• 제목/요약/키워드: CO Leak

검색결과 127건 처리시간 0.029초

국제공동연구 PARTRIDGE를 통한 확률론적 건전성 평가 기술 개발 현황 (Current Status of an International Co-Operative Research Program, PARTRIDGE (Probabilistic Analysis as a Regulatory Tool for Risk-Informed Decision GuidancE))

  • 김선혜;박정순;김진수;이진호;윤은섭;양준석;이재곤;박홍선;오영진;강선예;윤기석;박재학
    • 한국압력기기공학회 논문집
    • /
    • 제9권1호
    • /
    • pp.62-69
    • /
    • 2013
  • A probabilistic assessment code, PRO-LOCA ver. 3.7 which was developed in an international co-operative research program, PARTRIDGE was evaluated by conducting sensitivity analysis. The effect of some variables such as simulation methods (adaptive sampling, iteration numbers, weld residual stress model), crack features(Poisson's arrival rate, maximum numbers of cracks, initial flaw size, fabrication flaws), operating and loading conditions(temperature, primary bending stress, earthquake strength and frequency), and inspection model(inspection intervals, detectable leak rate) on the failure probabilities of a surge line nozzle was investigated. The results of sensitivity analysis shows the remaining problems of the PRO-LOCA code such as the instability of adaptive sampling and unexpected trend of failure probabilities at an early stage.

밀폐공간 및 강제환기공간에의 천연가스 고압분출 시 농도 확산분포 거동해석 (I) (The Diffusion Behavier Analysis Caused by High Pressure Natural Gas Leak in Enclosure with and without Ventilation System (I))

  • 하태웅;하종만;김은자
    • 한국가스학회지
    • /
    • 제16권4호
    • /
    • pp.23-31
    • /
    • 2012
  • 밀폐 공간 내의 천연가스 공급 시스템에서 가스 누설에 따른 재난을 방지하고 보다 안전한 설계를 하기 위해서는 누출된 천연가스의 확산거동을 이해하고 예측할 수 있는 기술이 필요하다. 본 연구에서는 CFD를 사용한 해석법을 제시하고, 기 수행된 British Gas Technology Co.의 실험결과와 비교하여 타당성을 제시하였다. 노즐에서의 분출유량 2D 해석 결과는 실험결과와 2.6% 이내로 잘 일치함을 보였다. 또한, 다양한 강제 환기 조건에 따른 가스 확산 특성을 비정상상태 3차원 CFD 해석을 수행한 결과 실험결과와 정성적인 경향이 잘 일치됨을 보였다.

파단전 누설 평가를 위한 Ramberg - Osgood 상수 결정법 (Determination Method of Ramberg-Osgood Constants for Leak Before Break Evaluation)

  • 배경동;류호완;김윤재;김진원;김종성;오영진
    • 대한기계학회논문집A
    • /
    • 제39권7호
    • /
    • pp.645-652
    • /
    • 2015
  • 본 논문은 이전 연구에서 제시한 여러 가지 Ramberg-Osgood 상수 결정법을 비교하여 파단전 누설평가에 사용되기 가장 적합한 상수 결정법을 선정하였다. 비교에 사용한 재료는 운전온도인 $316^{\circ}C$에서 실험한 SA312 TP316 과 SA508 Gr.1a 이다. 상수 결정법을 선정하기 위해 실제 응력-변형률 데이터를 모두 이용하는 증분 소성 이론과 Ramberg-Osgood 상수를 이용하는 변형 소성이론을 유한요소 해석에 적용하여 계산한 J 적분과 균열 열림 변위를 비교하였다. 비교 결과에서 증분 소성 이론 결과와 가장 잘 일치하는 상수 결정법을 최종적으로 파단전 누설 평가에 적합한 방법으로 선정하였다.

방폭형 적외선 가연성가스 누출검지기 개발 및 정확도 향상 연구 (A Study on the Development and Accuracy Improvement of an IR Combustible Gas Leak Detector with Explosion Proof)

  • 박규태;유근준;조영도;권정락;안상국;김희식
    • 한국가스학회지
    • /
    • 제18권3호
    • /
    • pp.1-12
    • /
    • 2014
  • 본 논문에서는 적외선센서를 이용하여 방폭형 휴대용 가연성가스 누출검지기를 개발하고 아울러 가스의 농도를 측정하는 정확도를 향상시키는 알고리즘을 제안하였다. 국내최초로 내압 및 본질안전방폭규격(Ex d ib) 적용하여 적외선 가스누출검지기는 개발하였으며, 선형회귀 방정식과 2차 라그랑지(Lagrange) 보간 다항식(interpolation polynomial)을 사용하여 측정정확도를 개선하였다. 아울러 본 연구에서는 현장검사원들의 요구사항을 조사하여 현장에 부합하도록 성능을 향상시키고, 편의기능을 추가하였다. 본 연구에서 개발한 가스누출검지기와 타사의 검지기를 비교하기 위하여 한국가스안전공사에서 제조한 표준가스 8종을 가지고 측정시험을 실시하였다. 본 연구에서 개발한 가스누출검지기의 검지 정확도가 우수함을 실험결과를 통하여 증명하였다.

