• Title/Summary/Keyword: CNG 충전시스템

Search Result 12, Processing Time 0.022 seconds

A Development of Simulation Program for CNG Refueling Station (CNG 충전시스템 충전특성해석 프로그램 개발)

  • Yang, Pan-Seok;Kang, Chan-Goo;Kwan, Yong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.331-336
    • /
    • 2001
  • Theoretical approach was taken to the whole CNG refueling process. In particular, this study was focused on the prediction of flow rate at any given piping configuration of CNG system, in order that a simulation program for the CNG refueling system should be developed. The simulation result of refueling process was compared with experimental result obtained from various kinds of fueling configuration. The simulation results showed a satisfactory agreement within 10% errors in fueling time, fueling amount, and residual pressure. The developed program would be used a good engineering tools for estimating fueling performance for a any given CNG station.

  • PDF

CNG 충전소의 누출$\cdot$확산에 대한 위험성 평가

  • 이동춘;유상빈;이수경
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.05a
    • /
    • pp.137-140
    • /
    • 1998
  • 세계적으로 산업 각 분야에서 석유 소비가 증가하면서, 석유 의존도가 날로 심화되고 있다. 특히 우리나라는 원유 전량을 수입에 의존하고 있는 실정으로 수송분야의 경우 석유 의존도가 절대적으로 높아 이를 줄이기 위해서는 대체 연료차량 개발이 필요하다 하겠다. 또한 자동차 배출가스로 인한 대기 오염이 심화되면서 청정 연료 차량 개발 필요성 또한 시급히 해결해야 할 과제로 대두되고 있다. 이를 위해 CNG 차량에 대한 검토가 적극적으로 이루어지고 있으며 차량에 공급할 연료를 위한 충전소 시스템에 대한 개발연구가 한창 진행 중에 있다. (중략)

  • PDF

A Study on the Quantitative Measurement of Oil Carry-over in Natural Gas Vehicle fueling Station Using A Gravimetric Method (무게측정법을 이용한 천연가스 자동차 충전소 오일전이 정량 분석에 대한 연구)

  • Hwang, Sung-Soo;Oh, Jun-Seok;Kim, Ki-Dong;Oh, Young-Sam;Choi, Kyung-Sik;Kim, Hack-Eun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.12-17
    • /
    • 2015
  • The core of the CNG fueling station is the compressor and most of CNG compressors in Korea require lubrication. Lubrication oil of CNG compressor that can be transferred into the pressure regulators and the engines of fueling system can cause a negative effect on NGV(Nature Gas Vehicle) performance during refueling due to oil Carry-over. In order to avoid the problem, it is necessary to enhance the quality of the compressed natural gas by measuring quantitatively the amount of the transferred oil. In this research, a sampling device and sampling tube were developed, which can be used with a gravimetric method of detection to measure CNG oil Carry-over. In addition, CNG samples were taken at 6 pre-selected CNG fueling stations and analysed for their trace oil Carry-over. The measured total oil Carry-over ranged from 2.569 to 6.509 ppm. This test measurements were compared with those of previous studies to verify the results.

Development of Sensor Module and Control System Software for LPG/CNG Stations (LPG/CNG용 센서 모듈 및 관제시스템 S/W 개발)

  • Cho, Beomsek;Kim, Sungkwang;Kim, Sungtae;Kim, Jongmin
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.53-59
    • /
    • 2018
  • In Korea, The number of installed LPG Charging stations is about 2000, increasing by 26 every year. In these, about 500 charging stations are older above 15 year, accounting about 25% of total stations. About 86% of them are located in the city, which is causing serious damage if accident occurs. In this paper, we developed a duel gas sensor module and integrated control system software that can prevent and correspondence to gas leaks and fire accidents at LPG/CNG charging stations. The dual type sensor module has the function of collecting and transmitting the measured data to the sensors of methane, butane and hydrogen through RF433Mhz communication. In addition, each sensor is attached with two to improve stability and accuracy. The integrated control system software detects real-time data of the devices measured by the sensors and it send to the PC and smart phone of manager. Therefore, if accident occurs, the manager can check the status of the charging station regardless of time and place.

A Study on Fault Detection Monitoring and Diagnosis System of CNG Stations based on Principal Component Analysis(PCA) (주성분분석(PCA) 기법에 기반한 CNG 충전소의 이상감지 모니터링 및 진단 시스템 연구)

  • Lee, Kijun;Lee, Bong Woo;Choi, Dong-Hwang;Kim, Tae-Ok;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.53-59
    • /
    • 2014
  • In this study, we suggest a system to build the monitoring model for compressed natural gas (CNG) stations, operated in only non-stationary modes, and perform the real-time monitoring and the abnormality diagnosis using principal component analysis (PCA) that is suitable for processing large amounts of multi-dimensional data among multivariate statistical analysis methods. We build the model by the calculation of the new characteristic variables, called as the major components, finding the factors representing the trend of process operation, or a combination of variables among 7 pressure sensor data and 5 temperature sensor data collected from a CNG station at every second. The real-time monitoring is performed reflecting the data of process operation measured in real-time against the built model. As a result of conducting the test of monitoring in order to improve the accuracy of the system and verification, all data in the normal operation were distinguished as normal. The cause of abnormality could be refined, when abnormality was detected successfully, by tracking the variables out of the score plot.

