus Removal from Wastewater by CaCO3 Media (탄산칼슘 담체를 이용한 폐수내의 인 제거)

  • Kim, Moon Ki;Park, Jae Hong;Lee, Kwang Hyun;Joo, Hyun Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.515-521
    • /
    • 2009
  • In this study, the applicability of $CaCO_3$ as a seed material for crystallization reaction was tested. $CaCO_3$ was ground to lesser than 425 mesh and was made to media mixed with binder. Batch experiment was to investigate the ${PO_4}^{3-}-P$ removal efficiency of different parameters such as $CaCO_3$ dosage and binder ratio, size, type and mass of media. In addition, the effect of phosphorus removal from wastewater was tested using a lab-scaled crystallization reactor. At the results of the batch test, phosphorus removals were improved with increasing $CaCO_3$ dosage and media mass but were decreased with increasing media size. Moreover, phosphorus removals were influenced by specific surface area but media type. The average T-P and ${PO_4}^{3-}-P$ removal efficiency in a lab-scaled crystallization reactor with $CaCO_3$ media for wastewater were shown to be 60.2% and 60.3% for 18 days of operation time.

Toluene Removal Using Surface Discharge Induced Plasma Chemical Process (연면방전 플라즈마를 이용한 톨루엔 처리에 관한 연구)

  • 부문자;봉춘근;김신도
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.4
    • /
    • pp.297-305
    • /
    • 1997
  • The experimental study by use of SPCP was fulfilled to remove toluene emitted from various industrial processes. First of all, discharge characteristic was experimented as the change of applied voltage and frequency. Then toluene removal characteristic was tested with the analysis of by-products. As a result, optimum electrical discharge condition was from 20.0 kHz to 25.0 kHz of frequency and from 3.5 kV to 4.0 kV of voltage range. The variation of applied voltage had a more important effect on the removal characteristic of toluene than the frequency variation. The toluene removal efficiency was proportioned to ozone concentration and retention time on discharge plate. It was dropped as increase of toluene concentration, but total treated volume of tolene per power consumption was high. The decomposed toluene was transformed to $CO, CO_2$ and particulates, and the rate of transformation to particulates was higher than CO and $CO_2$ at high toluene concentration. Particulates were increased from 0.017 $\mum$ to 0.3 $\mum$ range of size distribution.

  • PDF