카메라를 이용한 고압 증기 배관 누설/진동 감시시스템 개발 (Development of Leak and Vibration Monitoring System for High Pressure Steam Pipe by Using a Camera)

  • 전형섭;서장수;채경선;손기성;김세오;이남희
    • 비파괴검사학회지
    • /
    • 제36권6호
    • /
    • pp.496-503
    • /
    • 2016
  • 발전소나 석유화학 플랜트 구조물에 누설이 발생하면 인명 피해 및 경제적인 손실을 초래한다. 이러한 누설은 플랜트 배관의 진동으로 인한 피로파괴나 배관 감육으로 인해 발생한다. 플랜트 배관의 진동을 감시하기 위한 방법으로 주로 가속도센서나 레이저센서가 사용되지만 설치 및 운용의 어려움이 따르고 동시에 광범위 측정 시 비용 증가가 발생하게 된다. 이러한 문제점들을 해결하기 위해 최근 카메라를 이용한 누설 및 진동 변위 측정 방법에 대한 연구가 이루어지고 있다. 카메라를 이용한 누설 및 진동 변위 측정 방법은 설치가 간단하고 원거리 측정 및 넓은 범의의 측정이 가능한 장점을 가지고 있다. 따라서 본 연구에서는 카메라를 이용해 누설 및 진동 변위를 측정할 수 있는 시스템을 개발하였고 실험을 통해 성능을 검증하였다.

$SF_6$가스절연 변압기 ($SF_6$ Gas Insulated Transformer)

  • 조광제;홍기돈;하영식;조규복;노철웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.304-309
    • /
    • 1991
  • We introduce the trend, of several countries, to the gas insulated transformer recently coming into the spot light by the advantages of less weight, GIS-lization, low noise level and easiness to decrease environmental pollutions, and the insulating gases. the cooling media and the insulating materials used for transformer. Hereinafter, additively the design of proto type $SF_6$ gas insulated transformer (insulation, cooling), which was developed by us(HICO) from 1987. 2 through 1990. 3, the manufacturing processes(leak protection, pressure, drying of main body), the accessories, the protective system, the cooling system, the method and the results of test and the evaluation of economics compared with conventional oil-filled transformer are represented.

  • PDF

낮은 오일 농도에서 $CO_2$-Oil 혼합물의 밀도와 점성예측 (Prediction of density and viscosity for $CO_2$-oil mixture at low oil concentration)

  • 윤린
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.136-141
    • /
    • 2008
  • Due to environmental concerns $CO_2$ has been reintroduced as a potential candidate to replace HFCs in refrigeration systems since 1990s. In a refrigeration cycle, oil is utilized in lubricating a compressor. However, although oil separators are installed after a compressor oil is prone to leak to the whole system. The mixing of $CO_2$ and oil, even a small amount of oil, the heat transfer performance in heat exchanger deteriorated and the pressure drop inside tube increases. Therefore, it is needed to precisely estimate the mixture thermodynamic properties of $CO_2$-lubricant oil to correctly design a $CO_2$ refrigeration system. The commonly used method in estimating the mixture properties is the mole based weighting model. However, the accuracy of the method can not be assured. In the present study, $CO_2$-lubricant oil mixture properties including viscosity and density were estimated by using the mixture models, based on the equation of state (EOS).

  • PDF

X-Ray Security Checkpoint System Using Storage Media Detection Method Based on Deep Learning for Information Security

  • Lee, Han-Sung;Kim Kang-San;Kim, Won-Chan;Woo, Tea-Kun;Jung, Se-Hoon
    • 한국멀티미디어학회논문지
    • /
    • 제25권10호
    • /
    • pp.1433-1447
    • /
    • 2022
  • Recently, as the demand for physical security technology to prevent leakage of technical and business information of companies and public institutions increases, the high tech companies are operating X-ray security checkpoints at building entrances to protect their intellectual property and technology. X-ray security checkpoints are operated to detect cameras and storage media that may store or leak important technologies in the bags of people entering and leaving the building. In this study, we propose an X-ray security checkpoint system that automatically detects a storage medium in an X-ray image using a deep learning based object detection method. The proposed system consists of an edge computing unit and a cloud-computing unit. We employ the RetinaNet for automatic storage media detection in the X-ray security checkpoint images. The proposed approach achieved mAP of 95.92% on private dataset.

청정에너지농업시스템 개발에 따른 실증단지의 온실가스배출량 분석 (Analysis of Greenhouse Gas Emission associated with Clean Energy Agriculture System Development)

  • 김태훈;윤성이
    • 한국유기농업학회지
    • /
    • 제23권4호
    • /
    • pp.643-658
    • /
    • 2015
  • This study presents detailed emission of greenhouse gases of using Clean Energy Agriculture System according to a cradle-to-gate life-cycle assessment, including emission from energy use and leak of Biogas. Calculations were done with the PASS software and the covered gases are $CH_4$, $N_2O$ and $CO_2$, Total GHG fluxes of amount to $1719.03kgCO_2/day$, $39.63kgCO_2/day$ (2.31%) are from facility house process, $0.19kgCO_2/day$ (0.01%) are from transport process, $696.72kgCO_2/day$ (40.53%) are from Anaerobic digestion process, $846.61kgCO_2/day$ (49.25%) are from Heating and cooling system, $135.88kgCO_2/day$ (7.90%) are from Fertigation production process. The results suggest that for effective reduction of GHG emissions from Facility house using clean energy. Reduction targets should address both the production process as defined by IPCC sectors and the consumption process. An LCA assessment as presented here could be a basis for such efforts.