Suggestion for Safety Improvement of Compressed Natural Gas Vehicle (압축천연가스 자동차의 안전성 향상을 위한 제언)

  • Kim, Young-Seob;Park, Kyo-Shik;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.1-7
    • /
    • 2012
  • Systematic safety research by Korea Government has been made to enhance the safety of CNG (compressed natural gas) vehicles since the burst of compressed cylinder of an urban bus in August 9, 2010. This article summarizes some major activities to ensure the safety of CNG vehicles, which covers review of regulation, safety management system including standard of inspection and certification, and training program of inspectors and car mechanics. Specifically, the followings were reviewed; type of CNG cylinder, location of CNG cylinder, material and type of fuel line and vent line, modification of pipeline connection, installation of gas detector, installation of emergency shutdown valve, installation of protecting cover for cylinder, obligations for CNG vehicle filling station. improving periodical inspection, routine test on gas vehicles, training program for engaged in gas vehicles, and designation of safety manager for CNG bus company. This paper suggests how to improve safety of CNG vehicles as a result of review of above mentioned check items.

Design of Spark Advanced Controller for Improvement in Power and Torque of CNG Bi-Fuel Vehicle (압축천연가스 겸용 차량의 출력 및 토크 향상을 위한 점화 진각 제어기 설계)

  • Park, Jin-Hyun;Kim, Sung-Hoon;Cho, Seung-Wan;Choi, Young-Kiu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.7
    • /
    • pp.1641-1646
    • /
    • 2010
  • Recently, environmental concerns increased, CNG fuel research for the prevention against air pollution is actively. But, the problems of CNG fuel have less output and a shorter charging distance than gasoline. Especially, the causes of the torque and output reduction are the mixed fuel has a combustion timing loss in case of CNG fuel which has a smaller heating value per a unit volume and a slower flame propagation speed than gasoline. In this paper, we design the spark advanced controller in consideration of the spark timing loss. Through the experimental of chassis dynamometer, we show that maximum power and torque have improved compared to that of general CNG bi-fuel system.

A Study on the Internal Flow Analysis of High-pressure Shut-off Valve for CNG Charging Station Piping System (CNG 충전소 배관시스템용 고압 차단밸브에 대한 내부 유동해석에 관한 연구)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.773-779
    • /
    • 2021
  • CNG, which has recently been attracting attention as an alternative fuel in the transportation field to reduce emissions caused by global warming, is natural gas with abundant reserves and mainly composed of methane. Being in a gaseous state, natural gas requires the compression and liquefaction processes for transportation. Until now, general shut-off valves for liquid and gas piping have been developed in Korea, but there are few studies on shut-off valves for high pressures of about 200 bar. Currently, research on the flow analysis of valves is being actively conducted around the world. However, there are relatively many studies on large valves such as low-pressure valves or shipbuilding and marine, and the safety factor through structural analysis to check the structural integrity of the valve is checked at the design stage. Since it is necessary to have a fast response speed while minimizing pressure and speed loss due to flow change, basic research was conducted on the flow analysis of the valve to secure design data, and the numerical analysis was performed on high-pressure automatic shut-off valves applied to CNG refueling stations. After securing the basic valve shape through reverse engineering for advanced products, we compared the valve flow coefficient Cv coefficient with advanced products. As a result, it was found that the reverse engineering model was at the level of about 60%. However, we compared the Cv coefficient by modifying the reverse engineering model, and the result showed that it was improved to about 96%.

Development of Total LNG/LPG Management System for Domestic Use (국내 LNG/LPG 종합관리시스템 개발)

  • Cha, Sung-Ik;Baek, Gi-Inn;Park, Dal-Young;Jo, Young-Ah;Min, Nam-Kim
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2687-2689
    • /
    • 2003
  • 국내 LNG/LPG 누출을 관리할 수 있는 유무선 복합 종합관리시스템을 개발하였다. 이 시스템은 무선가스누출 탐지 및 제어부, 유선가스누출 탐지 및 제어부, 종합관리 시스템부로 구성되며, 특징으로는 무선가스누설 제어부 : 통신속도 1200bps, 유선가스누설 제어부 : 내부통신속도 9600 bps, IEEE 802 양방향 통신 방식, 최대전송속도 25 Mbps, 군 관리기능(server to server). 자체진단기능 등이다. 본 시스템을 가스공사 연구개발원 내에 운영되고 있는 CNG 및 LCNG 충전에 설치 운영하여 성능시험을 거친 결과, 현재까지 기존의 외국제품과 동등한 성능을 보이고 있으며 단가면에서도 2/3정도로 경쟁력을 가지고 있다. 보다 장기적인 현장적용 시험을 통해 성능 및 장기안정성 등이 확립되면 국내시장뿐만 아니라 수출을 통한 국제시장 점유도 기대할 수 있을 것이다.

  • PDF

A Study on Safety and Operational Management System for CNG Filling Stations (CNG충전소 안전.운영 관리를 위한 시스템 구축에 관한 연구)

  • Yang, Jae-Mo;Kim, Bum-Su;Yong, Jong-Won;Ko, Byung-Seok;Lee, Dong-Hyuk;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.6
    • /
    • pp.8-13
    • /
    • 2011
  • All over the nation, a lot of industrial complex utilize gas as their energy source. Possibilities are fire, explosion, and leakage could happen any time in these large complexes. To prevent these tragic accidents and to minimize the damage when the accident occurs, the development of diagnostic technology for these facilities is imperative. The safety check is conducted on an individual and partial basis, currently. Accordingly, the accumulation and improvement of the safety management technology is necessary in order to make all the different checking techniques and management systems compatible, since checking processes, result interpretation techniques, and subsequent prognoses are not the same. The program provides damage scenarios from gas leakage. The output enables policy makers to predict the degree of infliction. Through this program, engineers are able to design an effective gas safety program to operate and maintain ubiquitous gas facilities.